• 제목/요약/키워드: root image

검색결과 451건 처리시간 0.029초

PLANT ROOT LENGTH DENSITY MEASUTEMENT USING IMAGE PROCESSING

  • Kim, Giyoung;David H.Vaughan
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.792-801
    • /
    • 1996
  • A thinning algorithm -based image analysis technique was developed to measure corn root lengths. The root length measurement method was evaluated by comparing thread lengths measured by the image analysis system with actual thread lengths. The length measurement method accurately estimated actual thread lengths (less than 2% calculated error). Also, a rapid root length density measurement procedure, which utilizes the above root length measurement method, was developed to estimate corn root length density without washing the roots. Root length densities estimated from the cut soil surface of core samples taken from the field were paired with the root length densities determined from washed roots from the same soil core sample. A linear relationship between these two values was expected and was found. Eliminating the root washing procedure reduces the time required for measuring corn root length density substantially.

  • PDF

Image Analyzer를 이용한 수삼등급의 자동판정 II. 수삼의 적변판정 (Automatic Decision-Making on the Grade of 6 Year-Old Fresh Ginseng (Panax ginseng C. A. Meyer) by an Image Analyzer II. Decision of Rusty Root of Ginseng)

  • 강제용;이명구
    • Journal of Ginseng Research
    • /
    • 제26권1호
    • /
    • pp.6-9
    • /
    • 2002
  • 본 연구는 현재 수삼수납 시 품질검사요원의 관능검사로 판정되고 있는 6년근수삼의 적변판정에 대하여 영상분석기를 이용한 수삼의 적변 자동판정 시스템을 개발하고자 수행하였다. 영상분석기에 의한 수삼 총면적에 대한 grey valuequf 면적비율을 조사하여 이에 대한 회귀 및 판별분석을 실시한 결과, 정상삼과 적변삼을 구별할 수 있는 임계값은 총 면적에 대한 grey value 148에서의 면적비율(G148)로 분석되었으며, 임계값인 G(148)을 이용하여 다음과 같은 판별식을 구하였다. 적변삼의 판별식 : 6.67951$\times$G(148)+3.74122, 정상삼의 판별식 : 2.85942$\times$G(148)+9.95612, 본 판별식의 적중율은 89.8%로 이는 앞으로 계속적인 연구로 적변삼의 판정 적중율을 증가시킬 수 있을 것인 바, 컴퓨터 등 기계에 의한 적변 자동판정의 가능성은 매우 클 것으로 사료된다.

Image Analyzer를 이용한 수삼등급의 자동판정 I. 수삼등급 별 체형과 중량분석 (Automatic Decision-Making on the Grade of 6-Year-Old Fresh Ginseng (Panax ginseng C.A. Meyer) by an Image Analyzer 1. Shape and Weight Analyses according to the Grade of Fresh Ginseng)

  • 강제용;이명구;김요태
    • Journal of Ginseng Research
    • /
    • 제20권1호
    • /
    • pp.65-71
    • /
    • 1996
  • This study was undertaken to evaluate the automatic decision-making on the grading of 6-year-old fresh ginseng (Panax ginseng C.A. Meyer) by an image analyzer. The best input method for the 6-year-old fresh ginseng was under condition of a low resolution (128u 128 pixel) and illumination direction from bottom to up (light box). It was possible to identify the main root, lateral root, and rhizome of fresh ginseng by application of OPEN process in a function of an image analyzer. Finally, we developed the grade decision-making programs, GinP-1. The fitness rates for the fresh ginseng standards which were classified by experts were 94.6, 80.6, 81.5, and 100.0% for 1st, 2nd, 3rd, and 4th grade of fresh ginseng, respectively, and the total time of decision-making was about 4.3 seconds per one root. The decision-making time was reduced to 0.8 seconds per one root by enhancemeat of the Image analyzer, which was tested by the technical company of the image analyzer,'Carl Zeiss (Germany). As a result of this study, the automatic decision-making on the grade of fresh gin send by image analyzer seems to have high possibility.

