• 제목/요약/키워드: roughing filter

검색결과 7건 처리시간 0.016초

접촉여과방식 거친여과지에서 혼화조건과 여과속도가 고탁도 제거에 미치는 영향 (Effects of Mixing Condition and Filtration Velocity on Turbidity Removal in a Contact Roughing Filter)

  • 박노백;박상민;홍진아;전항배
    • 상하수도학회지
    • /
    • 제21권3호
    • /
    • pp.359-366
    • /
    • 2007
  • Slow sand filtrations have been widely used for water treatment in small communities, however their capacity is often limited by high turbidity in the raw water. For this reason, several pre-treatment facilities were required for a slow sand filter. Turbidity removal from the highly turbid raw water was investigated in roughing filters as a pre-treatment process. The roughing filters followed by rapid mixing tank were operated in the form of a contact filtration. In several jar tests, the predetermined optimum aluminium sulfate (alum) doses for turbid water of 30 and 120NTU were 30 and 50mg/L, respectively. At the optimum alum dose, physically optimum parameters including G value of $220sec^{-1}$ and rapid mixing time of 3 minutes were applied to the contact filtration system. Without addition of alum, the filtrate turbidity from the roughing filters, packed respectively with different media such as sand, porous diatomite ball and gravel, was in the range of 5~30NTU at filtration velocities of 30 and 50m/day. However, the application of a contact filtration to roughing filters showed stably lower filtrate turbidity below 1.0NTU at filtration velocity of 30 m/day. Although the filtration velocity increased to 50m/day, filtrate turbidity was still below 1.0NTU in both single and double layer roughing filters. At influent turbidity of 120NTU, the filtrate turbidity was over 5 NTU in the triple layer roughing filter, which shortened the filter run time. The flocs larger than $10{\mu}m$, formed in the rapid mixing tank, were almost captured through the roughing filter bed, while the almost flocs smaller than $10{\mu}m$ remained in filtrate.

Direct Horizontal-Flow Roughing Filtration의 조립 여상에서의 입자 제거 모델링 (Modeling of Particle Removal in the Coarse Media of Direct Horizontal-Flow Roughing Filtration)

  • 안효원;박노석;이선주;이경혁;왕창근
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.338-347
    • /
    • 2005
  • Horizontal-Flow Roughing Filtration (HRF) is one of altemative pretreatment methods e.g. prior to Slow Sand Filtration (SSF). However, some of its limitations are that the effluent quality drops drastically at higher turbidity (>200 NTU) and at higher filtration rate (>1 m/h). To overcome these drawbacks, we suggested Direct Horizontal-Flow Roughing Filtration (DHRF), which is a modified system of Horizontal-Flow Roughing (HRF) by addition of low dose of coagulant prior to filtration. In this study to optimize the DHRF configuration, a conceptual and mathematical model for the coarse compartment has been developed in analogy with multi-plate settlers. Data from simple column settling test can be used in the model to predict the filter performance. Furthermore, the model developed herein has been validated by successive experiments carried out. The conventional column settling test has been found to be an handy and useful to predict the performance of DHRF for different raw water characteristics (e.g. coagulated or uncoagulated water, different presence of organic matter, etc.) and different inital process conditions (e.g. coagulant dose, mixing time and intensity, etc.). An optimum filter design for the coarse compartment (grain size 20mm) has been found to be of 3 m/h filtration rate with filter length of 4-4.5 m.

해수담수화 막 증류 공정에서 유입수 전처리 적용에 따른 막 오염 평가 (Prevention of membrane fouling by roughing filter for the stand-alone MD process)

  • 윤택근;정성필;김혜원;홍승관;이석헌
    • 상하수도학회지
    • /
    • 제32권4호
    • /
    • pp.301-307
    • /
    • 2018
  • Membrane distillation (MD) is a thermally driven desalination process with a hydrophobic membrane. MD process has been known to have a lower fouling potential compared to other pressure-based membrane desalination process (NF, RO). However, membrane fouling also occurs in MD process. In this study, the membrane fouling was observed in MD process according to the pre-treatment processes. The filtration and precipitation processes were applied as the pre-treatment to prevent the membrane fouling. The pore sizes of roughing filters were 0.4, 5, 10, 30, and $60{\mu}m$. The concentration of the coagulant was 1.2 mg/L as $FeCl_3$. The membrane fouling on MD membrane was successfully removed with both pre-treatment processes.

지하저수지(ASR) 유입수 전처리기법 개발: 물리적 폐색 저하 및 수량공급원활을 위한 2 단계 급속여과지 (Development of pre-treatment for the injection water into the aquifer storage and recovery(ASR) in Korea: The two-step rapid filter to reduce physical clogging and secure the volume of the injected water)

  • 박병주;도시현;홍성호
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.337-345
    • /
    • 2015
  • Two step rapid filter system as a pre-treatment for the injected water into aquifer storage and recovery (ASR) in Korea was developed to reduce physical blockage and secure the volume of the injected water. First, single rapid sand filters with three different media sizes (0.4~0.7, 0.7~1.0 and 1.0~1.4 mm) were tested. Only two sizes (0.4~0.7 and 0.7~1.0 mm) satisfied target turbidity, below 1.0 NTU. However, they showed the fast head loss. To prevent the fast head loss and secure the volume of the injected water, a rapid anthracite filter with roughing media size (2.0~3.4 mm) were installed before a single rapid sand filter. As results, both the target turbidity and reduction of head loss were achieved. It was determined that the media size for a rapid sand filter in two step rapid filter system (i.e. a rapid anthracite filter before a rapid sand filter) was 0.7~1.0 mm. In addition, the effects of coagulant doses on the removal of natural organic matter (NOM), which might cause a biological clogging, were preliminarily evaluated, and the values of $UV_{254}$, dissolved organic carbon (DOC) and SUVA were interpreted.

