• Title/Summary/Keyword: safety equipment

Search Result 2,956, Processing Time 0.027 seconds

Evaluation of Oven Utilization Effects at School Foodservice Facilities in Daegu and Gyeongbuk Province (대구·경북지역 학교급식소 오븐 사용 효과 평가)

  • Lee, Jung-A;Lee, Jin-Hyang;Bae, Hyun-Joo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.7
    • /
    • pp.1064-1072
    • /
    • 2010
  • The objectives of this study were to gain an overview of practices and effect evaluation of oven utilization at school foodservice facilities in Daegu and Gyeongbuk province. Out of 147 dieticians, who responded for questionnaires, 44 dieticians used the oven and 103 dieticians did not use the oven. All statistical analyses were conducted with the SPSS 14.0 statistical software program. With regard to the style of foodservice system, 74.4% were urban, 23.3% were rural, and 2.3% were remote country. Also, 23.3% of school foodservices produced meals by batch cooking. According to the results of the expected effect and using effect analysis for 27 items, the average of evaluation score about expected effect was 1.64 points and that of using effect was 1.61 points. Both expected effect and using effect had higher scores than average points in 13 items out of 27 items. Using effect had higher scores than expected effect in 4 items. In conclusion, using ovens could help to increase foodservice satisfaction of students at school foodservice, because it can improve the various cooking methods and the food safety management. Therefore, it is important to modernize and automate cooking equipment for quality improvement of school foodservice operations.

Study on the structure of the articulation jack and skin plate of the sharp curve section shield TBM in numerical analysis (수치해석을 통한 급곡선 구간 Shield TBM의 중절잭 및 스킨플레이트 구조에 관한 연구)

  • Kang, Sin-Hyun;Kim, Dong-Ho;Kim, Hun-Tae;Song, Seung-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.421-435
    • /
    • 2017
  • Recently, due to the saturation of ground structures and the overpopulation of pipeline facilities requires to development of underground structures as an alternative to ground structures. Thus, mechanized tunnel construction of the shield TBM method has been increasing in order to prevent vibration and noise problems in construction of the NATM tunnel for the urban infrastructure construction. Tunnel construction plan for the tunnel line should be formed in a sharp curve to avoid building foundation and underground structures and it is inevitable to develop a shield TBM technology that suits the sharp curve tunnel construction. Therefore, this study is about the structural stability technology of the articulation jack, shield jack and skin plate for the shield TBM thrust in case of the mechanized tunnel construction that is a straight and sharp curve line. The construction case study and shield TBM operation principle are examined and analyzed by the theoretical approach. The torque of the cutter head, the thrust of the articulation jack and the shield jack, the amount of over cutting for curve is important respectively in shield TBM construction of straight and sharp curve line. In addition, it is very important to secure the stability of the skin plate structure to ensure the safety of the inside worker. This study examines the general structure and construction of the equipment, experimental simulation was carried out through numerical analysis to examine the main factors and structural stability of the skin plate structure. The structural stability of the skin plate was evaluated and optimizes the shape by comparing the loads of the articulation jack by selecting the virtual soil to be applied in a straight and sharp curve line construction. Since the present structure and operation method of the shield TBM type in domestic constructions are very similar, this study will help to develop the localized shield TBM technology for the new equipment and the vulnerability and stability review.

A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer (재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究))

  • Jung, Ha-Chung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF

Review of 2014 Major Medical Decisions (2014년 주요 의료판결 분석)

  • Jeong, Hye Seung;Lee, Dong Pil;Yoo, Hyun Jung;Lee, Jung Sun
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.1
    • /
    • pp.155-190
    • /
    • 2015
  • The court sentenced meaningful decisions related to the medical service in 2014. The court assumed the negligence of medical staff in the accident if being broken while using the medical equipment for not an original purpose at the time of surgery and ruled that the compensation for damage can be recognized in recognition of the causal relationship between the explanation duty violation and side effect's happening when unproven surgery on safety is implemented regarding the duty of explanation, that in the case of cosmetic surgery, the subject on the duty of explanation needs to be expanded compared to the general medical practice and that the duty of explanation cannot be accepted for the range that cannot be expectable. Also, the court has provided the requirement and limitation of self-determination exercise in case of the crash between patient's self-determination and doctor's duty of care and has ruled that as automobile insurance contract is a contract with the insurance company to pay regarding liability for car accidents, treating patients and taking the insurance money is not illegal activity even for the unlicensed hospital violating the medical law while established. The judgment stating the opinion that medical practitioners cannot be punished according to the medical law prohibiting the receiving of rebate in case that medical practitioners did not receive benefit while the medical institution itself gained an unfair economic benefit also stands out. And the court has ruled that even if the medical institution who received a business suspension is closed, the suspension is still effective in case that the same operator opens a new medical institution in the same place, ruled on the requirement to conduct a medical service outside of the medical institution that the doctor opened and ruled that the administrative penalty cannot be conducted prior to the conviction on charge of violating the medical law.

