• 제목/요약/키워드: safety design

검색결과 9,633건 처리시간 0.039초

손상 선박의 안전성 향상 설계 기술 개발 (Development of Design Technology for Safety Enhancement of Damaged Ship)

  • 이순섭;이동곤;김기섭
    • 대한조선학회논문집
    • /
    • 제46권1호
    • /
    • pp.69-77
    • /
    • 2009
  • Loss of human lives and properties including environmental damage due to large scale accidents requires change of our perception to marine safety. IMO is trying to re-establish overall marine safety system through long term plan such as GBS. Along this line, current regulation based safety evaluation is in process of changing into performance based methods, and for this transition, simulation based safety evaluation during design stage considering damage is highly necessary. In this paper, first, damage scenario is developed from IMO regulations and accident case studies. Then an integrated and simulation based safety evaluation prototype system considering both damage stability and structural safety is developed for the use during ship design process.

제품기획단계의 안전성 평가 필요성에 관한 연구 (A need of safety evaluation for product planning step)

  • 박지영;조암
    • 대한안전경영과학회지
    • /
    • 제10권1호
    • /
    • pp.23-31
    • /
    • 2008
  • Recently, there is a rise of accident by some defective products, especially it reported that a serious fact is a defect of design causing some problem since execute a product liability(PL), people who use products have been able to bo remunerated for a damage to those defects, so responsibilities of companies are rising more and more. Therefore, companies that are obligated to manufacture a safety product, and should make preparation for PL. For solving the problem, even though manufacturers tried to make a safety product ay mixed ways, it is seldom that its safety is considered from planning a design. This thesis has suggested a way aimed at improving a safety of products through considering a stage of a plan, by searching and analyzing the design-process in to each steps.

안전무결성을 달성하기 위한 FMEDA 분석 기반 PESSRAE 설계 (Design of PESSRAE To Achieve Safety Integrity With FMEDA Analysis)

  • 허제호;김기봉;정기현;안석찬
    • 대한임베디드공학회논문지
    • /
    • 제17권3호
    • /
    • pp.157-165
    • /
    • 2022
  • As the number of the installed escalators in Korea continues to increase, the accident rate is also increasing. Therefore, it would be necessary to proactively secure safety. PESSRAE is a controller that implements safety functions as electric/electronic/programmable electronic devices to respond to risks that may occur in escalators. Safety Integrity Level (SIL) is assigned to the safety functions of PESSRAE and it must be verified that the quantitative target value according to the SIL level is satisfied. In this paper, the initial PESSRAE is analyzed using the FMEDA (Failure Mode, Effects and Diagnostic Analysis), which is a quantitative safety analysis method, and design improvement specifications are derived from the analysis in order to satisfy the quantitative target values. Based on the derived design specifications, the improved PESSRAE controller was manufactured. And the appropriateness of the design was verified experimentally in a testbed environment simulating the real environment.

Design Improvement for the Cooling System of the Interim Spent Fuel Storage Facility Using a PSA Method

  • Ko, Won-Il;Park, Jong-Won;Park, Seong-Won;Lee, Jae-Sol;Park, Hyun-Soo
    • Nuclear Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.440-451
    • /
    • 1996
  • With emphasis on safety, this study addresses for better design condition for the cooling system in a wet-type interim spent fuel storage facility, using a probabilistic safety assessment method. To incorporate the design renovation into the design phase, a simple approach is proposed. By taking the cooling system of a reference design, a fault tree analysis was performed to identify the weak point of the considered system, and then basic factors for design renovation were defined. A total of 21 design alternatives were selected through the combination of the basic factors. Finally, the optimum design alternative for the cooling system is derived by means of the cost and effect analysis based on the estimated cost, system reliability and assumed probabilistic safety criteria. With the assumption that the failure frequency of at-reactor spent fuel cooling system compiles with probabilistic safety criteria for the interim spent fuel cooling system, it was shown that the optimum alternative should have l00% cooling loop redundancy with one pump per cooling loop and a cleanup system installed separately from the main loop. Furthermore, it also should be classified into safety system. The result of this study can be used as a useful basis to identify factors of safety concern and to establish design requirements in the future. The method also can be applied for other nuclear facilities.

  • PDF

Level 1 probabilistic safety assessment of supercritical-CO2-cooled micro modular reactor in conceptual design phase

  • So, Eunseo;Kim, Man Cheol
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.498-508
    • /
    • 2021
  • Micro reactors are increasingly being considered for utilization as distributed power sources. Hence, the probabilistic safety assessment (PSA) of a direct supercritical-CO2-cooled fast reactor, called micro modular reactor (MMR), was performed in this study; this reactor was developed using innovative design concepts. It adopted a modular design and passive safety systems to minimize site constraints. As the MMR is in its conceptual design phase, design weaknesses and valuable safety insights could be identified during PSA. Level 1 internal event PSA was carried out involving literature survey, system characterization, identification of initiating events, transient analyses, development of event trees and fault trees, and quantification. The initiating events and scenarios significantly contributing to core damage frequency (CDF) were determined to identify design weaknesses in MMR. The most significant initiating event category contributing to CDF was the transients with the power conversion system initially available category, owing to its relatively high occurrence frequency. Further, an importance analysis revealed that the safety of MMR can be significantly improved by improving the reliability of reactor trip and passive decay heat removal system operation. The findings presented in this paper are expected to contribute toward future applications of PSA for assessing unconventional nuclear reactors in their conceptual design phases.

