• Title/Summary/Keyword: roof control

Search Result 272, Processing Time 0.039 seconds

Estimation of Wind Pressure Coefficients on Even-Span Greenhouse Built in Reclaimed Land according to Roof Slop using Wind Tunnel (풍동을 이용한 간척지 내 양지붕형 온실의 지붕 경사에 따른 풍압계수 평가)

  • Kim, Rack-Woo;Kim, Dong-Woo;Ryu, Ki-Cheol;Kwon, Kyeong-Seok;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.269-280
    • /
    • 2014
  • To cope with increasing of vegetables and flowers consumptions, horticulture facilities have been modernized. Korea government recently announced construction plan of new greenhouse complex at reclaimed land. However wind characteristics of reclaimed land is totally different from those of inland, wind pressure on greenhouse built in reclaimed land should be carefully evaluated to secure structural safety on the greenhouse. In this study, as a first step, wind pressure coefficient and local wind pressure coefficient on even-span greenhouse were measured using wind tunnel test. ESDU was adopted to realize wind characteristics of reclaimed land such as wind and turbulence profiles. From the wind tunnel test, when wind direction was 0 degree, it was concluded that KBC2009 standard underestimated scale of wind pressure coefficients at roof area of greenhouse whereas NEN-EN2002 standard underestimated those at every surface of greenhouse. When wind direction was 90 degree, both standards did not well reflect the characteristics of wind pressure distribution. From the analysis of local wind pressure coefficients according to wind direction conditions, design of covering, glazing bar of greenhouse where large effects of the local wind pressure were estimated should be well established. Wind pressure coefficients and local wind pressure coefficients according to parts of the greenhouse were finally suggested and these results could be practically used for suggesting new design standards of greenhouse.

Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation (CFD 검증을 위한 풍동 및 PIV를 이용한 자연환기식 온실 내부 공기유동 분석)

  • Ha, Jung-Soo;Lee, In-Bok;Kwon, Kyeong-Seok;Ha, Tae-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.391-400
    • /
    • 2014
  • The number of large scale greenhouses has recently been increasing to cope with mass consumption of agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from $1m{\cdot}s^{-1}$ to $1.5m{\cdot}s^{-1}$, air velocities inside the greenhouse which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.

Evaluation of Natural Ventilation Performance for Multi-span Plastic Greenhouses (다연동 플라스틱 온실의 자연환기성능 평가)

  • Nam, Sang-Woon;Kim, Young-Shik;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.7-12
    • /
    • 2013
  • Environmental measurements in the many different types of horticultural farms were carried out to evaluate the ventilation performance for multi-span plastic greenhouses according to the eaves height, the number of spans, the existence of side wall vents and the position of roof vents. Hydroponic tomatoes were being cultivated in all experimental greenhouses, and ventilation rates of the greenhouses were analyzed by the heat balance method. It showed that the ventilation rate in the greenhouse with 4 m eaves height increased about 22% compared to the greenhouse with 2 m eaves height. The ventilation rate in the greenhouse with 9 spans decreased about 17% compared to the greenhouse with 5 spans. In the greenhouse with 9 spans, if there were no side wall vents, the ventilation rate showed about a third of the case that side wall vents were open. Overall, as the eaves height was higher and the number of spans was smaller in multi-span greenhouses, the natural ventilation performance was better. And the ventilation performance was best in the greenhouse which the eaves height was high and the position of roof vents was ridge, not gutter. Therefore, in order to maximize the natural ventilation performance, multi-span plastic greenhouses need to improve their structures such as that make the eaves height higher, place the roof vents on the ridge, install the side wall vents as much as possible, and the number of spans is limited to about 10 spans.

Development of Design Technology of Korean Style Air-Inflated Double-Layer Plastic Greenhouse (한국형 공기주입 이중피복 플라스틱온실의 설계기술 개발)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Nam, Hyo-Seok;Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.185-191
    • /
    • 2009
  • The construction of experimental greenhouses, operating test, and analysis on variation of different environment factors were conducted to provide fundamental data for design of Korean style air-inflated double-layer plastic greenhouse. The development of technology of attaching plastic to the structure and fasteners to be able to keep airtight was required in order to maintain proper static pressure in air space of double layer coverings. The insulation effect of air inflated greenhouse was better than conventional type. The temperature of arch type roof was greater about $2^{\circ}C$ than peach type roof in air inflated greenhouse. It was recommended that the plastic should be attached at the edges without clearance length in order to ease installation and raise airtightness of double layer coverings. The transmittance of arch type roof was greater than peach type in air inflated one span greenhouse. The transmittance of air inflated greenhouse was greater than conventional type due to frame ratio and distance between double layers in three span greenhouse. The condensation occurred on conventional type greenhouse was more than air inflated type. It was required to examine for a long time in order to analyze it quantitatively.

