• Title/Summary/Keyword: root axis,

Search Result 185, Processing Time 0.023 seconds

A STUDY ON THE EFFECT OF BASE MATERIALS TO PROTECT THE CERVICAL LEAKAGE OF BLEACHING AGENTS (표백제의 치경부 누출을 방지하기 위한 각종 이장재의 효과에 관한 연구)

  • Song, Byeong-Choon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.585-601
    • /
    • 1994
  • The purpose of this study was to evaluate the ability of several intracoronal base materials to prevent cervical leakage of a bleaching agent into the dentinal tubules and along the root canal. In this study, thirty-two anterior teeth were used. After lingual access was prepared in each tooth, tooth was instrumented with a step-back technique to a Nos. 40-50 using K-type files. All teeth were obturated with a lateral condensation technique. Excess gutta percha was removed with a warm instrument to the facial level of the CEJ. Teeth were divided into four groups : Teeth in control group were not filled with base material. Teeth in groups 1, 2, and 3 had 2mm of gutta percha removed with a warm instrument, then Dycal, Fuki II LC and Z-100 were filled with palstic instruments on the top of the gutta percha respectively. All teeth were bleached for 7 days, fresh bleach was added for another 7 days, then a 10 % methylene blue dye was placed inside the access preparation. They were stored at $37^{\circ}C$ and $100^{\circ}C$ humidity for 5 days. Each tooth was sectioned perpendicular to the long axis using a diamond disk. Initial cuts were made at the most coronal level of facial and lingual CEJ's, then another cuts continued appically in the levels of 0.5mm, 1.5mm, and 2.0mm respectively. The amount of dye leakage through the dentinal tubules was determined at each cut section. In addition, when the cut specimen was determined to be last penetration of any dye, this level was recorded as depth of apical leakage from the coronal terminus of the gutta percha, Dycal, Fuji II LC and Z-100. The acquired data were analyzed by Tukey's Multiple Range Test adn Cochran-Mantel-Haenszel Test to see if there was any statistically significant difference in dye penetration and linear apical leakage among the groups. The results were as follows : 1. Control group at levels of CEJ and 0.5mm, group 3 at level of 1.5mm, and group 2 AND 3 at level of 2.0mm showed the least dye penetration through the facial or lingual dentinal tubules, but there were no significant difference among three groups. 2. Group 2 at levels of CEJ and 0.5mm, group 3 at level of 1.5mm, and group 2 and 3 at level of 2.0mm showed the least dye penetration through the proximal dentinal tubules, but there were no significant difference among control group, group 2, and group 3. 3. Group 1 showed the greatest dye penetration through the facial or lingual and proximal dentinal tubules at all levels, and there were significant difference with other three groups. 4. Control group and group 1 showed 2mm apical dye leakage at facial or lingual and proximal aspects, group 2 showed 1.5mm, and group 3 showed 0.5mm.

  • PDF

INFLUENCE OF POST TYPES AND SIZES ON FRACTURE RESISTANCE IN THE IMMATURE TOOTH MODEL (미성숙 치아 모델에서 포스트의 종류와 크기가 치아의 파절 저항성에 미치는 영향에 관한 연구)

  • Kim, Jong-Hyun;Park, Sung-Ho;Park, Jeong-Won;Jung, Il-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.257-266
    • /
    • 2010
  • The purpose of this study was to determine the effect of post types and sizes on fracture resistance in immature tooth model with various restorative techniques. Bovine incisors were sectioned 8 mm above and 12 mm below the cementoenamel junction to simulate immature tooth model. To compare various post-and-core restorations, canals were restored with gutta-percha and resin core, or reinforced dentin wall with dual-cured resin composite, followed by placement of D.T. LIGHT-POST, ParaPost XT, and various sizes of EverStick Post individually. All of specimens were stored in the distilled water for 72 hours and underwent 6,000 thermal cycles. After simulation of periodontal ligament structure with polyether impression material, compressive load was applied at 45 degrees to the long axis of the specimen until fracture was occurred. Experimental groups reinforced with post and composite resin were shown significantly higher fracture strength than gutta-percha group without post placement (p < 0.05). Most specimens fractured limited to cervical third of roots. Post types did not influence on fracture resistance and fracture level significantly when cement space was filled with dual-cured resin composite. In addition, no statistically significant differences were seen between customized and standardized glass fiber posts, which cement spaces were filled with resin cement or composite resin individually. Therefore, root reinforcement procedures as above in immature teeth improved fracture resistance regardless of post types and sizes.

