• Title/Summary/Keyword: safety experiment

Search Result 2,230, Processing Time 0.028 seconds

Development of Rapid Analytical Method for Heavy Metals (Cd, Pb) in Meju using fs LA-ICP-MS (fs LA-ICP-MS를 이용한 메주의 유해중금속(Cd, Pb) 신속 분석법 개발)

  • Shin, Hee-Chang;Choi, Ji-Hye;Kim, Yong-Kyoung;Kim, Dae-Jung;An, Jae-Min;Kim, Sung-Youn
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.129-135
    • /
    • 2022
  • The official analytical method for the analysis of harmful heavy metals in Meju, distributed in Korea, employs a strong acid to decompose the organic components. This analysis is time consuming and harmful to the users and/or the environment. This study aimed to develop a new pre-treatment technology using laser ablation, to rapidly analyze harmful heavy metals without using strong acids. The results obtained from this method were validated by the National Institute of Food and Drug Safety Evaluation guideline (NIFDS, 2016). Moreover, a comparison of the two methods showed that the analytical time for 55 Meju samples was shortened by 96% or more in the new method. The results showed no significant difference in the recovery ranging from 90-120%. The proposed method proved suitable for detecting harmful heavy metals in Meju.

Comparison of Experimental and FDS Data for Calculating Heat-Affected Range in Forest Fires (산불 열영향 범위 산정을 위한 실험 및 FDS 데이터 비교)

  • Kim, H.S.;Kang, Y.J.;Kim, J.H.;Kim, K.H.;Lee, B.D.;Kim, Jeong Hun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.91-96
    • /
    • 2014
  • This research deals with the combustion experiment of pine trees, which are the most representative species in Korea. Experimental data are compared with theoretical ones using Fire Simulation Program(FDS). It is considered that horizontal/vertical temperature distribution and radiant heat influence on adjacent areas in fire scenes. The linear function for separation distance to temperature was drawn by applying Stefan-Boltzmann's law; $y=112.13133{\times}({\sigma}T^4)^{-0.52916}$ for calculating the separation distance. In combustion experiment, the radiant heat came to $1.4{\sim}1.5kW/m^2$ in case of the separation distance by one meter. The numerical values mean that human body show the critical level of pain after one minute without a protective equipment.

A Experimental Study on the Fire Safety of Drum-type Electric Washing Machine (드럼세탁기 화재안전성 확보를 위한 실험연구)

  • Hong, Sung-Ho;Lee, Sang-Hyun;Park, Sang-Tae;Yu, Hyun-Jong;Jeon, Woong-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.131-133
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

  • PDF

A Experimental Study on the Fire Hazards in Drum-Type Electric Washing Machine (건조일체형 드럼세탁기의 화재위험성에 관한 실험연구)

  • Hong, Sung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.328-331
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

Human Experimental Studies on the Risk of Electric Shock due to Damage of Underground Wire in Street Lamp (가로등의 지중전로 손상으로 인한 인체감전 위험성에 대한 실험 연구)

  • Chung, Jae-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.5
    • /
    • pp.6-12
    • /
    • 2009
  • This study performed an experiment for the danger of an electric shock in the human body, which is directly touched or approached to the exposure of buried metals in a leak caused by certain ground faults at a buried cable in street lamp. In the results of the experiment, the dangerous of electric shocks due to the earth specific resistance and wet and submersion of the earth surface represents a high level as the human body is directly touched to the buried metal at a leak point. In addition, it can be seen that the safety of the human body is influenced by the earth specific resistance, separated distance from buried metals, and shape of buried metals at around the leak point.

Pressure Wave Propagation in the Discharge Piping with Water Pool

  • Bang Young S.;Seul Kwang W.;Kim In-Goo
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.285-294
    • /
    • 2004
  • Pressure wave propagation in the discharge piping with a sparger submerged in a water pool, following the opening of a safety relief valve, is analyzed. To predict the pressure transient behavior, a RELAP5/MOD3 code is used. The applicability of the RELAP5 code and the adequacy of the present modeling scheme are confirmed by simulating the applicable experiment on a water hammer with voiding. As a base case, the modeling scheme was used to calculate the wave propagation inside a vertical pipe with sparger holes and submerged within a water pool. In addition, the effects on wave propagation of geometric factors, such as the loss coefficient, the pipe configuration, and the subdivision of sparger pipe, are investigated. The effects of inflow conditions, such as water slug inflow and the slow opening of a safety relief valve are also examined.

A study of on the occupant movement speed during emergency evacuations for the evacuation safety assessment of domestic buildings (국내 건축물의 피난안정성평가를 위한 비상대피 시 재실자 이동속도에 관한 연구)

  • Youn, Ho-Ju;Hwang, Eunkyung
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.332-338
    • /
    • 2013
  • Recently in Korea, in order to ensure evacuation safety within buildings, reviewing and evacuation assessment using computer simulations has been performed from the planning and design stages. Since the results from the assessment mainly depends on the initial values of input elements, it is important to establish element specific data. Nevertheless evacuation related experiments and research are still insufficient to apply overseas standards to domestic conditions. This study intended to conduct a experiment on evacuation movement speed by age as part of element-specific data construction for domestic occupant movement speed. After analyzing domestic and overseas studies on evacuation movement speed, we conducted the experiment of evacuation movement speed for 134 people. Then, by carrying out a comparative analysis of the results of the movement speed obtained from the experiment with overseas movement speeds, we followed the validation procedures of the experimental results under domestic evacuation conditions. The data derived from the experiment is expected to serve as a basis for the movement speed of domestic evacuation safety assessment.

Application of data driven modeling and sensitivity analysis of constitutive equations for improving nuclear power plant safety analysis code

  • ChoHwan Oh;Doh Hyeon Kim;Jeong Ik Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.131-143
    • /
    • 2023
  • Constitutive equations in a nuclear reactor safety analysis code are mostly empirical correlations developed from experiments, which always accompany uncertainties. The accuracy of the code can be improved by modifying the constitutive equations fitting wider range of data with less uncertainty. Thus, the sensitivity of the code with respect to the constitutive equations is evaluated quantitatively in the paper to understand the room for improvement of the code. A new methodology is proposed which first starts by dividing the thermal hydraulic conditions into multiple sub-regimes using self-organizing map (SOM) clustering method. The sensitivity analysis is then conducted by multiplying an arbitrary set of coefficients to the constitutive equations for each sub-divided thermal-hydraulic regime with SOM to observe how the code accuracy varies. The randomly chosen multiplier coefficient represents the uncertainty of the constitutive equations. Furthermore, the set with the smallest error with the selected experimental data can be obtained and can provide insight which direction should the constitutive equations be modified to improve the code accuracy. The newly proposed method is applied to a steady-state experiment and a transient experiment to illustrate how the method can provide insight to the code developer.