• Title/Summary/Keyword: root length

Search Result 1,722, Processing Time 0.034 seconds

PLANT ROOT LENGTH DENSITY MEASUTEMENT USING IMAGE PROCESSING

  • Kim, Giyoung;David H.Vaughan
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.792-801
    • /
    • 1996
  • A thinning algorithm -based image analysis technique was developed to measure corn root lengths. The root length measurement method was evaluated by comparing thread lengths measured by the image analysis system with actual thread lengths. The length measurement method accurately estimated actual thread lengths (less than 2% calculated error). Also, a rapid root length density measurement procedure, which utilizes the above root length measurement method, was developed to estimate corn root length density without washing the roots. Root length densities estimated from the cut soil surface of core samples taken from the field were paired with the root length densities determined from washed roots from the same soil core sample. A linear relationship between these two values was expected and was found. Eliminating the root washing procedure reduces the time required for measuring corn root length density substantially.

  • PDF

Assessing the Root Development and Biomass Allocation of Magnolia champaca under Various Mulching at Montane Rainforest Cameron Highlands, Pahang, Malaysia

  • Wahidullah Rahmani;Frahnaz Azizi;Mohamad, Azani Bin Alias
    • Journal of Forest and Environmental Science
    • /
    • v.39 no.2
    • /
    • pp.96-104
    • /
    • 2023
  • The successful restoration program requires a comprehensive understanding of variables influencing seedling efficiency. Below-ground is hypothesized to have a major impact on seedling performance of species when planted in agriculture, and degraded areas with different types of mulching. This study investigated on Sg. Terla Forest Reserve in Cameron Highlands Pahang, Malaysia. In this study randomized complete block design (RCBD) was used. The excavation method was applied to study the root system development, above, and below ground biomass distributions under different types of mulching: coconut mulching (CM), oil palm mulching (OM), plastic mulching (PM) and control (CK). The root diameter, main root length, lateral root length, root coiling, and root direction toward to sun were recorded. The results in this study indicate that mulching had significant effect on root diameter, main root length, and root distributions among treatments while for lateral root length, root: shoot ratio, dry biomass distributions, and above and below ground biomass did not showed significant effect among treatments. The highest values for root diameter, lateral root length, main root length, root distributions, dry biomass distributions and above and below ground biomass were showed in CM treatments. However 75% of root coiling was observed in seedlings between treatments.

The Characteristics and Correlation Coefficients of Characters in Panax ginseng, Violet-stem Variant and Yellow. berry Variant, and Panax quinquefolium. (고려인삼과 미국삼의 형질특성 및 형질간 상관관계)

  • 최광태;안상득;박규진;양덕조
    • Journal of Ginseng Research
    • /
    • v.7 no.2
    • /
    • pp.133-147
    • /
    • 1983
  • This study was carried out to obtain the basic information for the development of new ginseng varieties. The two variants (violet-stem variant and yellow-berry variant) of Korean ginseng (Panax ginseng C.A. Meyer) and American ginseng (Panax quinquefolium L.) of one to four-year were used for this study. All of the characteristics, such as leaf length, leaf width, petiol length, number of leaves per plant, number of leaflets per plants, stem diameter, stem length, number of stems per plant, root length, primary root length, root diameter, root weight were determined and correlations among them were estimated. The results obtained were summarized as follows. 1. Leaf length, petiol length, number of leaves per plant, and number of leaflets per plant of Panax ginseng, violet-stem variant and yellow-berry variant, were larger than those of Panax quinquefolium at all of the plant ages, while leaf width was wider in Panax quinquefolium. 2. The length of stem of Panax quinquefolium was shorter than that of Panax ginseng, and the frequency of multi-stem plants at 4-year-old ginseng was larger in violet-stem variant than in Panax quinquefolium and yellow-berry variant. 3. In the characteristics of ginseng root, the primary root length of Panax ginseng, violet-stem variant and yellow-berry variant, were less than that of Panax quinquefolium, while root weight, root diameter, and umber of secondary root related to yield were larger in Panax ginseng. 4. The root weight per plant related to the yield had positive and highly significant correlations with stem diameter, leaf length, leaf length, leaf width, number of compound leaves and leaflets in Panax ginseng and Panax quinguefolium. 5. The root weight related to the wield of ginseng had been influenced to stem diameter, leaf length, and leaf width directly, and number of compound leaves and leaflets indirectly. 6. The number, total area and activity of stomate per mm2 of Panax quinquefolium were more, larger and stronger than those of Panax ginseng.

