• 제목/요약/키워드: sPMU

검색결과 35건 처리시간 0.031초

견실한 전력계통 상태벡터 계산을 위한 동기 페이저 측정기 최적배치 (Optimal Placement of Synchronized Phasor Measurement Units for the Robust Calculation of Power System State Vectors)

  • 조기선;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.75-79
    • /
    • 2000
  • This paper proposes the optimal placement with minimum set of Phasor Measurement Units (PMU's) using tabu search and makes an alternative plan to secure the robustness of the network with PMU's. The optimal PMU Placement (OPP) problem is generally expressed as a combinatorial optimization problem subjected to the observability constraints. Thus, it is necessary to make a use of an efficient method in solving the OPP problem. In this paper, a tabu search based approach to solve efficiently this OPP problem proposed. The observability of the network with PMU's is fragile at any single PMU contingency. To overcome the fragility, an alternative scheme that makes efficient use of the existing measurement system in power system state estimation proposed. The performance of the proposed approach and the alternative scheme is evaluated with IEEE sample systems.

  • PDF

대공유도무기 패트리어트(2)

  • 김동윤
    • 국방과기술
    • /
    • 7호통권221호
    • /
    • pp.44-51
    • /
    • 1997
  • 지난호에 S-300V를 소개하면서 S-300 PMU-1 사진을 게재하여 이를 바로 잡습니다. S-300V는 이동형 대탄도탄 유도무기체계로 개발되었고 S-300 PMU-1은 원래 대항공기 방어를 주임무로 하는 드립니다. S-300 PMU 체계의 최신 개량형으로 서로 상이한 무기체계임을 알려드립니다. 아울러 패트리어트와 S-300V의 기사를 나누어 게재했으면 하는 의견이있어 이번호에는 패트리어트를 소개하고 8월호에 S-300V를 게재코자 합니다.

  • PDF

전력계통의 페이저 측정기 최적배치 (Optimal Placement of the Phasor Measurement Units in Power System)

  • 김재훈;조기선;김회철;신중린
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF

전기동력 무인항공기용 PMU의 개선 및 제작에 대한 연구 (Study on Production of Power Monitoring Unit for Electric Propulsion UAV)

  • 강진명;정진석;강범수;김장목
    • 한국항공우주학회지
    • /
    • 제45권2호
    • /
    • pp.140-147
    • /
    • 2017
  • 본 논문에서는 전기추진 무인항공기의 동력원으로 주로 사용되고 있는 리튬폴리머 배터리의 상태 모니터링을 위해 기존에 자체 개발한 동력 모니터링 장치인 PMU의 개선 및 제작에 관하여 기술하였다. 개선된 PMU는 비행에 필요한 다양한 센서와 모터의 구동에 안정적인 전압과 전류를 제공하며 모니터링 채널과 온도센서의 추가로 상태 모니터링의 정밀도가 향상되었다. 지상 시험환경을 통해 무인항공기에 탑재되는 PMU의 전압전류 측정값을 보정하고 실제 비행시험을 통해 개선된 성능을 확인하였다.

Complete and Incomplete Observability Analysis by Optimal PMU Placement Techniques of a Network

  • Krishna, K. Bala;Rosalina, K. Mercy;Ramaraj, N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1814-1820
    • /
    • 2018
  • State estimation of power systems has become vital in recent days of power operation and control. SCADA and EMS are intended for the state estimation and to communicate and monitor the systems which are operated at specified time. Although various methods are used we can achieve the better results by using PMU technique. On placing the PMU, operating time is reduced and making the performance reliable. In this paper, PMU placement is done in two ways. Those are 'optimal technique with pruning operation' and 'depth of unobservability' considering incomplete and complete observability of a network. By Depth of Unobservability Number of PMUs are reduced to attain Observability of the network. Proposed methods are tested on IEEE 14, 30, 57, SR-system and Sub systems (1, 2) with bus size of 270 and 444 buses. Along with achieving complete observability analysis, single PMU loss condition is also achieved.