건설공정 위험성 기반 설계안전성 활용 방안 연구 (A Study on the Application of Safety Design based on the Risk of Construction Process)

  • 이현성
    • 한국재난정보학회 논문집
    • /
    • 제15권4호
    • /
    • pp.493-501
    • /
    • 2019
  • 연구목적: 건설안전 재해를 예방하기 위해 건설기술진흥법에서는 '설계 안전성 검토' 제도를 시행하고 있다. 이에 본 논문에서는 '설계안전성 검토' 제도에서 정한 규정의 실효성을 확보하기 위해 실제 건설현장에서의 시행 절차와 내용을 분석함으로써 해당 제도가 올바르게 정착되어 건설재해 예방에 기여하는데 그 목적이 있다. 연구방법: 건설기술진흥법에서 정한 설계 안전성 제도에서는 자료 검토 단계, 위험요소 도출 및 대안 설정단계, 설계안전성 평가 보고서 작성단계를 거쳐 최종적으로 위험요소에 대한 설계 반영단계 등의 각 단계별 적용사례를 분석하였다. 연구결과: 설계 안전성 제도에 따라 작업공종별로 철근콘크리트 공사, 건설기계공사, 토공공사, 가시설 등 건설사업의 형태별로 다양한 위험요소(Hazard)가 도출되었고, 이 위험요소의 위험등급별 우선순위를 도출하고 이를 해결하기 위해 실제 사례를 작성해 본 결과 다양한 공정에서의 설계 반영사례가 도출되었다. 결론: 본 연구를 통해 A공사에서 적정 기준에 맞는 굴착구배(1:0.3)를 채택했음에도 빈번한 토사 붕괴 사고의 문제를 개선하기 위해 관로터파기 경사에 준해 설계도면에 1:0.5를 채택하여 새로운 설계도면에 반영하였고, 그 결과 현행 굴착 구배 기준을 강화의 강화 필요성을 도출하였다.

Design for Safety :Development and Application of a Formalised Methodology

  • Vassalos, Dracos;Oestvik, Ivan;Konovessis, Dimitris
    • Journal of Ship and Ocean Technology
    • /
    • 제4권4호
    • /
    • pp.1-18
    • /
    • 2000
  • The paper describes a formalisation of a Design for Safety methodology in an integrated envi-ronment, outlines early developments of a software tool, and presents the results of an appli-cation of the methodology to a case study. The approach adopted attempts link safety per-formance prediction through the utilisation of appropriate technical tools, safety assessment deriving from risk-based methodologies and disparate design activities and issues. Black-board systems have been utilised as the platform in the development of the integrated design environment, allowing safety assessment to become an integral part of the design process. Finally, the case study addresses the application of the developed methodology to three dif-ferent arrangements of a conventional passenger Ro-Ro vessel, with the aim to demonstrate the validity of the process and methodology adopted. The findings are presented and dis-cussed, and recommendations given for the way forward.

  • PDF

설계사무소의 D.F.S 인식수준 분석 및 해결방향 (A Study on Perception Level of D.F.S in Architecture Design Firm and Solutions)

  • 유성곤;이근형;신원상;손창백
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.43-44
    • /
    • 2018
  • In the past, safety management has been carried out mainly by constructors, but now, participants of all construction projects such as clients, designers, constructors, and construction managers are being changed to perform safety management together. Among them, the design safety review, which examines whether the client has secured the design safety at the design stage, has been implemented since May 19, 2016, but it has not been properly implemented. Therefore, this study analyzed perception level and problems of D.F.S in architecture design firms and suggested the solutions.

  • PDF

사고 영향 분석을 이용한 성능위주의 내화설계 (Performance Based Design of Passive Fire Protection Using Consequence Analysis)

  • 한동훈;이종호
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.102-107
    • /
    • 2004
  • Performance based design is a recent evolutionary step in the process of designing fire protection systems. In essence, it is a logical design process resulting in a solution that achieves a specified performance. Sometimes the prescriptive solutions presented in various codes and standards are too expensive or inflexible. Often the solutions do not and enables optimization of a solution for cost and function. In this study, performance based design was carried out to determine the extent of passive fire protection for oil terminal facilities. The results of performance based design were compared with those of prescriptive code based design. Performance based design is not always more economic than prescriptive code based design but provides more reliable and effective design that is fit for the purpose.

APR+ 확률론적 안전성평가 및 대형냉각재상실사고 성공기준과 파단크기 민감도 분석 (A Study on the Probabilistic Safety Assessment and Sensitivity Analysis of Success Criteria of Large LOCA for APR+)

  • 문호림;김한곤
    • 한국안전학회지
    • /
    • 제31권6호
    • /
    • pp.129-134
    • /
    • 2016
  • Standard design of APR+(advanced power reactor plus) was certified at 2014 by Korea regulatory body. Based on the experience gained from OPR1000 and APR1400, the APR1400 was being developed as a 1,500MWe class reactor using Korean technologies for design code, reactor coolant pump, and man-machine interface system. APR+ has been basically designed to have the seismic design basis of safe shutdown earthquake (SSE) 0.3g, a 4-train safety concept based on N+2 design philosophy, and a passive auxiliary feedwater system (PAFS). Also, safety issues on the Fukushima-type accidents have been extensively reviewed and applied to enhance APR+ safety. APR+ provides higher reliability and safety against tsunami and earthquake. The purpose of this paper is to implement probabilistic safety assessment considering these design features and to analyze sensitivity of core damage frequency for large loss of coolant accident of APR+.