• Title/Summary/Keyword: safe storage

Search Result 398, Processing Time 0.021 seconds

Estimation of groundwater inflow into an underground oil storage facility in granite

  • Wang, Zhechao;Kwon, Sangki;Qiao, Liping;Bi, Liping;Yu, Liyuan
    • Geomechanics and Engineering
    • /
    • v.12 no.6
    • /
    • pp.1003-1020
    • /
    • 2017
  • Estimation of groundwater inflow into underground opening is of critical importance for the design and construction of underground structures. Groundwater inflow into a pilot underground storage facility in China was estimated using analytical equations, numerical modeling and field measurement. The applicability of analytical and numerical methods was examined by comparing the estimated and measured results. Field geological investigation indicated that in local scale the high groundwater inflows are associated with the appearance of open joints, fractured zone or dykes induced by shear and/or tensile tectonic stresses. It was found that 8 groundwater inflow spots with high inflow rates account for about 82% of the total rate for the 9 caverns. On the prediction of the magnitude of groundwater inflow rate, it was found that could both (Finite Element Method) FEM and (Discrete Element Method) DEM perform better than analytical equations, due to the fact that in analytical equations simplified assumptions were adopted. However, on the prediction of the spatial distribution estimation of groundwater inflow, both analytical and numerical methods failed to predict at the present state. Nevertheless, numerical simulations would prevail over analytical methods to predict the distribution if more details in the simulations were taken into consideration.

Storage Stability of Fresh Jujube Fruits (Zizyphus Jujuba MILLER) (생대추(Zizyphus Jujuba MILLER) 저장성 연구)

  • Song, Jin;Lee, Ka-Soon;Kang, Hyun-Ah;Chang, Kyu-Seob
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.272-277
    • /
    • 1998
  • In order to study storage stability of fresh jujube fruits (Zizyphus jujuba Miller) controlled atmosphere storage, polyethylene film packaging and non-packaging were compared. Jujube fruits were stored on the following gas compositions: 1.5% carbon dioxide and 5, 8, 10, 12% oxygen at $7^{\circ}C$, respectively. And 0.05 mm PE packaging and non-packaging were stored at $1^{\circ}C,\;4^{\circ}C\;and\;7^{\circ}C$. Safe storage period of Bokjo jujube fruits was four weeks when stored in CA condition of $O_2\;10%\;and\;CO_2\;1.5%$ in terms of their overall quality. The rate of weight loss was not much changed either by storage method of CA or by PE film packaging. In surface color the a value of jujube fruits increased but L and b values decreased during the storage period. Hardness showed the trend of increase in all the treatment for 2 weeks of storage while in CA it decreased more than the others after 4 weeks of storage. Soluble solids and titratable acidity were changed slightly. Vitamin C contents were gradually decreased in all treatments, but non-packed jujubes at $1^{\circ}C$ were slightly increased.

  • PDF

Development of an Environmental Monitoring and Warning System for Cold Storage Rouse Using Internet (인터넷을 이용한 저온저장고 환경감시 및 경보 시스템 개발)

  • Jeong, Hoon;Yun, Hong-Sun;Lee, Won-Og;Cho, Kwang-Hwan;Cho, Young-Kil;Park, Won-Kyu;Shin, Jae-Hun
    • Food Science and Preservation
    • /
    • v.10 no.1
    • /
    • pp.28-31
    • /
    • 2003
  • For safe storage of agricultural products in the cold storage house, accurate monitoring of temperature, humidity and gas conditions is necessary. This study was conducted to develop an environmental monitoring and warning system for the cold storage house to improve safety of storage. The system developed in this study is able to monitor temperature, humidity and $CO_2$concentration in the storage house and to send alarm signal to the farmer by telephone and beeper when abnormal conditions have been occurred in the storage house. And the developed system use internet network so we can supervise storage conditions in the home. From the results of the performance test, it was found that the temperature and relative humidity can be controlled within the range of 0.5$^{\circ}C$ and $\pm$2 percent. And farmer's response was fair.