  • PDF

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

A Study on MBES Error Data Removing using Motion Sensor (Motion Sensor를 이용한 MBES 오측자료 제거 연구)

  • Kang, Moon-Kwon;Choi, Yun-Soo;Chang, Min-Chol;Yoon, Ha-Su
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Sounding data is the essential source for the safety of ships navigation system, and fundamental to the reasonable usage and maintenance of the ocean as well. As IT tech, positioning equipment such as GPS and INS, echo sounder are developed, recently, the precise submarine topography database bas been built by Multi-Beam Echo Sounder. However, MBES data includes some inevitable error caused by several factor, and some data have errors where the terrain is wobble. The error, which causes the $moir\acute{e}$ pattern error is the main factor hindering the accuracy of MBES data results, and therefore it is necessary to figure out the main cause of the error for the improvement of the accuracy by removing error data. On this research, the main cause of the error data is studied by analyzing motion sensor value of data including the $moir\acute{e}$ pattern error. Thus, as the result of examination, it turns out that the $moir\acute{e}$ pattern error is related to the standard deviation of Roll, and error data values are results of the non-correspondence between Swath data and Roll values caused by the drastic change of Roll values. Accordingly, the error data is removed by comparing between the gradient of Swath data and Roll values. Finally, as the result of removing error data, it is expected to be able to estimate the quality of MBES using the standard deviation of Motion sensor's Roll value, and calculate the additive error factor, which minimize non-corresponding data, and also this research must be contributed to improve the accuracy of sounding for small vessels with lots of motion in the bad circumstance for navigation.

A Proposition on Reasonable Termination Procedure in Remaining-oil Recovery Work from a Sunken Tanker in Korean Territory (국내 침몰유조선 잔존유 회수작업의 합리적 종료절차 제안)

  • Kang, Kwang-Gu;Shim, Yoo-Taek;Kang, Sin-Young
    • Journal of Navigation and Port Research
    • /
    • v.38 no.4
    • /
    • pp.379-384
    • /
    • 2014
  • In case of sunken tankers, remaining-oil recovery operation should be conducted due to possible oil spill accident. However, the deep sea operation make difficulties in checking the completion of remaining oil recovery process, therefore the work termination procedure is very important. In this paper, a reasonable work termination procedure through the comparison and analysis of two cases(Youil No.1 and Osung No.3, Kyung-Shin) which were performed in different method, using disparate equipment. By investigating previously applied methods and techniques, work speed, safety and expenses were compared. The proposed ending procedure of the remaining-oil recovery project is to recover the remaining oil from each cargo tanks and to clean up such tanks whilst an independent surveyor proceeds to a confirmation procedure whereby said surveyor checks out whether any remaining oil exists by putting a stick in each cleaned up tanks and opening up the hatch cover of the tanks or the top place of the tanks to confirm the cleanness of oil. Such procedure shall be done through discussion by the ordering party, contractor and the independent surveyor all together with a flexible application.

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

A Study on the Specialized Classrooms of Governmental Secondary Schools in the Japanese Colonial Era -Focused on Architectural Drawings for Collected by National Archives of Korea (일제 강점기 관립 중등학교 특별교실에 관한 연구 -국가기록원 소장 학교건축 도면을 중심으로)

  • Lee, Jeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2476-2483
    • /
    • 2014
  • This study aims to review the characteristics of specialized classrooms for governmental secondary schools in the Japanese Colonial Era by analyzing architectural drawings collected by National Archives of Korea. The results of this study are summarized as follows 1) Under the influence of Japanese science promotion of that time, specialized classrooms for science were considered as one of essential facilities. Typically exclusive specialized classrooms were assigned to two major science subjects : physics-chemistry and biology. 2) To science specialized classrooms, ancillary rooms for preparation, experiment equipment and specimen were attached and science lecture room with stepped floor was planned additionally only for the lecture on theories and the demonstration of experiment. 3) Specialized classrooms for science were zoned independently of other facilities because of the special equipments and safety. 4) Art rooms were common to both boys' and girls' schools but concerning music rooms, girls' schools had special concerns, whereas boys' schools did not. 5) Specialized classrooms for homemaking subject of girls' school were as much important as those for science subjects of boys' school. 6) Some early-established Korean boys' schools had handicraft rooms which were the symbol of vocational education-oriented, unequal policy on Koreans. Though not general cases, specialized classrooms for geography-history were planned for Japanese boys' school. Restricted to governmental secondary schools but considering the uncommon state of specialized classrooms of that time, these characteristics show conditions of early time when special classrooms were introduced into Korea.