• Title/Summary/Keyword: roof control

Search Result 272, Processing Time 0.028 seconds

Monitoring on the Soils and Plant Growth in Modular Sloped Rooftop Greening System (모듈형 경사지붕 녹화시스템의 토양과 식물생육 모니터링)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.5
    • /
    • pp.53-67
    • /
    • 2011
  • The major objective of this study was to quantify the effects of substrate depth and substrate composition on the development of sedum etc., in a sloped rooftop (6 : 12 pitch) environment during a 4-year period. The experiment was conducted from 2006 October to 2010 December under several conditions without soil erosion control : two substrate depth (5cm, 10cm), four substrate composition (A5N3C2, A3N3C4, A6C4, G5L3C2: A: artificial lightweight soil, N : natural soil, G : granite decomposed soil, C : leave composite, L : loess), four sloped roof direction ($E40^{\circ}W$, $W40^{\circ}N$, $S40^{\circ}W$, $N40^{\circ}E$). In this experiment 4 sedum etc., were used: Sedum sarmentosum, Sedum kamtschaticum, Sedum rupestre, Sedum telephium, flowering herbs (mixed seed : Taraxacum platycarpum, Lotus corniculatus, Aster yomena, Aster koraiensis), western grasses (mixed seed : Tall fescue, Creeping redfescue, Bermuda grass, Perennial ryegrass). The establishment factor had two levels : succulent shoot establishment (sedum), seeding (flowering herbs, western grasses). 1. Enkamat, as it bring about top soil exfoliation, was unsuitable material for soil erosion control. 2. Sedum species exhibited greater growth at a substrate depth of 10cm relative to 5cm. All flowering herbs and western grasses established only at a substrate depth of 5cm were died. A substrate depth of 5cm was not suited in sloped rooftop greening without maintenance. If additional soil erosion control will be supplemented, a substrate depth of 10cm in sloped rooftop greening without maintenance was considered suitable. 3. For all substrate depth and composition, the most abundant species was Sedum kamtschaticum. The percentage of surviving Sedum kamtschaticum was 73.4% at a substrate depth of 10cm in autumn 2007 one year after the roof vegetation had been established. But the percentage of surviving other sedum were 33.3%~51.9%, therefor mulching for soil erosion control was essential after rooftop establishment in extensive sloped roof greening was proved. To raise the ratio of plant survival, complete establishment of plant root at substrate was considered essential before rooftop establishment. 4. There was a significant interaction between biomass and substrate moisture content. There were also a significant difference of substrate moisture and erosion among substrate composition. The moisture content of A6C4 was highest, the resistance to erosion of A5N3C2 was highest among substrate composition. The biomass of plants were not significantly higher in A5N3C2 and A6C4 relative to A3N3C4 and G5L3C2, For substrate moisture and erosion resistance, A5N3C2 and A6C4 were considered suitable in sloped rooftop greening without maintenance. 5. There were significant difference among roof slope direction on the substrate moisture. Especially, the substrate moisture content of $S40^{\circ}W$ was lower relative to that of $N40^{\circ}E$, that guessed by solar radiation and erosion.

Effects of Shading Rate and Method of Inside Air Temperature Change in Greenhouse (차광율 및 차광방법이 온실내부의 온도변화에 미치는 영향)

  • 이석건;이현우;김길동;이종원
    • Journal of Bio-Environment Control
    • /
    • v.10 no.2
    • /
    • pp.80-87
    • /
    • 2001
  • This study was conducted to provide basic data for the design of shading facility of greenhouse. The proper distance between external shading screen and roof surface, transmissivity of shading materials, and shading effects of external and internal shadings were analyzed. About a distance of 10 cm between inclined external shading screen and roof surface was enough to guarantee the external shading effect in the greenhouse without roof vent. The inside temperature of greenhouse installed with 85% internal shading screen was lower the maximum of 4$^{\circ}C$ and mean of 2$^{\circ}C$ than that with 55% internal shading screen in both natural ventilation and no ventilation condition. The difference of soil temperature between shading and no shading greenhouse was great, but the difference by shading rate or shading method was small. The performance of external shading for controlling inside temperature down was superior to that of the internal shading. The externally inclined shading screen parallel to the roof surface of greenhouse was more effective than the externally horizontal shading screen in controlling inside temperature of greenhouse without roof vent.