CCD 폭 측정 시스템 및 퍼지 PID를 이용한 CFWC 제어기 설계 (CFWC Scheme for Width Control using CCD Measurement System and Fuzzy PID Controller in Hot Strip Mills)

  • 박철재
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.991-997
    • /
    • 2013
  • In this paper, we propose a CFWC (CCD and fuzzy PID based width control) scheme to obtain the desired delivery width margin of a vertical rolling mill in hot strip process. A WMS(width measurement system) is composed of two line scan cameras, an edge detection algorithm, a glitch filter, and so on. A dynamic model of the mill is derived from a gauge meter equation in order to design the fuzzy PID controller. The controller is a self-learning structure to select the PID gains from the error and error rate of the width margin. The effectiveness of the proposed CFWC is verified from simulation results under a width disturbance of the entry in the mill. Using a field test, we show that the performance of the width control is improved by the proposed control scheme.

막증류 공정의 전처리 공정으로서 천연 제올라이트 컬럼 적용 (Scalants removal from synthetic RO brine using natural zeolite)

  • 정성필;정하윤;윤택근;이석헌
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.279-284
    • /
    • 2016
  • Membrane distillation (MD) is the thermally driven water separation process based on the vapor pressure difference across the membrane. In order to increase the water recovery of the conventional RO process, the additional MD-PRO pocess was suggested. In this study, the syntheric RO brine was used as a feed solution of the MD process. Due to the high salinity of the RO brine, the MD membrane could be fouled by the scalants. In order to mitigate the scaling on the MD membrane surface, the pre-treatment process using the column filled by natural zeolite was applied. The roughing filter was installed between the pre-treatment process and MD system in order to prevent possible particulate fouling by the debries of the natural zeolite. Moreover, in order to enhance the CEC of the natural zeolite, the NaCl soaking was conducted. The flux and electronic conductivity were monitored under given experimental conditions. And the membrane morphology and the chemical compositions were analyzed by using the SEM-EDX.

수질향상을 위한 정수장 성능평가 (Performance Evaluation for Water Quality Enhancement)

  • Simpson Stephen-L;Singer Charlie
    • 수도
    • /
    • 제24권4호통권85호
    • /
    • pp.30-38
    • /
    • 1997
  • County는 비용과 부지소요는 최소화하면서도 증가하는 지역적 물수요에 부합되는 높은 유량에서 정수장의 성능을 최대화해야하는 필요성에 직면해있다. 개선사항을 찾아내기 위하여 시설물에 대한 상세한 성능평가가 행해졌다. 성능평가는 여과와 소독공정이 운전방식의 조정과 함께 추가시설의 건설에 의하여 개선될 수 있음을 나타내었다. Pilot test는 실험된 여러 가지 대안들 중에서 혼화, 응집, 이중 여과방식이 입자의 제거와 정수 수질에 가장 좋은 것임을 보여주었다. 소독에 대한 분석 결과는 소독방법을 교정하고 추가적인 염소접촉시간을 주는 것이 소독의 안전성을 확보함과 동시에 정수의 소독부산물 농도를 최소한으로 하고 강화되는 규제치와 부합할 수 있는 최선의 방법이 될 것이라는 것을 보이고 있다. Pilot test는 저수두 자동역세척여과지가 1차여과지(roughing filter)로서 효과적이라는 것을 보여주었다. 실험결과는 이중여과가 최종유출수의 탁도를 평균 0.1NTU이하로 감소시키며 입자의 제거율을 3 log로 증가시킴을 나타내고 있다. 정수공정 전반에서의 입자의 제거는 여러 개의 공정의 개별적 성과의 합이 아니므로 시설물들을 건설하기 전에 정수장 전체적으로 예상되는 개선정도를 수량화하기 위하여 Pilot 실험이 필요하였다. Pilot test중에 탁도보다는 입자측정이 유량, 응집제의 주입량, 및 여타 운전조건의 변화에 훨씬 민감함을 보여주었다. 이러한 점이 입자측정이 특히 저탁도 원수에서 처리공정의 성능을 나타내 주는 적절한 추가적 수질인자라는 결론을 보강하여 주었다. 물수요에 부합하기 위하여 Freedom District 정수장을 성공적으로 개선하는 데는 원수의 수질, 단위공정의 성능, 활용가능한 수리학적 수두, 현시설의 배치, 운전양태 등과 같은 기술적 사항에 대한 고려가 필요하였다. 비록 모든 사항들이 각각 일정정도의 영향을 가지고 있으나, 상기의 모든 것들이 수질에 영향을 미쳤으며 수질의 성공적인 개선은 정수장 운전의 모든 부분을 파악할 수 있는 상세한 성능평가를 통하여 가장 잘 달성될 수 있다.

  • PDF