• Title/Summary/Keyword: roof control

Search Result 272, Processing Time 0.027 seconds

Heat Budget Analysis of Light Thin Layer Green Roof Planted with Zoysia japonica (한국잔디식재 경량박층형 옥상녹화의 열수지 해석)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.190-197
    • /
    • 2012
  • The purpose of this study was to evaluate thermal environment and heat budget of light thin layer green roof through an experiment in order to quantify its heat budget. Two concrete model boxes($1.2m(W){\times}1.2m(D){\times}1.0m(H)$) were constructed: One experiment box with Zoysia japonica planted on substrate depth of 10cm and one control box without any plant. Between June 6th and 7th, 2012, outside climatic conditions(air temperature, relative humidity, wind direction, wind speed), evapotranspiration, surface and ceiling temperature, heat flux, and heat budget of the boxes were measured. Daily maximum temperature of those two days was $29.4^{\circ}C$ and $30^{\circ}C$, and daily evapotranspiration was $2,686.1g/m^2$ and $3,312.8g/m^2$, respectively. It was found that evapotranspiration increased as the quantity of solar radiation increased. A surface and ceiling temperature of those two boxes was compared when outside air temperature was the greatest. and control box showed a greater temperature in both cases. Thus it was found that green roof was effective in reducing temperature. As results of heat budget analysis, heat budget of a green roof showed a greater proportion of net radiation and latent heat while heat budget of the control box showed a greater proportion of sensible heat and conduction heat. The significance of this study was to analyze heat budget of green roof temperature reduction. As substrate depth and types, species and seasonal changes may have influences on temperature reduction of green roof, further study is necessary.

Supervisory control of reheating furnace

  • Kim, Young-Il;Min, Kwang-Gi;Nam, In-Sik;Chang, Kun-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.538-541
    • /
    • 1995
  • In steel works, reheating furnace is an essential part of a rod mill plant and it treats various types of billets continuously. Although getting an optimal setting for a single billet is simple, control setting for whole groups of billets is a difficult task. In this work, we studied a detail mathematical model and optimal control setting of reheating furnace. As the mathematical model of each billet is a partial differential equation, on-line control is almost impossible for the whole billets charged into the furnace. Therefore, we tried to provide a guideline for optimal setting value of the roof(index) temperature for the target billets which account for about 20% of the charged billets.

  • PDF

Analysis on the Ventilation Performance of Single-span Tomato Greenhouse with Roof Windows (천창을 설치한 토마토 재배 단동 온실의 환기성능 분석)

  • Nam, Sang-Woon;Kim, Young-Shik;Both, Arend-Jan
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.78-82
    • /
    • 2011
  • Ventilation rates, inside and outside weather data were measured in a arch-shape single-span plastic greenhouse growing tomatoes. On the roof of the experimental greenhouse, round windows which have a diameter of 0.6 m were installed at intervals of 8m. It showed that the number of air changes in this greenhouse were average 0.17 volumes per minute and in the range of 0.02 to 0.32 volumes per minute. These air changes are insufficient to meet the recommended ventilation rate for commercial greenhouses, and it is estimated that interval of 6 m is appropriate for spring or fall season. For summer season, it is necessary to narrow the space or to enlarge the open area of roof windows. Using the heat balance model, the evapotranspiration coefficients of greenhouse tomatoes were estimated from experimental ventilation data, overall heat transfer and solar radiation. It showed that the evapotranspiration coefficients were average 0.62 and in the 0.39 to 0.85 range. We suggest applying 0.6 as the evapotranspiration coefficient in design of ventilation for the single-span tomato greenhouses.

