• Title/Summary/Keyword: rocking walls

검색결과 18건 처리시간 0.019초

주기하중을 받는 비보강 조적벽체의 강체회전거동 (Rocking Behavior of Unreinforced Masonry Walls Under Cyclic Load)

  • 엄태성;김진우;김선웅;김재환;한주연;최호
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.49-57
    • /
    • 2023
  • This study investigated the rocking behavior of unreinforced masonry walls and wall piers under cyclic loading. Based on the benchmark tests, the characteristics of load-deformation relations in masonry walls with rocking failure were captured, focusing on observed deformation modes. The rocking strengths of masonry walls (i.e., peak and residual strengths) were evaluated, and the effects of opening configurations on the masonry wall strength were examined. The deformation capacity of the rocking behavior and the hysteresis shape of the load-deformation relations were also identified. Based on the results, modeling approaches for the rocking behavior of masonry walls were discussed.

Effectiveness of rocking walls system in seismic retrofit of vertically irregular RC buildings

  • Tadeh Zirakian;Omid Parvizi;Mojtaba Gorji Azandariani;David Boyajian
    • Steel and Composite Structures
    • /
    • 제52권5호
    • /
    • pp.543-555
    • /
    • 2024
  • This study examines the seismic vulnerability of vertically irregular reinforced concrete (RC) frame buildings, focusing on the effectiveness of retrofitting techniques such as rocking walls (RWs) in mitigating soft story mechanisms. Utilizing a seven-story residential apartment as a prototype in a high-seismicity urban area, this research performs detailed nonlinear simulations to evaluate both regular and irregular structures, both before and after retrofitting. Pushover and nonlinear time history analyses were conducted using OpenSees software, with a suite of nine ground motion records to capture diverse seismic scenarios. The findings indicate that retrofitting with RWs significantly improves seismic performance: for instance, roof displacements at the Collapse Prevention (CP) level decreased by up to 23% in the irregular structure with retrofitting compared to its non-retrofitted counterpart. Additionally, interstory drift ratios were more uniform post-retrofit, with Drift Concentration Factor (DCF) values approaching 1.0 across all performance levels, reflecting reduced variability in seismic response. The global ductility of the retrofitted buildings improved, with displacement ductility ratios increasing by up to 29%. These results underscore the effectiveness of RWs in enhancing global ductility, mitigating soft story failures, and providing a more predictable deformation pattern during seismic events. The study thus provides valuable insights into the robustness and cost-effectiveness of using rocking walls for retrofitting irregular RC buildings.

조적벽체의 전단강도 향상 방안에 관한 연구 (Strengthening of shear resistance of masonry walls)

  • 강성훈;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.193-196
    • /
    • 2008
  • 본 연구에서는 비보강 조적조 건물의 전단강도와 연성능력을 향상시킬 수 있는 철물을 사용하여 보강된 조적벽체의 성능향상 검증을 위한 실험의 기초자료를 제시 하고자 한다. 실험에 사용될 철물은 얇은 육각 기둥들이 패턴형태를 이룬 벌집 모양의 하니컴 스틸재로 세라켐(주)이 일반 구조용 압연강 재인 SS400으로 제작한 것으로서 선행 실험으로 부터 철근콘크리트 보의 전단 강도 및 강성 증가에 효과가 있음이 나타났다. 국내의 경우 비보강 조적조 건물에 대한 내진규정이 마련되어 있지 않기 때문에 미국 내진 보강 지침서인 FEMA 207 및 306 에서 제안하는 4가지 파괴모드(수평줄눈의 전단파괴, Rocking 파괴, 사인장 파괴, Toe 파괴)와 강도식을 사용하여 그 중 사인장 파괴를 제외한 3가지 파괴모드를 형상비를 변수로 유도하여 보강되지 않은 벽체와 1면 및 2면 보강된 벽체를 계획하였고 보강효과를 예측하였다. 강도식으로 부터 보강철물의 효과는 Rocking 및 Toe 파괴에서는 단부 구속력의 증가, 전단 파괴에서는 수평줄눈의 전단강도 증가가 예상되며 각각의 경우 연성증가도 예상된다

  • PDF

강봉 댐퍼와 록킹 거동 (Steel Rod Damper and Rocking Behavior)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.1-9
    • /
    • 2020
  • 본 연구에서는 벽체의 록킹 거동을 고려한 내진보강 기법을 개발하였다. 록킹 거동은 벽체 수직 축을 중심으로 좌우로 회전하는 것으로, 개발 시스템은 변위 큰 부분에 댐퍼 등을 설치하여 에너지를 소산 시키는 방법이다. 댐퍼는 강봉 댐퍼를 사용하였으며, 강봉 지름 및 길이(형상비)를 변수로 선정하였다. 실험결과 댐퍼길이 260mm 경우 우수한 내진 성능을 보유한 것으로 평가되었다.

