• Title/Summary/Keyword: rubber surface

Search Result 700, Processing Time 0.026 seconds

Partial Discharge Characteristics in LLDPE-Natural Rubber Blends: Correlating Electrical Quantities with Surface Degradation

  • Aulia, Aulia;Ahmad, Mohd Hafizi;Abdul-Malek, Zulkurnain;Arief, Yanuar Z.;Lau, KwanYiew;Novizon, Novizon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.699-706
    • /
    • 2016
  • Partial discharges (PD) lead to the degradation of high voltage cables and accessories. PD activities occur due to the existence of impurities, voids, contaminants, defects and protrusions during the manufacture and installation of power cables. Commonly, insulation failures occur at cable joints and terminations, caused by inhomogeneous electric field distributions. In this work, a blend of natural rubber (NR) and linear low density polyethylene (LLDPE) was investigated, and the optimal formulation of the blend that could resist PD was discussed. The experiments were conducted under a constant high voltage stress test of 6.5 kV AC and the magnitude of partial discharge activities was recorded using the CIGRE method II. Pattern analysis of PD signals was performed along with the interpretation of morphological changes. The results showed that the addition of 10 wt% of NR and 5 wt% of Alumina Trihydrate (ATH) provided promising results in resisting PD activities. However, as the NR content increased, more micropores existed, thus resulting in increased PD activities within the samples.

Analysis of Surface Tracking of Micro and Nano Size Alumina Filled Silicone Rubber for High Voltage AC Transmission

  • Loganathan, N.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.345-353
    • /
    • 2013
  • This paper discusses the experimental results in an effort to understand the tracking and erosion resistance of the micro and nano size $Al_2O_3$ filled silicone rubber (SIR) material which has been studied under the AC voltages, with ammonium chloride as a contaminant, as per IEC 60587 test procedures. The characteristic changes in the tracking resistance of the micro and nano size filled specimens were analyzed through leakage current measurement and the eroded masses were used to evaluate the relative erosion and tracking resistance of the composites. The fundamental, third and fifth harmonic of the leakage current during the tracking study were analyzed using moving average current technique. It was observed that the harmonic components of leakage current show good correlation with the tracking and erosion resistance of the material. The thermogravimetry-derivative thermo gravimetric (TG-DTG) studies were performed to understand the thermal degradation of the composites. The physical and chemical studies were carried out by using scanning electron microscope (SEM), Energy Dispersive X-ray analysis (EDAX) and Fourier Transform Infra-red (FTIR) Spectroscopy. The obtained result indicated that the performance of nano filled SIR was better than the micro filled SIR material when the % wt. of filler increased.

Electrostatic Electrification Properties of Silicone Rubber due to Al Ratios (Al 비율에 실리콘 고무의 정전기 대전 특성)

  • Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.8
    • /
    • pp.522-527
    • /
    • 2014
  • In this study, using the silicone rubber sample of $4cm{\times}4cm{\times}0.1cm$ for low voltage cable, the electrostatic electrification properties of three samples that the conductive Al of 0%, 25%, and 50% is attached to the surface of sample was measured. The following conclusion was obtained through this experiment. 1) In case of the sample which has the Al area of 50%, the higher the humidity to 90% in the temperature of $10^{\circ}C$, the electrostatic electrification voltage was reduced about 0.25 kV to 0.02 kV, and it confirmed that the electrostatic electrification voltage was in constant about 0.02 kV in the temperature over $20^{\circ}C$. 2) Increasing the Al area of samples of 0%, 25%, and 50% in temperature of $10^{\circ}C$, it confirmed that the electrostatic electrification voltage was reduced by about 2.67 kV, 2.02 k, 0.21 kV. 3) This study shows that the conductor, followed by temperature and humidity affects the electrostatic electrification voltage.

Application of waste tire rubber aggregate in porous concrete

  • Shariati, Mahdi;Heyrati, Arian;Zandi, Yousef;Laka, Hossein;Toghroli, Ali;Kianmehr, Peiman;Safa, Maryam;Salih, Musab N.A.;Poi-Ngian, Shek
    • Smart Structures and Systems
    • /
    • v.24 no.4
    • /
    • pp.553-566
    • /
    • 2019
  • This study aimed to categorize pervious rubberized concrete into fresh and hardened concrete analyzing its durability, permeability and strength. During the globalization of modern life, growing population and industry rate have signified a sustainable approach to all aspects of modern life. In recent years, pervious concrete (porous concrete) has significantly substituted for pavements due to its mechanical and environmental properties. On the other hand, scrap rubber tire has been also contributed with several disposal challenges. Considering the huge amount of annually tire wastes tossing out, the conditions become worse. Pervious concrete (PC) gap has graded surface assisted with storm water management, recharging groundwater sources and alleviate water run-offs. The results have shown that the use of waste tires as aggregate built into pervious concrete has tremendously reduced the scrap tire wastes enhancing environmental compliance.

A Study on the Heat Transfer Characteristics Around a Surface-Mounted Air-Cooled Module for the Flow Angle-of-Attack (흐름 영각에 따른 강제공랭 모듈 주위의 열전달 특성에 관한 연구)

  • Park, Sang-Hui;Sin, Dae-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1267-1275
    • /
    • 2002
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around a module cooled by forced air flow. The flow angle of attack to the module were 0$^{\circ}$and 45$^{\circ}$. In the first method, inlet air flow(1~7m/s) and input power.(3, 5, 7W) were varied after a heated module was placed on an adiabatic floor(320$\times$550$\times$1㎣). An adiabatic wall temperature was determinated to use liquid crystal film. In the second method to determinate heat transfer coefficient, inlet air flow(1~7m/s) and the heat flux of rubber heater(0.031~0.062W/$m^2$) were varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. Additional information is visualized by an oil-film method of the surface flow on the floor and the module. Plots of $T_{ad}$ and $h_{ad}$ show marked effects of flow development from the module and dispersion of thermal wake near the module. Certain key features of the data set obtained by this investigation may serve as a benchmark for thermal-design codes based on CFD.

