• 제목/요약/키워드: sFlow

Search Result 13,388, Processing Time 0.042 seconds

A Study on the Phenomena of Dust Removal by the Layout Changes in the Turbulent Type Clean Room (난류형 클린룸내의 Layout 변화에 따른 분진제거 특성에 관한 연구)

  • Kim, Yeon-Hui
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.41
    • /
    • pp.80-87
    • /
    • 2007
  • The purpose of this paper is to investigate the removal efficiency of fine dusts as the configuration condition of machinery and equipments in Clean Room and to analyze the flowing behaviors of fine dusts as the layout of Clean Room. The layout of the Clean Room was classified into side layout type, 2 center line type and center concentration type layout, and the flow rates used in this research were 0.22m/s, 0.44m/s and0.80m/s. Dust removal efficiency as layout change was decreased 37% for side layout type, 31% for 2 centerline type and 20% for center concentration type layout at the flow rate of 0.22m/s, compared with the state without machinery and equipments in Clean Room. The efficiency was decreased 42% for side layout type,22% for 2 center line type and 8% for center concentration type layout at the flow rate of 0.44m/s, and decreased 20% for side layout type, 18% for 2 center line type and 10% for center concentration type layout at the flow rate of 0.80m/s. According to the result of dust removal behavior, $0.3\mum$, $1\mum$and $3\mum$dust except for $5\mum$showed the higher change of the behavior in side layout type than in center concentration type layout due to the change of air flow. It was confirmed that removal behavior depends on the layout of machinery and equipments as the dust size decreases.

  • PDF

A Effects of Democratic and Autocratic Behavior Types of Dance Art Instructors in Elementary on Class Satisfaction : Focused on Mediations of Flow and Perceived Competence (초등무용교육에서의 민주적, 권위적 행동유형이 수업만족도에 미치는 영향 : 몰입과 지각된 유능감의 이중매개효과를 중심으로)

  • WOO, Jung-Wook;MUN, SunHo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.3
    • /
    • pp.701-712
    • /
    • 2016
  • The purpose of this study was to investigate the effect of democratic and autocratic behavior type of dance art instructors in elementary dance education on class satisfaction focused on mediations of flow and perceived competence. A total of 500 questionnaires were distributed but insincerely replied or double-replied questionnaires were excluded and finally 453 questionnaires were analyzed for this study. For the analysis of the data, SPSS 18.0 version was used and double mediation model operating in serial, proposed by Hayes and a bootstrapping method were used. First, instructor's democratic behavior type was statistically positive effect on class satisfaction. However autocratic behavior type was statistically negative effect. Second, the indirect effect of instructor's democratic type and autocratic behavior type on class satisfaction through the flow were statistically positive significant. Third, the indirect effect of instructor's democratic behavior type on class satisfaction through the perceived competence was statistically significant. However autocratic behavior type was statistically negative effect. Lastly, the indirect effect of instructor's democratic and autocratic behavior types on class satisfaction through the flow and perceived competence were statistically positive significant.

Defending HTTP Web Servers against DDoS Attacks through Busy Period-based Attack Flow Detection

  • Nam, Seung Yeob;Djuraev, Sirojiddin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.7
    • /
    • pp.2512-2531
    • /
    • 2014
  • We propose a new Distributed Denial of Service (DDoS) defense mechanism that protects http web servers from application-level DDoS attacks based on the two methodologies: whitelist-based admission control and busy period-based attack flow detection. The attack flow detection mechanism detects attach flows based on the symptom or stress at the server, since it is getting more difficult to identify bad flows only based on the incoming traffic patterns. The stress is measured by the time interval during which a given client makes the server busy, referred to as a client-induced server busy period (CSBP). We also need to protect the servers from a sudden surge of attack flows even before the malicious flows are identified by the attack flow detection mechanism. Thus, we use whitelist-based admission control mechanism additionally to control the load on the servers. We evaluate the performance of the proposed scheme via simulation and experiment. The simulation results show that our defense system can mitigate DDoS attacks effectively even under a large number of attack flows, on the order of thousands, and the experiment results show that our defense system deployed on a linux machine is sufficiently lightweight to handle packets arriving at a rate close to the link rate.

A Study of Flow-based QoS Management in Packet Transport Network (패킷 전송망에서의 플로우 기반 QoS 관리 방안 연구)

  • Choi, Chang-Ho;Kim, Whan-Woo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • As a demand of IP based packet service is increasing, transport network is evolving from circuit based transport technology using TDM to Ethernet based packet transport technology. In this paper we introduce packet transport network based on PBB-TE and MPLS-TP and propose a quality of service(QoS) management scheme to satisfy various user requirements in packet transport network. The proposed flow-based QoS management scheme guarantees that per-flow bandwidth control satisfies the predefined QoS requirement perfectly under bandwidth congestion condition by using perflow and per-PTL tunnel management. In order to evaluate the proposed scheme we defined flow and PTL tunnel per input frame and configured QoS parameters for each flow and PTL tunnel respectively. Simulation was done by using OPNET modeler 16.0 version.

