• 제목/요약/키워드: rock-soil

검색결과 1,074건 처리시간 0.028초

Application of Depth Resolution and Sensitivity Distribution of Electrical Resistivity Tomography to Modeling Weathered Zones and Land Creeping (전기비저항 깊이분해능 및 감도분포: 풍화층 및 땅밀림 모델에 대한 적용)

  • Kim, Jeong-In;Kim, Ji-Soo;Ahn, Young-Don;Kim, Won-Ki
    • The Journal of Engineering Geology
    • /
    • 제32권1호
    • /
    • pp.157-171
    • /
    • 2022
  • Electrical resistivity tomography (ERT) is a traditional and representative geophysical method for determining the resistivity distributions of surrounding soil and rock volumes. Depth resolution profiles and sensitivity distribution sections of the resistivities with respect to various electrode configurations are calculated and investigated using numerical model data. Shallow vertical resolution decreases in the order of Wenner, Schlumberger, and dipole-dipole arrays. A high investigable depth in homogeneous medium is calculated to be 0.11-0.19 times the active electrode spacing, but is counterbalanced by a low vertical resolution. For the application of ERT depth resolution profiles and sensitivity distributions, we provide subsurface structure models for two types of land-creping failure (planar and curved), subvertical fracture, and weathered layer over felsic and mafic igneous rocks. The dipole-dipole configuration appears to be most effective for mapping land-creeping failure planes (especially for curved planes), whereas the Wenner array gives the best resolution of soil horizons and shallow structures in the weathered zone.

Analysis and Comparison of Physicochemical Characteristics of First-Grade Soils from Ecological and Nature Map -Focused on Igneous Rocks Area- (생태·자연도 1등급 토양의 물리화학적 특성에 대한 분석 및 비교 -화성암 지역을 중심으로-)

  • So-Jin Lee;Chang-Oh Choo;Gyo-Cheol Jeong;Jong-Tae, Kim
    • The Journal of Engineering Geology
    • /
    • 제33권1호
    • /
    • pp.61-68
    • /
    • 2023
  • This study analyzed and compared the physicochemical characteristics of topsoil and subsoil of Grade 1 soil from an igneous rock area on the ecological and nature map. The water content and pH of the collected soil samples were measured, and X-ray fluorescence and X-ray diffraction analyses were performed. The results showed that the water content of the topsoil was higher than that of the subsoil, and its pH was more acidic than that of the subsoil. According to the X-ray fluorescence analysis results, sample I9 was closest to kaolinite, while sample I7 was most distant from kaolinite. All other samples were located between samples I7 and I9. The X-ray diffraction analysis showed that the average content of clay minerals was higher in the topsoil than in the subsoil. The most notable clay minerals produced included illite, vermiculite, kaolinite, chlorite, and gibbsite. The results of this study will be used as a basic data for topsoil restoration to convert subsoil into topsoil.

Evaluation of Permeability on Construction Material in CFRD Bedding Zone (CFRD Bedding Zone의 축조재료에 대한 투수성 평가)

  • Han, Sang-Hyun;Yea, Geu-Guwen
    • The Journal of Engineering Geology
    • /
    • 제19권4호
    • /
    • pp.493-499
    • /
    • 2009
  • Recently, the construction of Concrete Faced Rockfill Dam (CFRD) is increasing because rock material resources are plenty in Korea. Bedding zone in the CFRD is necessary enough bearing capacity to support the concrete face slab uniformly and enough impermeability to prevent the loss of fine soils in case of leakage from the concrete slab face. Therefore, cut-off the water leakage in bedding zone securely is the key factor influencing the safety of CFRD. Tested materials satisfied with the specification of particle size distribution at the Bedding Zone area are chosen for conducting permeability tests, which are done to evaluate the property of cut off the materials. Based on the test results, the effects of cut off the materials are investigated by considering the coefficient of permeability, the soil particle distribution, and the dry unit weight. Especially, the relationships between coefficient of permeability with effective size(D10), dry unit weight, and weight passing percent the No.4 sieve are suggested, and also the variation of coefficient of permeability with time are proposed.