Growth Characteristics of Lychnis Cognate and Soil Moisture by Organic Mulching Material Type in Extensive Green Roof System (저관리 경량형 옥상녹화에서 유기물 멀칭재 유형에 따른 토양수분과 동자꽃의 생육 특성)

  • Park, Sun Young;Chae, Ye Ji;Choi, Seung Yong;Yoon, Yong Han;Ju, Jin Hee
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.2
    • /
    • pp.107-112
    • /
    • 2022
  • This study was conducted to investigate the effects of mulching materials in extensive green roof system by comparing and analyzing the soil moisture content and growth response of Lychnis cognata according to the types of organic mulching materials. The experimental group consisted of a control group that did not use mulching material (Cont.) and a total of five treatment groups, including cocochip (C.O), woodchip (W.O), straw (S.T), and sawdust (S.A), depending on the mulching material. The soil moisture content according to the type of organic mulching material was high in the order of W.O > S.T > Cont. > C.O > S.A, and there was a significant difference especially in S.A. The plant height showed good growth in the order of S.T > Cont. > C.O > W.O > S.A, and there was no significant difference by mulching materials in other growth items except for plant height. Both the chlorophyll and plant water contents were superior to those of untreated group, so the treatment of organic mulching materials is considered to be effective in maintaining the chlorophyll and plant water contents of Lychnis cognata. In particular, the soil moisture content was affected by the characteristics of the mulching material itself. Based on these results, it is required to use a mulching material suitable for the characteristics of each plant in extensive green roof system and it is considered that this can be overcome through organic mulching when selecting a plant species that is weak to water stress.

Anti-swing and position control of crane using fuzzy controller (퍼지제어기를 이용한 크레인의 진동억제 및 위치제어)

  • Jeong, Seung-Hyun;Park, Jung-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.5
    • /
    • pp.435-442
    • /
    • 1997
  • The roof crane system is used for transporting a variable load to a target position. The goal of crane control system is transporting the load to a goal position as quick as possible without rope oscillation. The crane is generally operated by an expert operator, but recently an automatic control system with high speed and rapid tansportation is required. In this paper, we developed a simple fuzzy controller which has been introduced expert's knowledge base for anti-swing and rapid tranportation to goal position. In particular, we proposed the synthesis reasoning method which synthesizes on the basis of expert knowledge of the angle control input and position control input which are inferenced parallel and simultaneously. And we confirmed that the performance of the developed controller is effective as a result of applying it to crane simulator and also verified whether the proposed synthesis rules have been applied correctly using clustering algorithm from the measured data.

  • PDF

Intelligent Control of Structural Vibration Using Active Mass Damper (능동질량감쇠기를 이용한 구조물 진동의 지능제어)

  • Kim, Dong-Hyawn;Oh, Ju-Won;Lee, In-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.286-290
    • /
    • 2000
  • Optimal neuro-control algorithm is extended to the control of a multi-degree-of-freedom structure. An active mass driver(AMD) system on the top roof is used as an exciter. The control signals are made by a multi-layer perceptron(MLP) which is trained by minimizing a sub-optimal performance index. The performance index is a function of both the output responses and the control signals. Structure having nonlinear hysteretic behavior is also trained and controlled by using proposed control algorithm. In training neuro-controller, emulator neural network is not used. Instead, sensitivity-test data are used. Therefore, only one neural network is used for the control system. Both the time delay effect and the dynamics of hydraulic actuator are included in the simulation. Example shows that optimal neuro-control algorithm can be applicable to the multi-degree of freedom structures.

  • PDF

The Problem and Challenges of Pest Control in Korea (우리나라의 쥐 및 위생해충 방제에 대한 문제점과 개선방향)

