• 제목/요약/키워드: s correlation coefficients

검색결과 2,125건 처리시간 0.031초

가축분뇨수의 색소오염물질 분해과정 측정 영상처리 시스템 (Image Processing System for Measuring the Chromatophore Pollution Solution of and Animal Slurry Using Optical-Density)

  • 이대원;김현태;김용석;민병로;이강춘;박은석;한정환;이수희;김정동
    • 한국축산시설환경학회지
    • /
    • 제7권2호
    • /
    • pp.103-110
    • /
    • 2001
  • This study conducted to monitor decomposition process of the charomatophore pollution solution of an animal slurry by using a CCD camera. After the solution was put into test tube, the images(R, G, B, H, L, S) values of the solution were measured by the imgae processing system, and those of it\`s optical density were measured for three hours to be decomposed by microscopic organism. The values of measured for three hours to be decomposed by microscopic organism. The values of measured images(R, G, B, H, L, S) were analysed and compared with those of the optical density. Some of the results are as follows. 1. High correlation coefficients, which analyzed by using data on linear equations, were 0.9557 and 0.9672. They were decreased regularly in this R-value experiment of RGB level. The microscopic organism in this experiment was effective for decomposition of the red charomatophore pollution solution. 2. The values of all correlation coefficients from relationship between RGB-value and optical density were more than 0.95 except H-values. RGB-values, which were average values of summed R, G, B values, had correlation coefficients of 0.9863, 0.9937. These results showed so good relationship that decomposition process of charomatophore pollution solution could be monitored by a image processing system.

  • PDF

마이크로관 내 증발열전달에 관한 연구 (A Study on the Evaporative Heat Transfer in Microtubes)

  • 황윤욱;김주혁;김민수
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1113-1122
    • /
    • 2005
  • The experimental heat transfer coefficients have been measured for two-phase convective boiling in two circular microtubes with inner diameters of $430{\mu}m\;and\;792{\mu}m$. While the heat transfer was greatly affected by the heat flux in the low quality region, the mass flux played a role in the high quality region. The smaller microtube had greater heat transfer coefficients. When the heat flux is varied from $20kW/m^2\;to\;30kW/m^2\;at\;G=240kg/m^2s$, the difference between the average heat transfer coefficients of the test tube $A(D_i=430{\mu}m)$ and the test tube $B(D_i=792{\mu}m)$ changes from $32.5\%\;to\;52.1\%$. At $G=370kg/m2^s$, the difference between the average heat transfer coefficients changes from $47.0\%\;to\;53.8\%$. A new correlation for the evaporative heat transfer coefficients in microtubes was developed by considering the following factors; the laminar flow heat transfer coefficient of liquid-phase flow, the enhancement factor of the convective heat transfer, and the nucleate boiling correction factor. The correlation developed in this study predicts the experimental heat transfer coefficients within an absolute average deviation of $8.4\%$.

선박 조종성능 연구를 위한 선체형상 파라메터와 유체력미계수와의 관계분석 (The study on ship's manoeuvrability through the analysis of the relationship between hydrodynamic coefficient and ship hull parameter)

  • 임남균
    • 한국항해항만학회지
    • /
    • 제29권8호
    • /
    • pp.667-671
    • /
    • 2005
  • 이 연구는 선박 설계 초기단계에서 선형 변화에 따른 선박 조종성능 추정에 관한 내용을 다루었다. 선박제원을 대표하는 파라메터 그리고 선미형상의 변화를 민감하게 반영할 수 있는 새로운 파라메터를 선정하는 작업을 수행하였다. 이렇게 선정된 파라메터와 유체력 미계수와의 상관관계를 알아보기 위하여 구속모형 실험을 수행하였다. 그 결과 기본적인 선박제원 중 선체 유체력 미계수와 상관도가 높은 파라메터를 가려낼 수 있었다. 또한 선미형상의 새로운 파라메터와 조종성능과의 상관도를 추정할 수 있었다. 또한 이를 활용하여 유체력미계수에 대한 새로운 경험식을 제시하였다. 이를 활용하면, 초기 선형 설계 시 선형변화 및 수정에 따른 조종성능 추정에 활용할 수 있을 것으로 판단된다.