Development of CANDU Spent Fuel Bundle Inspection System and Technology (중수로 사용후연료 건전성 검사장비 개발)

  • Kim, Yong-Chan;Lee, Jong-Hyeon;Song, Tae-Han
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.1
    • /
    • pp.31-39
    • /
    • 2013
  • Nuclear fuel can be damaged under unexpected circumstances in a nuclear reactor. Fuel rod failure can be occurred due to debris fretting or excessive hydriding or PCI (Pellet-to-clad Interaction) etc. It is important to identify the causes of such failed fuel rods for the safe operation of nuclear power plants. If a fuel rod failure occurs during the operation of a nuclear power plant, the coolant water is contaminated by leaked fission products, and in some case the power level of the plant may be lowered or the operation stopped. In addition, all spent fuels must be transferred to a dry storage. But failed fuel can not be transferred to a dry storage. Therefore, the purpose of this study is to develop a system which is capable of inspecting whether the spent fuel in the storage pool is failed or not. The sipping technology is to analyze the leakage of fission products in state of gas and liquid. The failed fuel inspection system with gamma analyzer has successfully demonstrated that the system is enough to find the failed fuel at Wolsong plant.

Development of a Cost-Effective 20K Hydrogen BET Measurement for Nanoporous Materials (나노다공체 물성 측정을 위한 극저온(20K) 수소 BET 개발 및 응용)

  • Park, Jaewoo;Oh, Hyunchul
    • Korean Journal of Materials Research
    • /
    • v.27 no.9
    • /
    • pp.466-470
    • /
    • 2017
  • With the matters of climate change, energy security and resource depletion, a growing pressure exists to search for replacements for fossil fuels. Among various sustainable energy sources, hydrogen is thought of as a clean energy, and thus efficient hydrogen storage is a major issue. In order to realize efficient and safe hydrogen storage, various porous materials are being explored as solid-states materials for hydrogen storage. For those purposes, it is a prerequisite to characterize a material's textural properties to evaluate its hydrogen storage performance. In general, the textural properties of porous materials are analyzed by the Brunauer-Emmett-Teller (BET) measurement using nitrogen gas as a probe molecule. However, nitrogen BET analysis is sometimes not suitable for materials possessing small pores and surfaces with high curvatures like MOFs because the nitrogen molecule may sometimes be too large to reach the entire porous framework, resulting in an erroneous value. Hence, a smaller probe molecule for BET measurements (such as hydrogen) may be required. In this study, we describe a cost-effective novel cryostat for BET measurement that can reach temperatures below the liquefaction of hydrogen gas. Temperature and cold volume of the cryostat are corrected, and all measurements are validated using a commercial device. In this way, direct observation of the hydrogen adsorption properties is possible, which can translate directly into the determination of textural properties.

A Study on the Strength Safety of an Aluminium Liner for a Hydrogen Fuel Storage Tank (수소연료 저장탱크용 알루미늄 라이너의 강도안전성에 관한 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.16-21
    • /
    • 2012
  • In this study, the strength safety for 110 liter hydrogen fuel storage tank with 70MPa filling pressure has been analyzed using a FEM technique. The strength safety of a composite fuel tank in which is fabricated by an aluminum liner of 6061-T6 and carbon fiber wound composite layers of T800-24K and T700-12K of Toray, and MR60H-24P of Mitsubishi Ray has been investigated based on the criterion of a strength safety of US DOT-CFFC and Korean Standard. The FEM computed results on the strength safety of 70MPa hydrogen gas tank showed that the hydrogen fuel storage tank in which is fabricated by T800-24K and T700-12K of Toray, and MR60H-24P of Mitsubishi Ray is safe because those two carbon fibers have very similar material properties. But, the composite storage tank with a filling pressure of 70MPa in which is fabricated by T700-12K of Toray may not guaranty the strength safety, and thus this study recommends a composite hydrogen fuel tank under 60MPa.