  • 전순표
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.129-140
    • /
    • 1992
  • Rats and Cockroaches are the most problematic pests of our living environment, Rats generally fall under three categories, namely, the Norway rats, the roof rats and the mouses, Among these three types, the roof rats are increasing rapidly in number and their habitats are spreading quickly in the city area, where as the Norway rats are decreasing both in number and habitat. There are numerous damages that these pests create in our society, The rat induce damages to computers and other information processing equipments, sometimes cause light-out, and other financial losses and other sanitary problems. The cockroaches, apart from inducing serious sanitary problems, is an insect that creates insectophobia. decently, it has been revealed that cockroaches are also the main carriers of allergic diseases. Among the pesticides employed against rats in Korea, Beta - fluoro acetate(1080) was initially used after the National Liberalization. Later, the Korean government imported anticoagulant rodenticide for its control. This was followed by a brief, unsuccessful utilization of Zinc Phosphide. Since the begin of 1980s, with the advent of pest control companies, first generation anticoagulant rodenticide were developed in Korea and recently followed by a widespread use of pesticide that utilizes second generation anticoagulant material, the "Brodifacoum" . Among insecticides employed against cockroaches, "Fenitrothion" "Dusban" "DDVP" "Diazinon" and others have been used. They were gradually being replaced by the use of synthesised pyrethroid insecticides until recently. Today there is a wide spread use of bait poisons, the "hydramethylnon" Nevertheless, full prevention and control can not be realized with the sole use of the pesticides. In the future, hygine and proofing, combined with affective pest management, must be incorporated in order to bring about more satisfactory and fruitful preventive measures.

  • PDF

New approaches to testing and evaluating the impact capability of coal seam with hard roof and/or floor in coal mines

  • Tan, Y.L.;Liu, X.S.;Shen, B.;Ning, J.G.;Gu, Q.H.
    • Geomechanics and Engineering
    • /
    • v.14 no.4
    • /
    • pp.367-376
    • /
    • 2018
  • Samples composed of coal and rock show different mechanical properties of the pure coal or rock mass. For the same coal seam with different surrounding rocks, the frequency and intensity of rock burst can be significantly different in. First, a method of measuring the strain variation of coal in the coal-rock combined sample was proposed. Second, laboratory tests have been conducted to investigate the influences of rock lithologies, combined forms and coal-rock height ratios on the deformation and failure characteristics of the coal section using this method. Third, a new bursting liability index named combined coal-rock impact energy speed index (CRIES) was proposed. This index considers not only the time effect of energy, but also the influence of surrounding rocks. At last, a new approach considering the influences of roof and/or floor was proposed to evaluate the impact capability of coal seam. Results show that the strength and elastic modulus of coal section increase significantly with the coal-rock height ratio decreasing. In addition, the values of bursting liability indexes of the same coal seam vary greatly when using the new approach. This study not only provides a new approach to measuring the strain of the coal section in coal-rock combined sample, but also improves the evaluation system for evaluating the impact capability of coal.

Intelligent Control of structures under Earthquakes (지진시 구조물의 지능제어 기법)

  • 김동현;이규원;이종헌;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.271-276
    • /
    • 2000
  • Optimal neuro-control algorithm is extended to the control of a multi-degree-of-freedom structure. An active mass driver(AMD) system on the top roof used as a controller. The control signals are made by a multi-layer perceptron(MLP) which is trained by minimizing a sub-optimal performance index. The performance index is a function of both the output responses and the control signals. Structure having nonlinear hysteretic behavior is also trained and controlled by using proposed control algorithm. Bothe the time delay effect and the dynamics of hydraulic actuator are included in the simulation. Example shows that optimal neuro-control algorithm can be applicable to the multi-degree of freedom structures.

  • PDF

Roof Ventilation Structures and Ridge Vent Effect for Single Span Greenhouses of Arch Shape (아치형 단동온실의 지붕환기구조 및 천창효과)

  • Nam, Sang-Woon
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.99-107
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouses of arch shape. Investigation on the roof ventilation structures for those greenhouses was conducted. In small greenhouses with spans of 5 to 8 m, circular or chimney type ridge vents made of plastic were employed. In large greenhouses with spans of 12 to 18 m, even span roll-up ridge vents made of steel pipe were employed. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing ridge vents and having controlled side vents only. Roof ventilation contributed greatly to restraint of temperature rise and maintenance of uniform temperature distribution in greenhouses. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the ridge and side vent. There were no temperature differences according to opening and closing sequence of ventilation window. But for greenhouse temperature control by ventilation, it is desirable to open side vents after ridge vents and to close ridge vents after side vents.

  • PDF