Investigation of tracking resistance of engineering plastic and engineering plastic coated silicon rubber (엔지니어링 플라스틱과 실리콘 고무가 코팅된 엔지니어링 플라스틱의 내트래킹성 검토)

  • Heo, Jun;Jung, Eui-Hwan;Lim, Jong-Nam;Lim, Kee-Joe;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1449_1450
    • /
    • 2009
  • Surface contamination and leakage current have caused operating problems. A flashover in a substation may result in destruction of an insulator or many others electrical equipment. Engineering plastics have good characteristic (light weight, good productivity and little of void) as compare with epoxy or porcelain insulators. Outdoor insulator must have resistance to contamination. However, they are not suited to outdoor insulator by reason of being not good hydrophobic. RTV has a good property of hydrophobic and ATH has characteristic obstructing exothermic reaction. In order to reduce the incidence of insulator flashover and damage, the silicon rubber contained nano size ATH coat on surface of engineering plastics. In this paper, it compares resistance tracking of the engineering plastic coated RTV with that of non-coated engineering plastic and ATH filled composites performed much better than non-filled composites.

  • PDF

S-Transform Based Time-Frequency Analysis of Leakage Current Signals of Transmission Line Insulators under Polluted Conditions

  • Natarajan, A.;Narayanan, Suthanthiravanitha
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.616-624
    • /
    • 2015
  • Flashover of power transmission line insulators due to contamination is a major threat to the reliable operation of power system. This paper deals with the analysis of leakage current characteristics of polymeric insulator using S-Transform technique in order to develop a better diagnostic tool to identify the surface condition of outdoor polymeric insulators. In this work, experiments were carried out on 11 kV silicone rubber insulator under AC voltage at different pollution levels. Moving average technique was adopted to find the trend followed by LC peak at different relative humidity conditions. S-Transform was used to find the relationship between energy and frequency content of the leakage current signal with respect to increase in pollution level over a period of time. From the S-Transform time-frequency contour analysis, point of transition to severe arcing due to increase in pollution and its thershold limit were evaluated. Reported results show that the surface condition of insulators could be easily identified from the S-Transform time-frequency analysis of leakage current signals.

Experimental Investigation of Friction and Wear Characteristics of O-Ring (O-ring의 마찰, 마모 특성에 관한 실험적 고찰)

  • Oh, Jun-Chul;Kim, Dae-Eun;Kim, Hyun-Jun;Kim, Mun-Hwan;Kim, Chun-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1125-1131
    • /
    • 2009
  • O-rings are commonly used in machines as a seal. Due to prolonged use the surface of an O-ring can degrade which can lead to leakage as well as contamination. Damage of O-rings used in vacuum applications such as sputter is caused by various mechanisms. Particles detached from the O-ring may cause significant problems on the performance of the system in the vacuum chamber. Therefore, understanding the tribological behavior of O-rings is important to tackle the damage caused by repeated contact. In this work, FKM rubber was used for friction and wear tests conducted to investigate the tribological behavior of O-rings. A reciprocating type of a tribo-tester was used for the tests. The friction coefficient between the steel ball and the FKM specimen was quite high. Also, in order to identify the wear behavior, the surface of the FKM specimen was characterized using both optical and scanning electron microscopes. Evidence of wear due to adhesion and extrusion could be found. The results of this work will aid in improving the durability of O-rings.

The erosion factor of silicone rubber for outdoor use (옥외용 실리콘 고무의 침식요인에 관한 연구)

  • 서광석;김정호;이호열;박용관;양계준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.117-120
    • /
    • 1998
  • It is analyzed the erosing process of the polymeric insulator for outdoor use with the inclined plane method. Materials used are the different type of silicone rubber, they have the content of filler and component each other. As the content of filler added to improve the tracking and erosion resistance. It has the difference of electrical performance and erosion rate. The dry-band arc is also the parameter of accelerating erosion, and appear in the form of leakage current, and the activities of leakage current has a close relationship with the surface hydrophobicity. In this paper, the erosion growth is observed by measuring the time from the voltage application to the whole breakdown, and the erosion depth. In addition, it is measured the hydrophobicity and leakage current to be a cause of erosion by the erosion steps, studied SEM, EDX for observing the transformation of surface structure by erosing.

  • PDF

EPDM Compounds for Electric Insulator (전기 절연용 EPDM Compounds)

  • Kim, In-H.;Hwang, S.H.;Kim, Jin-K.
    • Elastomers and Composites
    • /
    • v.34 no.5
    • /
    • pp.407-413
    • /
    • 1999
  • Non-ceramic composite insulator has been interested in the power industry because of its good characteristics in mechanical properties, mass product and design availability. Also it is lighter, and less unexplosive, compared to a ceramic insulator. Especially EPDM rubber composite insulator can be used for long-term in contaminated environments because of its hydrophobicity. This paper showed the rheological properties, the electrical properties, and contact angles to check the hydrophobicity and the recoverability of the EPDM compounds. Also, we investigated surface morphology of the compound by SEM.

  • PDF