  • PDF

Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse (플라스틱 단동온실의 천창 종류에 따른 자연환기 효과)

  • Rasheed, Adnan;Lee, Jong Won;Kim, Hyeon Tae;Lee, Hyun Woo
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.225-233
    • /
    • 2019
  • In the summer season, natural ventilation is commonly used to reduce the inside air temperature of greenhouse when it rises above the optimal level. The greenhouse shape, vent design, and position play a critical role in the effectiveness of natural ventilation. In this study, computational fluid dynamics (CFD) was employed to investigate the effect of different roof vent designs along with side vents on the buoyancy-driven natural ventilation. The boussinesq hypothesis was used to simulate the buoyancy effect to the whole computational domain. RNG K-epsilon turbulence model was utilized, and a discrete originates (DO) radiation model was used with solar ray tracing to simulate the effect of solar radiation. The CFD model was validated using the experimentally obtained greenhouse internal temperature, and the experimental and computed results agreed well. Furthermore, this model was adopted to compare the internal greenhouse air temperature and ventilation rate for seven different roof vent designs. The results revealed that the inside-to-outside air temperature differences of the greenhouse varied from 3.2 to $9.6^{\circ}C$ depending on the different studied roof vent types. Moreover, the ventilation rate was within the range from 0.33 to $0.49min^{-1}$. Our findings show that the conical type roof ventilation has minimum inside-to-outside air temperature difference of $3.2^{\circ}C$ and a maximum ventilation rate of $0.49min^{-1}$.

Assessment of Plant Drought Tolerance for Extensive Green Roof (저관리 경량형 옥상녹화 식물의 내건성 평가)

  • Park, Seong-Sik;Choi, Jaehyuck;Park, Bong-Ju
    • Korean Journal of Organic Agriculture
    • /
    • v.24 no.4
    • /
    • pp.787-795
    • /
    • 2016
  • The purpose of this study was to assess drought tolerance of groundcover plants for extensive green roof. Form July to November 2013, plant height, chlorophyll content, soil moisture, evapotranspiration and survival rate was measured. As results, after unirrigation started, Aster koraiensis reached 0% of soil moisture earliest followed by Sedum kamtschaticum, Hemerocallis fulva, Hylotelephium spectabile, Iris sanguinea, Hosta longipes and control. Among the plants, A. koraiensis withered earliest on 19th day of unirrigation experiment, followed by H. longipes and H. fulva (27th day); and I. sanguinea (29th day). S. kamtschaticum and H. spectabile survived even after 120th day of the experiment. As for chlorophyll content, I. sanguinea showed constant values in early stage than rapidly decreased right before its withering. Chlorophyll content of A. koraiensis and H. fulva showed rapid decrease from the beginning, while that of H. spectabile and S. kamtschaticum showed continuous reduction for first 30 days and the reduction was slowed down since then. In conclusion, H. longipes, I. sanguinea and H. fulva were found most applicable for extensive green roof considering scenic aspect.

A Study of the first stage Rain-Water exclusion by hydrophilic coating (친수코팅에 의한 초기우수 배제에 관한 연구)

  • Choi, Won Jun;Kim, Young Jung;Shim, Young Mean;Oh, Hye Cheol;Rhee, Dong Seok
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.189-197
    • /
    • 2006
  • Water shortage as well as water control problems including urban flood and drought have led to developing technologies for rainwater utilization in order to provide a sustainable water supply. However, relatively few works have been done to improve the water quality during rainwater utilization. Therefore, in this study, the characteristics of rainwater were examined in terms of pollutant concentrations and outflow rate. A experimental rain and roof model($1m{\times}1m$) were produced to evaluate wash-off properties of pollutants. And rainfall intensity were standardized in 10 mm/hr, a experimental model roof catchment surface were coated in $TiO_2$ photocatalyst. Samples of runoff rainwater collected from a experimental model were analyzed for physicochemical parameters such as Turbidity, Suspended Solid, EC. The results show that the first flush of rainwater contains substantial amount of contaminants that potentially pollute the whole rainwater. Surface treatment of roof catchment area using $TiO_2$ photocatalyst allowed a better runoff property of rainwater because of its improved hydrophilicity.

  • PDF

Wind tunnel study on drag reduction of a 5 ton truck using additive devices (유동제어용 부착물을 이용한 5톤 화물차의 항력 감소에 관한 실험적 연구)

  • Lee, EuiJae;Hwang, BaeGeun;Kim, JeongJae;Lee, SangJoon
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • There have been many attempts to reduce the cost of transportation. Especially, drag reduction of heavy vehicles has enormous influence on energy saving by reducing the driving power of the vehicles. In this study, the effects of drag-reducing additive devices such as side skirt, boat tail and cab-roof fairing on the drag reduction of a 5 ton truck model were experimentally investigated. The aerodynamic performance of these flow-control devices attached to heavy vehicle was evaluated through wind tunnel test. In addition, flow patterns around the truck model were visualized by using smoke tube method. The drag coefficient is reduced by up to 5.7%, 7.16% and 22.2% by the side skirt, boat tail and cab-roof fairing, respectively. The interactive effect of the side skirt and boat tail was also investigated.