명목척도를 갖는 변수의 축약방법에 관한 연구 (Reduction of Nominal Variables Using Factor Analysis Model)

  • 홍순욱;조근태;권철신
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 1998년도 추계학술대회 논문집
    • /
    • pp.122-125
    • /
    • 1998
  • In this article, a reduction method for nominal variables is presented and its use illustrated. Factor analysis model (FAM) generally enables us to reduce variables having interval or ratio scale based on their correlation coefficients. We developed an extensive method that makes FAM applicative to the case of nominal variables which does not give correlation coefficients, but only the degree of association. Cramer's V coefficient is a well-established measure that provides the strength of association for nominal variables with a range of [0,1]. When Cramer's V coefficient can logically substitute for correlation coefficient, FAM would be extensively used for reduction of nominal variables.

  • PDF

입력 영상의 서브블록들 사이의 상관관계에 기반한 고속 프랙탈 부호화 (Fast fractal coding based on correlation coefficients of subblocks in input image)

  • 배수정;임재권
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.669-672
    • /
    • 1998
  • In this paper, w epropose a fast fractal coding method based on correlation coefficients of subblocks in input image. In the proposed method, domain pool is selected based on correlation analysis of input image and the isometry transform for each block is chosen based on the IFS method. To investigate the performance of the proposed method, we compared image quality and encoding time with full search PIFS method and jacquin's PIFS method. Experimental results show that proposed method yields nearly the same performance in PSNR, and its encoding time is reduced for images size of 512*512 compared with full search PIFS method and jacquin's PIFS method.

  • PDF

초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석 (Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.

Development and Validation of Computerized Semiquantitative Food Frequency Questionnaire for Koreans with High-Risk of Hypercholesterolemia

  • Kim, Hyung-Sook;Lee, Kyoungsin;Park, Haymie
    • Journal of Community Nutrition
    • /
    • 제6권1호
    • /
    • pp.35-41
    • /
    • 2004
  • Cardiovascular disease has the highest mortality rate in South Korea. Previous studies have reported that serum cholesterol level relates to intake of dietary fat and cholesterol. Therefore, in this study we developed a semiquantitative food frequency questionnaire (FFQ) for Koreans with a high-risk of hypercholesterolemia and to validate the FFQ. Semiquantitative FFQ, which includes 160 food items, reflects intakes of energy, fat, saturated fatty acid (SFA), monounsaturated fatty acid (MUPA), polyunsaturated fatty acid (PUPA) and cholesterol. We chose food items from the previous study of our research group (Suh 1999) which reported a nutritional status of Korean adults with normocholesterolemia, borderline and hypercholesterolemia. To validate the FFQ, we compared the results of the FFQ with those of a 3-day food record using a paired t-test. In addition, we calculated Pearson's and Spearmen's correlation coefficients. Intakes assessed by the FFQ and a 3-day food record were classified into quartile and the degree of agreement was obtained. Fifty-five participants responded for the validation study by completing both the FFQ and a 3-day food record. Pearson's correlation coefficients between estimated intakes by respective methods for energy, fat, SF A, MUPA, PUPA and cholesterol were 0.32,0.41,0.37,0.41,0.37 and 0.21, respectively. Spearman's correlation coefficients of energy, fat, SF A, MUPA, PUPA, cholesterol were 0.31, 0.44, 0.39, 0.46, 0.46, and 0.37, respectively. Nutrient densities in 1000kcal were compared. Pearson's correlation coefficient of cholesterol density increased and other values were similar with original values. The average degree of agreement was 67% that intakes of energy, fat, SF A, MUPA, PUPA and cholesterol assessed by the FFQ and 3-day food records were classified within the same and the adjacent quartile. On the average, 8% were misclassified into the extreme opposite quartile. The average of weighted kappa was 0.46. In conclusion, the FFQ developed in this study is considered to be a reliable tool to assess nutrient intakes for Koreans with a risk of hypercholesterolemia because the FFQ reflects the intakes of energy, fat, SFA, MUFA, PUPA, and cholesterol.