조적채움벽을 갖는 RC 벽-슬래브 골조의 내진성능 연구 (Investigation of Seismic Performance of RC Wall-Slab Frames with Masonry Infill)

  • 김찬호;이승제;허석재;엄태성
    • 한국지진공학회논문집
    • /
    • 제26권3호
    • /
    • pp.137-147
    • /
    • 2022
  • This study investigated the seismic performance of reinforced concrete (RC) wall-slab frames with masonry infills. Four RC wall-slab frames with or without masonry infill were tested under cyclic loading. The RC frames were composed of in-plane and out-of-plane walls and top and bottom slabs. For masonry infill walls, cement bricks were stacked applying mortar paste only at the bed joints, and, at the top, a gap of 50 mm was intentionally left between the masonry wall and top RC slab. Both sides of the masonry walls were finished by applying ordinary or fiber-reinforced mortars. The tests showed that despite the gap on top of the masonry walls, the strength and stiffness of the infilled frames were significantly increased and were different depending on the direction of loading and the finishing mortars. During repeated loading, the masonry walls underwent horizontal and diagonal cracking and corner crushing/spalling, showing a rocking mode inside the RC wall-slab frame. Interestingly, this rocking mode delayed loss of strength, and as a result, the ductility of the infilled frames increased to the same level as the bare frame. The interaction of masonry infill and adjacent RC walls, depending on the direction of loading, was further investigated based on test observations.

Performance-based framework for soil-structure systems using simplified rocking foundation models

  • Smith-Pardo, J. Paul
    • Structural Engineering and Mechanics
    • /
    • 제40권6호
    • /
    • pp.763-782
    • /
    • 2011
  • Results from nonlinear time-history analyses of wall-frame structural models indicate that the condition of vulnerable foundations -for which uplifting and reaching the bearing capacity of the supporting soil can occur before yielding at the base of the shear walls- may not be necessarily detrimental to the drift response of buildings under strong ground motions. Analyses also show that a soil-foundation system can inherently have deformation capacity well in excess of the demand and thus act as a source of energy dissipation that protects the structural integrity of the shear walls.

콘크리트 회전형 기둥의 비선형 횡방향 거동 및 단면응력 분포 분석 (Nonlinear Lateral Behavior and Cross-Sectional Stress Distribution of Concrete Rocking Columns)

  • 노화성;황웅익;이후석;이종세
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.285-292
    • /
    • 2012
  • 일반적으로 콘크리트 구조물은 보와 기둥이 서로 강결되어 있으며, 이러한 경우 강진에 의해 연결부에서 심각한 손상이 발생할 수 있다. 이를 저감시키면서 내진성능을 향상시키기 위한 다양한 연결 형태가 연구되어지고 있다. 그 한 예로 연결부에서의 회전을 허용하는 연결형식이 있으며 보나 기둥, 그리고 전단벽에 응용되고 있다. 이러한 회전형 구조요소들은 횡방향 거동시 비선형 힘-변위 관계를 나타내는데, 그 원인은 연결부의 회전으로 인한 접촉면의 깊이(contact depth)가 줄어듦과 동시에 요소의 각 단면에서의 응력이 비선형적으로 분포되는 탄성힌지 구간이 존재하기 때문이다. 이 연구에서는 축방향 하중(공칭강도의 5%와 10%)과 경계조건(양단구속 형식, 캔틸레버 형식), 세장비(L/d = 5, 7, 10) 등의 변수를 고려한 유한요소해석을 통해 회전형 기둥의 탄성힌지 구간 또는 길이를 분석하였다. 그 결과 이 세가지 변수는 탄성힌지길이 변화에는 직접적인 영향을 주지 않았으며 다만 접촉면의 깊이에 의해 지배됨을 알 수 있었다. 이 탄성힌지길이는 opening state부터 발생하기 시작하여 rocking point까지(pre-rocking 구간) 증가하였으나 그 이후(post-rocking 구간)에서는 일정한 값을 보였다. 탄성힌지길이에 대한 유한요소해석 결과를 이론적 예측식인 반무한모델(half space model)의 결과와 비교하였다.