Distribution of Wind Force Coefficients on the Three-span Arched House (아치형 3연동하우스의 풍력계수 분포에 관한 연구)

  • 이현우;이석건
    • Journal of Bio-Environment Control
    • /
    • v.2 no.1
    • /
    • pp.46-52
    • /
    • 1993
  • The wind pressure distributions were analyzed through the wind tunnel experiment to provide fundamental criteria for the structural design on the three-span arched house according to the wind directions. In order to investigate the wind force distribution, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated from the experimental data. The results obtained are as follows : 1. The variation of the wind force with the wind directions on the side walls was the greatest at the upwind edge of the walls. The change of pressure from the positive to the negative on the side walls occurred at the wind direction of 30$^{\circ}$ in the first house and 60$^{\circ}$ in the third house. 2. The maximum negative wind force along the length of the roof appeared at the length ratio of 0-0.2, when the wind directions were 90$^{\circ}$ in the first house, 60$^{\circ}$ in the second house and 30$^{\circ}$ in the third house. 3. The maximum negative wind force along the width of the roof appeared at the width ratio and the wind direction of 0.4 and 0$^{\circ}$ in the first house, 0.4-0.6 and 30$^{\circ}$ in the second house and 0.6 and 30$^{\circ}$ in the third house, respectively. 4. The maximum mean positive and negative wind forces occurred at the wind direction of 60$^{\circ}$ and 30$^{\circ}$, respectively, on the side walls of the first house, and the maximum mean negative wind force on the roof occurred at the wind direction of 30$^{\circ}$ in third house. 5. The maximum drag and lift forces occurred at the wind direction of 30$^{\circ}$, and the maximum lift force appeared in the third house. 6. The parts to be considered for the local wind forces were the edges of the walls, the edges of the x-direction of the roofs, and the locations of the width ratio of 0.4 of the first and third house and the center of the width of the second house for the y-direction of the roofs.

  • PDF

Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse (이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The objective of the present study is to provide data needed to find double covering method to be able to improve environment of temperature, humidity and PPF in tomato greenhouse. The distribution charts of temperature, humidity and PPF which were measured in environment control conditions such as thermal insulation, air heating, roof ventilation and air fog cooling in conventional and air inflated double layers greenhouses were drawn and analysed. The thermal insulation effect of the air inflated greenhouse was the same as that of conventional greenhouse because the temperature between insulation curtain and roof covering material was equal in heating season. The ventilation effect of the air inflated greenhouse was superior to the conventional greenhouse. The temperature distribution in the fog cooled greenhouse was uniform and the cooling effect was about $3.5^{\circ}C$. The condensation on the roof covering surface could be controlled by removing the moisture between insulation curtain and roof covering by using humidifier. The PPF of conventional greenhouse was more decreased than the air inflated greenhouse as time went by because the transmittance of conventional greenhouse declined by dust collected on the inside plastic film owing to rolling up and down operation for ventilation.

An Experimental Study on the Required Performances of Roof Concrete Placed in the In-ground LNG Storage Tank (지하식 LNG 저장탱크의 지붕 콘크리트의 요구성능에 관한 실험적 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.339-345
    • /
    • 2013
  • This study is to derive from the required performances and the optimum mix proportion of the roof concrete placed in the in-ground LNG storage tank with a capacity of 200000 $m^3$, and propose the actual data for site concrete work. The concrete placing work without sliding and segregation in the fresh concrete condition is very important because the slope of domed roof is varied in the large range by its curvature. Also the control of hydration heat and the strength development at test ages are classified with massive section about 1.4 m thick and considered to the pre-stressing work and removal of air support after concrete placing work. Considering above condition, slump range is selected $100{\pm}25$ mm under the slope $20^{\circ}$ and $150{\pm}25$ mm over the slope $20^{\circ}$ s until 60 minutes of elapsed time. Also, the roof concrete is satisfied with compressive strength range including design strength at 91 days (30 MPa), pre-stressing work at 7 days (10 MPa), air support removal work at 21 days (14 MPa). Replacement ratio of limestone powder is determined by confined water ratio test and main design factors include water-cement ratio (W/C), sand-aggregate ratio and dosage of admixture. As test results, the optimum mix proportion of the roof concrete used low heat cement is as followings. 1) Replacement ratio of limestone powder 25% by confined water ratio test 2) Water-cement ratio 57.8% 3) Sand-aggregate ratio 42.0%. Also, test results for the adiabatic temperature rising test is satisfied with its criteria and shown the lower value compared to preceding storage tank (TK-13, 14). These required performances and the optimum mix proportion is to apply the actual construction work.

Daylighting Controls of Korean Traditional Houses built in Chosun Dynasty especially on examples located in northern Gyeongbuk province (경북북부지역 전통 양반가옥의 채광조절 기능에 관한 연구 -처마, 창호(窓戶), 창호지(窓戶紙)를 중심으로-)

  • Kim, Gon;Koo, Jae-Oh
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.79-85
    • /
    • 2004
  • There is something valuable in Korean traditional architecture that does not change even after more than a number of years. Each design element of traditional houses has its own role to embody natural, healthy, and environment-friendly architectural planning. With traditional already-built examples located in the northern area of Gyeongbuk province, this study attempts to untangle some of the daylighting control issues in opening design. By looking at more than just photometric materials, at some threshold level, the whole of daylighting control characteristics of their openings is being surveyed from the viewpoint of geometric relationship between their roof structures and windows. As a glazing material, in addition, Korean traditional window covering paper, Changhoji, is evaluated for its transmittal performance under artificial and real skies as well.

Decision of SSI Network dimension for Safety based ODLM(LDT) installation (안전성 기반 ODLM(LDT) 설치를 위한 SSI 네트워크 규모 결정)

  • Min, Geun-Hong;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.797-802
    • /
    • 2008
  • High Speed Rail Train Control System consists of CTC, IXL and ATC. IXL and ATC perform train control and command via interchanging relevant information between a signal room and CTC. However, it is proved that IXL and ATC are attributed to train delay error since those systems are highly sensitive to trackside conditions. Especially, network error on IXL blocks transmitting signal information to adjacent signal room so that its effects give rise to system overall problems. In order to figure out the measures for which minimizing the occurrence rate of train delay error due to HSR TCS, This paper is performed analysis on communication network structure, the length of SSI network roof and SSI-TFM distance by examining and analyzing the error cases related to IXL in a network aspect.