• Title/Summary/Keyword: rotary type

Search Result 477, Processing Time 0.027 seconds

Design and FEA of Langevin Type Ultrasonic Vibrator for Development of Rotary Motor (회전형 초음파모터 개발을 위한 란쥬반형 진동자의 설계 및 유한요소해석)

  • Park, Min-Ho;Kim, Hyeoung-Woo;Park, Tae-Gone;Kim, Myong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.53-56
    • /
    • 2000
  • Piezoelectric ceramics can provide electro-mechanical transduction with high stresses but low displacement. To obtain larger displacements, several mechanical amplifying structures have been used. High alternating displacements can be obtained using resonant structure. In this paper, we designed a bolt-tightened Langevin type ultrasonic vibrator whose resonant frequency is 50[kHz] and ceramics are multilayered. FEM(Finite Element Methode) was employed to calculate. the resonant frequencies and maximum displacements of designed vibrators. The designed resonant frequency and computer calculated frequencies were coincided. When input voltages were increased, the maximum displacements also rose. As AC voltage was applied, the maximum displacement were shown sinusoidal changes. Terminal input admittance over a frequency range spanning the resonant frequency were calculated. ANSYS was used to find resonant frequencies and calculate displacements of vibrators.

  • PDF

Proportional Flow Control Valve with PZT Actuator (압전식 비례제어밸브)

  • Yun, So-Nam;Kim, Chan-Yong;Ham, Young-Bog;Yoon, Seok-Jin;Lee, Kyung-Woo
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.11 s.282
    • /
    • pp.758-762
    • /
    • 2005
  • Gas valve for domestic use is used for flow control of LPG (Liquefied Petroleum Gas) or LNG (Liquefied Natural Gas) of which pressure is about $200\;mmH_{2}O(\fallingdotseq0.0196\;[bar])$. Currently, two kinds of valves such as rotary type and button type are widely used in many applications. But, these valves have some problems that they are not controllable and reliable. Piezo actuation combined with modem microelectronics provides a reliable, quiet, low energy, infinitely adjustable gas valve. In this paper, gas valve using piezo actuator which are bimorph and a circle type was studied. Also, Prototype for gas valve was manufactured and characteristics of the prototype gas valve were analyzed.

A Study on the Factors Affecting the Performance of Plastic Plate Heat Exchanger (플라스틱 판형 열교환기의 성능에 영향을 미치는 인자에 관한 연구)

  • Yoo Seong-Yeon;Chung Min-Ho;Lee Yong-Moon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.839-848
    • /
    • 2005
  • Plastic plate heat exchangers have many advantages over the conventional heat exchangers such as aluminum plate heat exchangers, rotary wheel heat exchangers and heat pipe heat exchangers which have been used for ventilation heat recovery in the air-conditioning systems. In the present study, pressure drop and heat transfer characteristics of plastic plate heat exchangers are investigated for various design parameters and operating conditions which affect the performance of the plastic plate heat exchangers. In flat plate type heat exchanger, material thickness and channel height of heat exchanger are considered, and corrugate size and heat transfer area are considered in case of corrugate type heat exchanger. Pressure drop and effectiveness of the corrugate type heat exchanger increase as the corrugate size decreases.

A Study on Novel Hybrid Type Encoder Design for the Position Control with the High-resolution (고정도 위치제어용 Hybrid Type Encoder에 관한 연구)

  • Cho S. E.;Lee S. H.;Song S. G.;Park S. J.;Kwon S. J.;Kim C. U.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.87-94
    • /
    • 2005
  • This paper is about the compensation of phase angle error and amplitude difference in stationary 2 pole coordinates by the installation variation of sensor at low cost high resolution digital hybrid encoder. To solve the problem of amplitude difference at the existing hybrid encoder, we normalized the relative magnitude of the two analog signals. and also to solve the problem of installation variation when installed the sensor, we rotate the stationary 2 pole coordinates to compensate the location error of sensor. and we used and tested the QEP function and A/D port in DSP(TMS320F2812) to verify the mentioned proposed method.

