• 제목/요약/키워드: s-t Cut

검색결과 300건 처리시간 0.033초

Quality Characteristics of Fermented Pork with Korean Traditional Seasonings (한국 전통 양념을 이용한 발효 돼지고기의 품질 특성)

  • Jin, S.K.;Kim, C.W.;Lee, S.W.;Song, Y.M.;Kim, I.S.;Park, S.K.;Hah, K.H.;Bae, D.S.
    • Journal of Animal Science and Technology
    • /
    • 제46권2호
    • /
    • pp.217-226
    • /
    • 2004
  • This study was canied out to evaluate the quality characteristics of the fermented pork with Korean traditional seasonings. The samples, outside muscle of pork ham were cut to cube(7 ${\times}$ 12 ${\times}$ 2cm) and five Korean traditional seasonings such as garlic paste(TI), pickled Kimchi(T2), pickled Kimchi juice(T3), soybean paste(T4), red pepper paste(T5) were seasoned by the proportions of meat to seasonings(1 : 1). The seasoned samples were fennented at - 1 ${\pm}$ 1$^{\circ}C$ for 20 days. According to proximate composition analysis, all pork samples contained protein 20 ${\sim}$ 22%, fat 3 ${\sim}$ 5%, moisture 64 ${\sim}$ 70% and ash 1.8 ${\sim}$ 2.0%. However, T5 had high crude fat level and relatively low moisture content. The highest pH among treatments was shown in TI whereas T3 showed the lowest. Water holding capacity(WHC) of T4 and T5 were higher, while those values were lower in T3 compared with other treatment. Shear force value was the highest in T5, while it was the lowest in T4. TBARS value of T3 was the highest, while that was the lowest in T4. Moreover the highest VBN value was observed in T4 due to fermentation of soy protein. However, the lowest VBN value shown in Tl indicated the inhibition of protein degradation by the garlic. The highest saccarinity was shown in T5 but it was the lowest of in T3. Salinity was shown to be high in T2 and low in T5. $L^*$ values of T4 was higher both at the surface and inner side of samples than the others but T5 showed the lowest value. T2 showed the highest $a^*$ value but T4 and T5 showed the lowest. In the result of sensory evaluation for cooked meat, T5 had the highest score in all item including overall acceptability, while T4 had the lowest score. Unsaturated fatty acid(UFA) ratio of T5 and n were 72.16 and 69.93 respectively, and the ratio of UFA/Saturated fatty acid(SFA) were higher in the order of T5 >T4> T3 >Tl >T2. Overall quality characteristics were higher in the order of T5 >T2 >Tl >T4 >T3.

Diagnostic Performance of Diffusion-Weighted Steady-State Free Precession in Differential Diagnosis of Neoplastic and Benign Osteoporotic Vertebral Compression Fractures: Comparison to Diffusion-Weighted Echo-Planar Imaging

  • Shin, Jae Ho;Jeong, Soh Yong;Lim, Jung Hyun;Park, Jeongmi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권3호
    • /
    • pp.154-161
    • /
    • 2017
  • Purpose: To evaluate the diagnostic performance of diffusion-weighted steady-state free precession (DW-SSFP) in comparison to diffusion-weighted echo-planar imaging (DW-EPI) for differentiating the neoplastic and benign osteoporotic vertebral compression fractures. Materials and Methods: The subjects were 40 patients with recent vertebral compression fractures but no history of vertebroplasty, spine operation, or chemotherapy. They had received 3-Tesla (T) spine magnetic resonance imaging (MRI), including both DW-SSFP and DW-EPI sequences. The 40 patients included 20 with neoplastic vertebral fracture and 20 with benign osteoporotic vertebral fracture. In each fracture lesion, we obtained the signal intensity normalized by the signal intensity of normal bone marrow (SI norm) on DW-SSFP and the apparent diffusion coefficient (ADC) on DW-EPI. The correlation between the SI norm and the ADC in each lesion was analyzed using linear regression. The optimal cut-off values for the diagnosis of neoplastic fracture were determined in each sequence using Youden's J statistics and receiver operating characteristic curve analyses. Results: In the neoplastic fracture, the median SI norm on DW-SSFP was higher and the median ADC on DW-EPI was lower than the benign osteoporotic fracture (5.24 vs. 1.30, P = 0.032, and 0.86 vs. 1.48, P = 0.041, respectively). Inverse linear correlations were evident between SI norm and ADC in both neoplastic and benign osteoporotic fractures (r = -0.45 and -0.61, respectively). The optimal cut-off values for diagnosis of neoplastic fracture were SI norm of 3.0 in DW-SSFP with the sensitivity and specificity of 90.4% (95% confidence interval [CI]: 81.0-99.0) and 95.3% (95% CI: 90.0-100.0), respectively, and ADC of 1.3 in DW-EPI with the sensitivity and specificity of 90.5% (95% CI: 80.0-100.0) and 70.4% (95% CI: 60.0-80.0), respectively. Conclusion: In 3-T MRI, DW-SSFP has comparable sensitivity and specificity to DW-EPI in differentiating the neoplastic vertebral fracture from the benign osteoporotic vertebral fracture.