Fault Detection & SPC of Batch Process using Multi-way Regression Method (다축-다변량회귀분석 기법을 이용한 회분식 공정의 이상감지 및 통계적 제어 방법)

  • Woo, Kyoung Sup;Lee, Chang Jun;Han, Kyoung Hoon;Ko, Jae Wook;Yoon, En Sup
    • Korean Chemical Engineering Research
    • /
    • v.45 no.1
    • /
    • pp.32-38
    • /
    • 2007
  • A batch Process has a multi-way data structure that consists of batch-time-variable axis, so the statistical modeling of a batch process is a difficult and challenging issue to the process engineers. In this study, We applied a statistical process control technique to the general batch process data, and implemented a fault-detection and Statistical process control system that was able to detect, identify and diagnose the fault. Semiconductor etch process and semi-batch styrene-butadiene rubber process data are used to case study. Before the modeling, we pre-processed the data using the multi-way unfolding technique to decompose the data structure. Multivariate regression techniques like support vector regression and partial least squares were used to identify the relation between the process variables and process condition. Finally, we constructed the root mean squared error chart and variable contribution chart to diagnose the faults.

Morphological Characteristics and Occurrence of Yellow Tuft on Zoysiagrass (Zoysia japonica) in Cultivation Fields (들잔디 재배지에 발생한 총생 증상 및 형태적 특성)

  • Cheon, Chang Wook;Han, Jung Ji;Kim, Dong Soo;Kwak, Youn-Sig;Bae, Enu Ji
    • Weed & Turfgrass Science
    • /
    • v.5 no.1
    • /
    • pp.17-22
    • /
    • 2016
  • Yellow tuft symptoms of a dense cluster on zoysiagrass (Zoysia japonica Steud.) occurred extensively at cultivated fields of zoysiagrass sods in Jangsung. The dense cluster of zoysiagrass showed significant morphological changes such as the tufts of shortening of internodes. The disease symptom was spread on a large scale throughout stolon nodes with multiple short leaves and it thrives in broom-like shaped clusters, exhibiting light green or yellow color on their leaves. The dense cluster of zoysiagrass had approximately 5.8 times more leaves on each node of its stolon then healthy zoysiagrass. Also, these zoysiagrass had poorly developed root and stolon caused by the tufts of a dense cluster of shoots. The dense cluster of zoysiagrass were collected for the putative causal agent incubation and upon close observation, it was found that the sporangia took the shape of a lemon, each sporangium was pointed at the end of its axis and was measured to be $60{\sim}96{\times}42{\sim}51{\mu}m$. These findings were analogous to the mycological characteristics of sporangia formed by the pathogen Sclerophthora macrospora. The symptoms of yellow tuft were prevalent in spring and autumn. Therefore, this study aims to present fundamental data in relation to yellow tuft on zoysiagrass in Korea.

A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE (ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구)

  • Lee, Bo-Kum;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.294-302
    • /
    • 2005
  • The purpose of this study was to evaluate the canal configuration after shaping by ProFile. ProTaper and K-Flexofile in simulated resin canals with different angles of curvature. Three types of instruments were used: ProFile. ProTaper. K-Flexofile. Simulated root canals. which were made of epoxy resin. were prepared by ProFile. ProTaper with rotary instrument using a crown-down pressureless technique. and hand instrumentation was performed by K-Flexofile using a step-back technique. All simulated. canals were prepared up to size 25 file at end-point of preparation. Pre and post instrumentation images were recorded with Scanner. Assessment of canal shape was completed with Image Analysis program. Measurements were made at 1. 2. 3. 4. 5. 6. 7. 8. 9 and 10mm from the apex. At each level. outer canal width. inner canal width. total canal width. and amount of transportation from original axis were recorded. Instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA analysis of variance and the Sheffe's test. The result was that ProFile and ProTaper maintain original canal shape regardless of the increase of angle of curvature than K-Flexofile. ProFile show significantly less canal transportation and maintained original canal shape better than ProTaper.