Finite Element Analysis of Underground Electrical Power Cable Structures Considering the Effects of Construction Sequence (시공단계별 영향을 고려한 터널 전력구의 유한요소해석)

  • Kim, Sun-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • 제26권2호
    • /
    • pp.147-155
    • /
    • 2013
  • In this paper structural analysis of underground electrical power cable structures which is excavated below the surface of the earth in the downtown area is carried out considering the effect of construction sequence. There are many various life-line facilities below the surface of the earth in the downtown area. MPDAP was used for finite element analysis of underground electrical power cable structures. Three typical sections are simulated by finite element models. Unbalanced equilibrium problems may be occurred when conventional finite element procedures were used for simulation of tunnel excavation. Therefore equilibrium perturbation concept was applied to solve these problems. The effects of time-dependent deformations in advancing tunnel excavation are considered in the stages of construction sequences as using the load distribution factor. It is shown that values of maximum displacement of both soil and rock surrounding underground electrical power cable structures obtained by our numerical studies are less than allowable values.

Seismic assessment of transfer plate high rise buildings

  • Su, R.K.L.;Chandler, A.M.;Li, J.H.;Lam, N.T.K.
    • Structural Engineering and Mechanics
    • /
    • 제14권3호
    • /
    • pp.287-306
    • /
    • 2002
  • The assessment of structural performance of transfer structures under potential seismic actions is presented. Various seismic assessment methodologies are used, with particular emphasis on the accurate modelling of the higher mode effects and the potential development of a soft storey effect in the mega-columns below the transfer plate (TP) level. Those methods include response spectrum analysis (RSA), manual calculation, pushover analysis (POA) and equivalent static load analysis (ESA). The capabilities and limitations of each method are highlighted. The paper aims, firstly, to determine the appropriate seismic assessment methodology for transfer structures using these different approaches, all of which can be undertaken with the resources generally available in a design office. Secondly, the paper highlights and discusses factors influencing the response behaviour of transfer structures, and finally provides a general indication of their seismic vulnerability. The representative Hong Kong building considered in this paper utilises a structural system with coupled shear walls and moment resisting portal-frames, above and below the TP, respectively. By adopting the wind load profile stipulated in the Code of Practice on Wind Effects: Hong Kong-1983, all the structural members are sized and detailed according to the British Standards BS8110 and the current local practices. The seismic displacement demand for the structure, when built on either rock or deep soil sites, was determined in a companion paper. The lateral load-displacement characteristic of the building, determined herein from manual calculation, has indicated that the poor ductility (brittle nature) of the mega-columns, due mainly to the high level of axial pre-compression as found from the analysis, cannot be effectively alleviated solely by increasing the quantity of confinement stirrups. The interstorey drift demands at lower and upper zones caused by seismic actions are found to be substantially higher than those arising from wind loads. The mega-columns supporting the TP and the coupling beams at higher zones are identified to be the most vulnerable components under seismic actions.

Effect of Applied Voltage on the Reliability of Coating Flaw Detection of Pipe with Different Buried Depths

  • Lim, B.T.;Kim, M.G.;Kim, K.T.;Chang, H.Y.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제18권6호
    • /
    • pp.277-284
    • /
    • 2019
  • External corrosion control of buried pipe can be achieved by the combination of barrier coating and cathodic protection. Coating damage and deterioration can be induced by many reasons; damage during handling and laying, enhanced failure at low temperatures, failure during commissioning and operation, disbanding due to inadequate surface cleaning, rock penetration during installation and service etc. This work focused on the effect of survey conditions on the reliability of coating flaw detection of buried pipes. The effects of applied voltage and anode location on the detection reliability of coating flaw of buried pipe in soil with the resistivity of ca. 25.8 kΩ·cm were discussed. Higher applied voltage increased the detection reliability, regardless of buried depth, but deeper burial depth reduced the reliability. The location of the anode has influenced on the detection reliability. This behaviour may be induced by the variation of current distribution by the applied voltage and buried depth. From the relationship between the applied voltage and reliability, the needed detection potential to get a desire detection reliability can be calculated to get 100% detection reliability using the derived equation.

Resistance to Root Penetration of Root Barrier for Green Roof System (옥상녹화용 방근층 구성재료의 방근성능에 관한 실험적 연구)

  • Kim, Hyun-Soo;Jang, Dae-Hee;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • 제8권6호
    • /
    • pp.123-129
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plant: and soils suitable for weather and natural features of Korea. For testing Plants, Plioblastus pygmaed Mitford A and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of roe barrier materials have penetrated roots. Even though two types of them have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe. USA or Japan.

