• Title/Summary/Keyword: roll to roll system

Search Result 909, Processing Time 0.026 seconds

Measurement of inconvenience, human errors, and mental workload of simulated nuclear power plant control operations

  • Oh, I.S.;Sim, B.S.;Lee, H.C.;Lee, D.H.
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.47-55
    • /
    • 1996
  • This study developed a comprehensive and easily applicable nuclear reactor control system evaluation method using reactor operators behavioral and mental workload database. A proposed control panel design cycle consists of the 5 steps: (1) finding out inconvenient, erroneous, and mentally stressful factors for the proposed design through evaluative experiments, (2) drafting improved design alternatives considering detective factors found out in the step (1), (3) comparative experiements for the design alternatives, (4) selecting a best design alternative, (5) returning to the step (1) and repeating the design cycle. Reactor operators behavioral and mental workload database collected from evaluative experiments in the step (1) and comparative experiments in the step (3) of the design cycle have a key roll in finding out defective factors and yielding the criteria for selection of the proposed reactor control systems. The behavioral database was designed to include the major informations about reactor operators' control behaviors: beginning time of operations, involved displays, classification of observational behaviors, dehaviors, decisions, involved control devices, classification of control behaviors, communications, emotional status, opinions for man-machine interface, and system event log. The database for mental workload scored from various physiological variables-EEG, EOG, ECG, and respir- ation pattern-was developed to indicate the most stressful situation during reactor control operations and to give hints for defective design factors. An experimental test for the evaluation method applied to the Compact Nuclear Simulator (CNS) installed in Korea Atomic Energy Research Institute (KAERI) suggested that some defective design factors of analog indicators should be improved and that automatization of power control to a target level would give relaxation to the subject operators in stressful situation.

  • PDF

Analysis of demonstration research on solar heat pump system for room and hot water heating in the southern part of South Korea (남부지역의 태양열이용 열펌프식 온수.난방시스템의 실증연구 분석)

  • Sun, Kyung Ho;Kim, Ki Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.198.1-198.1
    • /
    • 2010
  • The goal of this study is to measure and compare the performance of solar heat pump for room and hot water heating. To accomplish the goal, solar heat pump with alumium roll bond type evaporator and indoor heat exchanger(condenser) was built and fully instrumented with thermocouples and pressure transducers etc. The test results showed that the COP(coefficient of performance) of HFC-134a($CF_3CH_2F$) were higher than those of CFC-12($CF_2Cl_2$). One "stratospherically safe" new refrigerant is 1,1,1,2-tetrafluoroethane(HFC-134a), which is thermodynamically similar to CFC-12 and considered to be a potential direct replacement for CFC-12 in air-conditioning and refrigeration applications. The solar heat pump system for room heating was designed to show the best efficiency that the room temperature make $18{\sim}20^{\circ}C$ and $23{\sim}25^{\circ}C$ in the southern part of South Korea during November, December, and January.

  • PDF

Reducing Ship Rolling with a Anti-Rolling Pendulum (안티롤링 진자를 이용한 부유체의 횡동요 저감)

  • Park, Sok-Chu;Yi, Geum-Joo;Park, Kyung-Il
    • Journal of Navigation and Port Research
    • /
    • v.40 no.6
    • /
    • pp.361-368
    • /
    • 2016
  • A ship's rolling motion can make crew and passengers sick and/or apply forces to the structure that cause damage.. Therefore bilge keels are equipped in most ships for anti-rolling. In special cases, anti-rolling tanks (ARTs), fin stabilizers, or gyroscopes can be installed. However, ARTs require a large area to install, and fin stabilizers and gyroscopes are costly to install and expensive to operate. This paper suggests a Anti-rolling pendulum (ARP) to reduce roll motion. ARPs acts like ARTs. However, the ARP has a circular shaped guidance arc instead of the string or wire of a simple pendulum. The device suggested has about 1/ 8 the weight and 1/ 6 the volume of a ART and is more effective. This study derives the nonlinear and linear differential equations of system motion.