Cat Behavior Pattern Analysis and Disease Prediction System of Home CCTV Images using AI (AI를 이용한 홈CCTV 영상의 반려묘 행동 패턴 분석 및 질병 예측 시스템 연구)

  • Han, Su-yeon;Park, Dea-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제26권9호
    • /
    • pp.1266-1271
    • /
    • 2022
  • Cats have strong wildness so they have a characteristic of hiding diseases well. The disease may have already worsened when the guardian finds out that the cat has a disease. It will be of great help in treating the cat's disease if the owner can recognize the cat's polydipsia, polyuria, and frequent urination more quickly. In this paper, 1) Efficient version of DeepLabCut for pose estimation, 2) YOLO v4 for object detection, 3) LSTM is used for behavior prediction, and 4) BoT-SORT is used for object tracking running on an artificial intelligence device. Using artificial intelligence technology, it predicts the cat's next, polyuria and frequency of urination through the analysis of the cat's behavior pattern from the home CCTV video and the weight sensor of the water bowl. And, through analysis of cat behavior patterns, we propose an application that reports disease prediction and abnormal behavior to the guardian and delivers it to the guardian's mobile and the server system.

Effect of Paper Mulberry Bast Fiber's Length on the Quality of the Hand-made Korean Paper (닥나무 인피섬유장이 지질에 미치는 영향)

  • Cheon, Cheol;Lee, Myung Ki
    • Journal of Conservation Science
    • /
    • 제5권1호
    • /
    • pp.94-104
    • /
    • 1996
  • This study was carried on paper mulberry bast fibers, which were cut in the length of it's chip by three kinds. And they cooked by sodium hydroxide (NaOH) and ammonium oxalate (AMOX), and pulping process was studied to inquire some properties of hand made papers. The results were as follows. AMOX pulps had $10\~17\%$ higher than NaOH, but amounts of the residual lignin of it's pulps and residual ash were high, and it surely can't be superior. In the freeness of pulps, AMOX pulps were higher than that of NaOH, but they showed tendency to opposite in view of relation of chip's length kinds. For the AMOX pulps, the physical characteristics test results were higher long fiber pulps than short fiber pulps. Specially, in folding endurance long fiber pulps were a very strong. NaOH pulp's physical characteristics test had shown results that were opposite of there of the AMOX pulps, if the length of the fiber is longer, the strengthts generally decreased. To get the optimum fiber's length according to use of paper and pulping method, they must be fractionate chip's length. The long fibers in NaOH pulps affected the paper quality greatly to length of chips.