A Study on the Design Procedure of the Eight Pole Magnetic Bearings for the Inner-rotor and the Outer-rotor Type

  • Lee, Jun-Ho;Park, Chan-Bae;Lee, Byung-Song;Lee, Su-Gil;Kim, Jae-Hee;Jung, Shin-Myung;Lee, Hyung-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1424-1430
    • /
    • 2013
  • This paper presents design procedure of the magnetic bearings used for high-speed electric machines and flywheel energy storage systems. Magnetic bearing can be categorized by inner-rotor type and outer-rotor type according to the position of the rotary disc. These two types are applicable based on application environments such as application space, required attraction force, and controllability. Magnetic bearing is generally designed based on the ratio (geometrical coefficient or geometrical efficiency) of pole width to rotor journal radius but proper ratio is only decided by the analysis. This is the difficulty of the magnetic bearing design. In this paper, proper design technology of the inner-rotor type and outer-rotor-type eight pole magnetic bearings is introduced and compared with the FEM analysis results, which verifies the proposed design procedure is suitable to be applied to the design of the magnetic bearings for the industrial applications and flywheel energy storage system.

Preference of undergraduate students after first experience on nickel-titanium endodontic instruments

  • Kwak, Sang Won;Cheung, Gary Shun-Pan;Ha, Jung-Hong;Kim, Sung Kyo;Lee, Hyojin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.176-181
    • /
    • 2016
  • Objectives: This study aimed to compare two nickel-titanium systems (rotary vs. reciprocating) for their acceptance by undergraduate students who experienced nickel-titanium (NiTi) instruments for the first time. Materials and Methods: Eighty-one sophomore dental students were first taught on manual root canal preparation with stainless-steel files. After that, they were instructed on the use of ProTaper Universal system (PTU, Dentsply Maillefer), then the WaveOne (WO, Dentsply Maillefer). They practiced with each system on 2 extracted molars, before using those files to shape the buccal or mesial canals of additional first molars. A questionnaire was completed after using each file system, seeking students' perception about 'Ease of use', 'Flexibility', 'Cutting-efficiency', 'Screwing-effect', 'Feeling-safety', and 'Instrumentation-time' of the NiTi files, relative to stainless-steel instrumentation, on a 5-point Likert-type scale. They were also requested to indicate their preference between the two systems. Data was compared between groups using t-test, and with Chi-square test for correlation of each perception value with the preferred choice (p = 0.05). Results: Among the 81 students, 55 indicated their preferred file system as WO and 22 as PTU. All scores were greater than 4 (better) for both systems, compared with stainless-steel files, except for 'Screwing-effect' for PTU. The scores for WO in the categories of 'Flexibility', 'Screwing-effect', and 'Feeling-safety' were significantly higher scores than those of PTU. A significant association between the 'Screwing-effect' and students' preference for WO was observed. Conclusions: Novice operators preferred nickel-titanium instruments to stainless-steel, and majority of them opted for reciprocating file instead of continuous rotating system.

A Study on the Manufacture of Activated Carbon using Indonesian Coal (인도네시아 석탄을 이용한 활성탄 제조에 관한 연구)

  • Baek, Ill-Hyun;Kim, Tae-Young;Yeon, Ik-June;Lee, Jeong-Sik;Lee, Dong-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.419-423
    • /
    • 1998
  • Indonesian coal-based activated carbon was manufactured with steam-reaction method. Also effects of carbonization temperature and steam amount on the process yield and quality of the product were investigated at the activation temperature of $900^{\circ}C$. The rotary kiln type furnace was used for both carbonization and activation and the optimum operation conditions were carbonization temperature of $700^{\circ}C$, steam amount of 2.7g steam/g char and activation temperature of $900^{\circ}C$. At this condition, the iodine value of activated carbon was 1,010 mg/g. Methylene Blue Adsorption Number was 230mg/g and B.E.T. surface area was $1,020m^2/g$ with the hardness about 97.