  • PDF

A RADIOGRAPHICAL AND CLINICAL STUDY OF ANTERIOR TOOTH MOBILITY (전치부 치아동요에 관한 방사선학적 및 임상적 연구)

  • Lee, Kwang-Ho;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.290-300
    • /
    • 1995
  • Tooth mobility is one of the most important clinical parameters in examination, diagnosis, prognosis and treatment planning procedure. In order to determine the differences of tooth mobility according to radiographical bone level, clinical root length, clinical crown/root ratio, and bleeding on probing, 90 male adults with periodontal disease and 10 male adults with periodontal health($25{\sim}45$ years old) were selected through clinical examinations including occlusal relationship, probing depth, attachment level, and bleeding on probing. On the mandibular anterior teeth, standard periapical radiographs were taken, and tooth mobility was measured by Periotest(Siemens Co., Germany). The radiographic bone level of individual tooth was evaluated as coronal 1/3, middle 1/3, and apical 1/3 to anatomical root length, and clinical crown length from incisal edge to bone level and clinical root length from bone level to root apex were measured with Boley gauge, and subsquently clinical crown/root ratio was calculated. The difference of tooth mobility(Periotest value) according to radiographical bone level, clinical root length, clinical crown/root ratio, and bleeding on probing was statistically analyzed by unpaired Student t-test. Tooth mobility was significantly higher in bleeding group than non-bleeding group on probing in the teeth radiographic bone level of middle 1/3, with clinical root length longer than 6mm, and with clinical crown/root ratio over 0.3(p<0.01). But there was no statistical difference in tooth mobility between bleeding group and non-bleeding group on probing in the teeth with radiographic bone level of apical 1/3, with short clinical root length less than 5mm, and with clinical crown/root ratio under 0.2(p>0.05). The results note that the tooth mobility depends on clinical root length, clinical crown/root ratio and gingival inflammation, and in the teeth with relatively good alveolar bone support gingival inflammation is one of the most important factors that affect tooth mobility.

  • PDF

A STUDY ON THE ACCURACY OF THE ROOT-ZX ACCORDING TO THE VARIOUS CONDITIONS OF ROOT CANALS (근관내 여러 가지 조건에 따른 Root-ZX의 정확도에 관한 연구)

  • Hwang, Ho-Keel;Shin, Young-Guen;Kim, Pyung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.474-482
    • /
    • 2000
  • Currently frequency-dependent type electronic apex locators have been widely used to determine the working length in endodontic treatment. But, accuracy of electronic apex locators is controversial. The purpose of this study was to evaluate the accuracy of Root-ZX(Morita Co., Japan) at different kinds of conditions of root canals compared with the radiographic working length. The 40 extracted human anterior teeth with fully formed apices and without any caries were used. The radiographs were taken for working length with the 0.5mm short of #15 K-file tip just visible at the foramen under the surgical microscope(Carl Zeiss Co. Germany) at 25X. Then the electronic working lengths were determined with Root-ZX at the different kinds of conditions of root canals according to the presence of electrolyte and Crown-down pressureless technique. The results were as follows ; 1. There was no significant statistical difference in working length between radiograph and Root-ZX. 2. There was no significant statistical difference in electronic working length between the canal with electrolyte and without electrolyte. 3. There was no significant statistical difference in electronic working length between the canal without any instrumentation and after Crown-dow pressureless technique. 4. Of the total 40 root canals, 85% in Group I, 92.5% in Group II, 95% in Group III and 95% in Group IV using Root-ZX showed coincidence within 0.5mm accuracy compaing with the radiographic working length. The results showed that the Root-ZX can be use effectively for measuring the working length of root canal after instrumentation with Crown-down pressureless technique regardless of the presence of electrolyte in root canal.

