• Title/Summary/Keyword: rupture angle

Search Result 50, Processing Time 0.024 seconds

The study of drawing on the heterogeneous materials for the unidirectional alignment of carbon nanofiber in metal matrix nanocomposite (금속기지 나노복합재용 탄소나노섬유 일방향 배열을 위한 이종재 인발 연구)

  • 백영민;이상관;엄문광;김병민
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.301-301
    • /
    • 2003
  • In current study, Nanocomposites are reinforced with carbon nanofiber, carbon nanotube and SiC, etc. Since the nano reinforcements have the excellent mechanical, thermal and electrical properties compared with that of existing composites, it has lately attracted considerable attention in the various areas. Cu have been widely used as signal transmission materials for electrical electronic components owing to its high electrical conductivity. However, it's size have been limited to small ones due to its poor mechanical properties. Until now, strengthening of the copper alloy was obtained either by the solid solution and precipitation hardening by adding alloy elements or the work hardening by deformation process. Adding the alloy elements lead to reduction of electrical conductivity. In this aspect, if carbon nanofiber is used as reinforcement which have outstanding mechanical strength and electric conductivity, it is possible to develope Cu matrix nanocomposite having almost no loss of electric conductivity. It is expected to be innovative in electric conducting material market. The unidirectional alignment of carbon nanofiber is the most challenging task developing the cooer matrix composites of high strength and electric conductivity. In this study, the unidirectional alignment of carbon nanofibers which is used reinforced material are controlled by drawing process and align mechanism as well as optimized drawing process parameter are verified via numerical analysis. The materials used in this study were pure copper and the nanofibers of 150nm in diameter and of 10∼20$\mu\textrm{m}$ in length. The materials have been tested and the tensile strength was 75MPa with the elongation of 44% for the copper. it is assumed that carbon nanofiber behave like porous elasto-plastic materials. Compaction test was conducted to obtain constitutive properties of carbon nanofiber Optimal parameter for drawing process was obtained by analytical and numerical analysis considering the various drawing angles, reduction areas, friction coefficient, etc. The lower drawing angles and lower reduction areas provides the less rupture of co tube is noticed during the drawing process and the better alignment of carbon nanofiber is obtained.

  • PDF

A Study on Rescue Technique and Safe Tow of Damaged Ship (2) - Failure Mechanisms of Collision and Grounding of Double Hull Tanker - (손상된 선박의 구난 기술 및 안전 예항에 관한 연구 (2) - 이중선체 유조선의 충돌 및 좌초에 의한 손상역학거동 -)

  • Lee Sang-Gab;Choi Kyung-Sik;Shon Kyoung-Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.1 no.2
    • /
    • pp.82-95
    • /
    • 1998
  • In this paper, two series of numerical simulations are performed using LS/DYNA3D: The first series of numerical simulations are collision events between a 310,000 DWT double hull VLCC (struck ship) and two 35,000 and 105,000 DWT tankers (striking ships). Collisions are assumed to occur at the middle of the VLCC with the striking ships moving at right angle to the YLCC centerline. The second ones, grounding accidents of two 40,000 DWT Conventional and Advanced Double Hull lanker bottom structures, CONV/PD328 and ADH/PD328 models. The overall objective of this study is to understand the structural failure and energy absorbing mechanisms during collision and grounding events for double hull tanker side and bottom structures, which lead to the initiation of inner shell rupture and cause the kinetic energy dissipation to bring the ship to a stop. These numerical simulations will contribute to the estimation of damage extents of collision and grounding accidents and the future improvements in lanker safety at the design stage.

  • PDF

Failure of Cross-Pin Femoral Fixation after Anterior Cruciate Ligament Reconstruction - A Case Report - (전방십자인대 재건술후 대퇴골 경골핀 고정의 실패 - 증례보고 -)

  • Lee Kee-Byoung;Kwon Duck-Joo;Ji Yong-Nam
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.1
    • /
    • pp.92-95
    • /
    • 2003
  • A 34-year-old man with ACL total rupture due to slip down injury, had received ACL reconstruction using autogenous hamstrings tendon with cross-pin femoral fixation. Postoperative course was as usual. But postoperative 3 months later, he complained posterolateral knee pain, recurrent effusion and mild instability. He was managed repeatitive aspiration and nonsteroid antiinflammatory drugs but was failed to relieve symptoms & signs. In CT scans, perforation of posteromedial femoral cortex of lateral femoral condyle was found. In second look arthroscopy, two pieces of broken femoral cross pin were found in between tibiofemoral Joint which was badly injured cartilage. We considered malposition of pins was the main cause of failure. We propose that femoral tunnel must be made more acute angle and femoral cross-pin guide must be positioned more external rotation 10-20 degree than transepicondylar axis made confirm the cross-pin tunnel position in order to avoid posterior cortex perforation and early failure.