  • PDF

Machine Vision Technique for Rapid Measurement of Soybean Seed Vigor

  • Lee, Hoonsoo;Huy, Tran Quoc;Park, Eunsoo;Bae, Hyung-Jin;Baek, Insuck;Kim, Moon S.;Mo, Changyeun;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제42권3호
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: Morphological properties of soybean roots are important indicators of the vigor of the seed, which determines the survival rate of the seedlings grown. The current vigor test for soybean seeds is manual measurement with the human eye. This study describes an application of a machine vision technique for rapid measurement of soybean seed vigor to replace the time-consuming and labor-intensive conventional method. Methods: A CCD camera was used to obtain color images of seeds during germination. Image processing techniques were used to obtain root segmentation. The various morphological parameters, such as primary root length, total root length, total surface area, average diameter, and branching points of roots were calculated from a root skeleton image using a customized pixel-based image processing algorithm. Results: The measurement accuracy of the machine vision system ranged from 92.6% to 98.8%, with accuracies of 96.2% for primary root length and 96.4% for total root length, compared to manual measurement. The correlation coefficient for each measurement was 0.999 with a standard error of prediction of 1.16 mm for primary root length and 0.97 mm for total root length. Conclusions: The developed machine vision system showed good performance for the morphological measurement of soybean roots. This image analysis algorithm, combined with a simple color camera, can be used as an alternative to the conventional seed vigor test method.

Application of computer vision for rapid measurement of seed germination

  • Tran, Quoc Huy;Wakholi, Collins;Cho, Byoung-Kwan
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2017년도 춘계공동학술대회
    • /
    • pp.154-154
    • /
    • 2017
  • Root is an important organ of plant that typically lies below the surface of the soil. Root surface determines the ability of plants to absorb nutrient and water from the surrounding soil. This study describes an application of image processing and computer vision which was implemented for rapid measurement of seed germination such as root length, surface area, average diameter, branching points of roots. A CCD camera was used to obtain RGB image of seed germination which have been planted by wet paper in a humidity chamber. Temperature was controlled at approximately 250C and 90% relative humidity. Pre-processing techniques such as color space, binarized image by customized threshold, removal noise, dilation, skeleton method were applied to the obtained images for root segmentation. The various morphological parameters of roots were estimated from a root skeleton image with the accuracy of 95% and the speed of within 10 seconds. These results demonstrated the high potential of computer vision technique for the measurement of seed germination.

  • PDF

Ramdisk를 사용하는 Embedded Linux System에서의 XIP 구현에 대한 연구 (Implementation of XIP Functionality in Embedded Linux with Ramdisk)

  • 정동환;김문회;이창훈;박호준
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2001년도 봄 학술발표논문집 Vol.28 No.1 (A)
    • /
    • pp.115-117
    • /
    • 2001
  • 대부분의 embedded system에서 hard-disk 대용으로 flash memory를 사용하고 있으며, flash device에 압축 커널이미지와 root file system image를 가지고 있다. Booting 고정 중 커널의 압축이 풀리고 메모리에 로드되어 제어를 넘겨받으면 flash memory 상에 존재하는 root file system image를 ramdisk의 image로 로드하여 시스템은 결국 ramdisk에 root file system을 가지게 된다. Ramdisk 상의 프로그램을 실행하기 위해 메모리로 실행파일 이미지를 copy하는 과정을 피하고 ramdisk 상의 이미지를 바로 프로세스의 virtual memory area에 직접 매핑 시켜 주는 XIP(eXection-In-Place)를 구현함으로써 많은 메모리 절감 효과를 얻을 수 있다. 본 연구에서는 ramdisk를 root file system으로 사용하는 embedded system에서의 XIP 구조를 설계하고 구현하였다.