  • PDF

Effects of root trunk length after GTR on clinical outcomes (하악 제1대구치 치근본체의 길이가 조직유도재생술의 임상결과에 미치는 영향)

  • Pi, Sung-Hee;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.427-434
    • /
    • 2006
  • The form of furcation influence both the pathogenesis of periodontal destruction and therapeutic results. The present study was performed to evaluate the effect of root trunk length on clinical outcomes of guided tissue regeneration. Total 30 mandibular first molars were evaluated in this study. Probing pocket depth, clinical attachment level, vertical defect depth and horizontal defect depth were measured at baseline and 6 month after GTR. Correlation coefficients between root trunk length and other clinical measurement were analyzed. The results of this study were as follows 1. The mean root trunk length in lower 1st molar was 2.15 mm. 2. Probing pocket depth, clinical attachment level, vertical defect depth and horizontal defect depth were significantly reduced at 6 month postoperatively compared to values of baseline 3. Correlation coefficient between root trunk length and vertical defect depth at baseline was 0.406 showing the positive correlation 4. Correlation coefficient between root trunk length and horizontal defect depth at baseline was -0.463 showing the negative correlation. 5. Correlation coefficient between root trunk length and decrease of horizontal defect depth after GTR was 0.654 showing the positive correlation. In conclusion, the root trunk length maybe effector for clinical outcome after guided tissue regeneration.

Evaluation of Alfalfa Autotoxicity on Germination and Early Seedling Growth of 3 Cultivars

  • Chon, Sang-Uk;Choi, Seong-Kyu
    • Plant Resources
    • /
    • v.3 no.1
    • /
    • pp.71-78
    • /
    • 2000
  • Autotoxicity restricts reseeding of new alfalfa(Medicago sativa L.) after alfalfa until autotoxic chemical(s) breaks down or is dispersed into external environments, often requiring up to a year or more. One solution for reducing autotoxicity would be to select germplasms or cultivars with tolerance to the autotoxic chemical(5) and use genetically breeding program. Bioassay of seed germination and early seedling growth was conducted to evaluate autotoxic responses of 3 varieties of alfalfa to the water-soluble extracts(at 4 and 8g/L) from alfalfa ‘Cody’leaf by using agar and filter paper medium in a petri-dish assay. Root length at 5 days after seeding was more sensitive to the extract than was hypocotyl length or seed germination, and was a better parameter of autotoxic effects of alfalfa leaf extracts. Use of an agar medium gave better sensitivity of root length than did use of filter paper. Evaluating tolerance with percent of control was more important indicator than was mean of root length because of significant variation among varieties in root length of control treatment. Bioassay ranked varieties in the following order of tolerance on the basis of relative root length; “Cody” >“ Pioneer 5373” >“ Alfagraze”. Seedling growth from old “Cody” seed was more sensitive to the autotoxic chemical(5) than was that from newly produced seed.

  • PDF

A STUDY OF THE DEPTH OF THE ROOT CONCAVITY AND ROOT SURFACE AREA MEASUREMENT OF THE MAXILLARY FIRST PREMOLAR (상악 제1 소구치의 치근면 함요도 및 치근표면적에 관한 연구)

  • Lim, Sang-Cheol;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.165-177
    • /
    • 1994
  • To investigate the depth of the root concavity and root surface area of the maxillary first premolar, 40 maxillary first premolars were used. All the teeth which extracted because of advanced periodontal disease and orthodontic treatment procedure, were sectioned every 1.5mm from cementoenameljunction to the apex with hard tissue microtome. Each sectioned root was taken photograph with slide film, and projected for measuring with a calibrated digital Curvi-Meter. The root surface area, percentage of the RSA and the linear variation of the RSA were calibrated for each 1.5mm section. Linear variation of the depth of root concavity was measured on mesial and distal root surface for each section using computer-aided digitizer. The results were as follows. 1. The total mean root length of maxillary first premolar was 13.48mm. Mean buccal root length of 2-rooted tooth was 12.59mm, mean palatal root length was 12.73mm, and mean root length of single rooted tooth was 13.78mm. 2. The total mean root surface area of maxillary first premolar was $194.17mm^2$, mean root surface area for 2-rooted tooth was $205.97mm^2$ and mean root surface area for single rooted tooth was $188.49mm^2$. 3. It was 59.93% of the total root surface area that the area from CEJ to coronal 6mm. And, the coronal half of the root length accounted for approximately 71.76% of the total root surface area. 4. Most deepest concavity of the mesial root surface was 0.65mm at apical 3.0mm, 4.5mm level in maxillary first premolar. And, that of the distal root surface was 0.37mm at apical 4.5mm level. 5. All of the maxillary first premolar had mesial root surface concavity. This mesial root surface concavity appeared to be more pronounced in 2-rooted tooth than single rooted tooth.