Quantitative Analysis of Fluid Velocity and Signal Loss of the TOF-MRA in a 3.0T MR System: Using the Flow Rate Control Phantom (3.0T MR system에서 TOF-MRA의 유체속도와 신호소실의 정량분석 : 유속조절팬텀 이용)

  • Back, Sang-Hoon;Jeong, Jin-Heon;Lee, Ye-Eun;Gwak, Min-Young;Yoon, Jun;Jung, Dabin;Oh, Hyun-Sik;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.965-973
    • /
    • 2020
  • The purpose of this study was to quantitatively correlate the change of flow velocity and signal voiding in TOF-MRA. We made our phantom to control the flow velocity, and changed the flow velocity in 16 steps from 8.0 to 127.3 mc/s. The TOF-MRA test was performed using a 3.0T MRI system and the signal intensity was measured by classifying the signal voiding length and image into the In flow, Mid flow, and Out flow. The length of signal voiding was the longest when the flow velocity was 127.3 cm/s and the signal intensity decreased with increasing flow velocity(p<0.05). In flow(-.547) and Mid flow(-.643) were negatively correlated with flow velocitys(p<0.05). In conclusion, it was confirmed that the increase in flow velocity was a major factor causing signal voiding in TOF-MRA. In the future, this study will provide basic data when studying sequences and parameters to reduce signal voiding in models with a high flow velocity.

Effect of LiBr solution flow rates in commercial absorption chiller (상용 흡수식 냉동기에서 LiBr 수용액 유량변화에 따른 영향)

  • Choi, S.H.;Chung, B.C.;Nam, L.W.;Jurng, J.;Chin, S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.292-297
    • /
    • 2001
  • This paper discusses the effect of varying LiBr solution circuits flow rates for a direct fired double effect commercial absorption chiller in the parallel flow configuration. The effects of solution flow rates have been investigated for generator, condenser, solution heat exchanger, absorber and evaporator. According to the result of this work, it was found that sensible heat rate of generator increases and refrigerant vapor generated in that decreases when inlet solution flow rate of that increases. As solution flow rate of absorber increases, the degree of superheat increases because of decreasing solution heat exchanger efficiency. The flashing vapor at the top of absorber increases in proportion to the degree of superheat whileas decreases cooling capacity inversely.

  • PDF

Network analysis by signal-flow graph (Signal-flow graph에 의한 회로분석)

  • Hyung Kap Kim
    • 전기의세계
    • /
    • v.17 no.2
    • /
    • pp.11-15
    • /
    • 1968
  • One of the most important methods used in the modern analysis of linear networks and systems is the signal flow graph technique, first introduced by S.J. Mason in 1953. In essence, the signal-flow graph technique is a graphical method of solving a set of simultaneous. It can, therefore, be regarded as an alternative to the substitution method or the conventional matrix method. Since a flow-graph is the pictorial representation of a set of equations, it has an obvious advantage, i.e., it describes the flow of signals from one point of a system to another. Thus it provides cause-and-effect relationship between signals. And it often significantly reduces the work involved, and also yields an easy, systematic manipulation of variables of interest. Mason's formula is very powerful, but it is applicable only when the desired quantity is the transmission gain between the source node and sink node. In this paper, author summarizes the signal-flow graph technique, and stipulates three rules for conversion of an arbitrary nonsource node into a source node. Then heuses the conversion rules to obtain various quantities, i.e., networks gains, functions and parameters, through simple graphical manipulations.

  • PDF

Scalable Network Architecture for Flow-Based Traffic Control

  • Song, Jong-Tae;Lee, Soon-Seok;Kang, Kug-Chang;Park, No-Ik;Park, Heuk;Yoon, Sung-Hyun;Chun, Kyung-Gyu;Chang, Mi-Young;Joung, Jin-Oo;Kim, Young-Sun
    • ETRI Journal
    • /
    • v.30 no.2
    • /
    • pp.205-215
    • /
    • 2008
  • Many control schemes have been proposed for flow-level traffic control. However, flow-level traffic control is implemented only in limited areas such as traffic monitoring and traffic control at edge nodes. No clear solution for end-to-end architecture has been proposed. Scalability and the lack of a business model are major problems for deploying end-to-end flow-level control architecture. This paper introduces an end-to-end transport architecture and a scalable control mechanism to support the various flow-level QoS requests from applications.

  • PDF

Hyperbolicity Breaking Model and Drift-Flux Model for the Prediction of Flow Regime Transition after Inverted Annular Flow

  • Jeong, Hae-Yong;No, Hee-Cheon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.456-461
    • /
    • 1995
  • The concept of hyperbolicity breaking is applied to predict the flow regime transition from inverted annular flow (IAF) to agitated inverted annular flow (AIAF). The resultant correlation has the similar form to Takenaka's empirical one. To validate the proposed model, it is applied to predict Takenaka's experimental results using R-113 refrigerant with four different tube diameters of 3, 5, 7 and 10 mm. The proposed model gives accurate predictions for the tube diameters of 7 and 10 min. As the tube diameter decreases, the differences between the predictions and the experimental results increase slightly. The flow regime transition from AIAF to dispersed flow (DF) is described by the drift flux model.

  • PDF