CT사진을 이용한 한국인의 C형 치근관의 분포에 대한 연구 (The distribution of C-shaped canal system in Korean population with CT image)

  • 전록원;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제39권2호
    • /
    • pp.75-79
    • /
    • 2009
  • Purpose: To investigate the incidence and prevalence of C-shaped root canal using computed tomographic images of head and neck in Korean population. Materials and Methods : Regardless of each examination purpose, randomly selected 268 examples which have serial axial computed tomographic images with 8 normal molars in maxilla and mandible were selected and investigated. Defined C-shaped root canal and we could get 82 proper image examples in view of this definition. These were detected and investigated of incidence and prevalence of C-shaped root canal. Results: C-shaped root canals were found in 82 examples among 268 (30.6%) and 147 teeth. They were only found on molar area, and the highest incidence was 37.41% of left mandibular second molars, and the lowest was 2.04% of right maxillary second molars. On prevalence of tooth position, mandibular second molar was the highest, 65% of C-shaped root canal teeth and maxillary second molar was 6% the lowest. Conclusion: 31% of randomly selected CT images no considering check-up reason have C-shaped root canals. The C-shaped root canals of mandibular second molar are found most frequently and they are also detectable on maxilla. On Korean population, C-shaped root canals are one of conditions that have to concern with dental treatment for it appears at a high prevalence relatively. (Korean J Oral Maxillofac Radiol 2009; 39: 75-9)

  • PDF

근광장 측정에서 방사선 사진술의 정확도 (The Accuracy of the Radiographic Method in Root Canal Length Measurement)

  • 조은영;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

Effects of the cone-beam computed tomography protocol on the accuracy and image quality of root surface area measurements: An in vitro study

  • Chanikarn Intarasuksanti;Sangsom Prapayasatok;Natnicha Kampan;Supassara Sirabanchongkran;Pasuk Mahakkanukrauh;Thanapat Sastraruji;Pathawee Khongkhunthian;Kachaphol Kuharattanachai;Kanich Tripuwabhrut
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.325-333
    • /
    • 2023
  • Purpose: The objective of this study was to evaluate and compare the accuracy and image quality of root surface area (RSA) measurements obtained with various cone-beam computed tomography (CBCT) protocols, relative to the gold standard of micro-computed tomography (CT), in an in vitro setting. Materials and Methods: Four dry human skulls were scanned using 8 different protocols, with voxel sizes of 0.15 mm, 0.3 mm, and 0.4 mm. Three-dimensional models of the selected teeth were constructed using CBCT and microCT protocols, and the RSA was automatically measured by the image-processing software. The absolute difference in the percentage of the RSA(%ΔRSA) was calculated and compared across the 8 CBCT protocols using repeatedmeasures analysis of variance. Finally, image quality scores of the RSA measurements were computed and reported in terms of percent distribution. Results: No significant differences were observed in the %ΔRSA across the 8 protocols (P>0.05). The deviation in %ΔRSA ranged from 1.51% to 4.30%, with an increase corresponding to voxel size. As the voxel size increased, the image quality deteriorated. This decline in quality was particularly noticeable at the apical level of the root, where the distribution of poorer scores was most concentrated. Conclusion: Relative to CBCT protocols with voxel sizes of 0.15mm and 0.3mm, the protocols with a voxel size of 0.4 mm demonstrated inferior image quality at the apical levels. In spite of this, no significant discrepancies were observed in RSA measurements across the different CBCT protocols.

SQRI법에 의한 CRT 디스플레이의 화질 평가 (Image quality evaluation of CRT Displays using SQRI method)

  • 조경미;김정희;남궁지나;김현수
    • 한국광학회지
    • /
    • 제11권2호
    • /
    • pp.85-90
    • /
    • 2000
  • CRT디스플레이의 화질 평가에는 위도, 콘트라스트, addressability, 시청거리 등의 다양한 물리적 특성치가 사용된다. 그러나, 최종적인 CRT디스플레이 화질의 비교·평가는 물리적 특성치가 아닌 실제 사용자가 느끼는 화질 즉, 주관적 인지 화질에 의해 이루어진다. 본 논문에서는 4종류 CRT모니터의 SQRI(SQuare Root Integral) 값과 다수의 피험자에 의한 주관적 화질 평가 점수와의 상관성이 비교되었다. 그리고, 이러한 SQRI법의 주관적 화질 평가 척도로서의 타당성을 바탕으로 모니터의 다양한 물리적 특성치가 주관적 화질에 미치는 영향이 검토되었다.

  • PDF