A Study on Green Roofing Applied Artificial Soil Containing Recycled Materials - Focused on the Effects on the Growth of Plants by Difference of Soil Mixture Ratio - (재활용재료를 포함한 옥상녹화용 인공토양의 성능평가 - 토양배합비가 자생식물 생육에 미치는 영향을 중심으로 -)

  • Kim, Kyung-Hoon;Koh, Jeung-Hyun;Kim, Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.5
    • /
    • pp.119-130
    • /
    • 2013
  • The objective of this study was to analyze an availability of green roof soil based on the bottom ash soil and compost using sludge derived from food factory as comparing and analysing the growth of native plants. Analysing the physical properties and chemical resistance of 12 different type mixing soils which is mainly used in green roof, selected 4 types of soil, experiments were conducted to compare plant growth. The growth status of the plant showed the most superior of the soil 13(control), next soil 9(Pearlite : Bottom Ash : Compost = 20 : 60 : 20) and soil 10(Pearlite : Zeolite : Compost = 60 : 20 : 20) This result showed that native plants grow well in the soil based on the bottom ash and compost using sludge derived from food factory, and this soil type is determined that is available the green roof soil.

An Optimal Placement of passive Constrained Layer Damping Treatment for Vibration Suppression of Automotive Roof (차량루프의 진동저감을 위한 수동구속감쇠처리의 위치 최적화)

  • Lee, Ki-Hwa;Kim, Chan-Mook;Kang, Young-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.349-353
    • /
    • 2004
  • A study on optimal placement of constrained layer damping treatment for vibration control of automotive panels is presented. The effectiveness of damping treatment depends upon design parameters such as choice of damping materials, locations and size of the treatment. This paper proposes a CAE (Computer Aided Engineering) methodology based on finite element analysis to optimize damping treatment. From the equivalent modeling technique, it is found that the best damping performance occurs as the viscoelstic patch is placed by means of the modal strain energy method of bare structural panels to identify flexible regions, which in turn facilitates optimizations of damping treatment with respect to location and size. Different configurations of partially applied damping layer treatment have been analyzed for their effectiveness in realizing maximum system damping with minimum mass of the applied damping material. Moreover, simulated frequency response function of the automotive roof with and without damping treatments are compared, which show the benefits of applying damping treatment. Finally, the optimized damping treatment configuration is validated by comparing the locations and the size of the treatment with that of an experimental modal test conducted on roof compartment.

  • PDF

Conceptual Application Schemes of Seismic Isolation Techniques to Hanok (한옥의 면진기법 적용 방안에 대한 개념적 고찰)

  • Park, Bum-Soo;Kim, Yeong-Min;Hur, Moo-Won;Lee, Sang-Hyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.1
    • /
    • pp.137-146
    • /
    • 2020
  • In this study, various application schemes of seismic isolation system which can be applied to Hanok have been studied by analyzing its structural characteristics under seismic load. Structural stability of Hanok is more required against seismic load as Hanok becomes long-spanned and multi-storied. To meet this goal, it becomes necessary to study more advanced technology such as seismic isolation design as well as seismic control design and seismic resistant design suitable to Hanok. Seismic isolation systems have been successfully applied to RC and steel structures to improve structural performance during earthquakes. Based on these previous study, we proposed four application schemes of seismic isolation design suitable for Hanok and analyzed their structural characteristics and applicability to Hanok in conceptual level based on its structural characteristics. The proposed four schemes are base isolation method, ground isolation method, roof isolation method and intermediate-story isolation method. The applicability of the proposed method was evaluated by performing boundary nonlinear dynamic analysis to the typical Hanok for the two types of isolation method, that is, ground isolation method and roof isolation method, and the results showed that the proposed methods produced good performance enough to be applied to Hanok.

Predictive Model of Micro-Environment in a Naturally Ventilated Greenhouse for a Model-Based Control Approach (자연 환기식 온실의 모델 기반 환기 제어를 위한 미기상 환경 예측 모형)

  • Hong, Se-Woon;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.181-191
    • /
    • 2014
  • Modern commercial greenhouse requires the use of advanced climate control system to improve crop production and to reduce energy consumption. As an alternative to classical sensor-based control method, this paper introduces a model-based control method that consists of two models: the predictive model and the evaluation model. As a first step, this paper presents straightforward models to predict the effect of natural ventilation in a greenhouse according to meteorological factors, such as outdoor air temperature, soil temperature, solar radiation and mean wind speed, and structural factor, opening rate of roof ventilators. A multiple regression analysis was conducted to develop the predictive models on the basis of data obtained by computational fluid dynamics (CFD) simulations. The output of the models are air temperature drops due to ventilation at 9 sub-volumes in the greenhouse and individual volumetric ventilation rate through 6 roof ventilators, and showed a good agreement with the CFD-computed results. The resulting predictive models have an advantage of ensuring quick and reasonable predictions and thereby can be used as a part of a real-time model-based control system for a naturally ventilated greenhouse to predict the implications of alternative control operation.