Criticality Safety Analysis of Spent Fuel Storage Facility for Bo-Ri Unit 1 (핵연료 저장시설의 임계 안전성 분석)

  • Dong Ha Kim;Un Chul Lee
    • Nuclear Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.86-91
    • /
    • 1982
  • In 1977, spent fuel storage capacity of Ko-Ri Unit 1 was raised to contain 4-2/3 core, by reducing the center-to-center spacing between fuel assemblies from 53.34cm to 36cm. In this paper the adequacy is discussed in detail by examining the previous design analysis report. According to the analytic method presented by Core Performance Branch, study on credible abnormal moderator density condition is performed by using KENO-IV for the redesigned spent fuel storage facility. Result shows that 36cm for the center-to-center spacing between fuel assemblies is not enough to keep the storage safe at water density of 0.1143g/㎤, which gives the maximum $K_{eff}$ 0.9958$\pm$0.0048, which exceeds the CPB regulation limit 0.98. From sensitivity study regarding to the center-to-center spacing, it should be maintained to space greater than 43cm in order to meet the CPB requirements.s.

  • PDF

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.

Effect of extraction conditions on the stability and safety of sericin

  • Ji Hae, Lee;Hyun-Bok, Kim;HaeYong, Kweon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.45 no.2
    • /
    • pp.93-98
    • /
    • 2022
  • To assess the feasibility of silk sericin for non-textile application, the storage stability and biological safety of sericin were examined. It was extracted at 37℃, 70℃, 100℃, and 121℃ for 1, 3, and 5 h to elucidate the effect of extraction condition on the stability and safety of silk sericin. The solubility was increased till approximately 26% with extraction temperature of 121℃ for 1 h. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) showed that the molecular weight distribution depended on the extraction conditions. Extracted sericin displayed typical UV absorption bands upon spectrometric analysis. To examine the reproducibility of its obtained conformation, sericin was extracted thrice and its circular dichroism (CD) spectra was measured each time. Most CD spectra showed reproducibility regardless of temperature and time except under 100℃ extraction condition. The diversity of CD spectrum showed gradual reduction and was finally coincident with extraction time from 1 to 5 h. Notably, sericin has a negative peak of approximately 200 nm attributed to random coil conformation, regardless of extraction condition. However, at the 100℃ extraction condition, sericin showed both bands to be negative bands of approximately 200 and 220 nm, respectively. Sericin was centrifuged to determine the stability of storage conditions. The sericin extracted at 100℃ and 121℃ for 1 h was found to form gel rapidly within 1 h, but at 121℃ condition, the gel fraction was approximately 20% within 1 h which retained its phase regardless of storage time. The gel fraction of sericin extracted at 100℃ for 5 h increased with time, however at the 121℃ for 5 h condition, the gel fraction was measured to be less than 10% regardless of increase in storage time. PetriflimTM AC plates test showed that sericin was safe from aerobic bacteria activity by extraction under high temperature.

A Study on the Properties of Hwangto Permeable Block Using Ferro Nickel Slag (페로니켈슬래그를 혼입한 황토투수블럭 물성에 관한 연구)

  • Kim, Soon-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.607-618
    • /
    • 2022
  • This study involves the development of a Hwangto permeable block for rainwater storage tanks. The permeable products that form continuous voids between Hwangto binders and aggregates are fine milled slag powder, which is an industrial by-product generated during the production of Hwangto and iron, and ferro nickel slag. The properties of Hwangto permeable blocks were studied using recycled resource aggregates. The target quality is based on KSF 2394. The Hwangto permeable block for a rainwater storage tank is made of water-permeable material, and the permeability of the Hwangto permeable block itself is 0.1mm/sec or higher, with a physical performance of over 5.0MPa in flexural strength and over 20.0MPa in compressive strength. The physical properties of Hwangto permeable block for rainwater storage tanks were researched and developed. In order to prevent flooding due to heavy rain in summer and the urban heat island phenomenon due to depletion of ground water, continuous pores are formed in the block to secure a permeability function to prevent rainwater from accumulating in the pavement of the floor, and to prevent slippage for comfortable and safe storage.