A low damage and ductile rocking timber wall with passive energy dissipation devices

  • Loo, Wei Yuen;Quenneville, Pierre;Chouw, Nawawi
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.127-143
    • /
    • 2015
  • In conventional seismic design, structures are assumed to be fixed at the base. To reduce the impact of earthquake loading, while at the same time providing an economically feasible structure, minor damage is tolerated in the form of controlled plastic hinging at predefined locations in the structure. Uplift is traditionally not permitted because of concerns that it would lead to collapse. However, observations of damage to structures that have been through major earthquakes reveal that partial and temporary uplift of structures can be beneficial in many cases. Allowing a structure to move as a rigid body is in fact one way to limit activated seismic forces that could lead to severe inelastic deformations. To further reduce the induced seismic energy, slip-friction connectors could be installed to act both as hold-downs resisting overturning and as contributors to structural damping. This paper reviews recent research on the concept, with a focus on timber shear walls. A novel approach used to achieve the desired sliding threshold in the slip-friction connectors is described. The wall uplifts when this threshold is reached, thereby imparting ductility to the structure. To resist base shear an innovative shear key was developed. Recent research confirms that the proposed system of timber wall, shear key, and slip-friction connectors, are feasible as a ductile and low-damage structural solution. Additional numerical studies explore the interaction between vertical load and slip-friction connector strength, and how this influences both the energy dissipation and self-centring capabilities of the rocking structure.

내진보강된 치장조적벽의 파괴특성과 전단강도 (Shear Strength and Failure Mode of Architectural Masonry Walls)

  • 진희종;한상환;박영미
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.89-92
    • /
    • 2008
  • 본 연구는 조적조로 구성된 치장벽체의 전단거동에 관한 연구이다. 치장조적벽체의 내진보강상 세를 소개하였으며, 본 연구에서 개발한 내진상세를 적용하여 전단거동을 평가하였다. 실험체는 비보 강조적벽(URM) 1개 보강조적벽(RM) 3개로 구성하였으며, 준정적 실험을 수행하였다. 비보강 조적벽은 형상비와 축방향 압축력에 따라 다양한 거동 및 파괴가 일어난다. 그러나 본 연구는 조적구조와는 다른 치장조적조를 대상으로 하였으므로, 전단강도의 주요변수로 작용하는 축방향 압축력은 변수에서 제외 되었다. 실험변수로는 벽체의 보강유무와 형상비로 정하였다. 실험결과 실험체의 거동은 강체회전(Rocking)모드가 지배적으로 나타났으나, 최종파괴는 여러 파괴모드가 복합적으로 나타났다. FEMA273 에서는 면내조적벽의 전단강도식을 제시한다. 강도식은 조적벽의 거동모드에 따라 4가지로 분류되며, 그 거동모드는 강체회전(Rocking), 단부압괴(Toe-Crushing), 수평줄눈미끄러짐(Bed-Joint-Sliding), 사인장(Diagonal-Tension)파괴로 나타내고 있다. FEMA 273에 의해 전단강도를 평가한 결과 치장조적벽의 거동모드는 어느정도 예측 할 수 있었지만, 전단강도는 매우 다르게 나타났다.

  • PDF

Snap back testing of unbonded post-tensioned concrete wall systems

  • Twigden, Kimberley M.;Henry, Richard S.
    • Earthquakes and Structures
    • /
    • 제16권2호
    • /
    • pp.209-219
    • /
    • 2019
  • Unbonded Post-Tensioned (UPT) precast concrete systems have been shown to provide excellent seismic resistance. In order to improve understanding of the dynamic response of UPT systems, a series of snap back tests on four UPT systems was undertaken consisting of one Single Rocking Wall (SRW) and three Precast Wall with End Columns (PreWEC) systems. The snap back tests provided both a static pushover and a nonlinear free vibration response of a system. As expected the SRW exhibited an approximate bi-linear inertia force-drift response during the free vibration decay and the PreWEC walls showed an inertia force-drift response with increased strength and energy dissipation due to the addition of steel O-connectors. All walls exhibited negligible residual drifts regardless of the number of O-connectors or the post-tensioning force. When PreWEC systems of the same strength were compared the inclusion of further energy dissipating O-connectors was found to decrease the measured peak wall acceleration. Both the local and global wall parameters measured at pseudo-static and dynamic loading rates showed similar behaviour, which demonstrates that the dynamic behaviour of UPT walls is well represented by pseudo-static tests. The SRW was found to have Equivalent Viscous Damping (EVD) between 0.9-3.8% and the three PreWEC walls were found to have maximum EVD of between 14.7-25.8%.