동기페이저측정기를 활용한 전력계통 상태벡터 결정을 위한 병렬처리기법 (Parallel Processing Techniques to Determine State Vectors of a Power System using PMU)

  • 이기송;이찬주;조기선;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.72-74
    • /
    • 2000
  • This paper presents the linear model of the measurement system with Phasor Measurement Units (PMU's) and the parallel processing technique to determinate state vectors of a power system. The conventional model of the PMU measurement system is in a dilemma that it is not applicable to optimal PMU placements and it needs more PMU to apply this model. In order to improve this defect, in this paper, the extended linear model which adaptable to optimal PMU placements considering the feature of zero injection bus is proposed. Because the proposed model is expressed as over-determined measurement equation, the efficient algorithm is needed. This paper proposed the partitioning scheme and the process algorithm for parallel determinating state vectors of a power system efficiently. The performance of the proposed linear model and the parallel processing algorithm is evaluated with IEEE sample systems.

  • PDF

PMU를 이용한 변전소 상태 해석에 관한 연구 (A Study on State Analysis of Substation Using PMU)

  • 김태희;이경민;박철원;전동훈;권대윤;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제37권3호
    • /
    • pp.304-308
    • /
    • 2024
  • In this paper, in order to analyze the PMU data of the accident section, we collected the raw data of a total of 35 PMU installed at the Yeonggwang substation and tried to find a way to analyze the data, and analyzed the data using Excel format and formula. As a result, the three-phase voltage and current data of the PMU were calculated using formulas in Excel and interpreted as effective and reactive power, and it was possible to check the effective and reactive power of the accident section through the graph to see why it was different from before the accident. As a result, it was confirmed that each power was greatly reduced in the graph of the effective and reactive power of the accident section, and it was confirmed that the loss occurred as the power of the accident section was greatly reduced.

빛 에너지 하베스팅을 위한 전력관리회로 (A Power Management Unit for Solar Energy Harvesting)

  • 윤은정;황인호;박종태;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 추계학술대회
    • /
    • pp.267-271
    • /
    • 2012
  • 본 논문에서는 빛 에너지 하베스팅을 위한 전력관리회로를 제안한다. 솔라셀이 센서노드가 동작할 수 있는 충분한 전압을 출력할 경우는 Power Management Unit(PMU)를 통해 직접 솔라셀의 에너지를 부하로 공급하고, 솔라셀의 출력전압이 센서노드가 동작하기에 충분치 않다면 voltage booster(VB)를 통해 충분한 전압까지 승압하여 이를 PMU를 통해 부하로 공급하도록 설계하였다. 설계된 회로를 0.18um CMOS 공정으로 제작하여 측정한 결과, 솔라셀의 에너지를 PMU를 통해 직접 부하로 공급하는 경우는 보다 많은 에너지가 부하로 공급되었고, VB를 이용하여 PMU를 통해 부하로 에너지를 공급하는 경우는 낮은 전압을 출력하는 초소형 솔라셀에도 적용이 가능하였고 낮은 조도에서도 에너지 공급이 가능하였다.

  • PDF

페이저 측정 시스템의 측정기 최적배치 (Meter Optimal Placement in Measurement System with Phasor Measurement Unit)

  • 김재훈;조기선;김회철;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1195-1198
    • /
    • 1999
  • This paper presents optimal placement of minimal set of phasor measurement units(PMU's) and observability of measurement system with PMU. By using the incidence matrix symbolic method which directly assigns measurement and pseudo-measurement to incidence matrix, it is much simpler and easier to analyze observability. The optimal PMU set is found through the simulated-annealing(SA) and the direct combinational method. The cooling schedule parameter which is suitable to the property of problem to solve is specified and optimal placement is proven by presented direct combinational method. Search spaces are limited within reasonable feasible solution region to reduce a unnecessary one in the SA implementation based on global search. The proposed method presents to save CPU time and estimate state vectors based on optimal PMU set.

  • PDF

Payload Management Unit design of MSC (Multi-Spectral Camera)

  • Kong, Jong-Pil;Yong, Sang-Soon;Heo, Haeng-Pal;Kim, Young-Sun;Park, Jong-Uk;Youn, Heong-Sik
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1108-1110
    • /
    • 2003
  • MSC(Multi-Spectral Camera) which is a unique payload for KOMPSAT-2, comprises main three subsystems of PMU(Paylaod Management Unit), EOS(Electro -Optical Subsystem) and PDTS(Payload Data Transmission Subsystem). The PMU, as a main controller of MSC, performs major tasks such as interfacing with S/C(Space Craft), controlling the MSC operation, distributing and controlling of operating power to all MSC including thermal unit, etc. In this paper the H/W configurations as well as the functions of PMU are introduced and possible changes for the future development are suggested.

  • PDF