R407C 및 R410A의 수평원관내 응축열전달 (Condensation heat transfer of R407C and R410A in a horizontal smooth tube)

  • 서정현;김민수
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.633-641
    • /
    • 1999
  • Experiments were carried out to investigate the condensation heat transfer characteristics for R22 and its alternatives, R407C (R32/125/134a, 23/25/52wt%) and R410A (R32/125, 50/50wt%). A concentric tube heat exchanger was made to conduct condensation heat transfer tests. Mass flux and saturation temperature of refrigerants at the test section inlet were varied to get the corresponding heat transfer coefficients. Serial and parallel input of secondary fluid (water) were applied to the test subsections. Compared with existing correlations of condensation heat transfer, experimental heat transfer coefficients obtained in this study were generally higher than the predicted values, and mean absolute deviations from several correlations were shown. Wall subcooling was introduced to get a new correlation for condensation heat transfer coefficients by modifying Shah's equation. The RMS deviation of the measured heat transfer coefficients from the new correlation in this study for R22 is 9.9% and that for R407C and R410A are 10.2% and 14.6%, respectively.

  • PDF

순수냉매의 흐름응축 열전달계수 (Flow Condensation Heat Transfer Coefficients of Pure Refrigerants)

  • 김신종;송길홍;정동수
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.175-183
    • /
    • 2002
  • Flow Condensation heat transfer coefficients (HTCs) of Rl2, R22, R32, Rl23, Rl25, R134a, R142b were measured experimentally on a horizontal plain tube. The experi- mental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water-glycol loop. The test section in a refrigerant loop was made of a copper tube of 8.8 mm inner diameter and 1000 mm length respectively. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. All tests were performed at a filed refrigerant saturation temperature of 4$0^{\circ}C$ with mass fluxes of 100, 200, 300 kg/$m^2$s. The experimental result showed that flow condensation HTCs increase as the quality, mass flux, and latent heat of condensation increase. At the same mass flux, the HTCs of R32 and R142b were higher than those of R22 by 35~45% and 7~14% respectively while HTCs of R134a and Rl23 were similar to those of R22. On the other hand, HTCs of Rl25 and Rl2 were lower than those of R22 by 28 ~30% and 15 ~25% respectively Finally, a new correlation for flow condensation HTCs was developed by modifying Dobson and Chato's correlation with the latent heat of condensation considered. The correlaton showed an average deviation of 13.1% for all pure fluids data indicating an excellent agreement.

수평평활관내 탄화수소계 냉매의 응축전열 특성에 관한 연구 (Condensation heat transfer characteristics of hydrocarbon. refrigerants inside horizontal tubes)

  • 이용언;박승준;정진호;장승환;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.15-20
    • /
    • 2001
  • This study investigated the condensation heat transfer coefficients of R-22, R-290 and R-600a inside horizontal tube. Heat transfer measurements were peformed for smooth tube with outside diameter of 12.7 mm Condensation temperatures and mass velocity were ranged from 308 K to 323 K and $51kg/\textrm{m}^2s$s to $250kg/\textrm{m}^2s$, respectively. The test results showed that the local condensation heat transfer coefficients increased as the mass flux increased, and also the effects of mass velocity on heat transfer coefficients of R-290 and R-600a were less than R-22. Average condensation heat transfer coefficients of natural refrigerants were superior to that of R-22. The present results had a good agreement with Haraguchi's correlation.

  • PDF