  • PDF

Crown and root lengths of incisors, canines, and premolars measured by cone-beam computed tomography in patients with malocclusions

  • Kim, Seon-Young;Lim, Sung-Hoon;Gang, Sung-Nam;Kim, Hee-Jin
    • The korean journal of orthodontics
    • /
    • v.43 no.6
    • /
    • pp.271-278
    • /
    • 2013
  • Objective: The purposes of this study were to determine the accuracy of crown and root length measurements of premolars using cone-beam computed tomography (CBCT) and to generate reference CBCT-based data on incisor, canine, and premolar lengths in patients with malocclusions. Methods: Imaging was performed using a CBCT scanner with a 0.292-mm voxel size and 12-bit grayscale. The CBCT-based length measurements were compared with direct measurements of 94 subsequently extracted premolars without metal restorations using the paired t-test. Furthermore, the crown and root lengths of incisors, canines, and premolars in 62 Korean patients with malocclusions were measured using CBCT, and Pearson's correlation coefficients were calculated to examine the relationship between the crown and root length measurements of each tooth type. Results: The differences between the CBCT-based and direct measurements of the extracted premolars were not significant, with 95% limits of agreement of -0.90 to 0.90 mm for crown length and -1.23 to 1.18 mm for root length. Weak positive correlations between the crown and root length measurements were observed for the mandibular canine and premolars. Conclusions: The CBCT-based measurements showed a wider range of limits of agreements for root length than for crown length. The CBCT-based data can be used as a reference for evaluating root length and resorption of teeth without metal restorations in patients with malocclusions.

A STUDY ON THE ACCURACY OF THE ROOT-ZX IN THE CANAL WITH MECHANICALLY FORMED CONSTRICTION (기계적 협착부를 갖는 근관에서 Root-ZX의 정확도에 관한 연구)

  • Kim, Byung-Hyun;Lee, Young-Kyoo;Kim, Young-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.628-632
    • /
    • 1999
  • Currently electronic apex locators have been widely used to determine working length in endodontic treatment. According to Manufacture's recommendation, it is beneficial to find the working length before instrumenting the canal. However, in crown-down pressureless technique, working length of tooth is established following coronal instrumentation 3mm short of radiographic apex. In narrow canals, mechanically formed constriction might be established by coronal instrumentation in some distance from anatomical constriction. The purpose of this study was to evaluate the accuracy of Root-ZX in the canal with mechanical constriction following considerable coronal enlargement with ProFile .06 series. The 40 root canals in 30 extracted mandibular molars were accessed, and their actual length (AL) established by passing a size 10 file just through the minor apical foramen. The teeth were then embedded in an acrylic container with normal saline. The initial canal length(IL) was measured with Root-ZX by negotiating a size 10 file to the apical constriction. The canal was sequentially enlarged to size 40 with ProFile .06 file 3mm short of actual length. The enlarged final canal lengths (FL) were obtained with a size 15 file. The average values of IL, FL were calculated and compared using Repeated measures Analysis of Variance followed Turkey's Studentized Range test. The results were obtained as follows: 1. The initial canal length was 0.12mm shorter than actual canal length(P>0.05). 2. The differences between initial canal length and final canal length were not significant(P>0.05). 3. As a result of this study, regardless of mechanically formed constriction. Root-ZX differentiated between mechanical and anatomic constriction.

  • PDF