• Title/Summary/Keyword: saddle type coil

Search Result 6, Processing Time 0.018 seconds

$^2D$ NMR Probe Development for Investigation of Biosupramolecular Systems

  • Kim, Andre;Kang, Shin-Won;Park, Jang-Su
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.8 no.1
    • /
    • pp.55-61
    • /
    • 2004
  • Biosupramolecular systems such as biological membranes usually fluid under physiological conditions$^1$. Therefore, solid-state NMR has been used to investigate biosupramolecular systems. But solid-state NMR spectra contain a large number of overlapping resonances and are rather difficult to analyze. These problem has to be overcome by selective isotope labeling. We constructed a deuterium NMR probe for AM400 NMR spectrometer, which is mainly used for liquid samples. To overcome the fluidity problem, a saddle type coil was designed. The efficiency was systematically investigated for two kinds of coil geometry, solenoid and saddle types. Our results suggest that solenoids are superior to saddle type coils in the sensitivity. However, the letter fits better to fluid samples such as biosupramolecular systems.

  • PDF

1MVA Superconducting Generator Design (1MVA 급 초전도발전기 설계)

  • 백승규;손명환;권영길;류강식;조영식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.158-161
    • /
    • 2000
  • Generally superconducting generators(S. G.'s) will be classified into 2 types according to their field coil shape. The first one is race-trace type and the other is saddle type. Race-track type S.G.'s have almost the same structure with conventional salient pole generators which are being used as largely small scale machines with more than 4 poles. On the other hand saddle type S.G.'s correspond to conventional cylindrical generators with 2 poles used for large turbines in power plants. In this paper 1MVA S.G. with saddle type field coil is electromagnetically designed and based on the research results from development of 30kVA S.G. with race-track type field oils in our group. other parts such as cooling systems and power leads are presented.

  • PDF

Design Considerations of 2-pole Synchronous Superconducting Rotating Machine (2극 초전도 동기기 설계법 고찰)

  • Baik, S.K.;Sohn, M.H.;Lee, E.Y.;Kwon, Y.K.;Ryu, K.S.;Jo, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.865-867
    • /
    • 2001
  • Generally large synchronous rotating machines with 2 poles have more merits than the others with more than 2 poles Superconducting synchronous rotating machines also have the same tendency, but they have different structure from conventional ones because of no magnetic core inside of the rotor. As the result, design approaches of the superconducting field coils are also different, which would be classified into 2 types according to their coil shapes. The first one is race-track type and the other is saddle type Race-track type machines have almost the same structure with conventional salient pole generators which are being used as largely small scale machines with more than 2 poles. On the other hand saddle type machines correspond to conventional cylindrical generators with 2 poles used for large turbine system in power plants. In this paper several types of superconducting field coils are introduced for 2 pole superconducting machine design and then the feasibility of each type is considered. Moreover, based on the consideration. 1MVA superconducting generator(S.G.) with saddle type field coil is designed electromagnetically.

  • PDF

The Optimization Of SS-Type Deflection Yoke By Using Genetic Algorithm (유전 알고리즘을 이용한 SS형 편향코일의 형상 최적화)

  • Joo, K.J.;Yoon, I.G.;Kang, B.H.;Joe, M.C.;Hahn, S.Y.;Lee, H.B.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.971-973
    • /
    • 1993
  • Deflection Yoke(the following, DY) is the important electric device of CRT which deflects R, G, B beans influencing magnetic field produced by yoke coils. Recently, DY is designed to the saddle/saddle type of coils, being proposed for high-definite and high-efficient CRT. This paper presents the optimization of pin-sectioned saddle coil's shape for minimizing gap between desired and practical deflections of electron beams by using Genetic Algorithm. Evolution Startegy is utilized in this paper, since evolution strategy is a kind of genetic algorithms finding the optimized values by choicing the better generation with comparing the parents and their children. Here, the children are generated by only mutations from the normal random variables. Evolution strategy has shown better powerful converge rate than the other genetic algorithms becuase of using only the mutation-operator.

  • PDF

Development of Induction Heating Simulator for the Bending of Plates with Primary Curvature (1차곡을 갖는 판의 곡가공을 위한 유도가열 시뮬레이터의 개발)

  • Lee, Young-Hwa;Ha, Yun-Sok;Jang, Chang-Doo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.3
    • /
    • pp.241-248
    • /
    • 2005
  • The induction heating is more efficient for a plate bending because of its easy operation and control of working parameters compared with the heating by torch. In this study, a more efficient method was proposed for the prediction of plate bending. The existing analysis method using the axi-symmetric coil model could not handle the varying temperature during the heating and the forming process for curved plates like a saddle or a concave type curvature. The proposed method using some discrete steps in this study could overcome these difficulties and show more accurate, reasonable results in temperatures and deflections of fiat or curved plates. This method is composed of multi-disciplinary analyses such as an electro-magnetic analysis, a heat transfer analysis and a deformation analysis based on inherent strain approach.

Effects of the mascara and eye shadow on theMR image distortion (자기공명영상 왜곡에서 마스카라와 아이섀도의 영향)

  • Lee, Hyun-Yong;Shin, Oun-Jae;Park, Byung-Rae
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.25-32
    • /
    • 2005
  • Purpose : To evaluate the degree of the artifact which is caused by the mascara and the eye shadow when acquiring MR images and compare the difference of the image distortion according to the change of various pulse sequence. Material and Method : The popular domestic mascara and eye shadow products were selected from three different companies respectively and divided into two groups mascara (M1, M2, M3 ), eye shadow (E1, E2, E3). Self-designed quadrature type saddle coil which has 4 cm inside diameter, 8 cm length and which is for both Tx and Rx was used. MR image was acquired respectively after applying the mascara to the tape from study 1, the eye shadow to the tape from study 2 and adding the eye shadow to the mascara from study 3. The FSE(fast spin echo), the SE(spin echo), the GE(gradient echo) were used as pulse sequences. The degree of the image distortion which was measured from each sequence was analyzed in quality and quantity. Result : The mascara and the eye shadow caused the artifacts to the MR images partially and induced the image distortion. There was a little difference in terms of the degree of artifact according to the change of pulse sequence. From the study 3 in which the eye shadow was applied to the mascara, on the axial plane image, the width of artifact was 16.73 mm in the GE pulse sequence, 6.64 mm in the SE pulse sequence, and 6.19 mm in the FSE pulse sequence. The degree of the artifact appeared highly in order of the GE, the SE and the FSE. On the sagittal plane image, the length of artifact was 22.84 mm in the GE, 17.81 mm in the SE and it appeared highly with the SE and the FSE technique order. Conclusion : When examining the eyeball and the brain of a woman with the mascara and the eye shadow, we have to consider that the artifact caused by them can have an effect on the image diagnosis. We concluded that it is more suitable for a brain and a eyeball T2 emphasizing image to use the FSE technique than the GE technique.

  • PDF