A Study on Design Optimization of an Axle Spring for Multi-axis Stiffness (다중 축 강성을 위한 축상 스프링 최적설계 연구)

  • Hwang, In-Kyeong;Hur, Hyun-Moo;Kim, Myeong-Jun;Park, Tae-Won
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.3
    • /
    • pp.311-319
    • /
    • 2017
  • The primary suspension system of a railway vehicle restrains the wheelset and the bogie, which greatly affects the dynamic characteristics of the vehicle depending on the stiffness in each direction. In order to improve the dynamic characteristics, different stiffness in each direction is required. However, designing different stiffness in each direction is difficult in the case of a general suspension device. To address this, in this paper, an optimization technique is applied to design different stiffness in each direction by using a conical rubber spring. The optimization is performed by using target and analysis RMS values. Lastly, the final model is proposed by complementing the shape of the weak part of the model. An actual model is developed and the reliability of the optimization model is proved on the basis of a deviation average of about 7.7% compared to the target stiffness through a static load test. In addition, the stiffness value is applied to a multibody dynamics model to analyze the stability and curve performance. The critical speed of the improved model was 190km/h, which was faster than the maximum speed of 110km/h. In addition, the steering performance is improved by 34% compared with the conventional model.

Trans-Aortic Flow Turbulence and Aortic Valve Inflammation: A Pilot Study Using Blood Speckle Imaging and 18F-Sodium Fluoride Positron Emission Tomography/Computed Tomography in Patients With Moderate Aortic Stenosis

  • Soyoon Park;Woo-Baek Chung;Joo Hyun O;Kwan Yong Lee;Mi-Hyang Jung;Hae-Ok Jung;Kiyuk Chang;Ho-Joong Youn
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.3
    • /
    • pp.145-149
    • /
    • 2023
  • BACKGROUND: 18F-sodium fluoride positron emission tomography/computed tomography (18F-NaF PET/CT) has been proven to be useful in identification of microcalcifications, which are stimulated by inflammation. Blood speckle imaging (BSI) is a new imaging technology used for tracking the flow of blood cells using transesophageal echocardiography (TEE). We evaluated the relationship between turbulent flow identified by BSI and inflammatory activity of the aortic valve (AV) as indicated by the 18F-NaF uptake index in moderate aortic stenosis (AS) patients. METHODS: This study enrolled 18 moderate AS patients diagnosed within the past 6 months. BSI within the aortic root was acquired using long-axis view TEE. The duration of laminar flow and the turbulent flow area ratio were calculated by BSI to demonstrate the degree of turbulence. The maximum and mean standardized uptake values (SUVmax, SUVmean) and the total microcalcification burden (TMB) as measured by 18F-NaF PET/CT were used to demonstrate the degree of inflammatory activity in the AV region. RESULTS: The mean SUVmean, SUVmax, and TMB were 1.90 ± 0.79, 2.60 ± 0.98, and 4.20 ± 2.18 mL, respectively. The mean laminar flow period and the turbulent area ratio were 116.1 ± 61.5 msec and 0.48 ± 0.32. The correlation between SUVmax and turbulent flow area ratio showed the most positive and statistically significant correlation, with a Pearson's correlation coefficient (R2) of 0.658 and a p-value of 0.014. CONCLUSIONS: The high degree of trans-aortic turbulence measured by BSI was correlated with severe AV inflammation.

The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA (유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상)

  • Choi, In-Ho;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.213-230
    • /
    • 2008
  • The aim of this study was to analyze the initial movement and the stress distribution of each tooth and periodontal ligament during the lingual lever-arm retraction of 6 maxillary incisors using FEA. Two kinds of finite element models were produced: 2-properties model (simple model) and 24-properties model (multi model) according to the material property assignment. The subject was an adult male of 23 years old. The DICOM images through the CT of the patient were converted into the 3D image model of a skull using the Mimics (version 10.11, Materialise's interactive Medical Image Control System, Materialise, Belgium). After series of calculating, remeshing, exporting, importing process and volume mesh process was performed, FEA models were produced. FEA models are consisted of maxilla, maxillary central incisor, lateral incisor, canine, periodontal ligaments and lingual traction arm. The boundary conditions fixed the movements of posterior, sagittal and upper part of the model to the directions of X, Y, Z axis respectively. The model was set to be symmetrical to X axis. Through the center of resistance of maxilla complex, a retraction force of 200g was applied horizontally to the occlusal plane. Under this conditions, the initial movements and stress distributions were evaluated by 3D FEA. In the result, the amount of posterior movement was larger in the multi model than in the simple model as well as the amount of vertically rotation. The pattern of the posterior movement in the central incisors and lateral incisors was controlled tipping movement, and the amount was larger than in the canine. But the amount of root movement of the canine was larger than others. The incisor rotated downwardly and the canines upwardly around contact points of lateral incisor and canine in the both models. The values of stress are similar in the both simple and multi model.