A Study on Occupation Classification of Aquatic Disease Inspector in Korean Standard Classification of Occupations(KSCO) (한국표준직업분류에 있어서 수산질병관리사의 직업분류에 관한 연구)

  • Ko, Myung-Shik
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.1
    • /
    • pp.10-21
    • /
    • 2014
  • The aquatic disease inspector is not classified as an occupation in the current Korean Standard Classification of Occupations(KSCO). Therefore, the roll of the aquatic disease inspector in the medical treatment and the prevention against the aquatic organism disease is underestimated. The aquatic disease inspector is in a more disadvantageous position than the pharmacist and the veterinarian. The purpose of this study is to approve the aquatic disease inspector as an occupation in KSCO. The important contents of this study are as follows. In the first place, this study looks around the general requirements of classifying the occupations in KSCO. The aquatic disease inspector satisfies the most general requirements. But, because of the similarities of job between the aquatic disease inspector and the veterinarian, the aquatic disease inspector do not satisfy the requirement for 'the principle of exclusiveness'. In the second place, this study looks around the classification system of KSCO. The classification system of KSCO is consists of multi steps. This study makes the plan for the appropriate occupation classification of the aquatic disease inspector. In the third place, this study looks for the legal methods to classify the aquatic disease inspector as an occupation in KSCO. In order to classify the aquatic disease inspector as an occupation in KSCO, many regulations of the laws about the aquatic disease inspector and the veterinarian are to be amended and the number of the aquatic disease inspectors is to be increased by the innovative measures.

Design and Implementation of a Mobile Web Services for Supporting Dormitory Works (기숙사 업무 지원을 위한 모바일 웹 서비스 설계 및 구현)

  • Kim, Sung Wan;Son, Byeong-Oh;Cho, Yang-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.6
    • /
    • pp.1389-1398
    • /
    • 2013
  • With the rapid increase in supplying and applying of mobile devices major student services in colleges are provided in mobile device-based ones. In this paper we describe a design and implementation of a dormitory works supporting service system based on mobile web to efficiently assist dormitory business and provide student convenient services especially for dormitory type public schools and colleges requiring a strict student management. The proposed system, first, improves the effectiveness of work processing, such as roll call, sleep out handling, in the aspect of business management. Second students satisfaction level is increased as giving them access under Web by providing mobile web environment. We operated the proposed system over a college dormitory living around 250 students for a semester and evaluated its usefulness by conducting a questionnaire survey.

Development of a Control Algorithm for Automatic Ventilation (환기창 자동제어용 제어 알고리즘 개발)

  • 박규식;이기명
    • Journal of Bio-Environment Control
    • /
    • v.6 no.4
    • /
    • pp.242-249
    • /
    • 1997
  • Environmental control operations have been considerably contributed to the reduction of labor cost in both plastic film and glass greenhouses since government supported projects were begun. However, some problems are still remaining on the optimal environmental control and excessive operation due to an inflexible software regulating ventilation gear - reducers. The unadjustable software caused the damage of ventilation system, resulting in heat stresses of crops. This study was performed to develop a ventilation software controlling the vent opening level, opening sequence, based on the wind direction, and control interval according to the difference between ambient and set- up temperatures. The software included a beeper system alarming urgent cases, while a manager was remote from the greenhouse. A compatible hardware with the software was also developed by using a low-cost diffused DSP controller.

  • PDF

Evaluation of Point-Of-Use (POU) Filters Performance in Chemical Mechanical Polishing Slurry Supply System (슬러리 공급 시스템을 이용한 화학적 기계적 연마 공정에서의 POU 필터의 성능 평가)

  • Jang, Sunjae;Kim, Hojoong;Jin, Hongi;Nam, Miyeon;Kulkarni, Atul;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.261-269
    • /
    • 2013
  • The chemical mechanical polishing (CMP) process is widely used in semiconductor manufacturing process for planarization of various materials and structures. Point-of-use (POU) filters are used in most of the CMP processes in order to reduce the unwanted micro-scratches which may result in defects. The performance of the POU filter is depends on type and size of the abrasives used during cleaning process. For this reason, there is a need to evaluate POU filters for their filtration efficiency (FE) with different types of abrasives. In this study, we developed filter test system to evaluate the FE of POU using ceria and silica abrasives (slurry). The POU filter is roll type capsule filter with retention size of 0.2 ${\mu}m$. Two POU filters of different make are evaluated for FE. We observed that both POU filters show similar filtration efficiency for silica and ceria slurry. Results reveal that the ceria slurry and the colloidal silica particle are removed not only by mechanical way but also hydrodynamic and electrostatic interaction way.