  • PDF

Characteristics of Flow Pattern and Mass Transfer in a Shaking Vessel with Figure-Eight Circulating Motion (8자 진동교반에 의한 교반조내 유동상태 및 물질전달 특성)

  • Lee, Young Sei;Kato, Yoshihito
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.174-180
    • /
    • 2015
  • The flow pattern and the solid-liquid mass transfer coefficient in figure-eight shaking vessels were observed by experimental method. The flow patterns, mixing time, power consumption and mass transfer coefficient in the figureeight shaking vessels changed irregularly with increase in the shaking frequency. Any frequency, even in the Fr = 0.095 or more became clear experimentally. The region of the optimum operating condition of the figure-eight shaking was larger than that of the reciprocal shaking. The solid-liquid mass transfer coefficient was correlated with the same correlation as that of the rotary shaking vessel of existing. The gas-liquid mass transfer coefficient of the figure-eight shaking vessel was also correlated with the same type of correlation as that of the rotary shaking vessel of existing.

A STUDY ON THE ROOT CANAL MORPHOLOGY CHANGE BY NICKEL-TITANIUM AND STAINLESS STEEL FILE INSTRUMENTATION USING COMPUTERIZED TOMOGRAPHY (Nickel-Titanium file과 Stainless steel file을 이용한 근관형성시 컴퓨터 단층촬영사진상의 근관형태 변화에 관한 연구)

  • So, Mun-Seop;Im, Mi-Kyung;Lee, Keon-Il;Lee, Yong-Keun;Lee, Su-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.659-669
    • /
    • 1997
  • The goals of root canal instrumentation are complete debridement of pulp tissue, removal of microbes and affected dentin, and proper cleaning and shaping of the root canal space before obturation. Instrumentation with stainless steel files has been shown to produce undesirable results in canals, regardless of the improved technique or modified file type used. Nickel-Titanium(Ni-Ti) alloy has been shown to be exceptionally elastic, having a lower bending moment and lower permanent set after torsion, compared with similar gauge stainless steel. The purpose of this study was to evaluate the change of root canal prepared by Ni-Ti rotary and stainless steel instruments. Thirty-four single rooted teeth of similar shape and canal size were divided into three groups. The teeth were scanned by computed tomography before instrumentation. In group 1, canals were instrumented using a step-back technique with K-file. In group 2, canals were prepared with K-flex file using the same technique as group 1. Group 3 was prepared with nickel-titanium(Ni-Ti) rotary instrument using a manufacture's instruction. Instrumented teeth were again scanned using computed tomography, and reformated images of the uninstrumented canals were compared with images of the instrumented canals. K-flex file and Ni-Ti file caused significantly less canal transportation than K-file in the 8mm root canal section from the apex(p<0.05). K-flex file and Ni-Ti file produced more centered canal preparation than K-file in the 2mm section(p<0.05). Ni-Ti file maintained more precisely the center of the canal than K-flex file in the 10mm section (p<0.05). There was no difference in the removed volume of canals among each groups.

  • PDF

Numerical and Experimental Study of U-Bending of SUS304L Heat Transfer Tubes (SUS304L 튜브의 U-Bending 성형공정에 관한 해석적·실험적 연구)

  • Kim, Y.B.;Kang, B.S.;Ku, T.W.
    • Transactions of Materials Processing
    • /
    • v.23 no.7
    • /
    • pp.405-412
    • /
    • 2014
  • As a major type of heat exchanger, the steam generator (SG) produces steam from heat energy of a nuclear power plant reactor. The steam produced by the steam generator flows into a turbine, and plays an important role in electric power generation. The heat transfer tubes in the steam generator consist of approximately 10,000 U-shaped tubes, which perform a structural role and act as thermal boundaries. The heat transfer tubes conduct the thermal energy between the primary coolant (about $320^{\circ}C$, $157kgf/cm^2$) obtained from the reactor and the secondary coolant (about $260^{\circ}C$, $60kgf/cm^2$) as part of the secondary system. Recently, the heat transfer tubes in the steam generator of the pressurized water reactor (PWR) are primarily produced from Alloy 600 and Alloy 690 seamless tubes. As a pilot study to find process parameters for the cold U-bending process using rotary draw bending, numerical and experimental investigations were conducted to produce U-shaped tubes from long straight SUS304L seamless tubes. 3D finite element simulations were run using ABAQUS Explicit with consideration of the elastic recovery. The process parameters studied were the angular speed, the operation period and the bending angle. Experimental verifications were conducted to insure the suitability of the final U-shaped configurations with respect to both ovality and wall thickness.