• 제목/요약/키워드: rotary type

검색결과 477건 처리시간 0.026초

複合組織鋼의 第2相 硬度變化가 腐蝕疲勞 크랙傳播에 미치는 影響 (The Influence on the Corrosion Fatigue Crack Propagation in Changing of the Second Phase Hardness of Dual Phase Steel)

  • 오세욱;김웅집
    • Journal of Welding and Joining
    • /
    • 제11권2호
    • /
    • pp.42-52
    • /
    • 1993
  • The corrosion fatigue fracture behaviour of dual phase steel was investigated in 3% NaCl solution at 302MPa and 137MPa. Fatigue test was conducted by cantilever type of self-made rotary bending fatigue testing machine. The fatigue strength increased with increasing the hardness of 2nd phase. Corrosion pit originated at the boundary of the 2nd phase. The size and number of corrosion pits were influenced by the 2nd phase hardness, and pits remained constant in size just after they were transited into cracks. The life of crack initiation was effected by stress level. The shape of relation of .DELTA. K and da/dN has smaller scattering in it in 3% NaCl solution than that in air. The higher the 2nd phase hardness is, the greater the corrosion fatigue life becomes. Corrosion fatigue fracture behaviour was primarily effected by mechanical factor in case of high stress(302MPa), but by electro-chemical reaction in a lower stress(137MPa). As stress level got lower and hardness of the 2nd phase got higher, the roughness of fracture surface increased.

  • PDF

단순화된 구조의 회전형 초음파모터의 제작 및 실험 (Fabrication and Experiment of Rotary Ultrasonic Motor with Simple Structure)

  • 김종욱;정현호;정성수;박충효;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.319-319
    • /
    • 2010
  • The previous cross type USM(ultrasonic motor) has the stator of cross shape composed of 8 ceramics. However, ultrasonic motor with simple structure has the stator composed of only 4 ceramics. Principle of the motor is to apply alternative voltages which have 90 phase difference to attached ceramics, and then elliptical displacement is generated at four edges of elastic body. Characteristics of the motor were simulated by FEM(finite element method). The parameters were size of the stator and thickness of the ceramics. According to FEM results, driving frequency of motor is defined at 28 [kHz]. On the contrary, driving frequency of fabricated motor is defined at 26.8 [kHz] and then, experimental results were compared with FEM results at the frequency. As a result, elliptical displacement and speed of USM increased linearly with increasing applied voltage.

  • PDF

수정유리와 SF-5 유리의 ELID 연삭특성 비교 (Comparative Study on the Grinded Surface Characteristics of Quartz Glass and SF-5 Glass using ELID(Electrolytic In-Process Dressing) Grinding)

  • 박상후;양동열;곽태수;오오모리히토시
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.94-97
    • /
    • 2003
  • A precise fabrication technology of glass is increasingly demanded fer the latest Industrial applications of spherical lenses. micro-optical components, laser applications and so on. Most of cases, the surface roughness of glass is required to be minute for improving the optical characteristics. Then. the machining characteristics of SF-5 glass and quarts glass were studied by using the ELID grinding process to get mirror surface and productivity compared with a general lapping process. A rotary type grinder with ELID generator was used to make the mirror surface of glass and a Mitutoyo surface tester and a nano-hardness tester were also used to measure the grinded surface or glass. As the results of experiments. they showed that the surface roughness(Ra) of SF-5 glass was under 7.8 nm and that of quartz glass was under 3.0 nm using the # 8000 grinder. So, the possibility of highly efficient and accurate surface for optical components can be achieved by the ELID grinding process.

  • PDF

오스템퍼링처리한 구상흑연주철의 피로한도에 미치는 인공결함의 영향 (Influence of Artificial Defect on Fatigue Limit in Austempered Ductile Iron)

  • 김민건;김진학
    • 대한기계학회논문집A
    • /
    • 제23권11호
    • /
    • pp.1922-1928
    • /
    • 1999
  • Rotary bending fatigue tests were carried out to investigate the influence of artificial defects on fatigue limit in annealed and austempered ductile iron. Obtained main results are as follows : (1) Artificial defect(micro hole type, dia.<0.4 mm) on specimen surface did not bring about a obvious reduction of fatigue limit in austempered ductile iron(ADI) as compared with annealed ductile iron. (2) According to the investigation of $\sqrt{area}_c$ which is the critical defect size to crack initiation at artificial defect, $\sqrt{area}_c$ of ADI is larger than that of annealed ductile iron. This shows that the situation of crack initiation at artificial defect in ADI is more difficult in comparison with annealed ductile iron. (3) One of the reasons for the low rate of crack initiation from artificial defect in ADI is that the resistance of matrix to crack initiation is higher than that of annealed ductile iron. (4) In case that the $\sqrt{area}$ of artificial defect and graphite nodule is the same, the rate of crack initiation from graphite nodule is higher than that from artificial defect. This reason is that the serious ruggedness around graphite nodule is formed by austempering treatment.

필드로봇을 위한 힘방향 조이스틱 개발 (Development of Force Reflecting Joystick for Feild Robot)

  • 송인성;안경관;양순용;이병룡
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.357-360
    • /
    • 1997
  • Abstract: In teleoperation field robotic system such as hydraulically actuated robotic excavator, the maneuverability and convenience is the most important part in the operation of robotic excavator. Particularly the force information is important in dealing with digging and leveling operation in the teleoperated excavator. Excavators are also subject to a wide variation of soil-tool interaction forces. This paper presents a new force reflecting joystick in a velocity-force type bilateral teleoperation system. The master system is electrical joystick and the slave system IS hydraulically actuated cylinder with linear position sensor. Particularly Pneumatic motor is used newly in the master joystick for force reflection and the information of the pressure of salve cylinder is measured and utilized as the force feedback signal. Also force-reflection gain greatly affects the excavation performance of a hydraulically actuated robotic system and it is very difficult to determine it appropriately since slave excavator contacts with various environments such as from soft soil to rock. To overcome this, this paper proposes a force-reflection gain selecting algorithm based on artificial neural network and fuzzy logic.