Autonomous Formation Flight Tests of Multiple UAVs (다수 무인항공기의 자동 편대비행 시험)

  • Song, Yong-Kyu;Heo, Chang-Hwan;Lee, Sang-Jun;Kim, Jung-Han
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.3
    • /
    • pp.264-273
    • /
    • 2010
  • In this work, autonomous formation flight tests of multiple UAVs are experimentally studied. After a guidance and control system for a UAV is designed and tested, PID formation controller for follower UAV is tested using longitudinal and lateral distance feedback. It is shown that more stable and efficient formation guidance system is obtained by using position and attitude of the leader aircraft, which is exploited to calculate virtual waypoint for follower. In order to improve transient response during turn, part of roll command of the leader is added to the guidance command. Finally, autonomous formation flight test results of 3 UAVs are shown by using the best guidance algorithm suggested.

A Study on Prevention Control Law of Aircraft Departure at High Angle of Attack (고받음각에서 항공기 이탈 방지를 위한 제어법칙에 관한 연구)

  • Kim, Chong-Sup;Hwang, Byung-Moon;Jung, Dae-Hee;Kim, Seung-Jun;Bae, Myung-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.7
    • /
    • pp.85-91
    • /
    • 2005
  • Supersonic jet fighter aircraft must have been guaranteed appropriate for controllability and stability in HAoA(High Angle of Attack) region. Limit value of aircraft enter the deep stall at HAoA is related to problem of aircraft configuration design. But, In order to guarantee the aircraft safety in HAoA, control law is designed using digital Fly-By-Wire flight control system in modern versions of supersonic jet fighter aircraft. Also, In order to recovery if aircraft enter the deep stall or spin, anti-spin control law and MPO(Manual Pitch Override) mode is designed. AoA limiter and MPO is designed in longitudinal axis and HAoA departure prevention logic, roll command limiter, rudder fader and anti-spin logic is designed in lateral-directional axis. In this paper, we introduce the T-50 HAoA flight control law and propose that aircraft stability and adequate of these control law from HAoA flight test.

Characteristics and Quality Control of Precipitable Water Vapor Measured by G-band (183 GHz) Water Vapor Radiometer (G-band (183 GHz) 수증기 라디오미터의 가강수량 특성과 품질 관리)

  • Kim, Min-Seong;Koo, Tae-Young;Kim, Ji-Hyoung;Jung, Sueng-Pil;Kim, Bu-Yo;Kwon, Byung Hyuk;Lee, Kwangjae;Kang, Myeonghun;Yang, Jiwhi;Lee, ChulKyu
    • Journal of the Korean earth science society
    • /
    • v.43 no.2
    • /
    • pp.239-252
    • /
    • 2022
  • Quality control methods for the first G-band vapor radiometer (GVR) mounted on a weather aircraft in Korea were developed using the GVR Precipitable Water Vapor (PWV). The aircraft attitude information (degree of pitch and roll) was applied to quality control to select the shortest vertical path of the GVR beam. In addition, quality control was applied to remove a GVR PWV ≥20 mm. It was found that the difference between the warm load average power and sky load average power converged to near 0 when the GVR PWV increased to 20 mm or higher. This could be due to the high brightness temperature of the substratus and mesoclouds, which was confirmed by the Communication, Ocean and Meteorological Satellite (COMS) data (cloud type, cloud top height, and cloud amount), cloud combination probe (CCP), and precipitation imaging probe (PIP). The GVR PWV before and after the application of quality control on a cloudy day was quantitatively compared with that of a local data assimilation and prediction system (LDAPS). The Root Mean Square Difference (RMSD) decreased from 2.9 to 1.8 mm and the RMSD with Korea Local Analysis and Precipitation System (KLAPS) decreased from 5.4 to 4.3 mm, showing improved accuracy. In addition, the quality control effectiveness of GVR PWV suggested in this study was verified through comparison with the COMS PWV by using the GVR PWV applied with quality control and the dropsonde PWV.