  • PDF

Reduced Telomere Length in Colorectal Carcinomas

  • Feng, Tong-Bao;Cai, Lei-Ming;Qian, Ke-Qing;Qi, Chun-Jian
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권2호
    • /
    • pp.443-446
    • /
    • 2012
  • Purpose: Telomeres play a key role in the maintenance of chromosome integrity and stability, and telomere shortening is involved in initiation and progression of malignancies. The aim of this study was to determine whether telomere length is associated with the colorectal carcinoma. Patients and methods: A total of 148 colorectal cancer (CRC) samples and corresponding adjacent non-cancerous tissues were evaluated for telomere length, P53 mutation, and cyclooxygenase-2 (COX-2) mutation detected by fluorescent immunohistochemistry. Telomere length was estimated by real-time PCR. Samples with a T/S>1.0 have an average telomere length greater than that of the standard DNA; samples with a T/S<1.0 have an average telomere length shorter than that of the standard DNA. Results: Telomeres were shorter in CRCs than in adjacent tissues, regardless of tumor stage and grade, site, or genetic alterations (P=0.004). Telomere length in CRCs also had differences with COX-2 status (P=0.004), but did not differ with P53 status (P=0.101), tumor progression (P=0.244), gender (P=0.542), and metastasis (P=0.488). There was no clear trend between T/S optimal cut-off values (<1 or > 1) and colorectal tumor progression, metastasis, gender, P53 and COX-2 status. Conclusion: These findings suggesting that telomere shortening is associated with colorectal carcinogenesis but does not differ with tumor progression, gender, and metastasis.

Microstructural Changes of OFC according to the Processing Number of Multi-Axial Diagonal Forging (MADF) (다축대각단조(MADF) 가공횟수에 따른 OFC의 미세조직 변화)

  • Kim, S.T.;Kwon, S.C.;Kim, D.V.;Lee, S.;Choi, S.H.;Jeong, H.T.
    • Transactions of Materials Processing
    • /
    • 제27권6호
    • /
    • pp.347-355
    • /
    • 2018
  • This study investigated the effects of the processing number of multi-axial diagonal forging (MADF) on the microstructural changes of OFC fabricated by MADF processes. The as-extruded OFC was cut to $25mm^3$ cube for the MADF processes. The MADF process consists of plane forging with a thickness reduction of 30% and diagonal forging with a diagonal forging angle of $135^{\circ}$. In order to analyze the microstructural evolutions according to the number of repetitions, 1, 2, 3 and 4 cycles of the MADF process were performed. OFC specimens were successfully deformed without surface cracking for up to 4 cycles of MADF. The grain size, average misorientation and average grain orientation spread (GOS) of MADF processed materials were analyzed using EBSD technique and their Vicker's hardness were also measured. The results showed that MADF process effectively refined the microstructure of OFC with initial average grain size of $84.2{\mu}m$. The average grain sizes of specimens MADF processed for 1, 2, 3, 4 cycles were refined to be $8.5{\mu}m$, $2.2{\mu}m$, $1.5{\mu}m$, $1.1{\mu}m$, respectively. The grain refinement seemed to be saturated when OFC was MADF processed over 2 cycles. In the case of specimens subjected to two or more cycles of MADF, the degree of decrease in average grain size was drastically reduced as the number of cycles increased due to softening phenomena such as dynamic recovery or dynamic recrystallization during processing. The degree of increase in average Vicker's hardness was also dramatically reduced as the number of cycles increased due to the same reason.

Studies on the Fabrication of 0.2 ${\mu}m$Wide-Head T-Gate PHEMT′s (0.2 ${\mu}m$ Wide-Head T-Gate PHEMT 제작에 관한 연구)

  • Jeon, Byeong-Cheol;Yun, Yong-Sun;Park, Hyeon-Chang;Park, Hyeong-Mu;Lee, Jin-Gu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • 제39권1호
    • /
    • pp.18-24
    • /
    • 2002
  • n this paper, we have fabricated pseudomorphic high electron mobility transistors (PHEMT) with a 0.2 ${\mu}{\textrm}{m}$ wide-head T-shaped gate using electron beam lithography by a dose split method. To make the T-shape gate with gate length of 0.2 ${\mu}{\textrm}{m}$ and gate head size of 1.3 ${\mu}{\textrm}{m}$ we have used triple layer resist structure of PMMA/P(MMA-MAA)/PMMA. The DC characteristics of PHEMT, which has 0.2 ${\mu}{\textrm}{m}$ of gate length, 80 ${\mu}{\textrm}{m}$ of unit gate width and 4 gate fingers, are drain current density of 323 ㎃/mm and maximum transconductance 232 mS/mm at $V_{gs}$ = -1.2V and $V_{ds}$ = 3V. The RF characteristics of the same device are 2.91㏈ of S21 gain and 11.42㏈ of MAG at 40GHz. The current gain cut-off frequency is 63GHz and maximum oscillation frequency is 150GHz, respectively.ively.