Effect of tack of Fusion Defects on Short-Term Performance of Polyethylene Electrofusion Joints (폴리에틸렌 배관 전기융착부 단기성능 평가를 위한 융합물량 영향 평가)

  • Kil, Seong-Hee;Kwon, Jeong-Rock;Jo, Ji-Hwan
    • Journal of Energy Engineering
    • /
    • 제14권2호
    • /
    • pp.153-158
    • /
    • 2005
  • In order to investigate the short-term performance of polyethylene electrofusion joints, the mechanical tests and stress analysis have been conducted to the artificially defected weld joints. The defects of lack of fusion with a square-type were fabricated with 10, 20, 30, 40, 50, 60$\%$ size of the width of heat-ing wire zone, respectively. In this defect sires range, both tensile and bending test results showed the dependence of defect size to the electrofusion joints performance, but both sustained pressure and crush test results didn't. The numerical stress analysis results including the soil and internal pressures, tensile and bend-ing stresses clearly showed the dependence of fusion defect size. Based on both mechanical test and stress analysis results, the maximum acceptable defect size in polyethylene electrofusion joints is discussed.

Anaysis of Fe in Seepage Water and Precipitates around a Hydrothermal Alteration Zone

  • Yun, Hyun-Seok;Moon, Seong-Woo;Lee, Jin-Kook;Jeong, Gyo-Cheol;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • 제27권3호
    • /
    • pp.345-351
    • /
    • 2017
  • Acid drainage in civil engineering structures such as tunnels may lead to the deposition of precipitates that clog drainage channels and pipework. In evaluating acid drainage, the Fe content of water and precipitates, indicated by reddish brown coloration of rock surfaces, rivers, and soils, may be an important factor. In this study, acid drainage was evaluated by analyzing the Fe content of reddish brown seepage water that occurred in part of a tunnel. Geological investigations around the tunnel revealed a hydrothermal alteration zone cutting the bedrock, and cropping out in the upper parts of the tunnel. Analysis of drillcore revealed many fracture zones and veins. Inductively coupled plasma spectrophotometric analyses of water, precipitates, and soil samples, collected in the seepage water zone and around the tunnel, were conducted to evaluate acid drainage. The Fe content of seepage water in the tunnel was 0.030-0.333 mg/kg, which is 2-22 times higher than in local groundwater. The Fe content of precipitates in the tunnel was 165,403-301,051 mg/kg, similar to the 206,167-422,964 mg/kg content of drillcore from the hydrothermal alteration zone located above the tunnel. It is concluded that the seepage water is derived from Fe-containing acid drainage flowing in perforated tunnel drainpipes along the fracture zones and veins around the hydrothermal alteration zone.

Variability of Pb, Mn, Al and Na Concentrations is Snow Deposited from Winter to Early Summer 1998 in Livingston lsland, Antarctic Peninsula

  • Sungmin Hong;Lee, Gangwoong;Velde, Katja-Van de;Claude F. Boutron
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제16권E2호
    • /
    • pp.85-96
    • /
    • 2000
  • The concentrations of Pb, Mn, Al and Na were measured from a total of 26 snow samples collected from a 1.5-m deep snow pit in Livingston Island, South Shetland Islands, at the northern tip of the Antarctic Peninsula. Ore sampling location is great concern, because of its proximity to the southern extremity of south America, a candidate for the source regions of pollutant aerosols entering Antarctica. The mean concentrations of Pb and Mn were found to be 4.97 pg g(sup)-1 and 20.6 pgg(sup)-1, respectively. These concentrations levels are similar to those reported for recent snow at other Antarctic sites with pronounced spring maxima for both metals. Contributions form natural sources are estimated to be minor (∼16%) for Pb. For Mn, on the other hand, contribution from rock and soil dusts is found to be very important. Excess Pb over Pb from natural sources is likely to be anthropogenic, especially from South Americal. Our results show that yearly Pb fallout flux is much greater in Antarctic coastal areas than at other Antarctic locations far from the coast , indicating that the transport and deposition patterns of pollutant aerosols are not simple is Antarctica. It is also suggested that the recycling of anthropogenic Pb in seawater to the atmosphere could significantly contribute to the Pb fallout flux in the Antarctic coastal regions.

  • PDF