  • PDF

탈수소 열처리 공정에 의한 원심주조 메탈베어링의 제조 시스템 (Manufacturing System of Centrifugal Cast Metal Bearing by Dehydrogenation)

  • 김정훈;김충구;변재영;이은숙;양지웅;최원식
    • 한국기계가공학회지
    • /
    • 제19권5호
    • /
    • pp.111-117
    • /
    • 2020
  • Centrifugal casting is suitable for producing hollow-products using centrifugal force. Bush type metal bearings are the key parts that facilitate the rotational movement of various machinery. Metal bearings produced by conventional centrifugal casting machines show rotational imbalance. Therefore, after injecting a large amount of material, the product's precision is secured in the secondary processing. Rotational imbalance is caused by the force acting on the rotary disc plate. In order to minimize rotational imbalance, NASTRAN was used for the optimal design and structural analysis. It was concluded that the rotating plate of the conventional centrifugal casting machine should be prevented from tilting. For this purpose, the location & thickness of the stiffeners were obtained through the optimum design. In the conventional centrifugal casting machine, both ends of the product are lower in temperature than the center part, so internal stress occurs. This solves this problem by inserting a heating coil into the rotating plate.

가스인젝션 기술을 적용한 공기열원 가변속 열펌프의 냉방성능 향상에 관한 연구 (The Cooling Performance Enhancement of a Variable Speed Heat Pump Using Gas Injection Technique)

  • 정민우;허재혁;정해원;김용찬
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.425-432
    • /
    • 2009
  • In this study, the improvement of cooling capacity by applying gas injection technique in a two-stage heat pump using R410A was experimentally investigated. A twin rotary type compressor with gas injection was applied to the heat pump system. The optimum refrigerant charge for the injection and the non-injection cycles was selected to achieve the maximum COP at the cooling standard condition. The injection cycle showed less optimum refrigerant charge than that of the non-injection cycle. The cooling performances of the injection and the non-injection cycles were measured and compared by varying compressor frequency from 40 to 90 Hz. The cooling capacity of the gas injection cycle was 1.6% -11.3% higher than that of the non-injection cycle. The COP of the gas injection cycle was 13.7% to 28.9% higher than that of the non-injection cycle at the same cooling capacity. The heat pump system showed stable operation after 30% of the injection valve opening.

에너지 절약형 공기압 시스템 특성에 관한 연구 (A Study on the Energy Saving Type Pneumatic System Characteristics)

  • 김형의;김동수;강보식;성백주
    • 연구논문집
    • /
    • 통권25호
    • /
    • pp.91-98
    • /
    • 1995
  • Recently, improving the energy efficiency of a pneumatic system and reducing the consumption of compressed air were a concern of scholars at domestic and abroad. The using fields of a pneumatic system are widely used in factory automation of manufacturing line, chemical factories with explosiveness danger and petroleum industries etc. In particular, pneumatic cylinder is applied to feeding work of workpiece. jig tools and press mechanism, reciprocation and rotary motion with rack and pinion. In this study, the experimental apparatus consisted to pneumatic cylinder, dual supply pressure regulator and solenoid valve. The dual supply pressure regulator connected to outlet port of solenoid valve. The supply pressure($4.5kg_f/cm^2$) of compressed air goes into the rodless chamber 1 to drive the piston rod forward which is named working stage. The supply pressure ($2kg_f/cm^2$) of compressed air goes into the rod chamber 2 to drive the piston rod backward which is named no-working stage. Accordingly, the research results of this study can be obtained to Energy-Saving Effects of the compressed air about 35%.

  • PDF

다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅰ) - 환기측과 외기측의 풍량 변화에 대하여 - (Study on the Performance of Total Heat Exchanger with Rotating Porous Plates)

  • 조동현;임태우
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.11-17
    • /
    • 2005
  • This paper reports an experimental study on the performance evaluation of air-to-air heat exchanger with rotary type newly developed in this study. Air flow rate is varied from 10 to 120 m3/h. The range of RPM of the porous rotating discs mounted inside the heat exchanger unit is 0 to 50. The temperature of the return air side is set by adjusting heat supply at heater. The material of the porous rotating discs is cooper and its thickness is 1.0 mm. The heat transfer rate increased with the increase in air flow rate. It was found that the heat transfer rate, as the temperature of the return air side was increased, was improved due to higher temperature difference. The heat exchange performance increased with the increase in the temperature of the return air side at the conditions of the same RPM. The sensible heat exchange efficiency was maximum 68 to 76 percent, and enthalpy exchange efficiency 64 to 74 percent.

  • PDF

레이저를 이용한 캠 프로파일 정밀 측정 장치 개발에 관한 연구 (A Study on the Development of High Precision Cam Profile Measuring System using Laser Interferometer)

  • 임상헌;이춘만;정종윤;윤상대;신상훈;신성우;황영국
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.267-268
    • /
    • 2006
  • Cam mechanisms are one of the most popular devices for generating irregular motion and are widely used in many industrial areas. The purpose of this study is the development of high precision measuring system fur measurement data acquisition and analysis of a manufactured cam profile. The developed system is composed of servo motor, CNC controller, rotary encoder, and laser interferometer And also, this system is non-contact measuring type. The developed system takes only 5 minutes to measure a cam profile and to analyze the measuring data while the CMM(coordinate measuring machine) takes about 1 hours even by a skilled operator.

  • PDF