A Study on Korean Man's Head Ornaments in the Joseon Dynasty - Focusing on Pungjam and Kwanja - (조선시대 남자(男子)의 수식(首飾) 연구(II) - 풍잠(風簪)과 관자(貫子)를 중심(中心)으로 -)

  • Chang, Sook-Whan
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • 제12권2호
    • /
    • pp.1-20
    • /
    • 2010
  • This thesis is about "manggon" that holds down man's top knot hair and its accessaries "pungjam", "kwanja". manggon was seen first time in the mural of Donwhang kae won chon bo during T'ang period (713-756). The "Tu Aek Ra" manggon shown in this mural would be the origin and beginning of maggon's usage. Also the "Sha" that was placed on top of the hair for decoration purpose is believed to be a former form of "manggon" Before the short hair cut was enforced, wearing the "kwan"(head gear) was considered as an impotant etiguette. Thus the head gear was treasured and the manggon which was the most essential piece to cover down the hair before to put on the head gear was regarded as the most important piece. However, since the manggon was tied very tightly around the forehead, manggon caused some sickness. From my private collections of man's head gears and ornament, 121 items were selected and used for analysis and the followings were found: 1. Pungjam was divided into 8 categories according to its shape and a research was made on its unique structural characteristic on each categories. 2. Kwanja's material and design that were used are all in accordance to the historical recordings.

  • PDF

The design of a 920MHz compact RFID reader antenna of slot structure using the Taguchi's Method (Slot 구조를 이용한 920MHz 소형 RFID 리더 안테나 다구찌설계 연구)

  • Kwon, So-Hyun;Ko, Jae-Hyeong;Kim, Hyeong-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.289-292
    • /
    • 2009
  • In this paper, an optimum design center frequency proposes portable RFID reader antenna that is 920MHz frequency using the Taguchi's Method. Proposed antenna is cut corner of opposite angle and it's structure that have slots in four sides microstrip patch of a perfect square shape. This slot structure can miniaturize microstrip patch antenna and confirmed through an experiment that size of antenna about 18% decreases than structure that slot does not exist. Because compact antenna that have structure of slot changes according to complex design variables, analysis and experimental design for minimization of experiment number of times are required for optimum antenna design. In this research, designed antenna that have optimum structure when introduce and designs table of orthogonal arrays of the Taguchi's Method been experimental design that can minimize analysis and experiment number of times, achieve responsiveness analysis of main elements and analyzes the effect and minimizes design repeat with analysis result. Presented experiment result about antenna special quality that permittivity is 4.4 and manufactures to board of Epoxy 3.2T.

  • PDF

Fabrication of Transimpedance Amplifier Module and Post-Amplifier Module for 40 Gb/s Optical Communication Systems

  • Lee, Jong-Min;Min, Byoung-Gue;Kim, Seong-Il;Lee, Kyung-Ho;Kim, Hae-Cheon
    • ETRI Journal
    • /
    • 제31권6호
    • /
    • pp.749-754
    • /
    • 2009
  • The design and performance of an InGaAs/InP transimpedance amplifier and post amplifier for 40 Gb/s receiver applications are presented. We fabricated the 40 Gb/s transimpedance amplifier and post amplifier using InGaAs/InP heterojunction bipolar transistor (HBT) technology. The developed InGaAs/InP HBTs show a cut-off frequency ($f_T$) of 129 GHz and a maximum oscillation frequency ($f_{max}$) of 175 GHz. The developed transimpedance amplifier provides a bandwidth of 33.5 GHz and a gain of 40.1 $dB{\Omega}$. A 40 Gb/s data clean eye with 146 mV amplitude of the transimpedance amplifier module is achieved. The fabricated post amplifier demonstrates a very wide bandwidth of 36 GHz and a gain of 20.2 dB. The post-amplifier module was fabricated using a Teflon PCB substrate and shows a good eye opening and an output voltage swing above 520 mV.