  • PDF

Effect of Different Conditions of Sodium Chloride Treatment on the Characteristics of Kenaf Fiber-Epoxy Composite Board

  • SETYAYUNITA, Tamaryska;WIDYORINI, Ragil;MARSOEM, Sri Nugroho;IRAWATI, Denny
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.2
    • /
    • pp.93-103
    • /
    • 2022
  • Currently, biofibers are used as a reinforcement in polymer composites for structural elements and construction materials instead of the synthetic fibers which cause environmental problems and are expensive. One of the chemicals with a pH close to neutral that can be potentially used as a modified fiber material is sodium chloride (NaCl). Therefore, this study aims to investigate the characteristics of a composite board made from NaCl-treated kenaf fiber. A completely randomized design method was used with consideration of two factors: the content of NaCl in the treatment solution (1 wt%, 3 wt%, and 5 wt%) and the duration of immersion of fibers in the solution (1 h, 2 h, and 3 h). The NaCl treatment was conducted by soaking the fibers in the solution for different durations. The fibers were then rinsed with water until the pH of the water reached 7 and subsequently dried inside an oven at 80℃ for 6 h. Kenaf fiber and epoxy were mixed manually with the total loading of 20 wt% based on the dry weight of the fiber. Physical and mechanical properties of the fibers were then evaluated based on JIS A 5908 particleboard standards. The results showed that increasing NaCl content in the fiber treatment solution can increase the physical and mechanical properties of the composite board. The properties of fibers treated with 5 wt% NaCl for 3 h were superior with a modulus of elasticity of 2.085 GPa, modulus of rupture of 19.77 MPa, internal bonding of 1.8 MPa, thickness swelling of 3%, and water absorption of 10.9%. The contact angle of untreated kenaf fibers was 104°, which increased to 80° and 73° on treatment with 1 wt% and 5 wt% NaCl for 3 h, respectively.

Influence of loading rate on flexural performance and acoustic emission characteristics of Ultra High Performance Concrete

  • Prabhat Ranjan Prem;Vignesh Kumar Ramamurthy;Vaibhav Vinod Ingle;Darssni Ravichandran;Greeshma Giridhar
    • Structural Engineering and Mechanics
    • /
    • v.89 no.6
    • /
    • pp.617-626
    • /
    • 2024
  • The study investigated the behavior of plain and fibered Ultra-High Performance Concrete (UHPC) beams under varying loading conditions using integrated analysis of the flexure and acoustic emission tests. The loading rate of testing is -0.25 -2 mm/min. It is observed that on increasing loading rate, flexural strength increases, and toughness decreases. The acoustic emission testing revealed that higher loading rates accelerate crack propagation. Fiber effect and matrix cracking are identified as significant contributors to the release of acoustic emission energy, with fiber rupture/failure and matrix cracking showing rate-dependent behavior. Crack classification analysis indicated that the rise angle (RA) value decreased under quasi-static loading. The average frequency (AF) value increased with the loading rate, but this trend reversed under rate-dependent conditions. K-means analysis identified distinct clusters of crack types with unique frequency and duration characteristics at different loading rates. Furthermore, the historic index and signal strength decreased with increasing loading rate after peak capacity, while the severity index increased in the post-peak zone, indicating more severe damage. The sudden rise in the historic index and cumulative signal strength indicates the possibility of several occurrences, such as the emergence of a significant crack, shifts in cracking modes, abrupt failure, or notable fiber debonding/pull-out. Moreover, there is a distinct rise in the number of AE knees corresponding to the increase in loading rate. The crack mapping from acoustic emission testing aligned with observed failure patterns, validating its use in structural health monitoring.