Evaluation of beam delivery accuracy for Small sized lung SBRT in low density lung tissue (Small sized lung SBRT 치료시 폐 실질 조직에서의 계획선량 전달 정확성 평가)

  • Oh, Hye Gyung;Son, Sang Jun;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate beam delivery accuracy for small sized lung SBRT through experiment. In order to assess the accuracy, Eclipse TPS(Treatment planning system) equipped Acuros XB and radiochromic film were used for the dose distribution. Comparing calculated and measured dose distribution, evaluated the margin for PTV(Planning target volume) in lung tissue. Materials and Methods : Acquiring CT images for Rando phantom, planned virtual target volume by size(diameter 2, 3, 4, 5 cm) in right lung. All plans were normalized to the target Volume=prescribed 95 % with 6MV FFF VMAT 2 Arc. To compare with calculated and measured dose distribution, film was inserted in rando phantom and irradiated in axial direction. The indexes of evaluation are percentage difference(%Diff) for absolute dose, RMSE(Root-mean-square-error) value for relative dose, coverage ratio and average dose in PTV. Results: The maximum difference at center point was -4.65 % in diameter 2 cm size. And the RMSE value between the calculated and measured off-axis dose distribution indicated that the measured dose distribution in diameter 2 cm was different from calculated and inaccurate compare to diameter 5 cm. In addition, Distance prescribed 95 % dose($D_{95}$) in diameter 2 cm was not covered in PTV and average dose value was lowest in all sizes. Conclusion: This study demonstrated that small sized PTV was not enough covered with prescribed dose in low density lung tissue. All indexes of experimental results in diameter 2 cm were much different from other sizes. It is showed that minimized PTV is not accurate and affects the results of radiation therapy. It is considered that extended margin at small PTV in low density lung tissue for enhancing target center dose is necessary and don't need to constraint Maximum dose in optimization.

Determination of Electron Beam Output Factors of Individual Applicator for ML-15MDX Linear Accelerator (선형가속기 ML-15MDX의 각 Applicator에 대한 전자선 출력선량 계수 결정)

  • Park, Tae-Jin;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.87-99
    • /
    • 1994
  • Purpose : The determination of electron beam output factor was investigated from individual applicator for various energy of ML-15MDX linear accelerator. The output factor of electron beam was extended from square to rectangular field in individual applicator size through with a least-square fit to a polynomial expression. Materials : In this experiments. the measurement of output was obtained from 2${\times}$cm$^2$ to 20${\times}$20cm$^2$ of field size in different applicator size for 4 to 15 MaV electron beam energy. The output factor was defined as the ratio of maximum dose output on the central axis of the field of individual applicator size to that of a given field size. Applicator factors were derived from comparing with the output dose of reference field size 10${\times}$10cm$^2$. The thickness of block was specially designed as 10mm in thickness of Lipowitz metal for field shaping in all electron energy. Two types of output curves are included as output factors versus side of square fields and that of variable side length for X and Y in one-dimensional to compare the expected values to that of experiments. Results : Expected output factors of rectangular which was derived from that of square fields in individual applicator size from 2${\times}$2cm$^2$ to 20${\times}$20cm$^2$ in different electron energy was very closed to that of experimental measurements within 2% uncertainty. However 1D method showed a 3% discrepancy in small rectangular field for low energy electron beam. Conclusion : Emperical non-linear polynomial regressions of square root and 1D method were performed to determin the output factor in various field size and electron energy. The expected output of electron beam of square root method for square field and 1D method for rectangular field were very closed to that of measurement in all selected electron beam energy.

  • PDF