Study on acoustic emission fracture response and constitutive model of layered sandstone

  • Zhanping Song;Xiaojing Xu;Xiaoxu Tian;Tong Wang;Wanxue Song;Yun Cheng
    • Geomechanics and Engineering
    • /
    • v.39 no.2
    • /
    • pp.157-170
    • /
    • 2024
  • In the present study, the acoustic emission characteristics of hard sedimentary sandstone with varying bedding dip angles were examined through uniaxial compression tests using a rock mechanics creep apparatus combined with an acoustic emission system. The deformation and failure behavior of the sandstone was analyzed by correlating acoustic emission parameters with stress over time. A damage constitutive model was developed, incorporating cumulative acoustic emission ringing counts as a key parameter, with time acting as the intermediary. The findings indicate that, despite the differences in bedding dip angles, the stress-strain curves of the samples follow a similar pattern throughout the loading process, passing through four distinct phases: compaction, elastic deformation, yielding, and post-peak failure. The fracture patterns of the sandstone are influenced by the dip angle of the bedding. Acoustic emission parameters, including the ringing count, cumulative ringing count, and energy, align with these four stages of the stress-strain curve. During the compaction and elastic deformation phases, acoustic emissions remain in a quite state, with only brief spikes at points of rapid stress change. In the unstable fracture stage, acoustic emissions become highly active, while they return to a quite state in the post-fracture stage. The RA value of the acoustic emission displays a banded pattern as time progresses, with areas of dense clustering. When the stress curve declines, RA values enter an active period, mainly associated with the generation of shear cracks. Conversely, during periods of smooth stress progression, RA values remain in a quiet state, primarily linked to the formation of tensile cracks. The time-based damage constitutive model for layered sandstone effectively captures the entire process of rock fracture development.

Biceps Rerouting Technique(Modification of Clancy) for Posterolateral Rotatory Instability (대퇴이두건 전환술(Clancy 변형 술식)을 이용한 후외측 회전 불안정성의 재건)

  • Kim Sung-Jae;Shin Sang-Jin;Kim Jin-Yong;Rhee Dong-Joo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.25-31
    • /
    • 2000
  • Introduction : This study compared the clinical results with biceps rerouting fer the isolated posterolateral instability (PLI) and for the PLI combined with PCL injuries. Methods : 21 cases of isolated PLI (group I) and 25 cases of PLI combined with PCL rupture were included in the study. The PLI was reconstructed by modified biceps femoris rerouting technique with PCL reconstructions performed prior to the PLI correction in cases of combined injury The clinical results were reviewed and analyzed. Results : Pre-operatively positive reverse pivot shift test turned negative in 43 cases post-operatively. Increased preoperative external rotation thigh foot angle (ERTFA) showed significant differences between the two groups and all fell within normal limits post-operatively At a mean follow-up of 40.3 months, the average Lysholm knee score and. The Hospital for Special Surgery Knee Ligament Score for group I and group II revealed above 90 points without statistically significant difference between the groups. 3 cases of tenodesis failure developed and re-operation was performed. Discussion and Conclusion : The advantages of modified Clancy technique include reduced surgical damages to the iliotibial band and fixation of the biceps tendon at the isometric position. The modified biceps rerouting technique is recommended for the reconstruction of both isolated and combined PLI except in patients with severe damages at the attachment of biceps tendon.

  • PDF

The study on the manufacturing intermediary materials for the carbon nanofiber reinforced Cu matrix noncomposite (일방향 탄소나노섬유 강화 Cu 기지 나노복합재료용 중간재 제조에 관한 연구)

  • 백영민;이상관;엄문광
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.46-49
    • /
    • 2003
  • Cu have been widely used as signal transmission materials for electrical electronic components owing to its high electrical conductivity. However, it's size have been limited to small ones due to its poor mechanical properties, Until now, strengthening of the copper at toy was obtained either by the solid solution and precipitation hardening by adding alloy elements or the work hardening by deformation process. Adding the at toy elements lead to reduction of electrical conductivity. In this aspect, if carbon nanofiber is used as reinforcement which have outstanding mechanical strength and electric conductivity, it is possible to develope Cu matrix nanocomposite having almost no loss of electric conductivity. It is expected to be innovative in electric conduct ing material market. The unidirectional alignment of carbon nanofiber is the most challenging task developing the copper matrix composites of high strength and electric conductivity In this study, the unidirectional alignment of carbon nanofibers which is used reinforced material are controlled by drawing process in order to manufacture the intermediary materials for the carbon nanofiber reinforced Cu matrix nanocomposite and align mechanism as well as optimized drawing process parameters are verified via experiments and numerical analysis. The materials used in this study were pure copper and the nanofibers of 150nm in diameter and of $10~20\mu\textrm{m}$ In length. The materials have been tested and the tensile strength was 75MPa with the elongation of 44% for the copper it is assumed that carbon nanofiber behave like porous elasto-plastic materials. Compaction test was conducted to obtain constitutive properties of carbon nanofiber. Optimal parameter for drawing process was obtained by experiments and numerical analysis considering the various drawing angles, reduction areas, friction coefficient, etc Lower reduction areas provides the less rupture of cu tube is not iced during the drawing process. Optimal die angle was between 5 degree and 12 degree. Relative density of carbon nanofiber embedded in the copper tube is higher as drawing diameter decrease and compressive residual stress is occurred in the copper tube. Carbon nanofibers are moved to the reverse drawing direct ion via shear force caused by deformation of the copper tube and alined to the drawing direction.

  • PDF

Structural Performance of Joints for Partial Reinforced Beam Using GFRP Laminated Plate and Cylindrical Reinforced LVL Column (GFRP적층판을 활용한 보강보부재와 원통형 단판적층기둥재 접합부의 내력 성능평가)

  • Song, Yo-Jin;Jung, Hong-Ju;Lee, Jung-Jae;Suh, Jin-Suk;Park, Sang-Bum;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.282-289
    • /
    • 2014
  • After being laminated with a combination of glass fiber reinforced plastic and plywood, the GFRP laminated plate was densificated for 1 hour at $150^{\circ}C$ with pressure of $1.96N/mm^2$. A partial reinforced beam was produced by attaching the 5 GFRP laminated plates to the joint of glulam and the column. In addition, the column to beam joint was produced by using reinforced laminated wooden pin which was made of GFRP sheet and plywood, fiber glass reinforced cylindrical-LVL column. The joint was made of round log, glulam and drift pin as the reference specimen, and its moment resistance was evaluated. As a result, the strength performance of specimens with partial reinforced beams were 1.8 times stronger than the reference specimen on average. Furthermore, rupture was neither occurred on partial reinforced beam nor column. Toughness and stiffness of joints were also fine. The GFRP sheet reinforced laminated plate showed better reinforcement effect than GFRP textile reinforced one. GFRP sheet was inserted into each layer of laminate, and it showed good condition in rotation-angle and strength, therefore it is the most appropriate to reinforce the part of the beam.

The Diagnostic Usefulness of Stress Radiography in Chronic Lateral Ankle Instability (만성 발목 관절 외측 불안정성의 진단에서 스트레스 방사선검사의 유용성)

  • Kim, Yong-Min;Cho, Byung-Ki;Kim, Dong-Soo;Choi, Eui-Sung;Shon, Hyun-Chul;Park, Kyoung-Jin;Kim, Dong-Hwan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.35-40
    • /
    • 2011
  • Purpose: This study was performed to evaluate the diagnostic usefulness of ankle stress radiograph for evaluation of chronic lateral ankle instability. Materials and Methods: Among patients undergoing the modified-Brostrom procedure, 42 cases with complete rupture of the anterior talofibular ligament were enrolled in this study. Sixty Korean adults (120 cases) were recruited as the control group. Radiologic measurement of talar tilt and anterior talar translation was performed through stress radiographs using Telos device. We obtained the normal range of Korean adults, and used as a standard value for judgment of mechanical instability. We analyzed the sensitivity, specificity, positive and negative prediction value of ankle stress radiograph. Results: On ankle stress radiograph, normal range of talar tilt angle and anterior talar translation was below $8.3^{\circ}$, below 7.6mm. Talar tilt angle on varus stress radiograph showed 57% of sensitivity, 97% of specificity, 89% of positive and 86% of negative prediction value. Anterior talar translation on anterior drawer stress radiograph showed 69% of sensitivity, 97% of specificity, 91% of positive and 90% of negative prediction value. Conclusion: Ankle stress radiograph had a good specificity, positive and negative prediction value for the evaluation of mechanical instability. However it underestimated the mechanical instability of ankle joint. It must be remembered that normal stress radiograph does not exclude ankle instability.

  • PDF