• Title/Summary/Keyword: rock-soil

Search Result 1,074, Processing Time 0.035 seconds

Consolidation deformation of Baghmisheh marls of Tabriz, Iran

  • Jalali-Milani, Shahrokh;Asghari-Kaljahi, Ebrahim;Barzegari, Ghodrat;Hajialilue-Bonab, Masoud
    • Geomechanics and Engineering
    • /
    • v.12 no.4
    • /
    • pp.561-577
    • /
    • 2017
  • Vast parts of the east of Tabriz city have been covered by Baghmisheh formation marls. These marls can be classified into three types based on their color as identified in yellow, green, and gray marls. Many high-rise buildings and other projects were founded and now is constructing on these marls. Baghmisheh formation marls are classified as stiff soil to very weak rock, therefore they undergo considerable consolidation settlement under foundation loads. This study presents the physical properties and consolidation behavior of these marls. According to the XRD tests, major clay minerals of marls are Illite, Kaolinite, Montmorillonite and Chloride. Uniaxial compressive strength are 100-250, 300-480 and 500-560 kPa for yellow, green and gray marls, respectively. Consolidation and creep behavior of Baghmisheh marls investigated by using of one dimensional consolidation apparatus under stress level up to 5 MPa. The results indicate that yellow marls have high compressibility, settlement and deformation modules. Green marls have an intermediate compressibility and settlement and while gray marls have low compressibility and settlement and from the foundation point of view have high stability. According to the creep test results, all types of marls have not been entered to progressive creep phase up to pressure 5 MPa.

A study on ground surface settlement due to groundwater drawdown during tunnelling (터널 굴착시 지하수 저하로 인한 지반침하에 관한 연구)

  • Yoo, Chung-Sik;Kim, Sun-Bin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.4
    • /
    • pp.361-375
    • /
    • 2007
  • This paper presents the results of investigation on tunnelling-induced ground surface settlement characteristics in water bearing ground using finite element (FE) stress-pore pressure coupled analysis. Fundamental interaction mechanism of ground and groundwater lowering was first examined and a number of influencing factors on the results of the coupled FE analysis were identified. A parametric study was then conducted on the influencing factors such as rock type, thickness of soil layer, permeability of shotcrete lining, among others. The results indicate that the tunneling-induced groundwater drawdown results in a deeper and wider settlement trough than without groundwater drawdown, and that the Error function approach does not yield satisfactory result in predicting a settlement profile. The results of analysis are summarized so that the relationship between the settlement and the influencing factors can be identified.

  • PDF

Hybrid thermal seasonal storage and solar assisted geothermal heat pump systems for greenhouses

  • Ataei, Abtin;Hemmatabady, Hoofar;Nobakht, Seyed Yahya
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.87-106
    • /
    • 2016
  • In this research, optimum design of the combined solar collector, geothermal heat pump and thermal seasonal storage system for heating and cooling a sample greenhouse is studied. In order to optimize the system from technical point of view some new control strategies and functions resulting from important TRNSYS output diagrams are presented. Temperatures of ground, rock bed storage, outlet ground heat exchanger fluid and entering fluid to the evaporator specify our strategies. Optimal heat storage is done with maximum efficiency and minimum loss. Mean seasonal heating and cooling COPs of 4.92 and 7.14 are achieved in series mode as there is no need to start the heat pump sometimes. Furthermore, optimal parallel operation of the storage and the heat pump is studied by applying the same control strategies. Although the aforementioned system has higher mean seasonal heating and cooling COPs (4.96 and 7.18 respectively) and lower initial cost, it requires higher amounts of auxiliary energy either. Soil temperature around ground heat exchanger will also increase up to $1.5^{\circ}C$ after 2 years of operation as a result of seasonal storage. At the end, the optimum combined system is chosen by trade-off between technical and economic issues.

Investigation and Repair Methods for the Excavated Mountain Area damaged by Rainfall : At the Sunghak Campus, Dong-A University (호우로 인한 절개산지의 피해 조사 및 대책공법 -동아대 승학 캠퍼스를 중심으로-)

  • 정성교;김종대
    • Geotechnical Engineering
    • /
    • v.7 no.2
    • /
    • pp.27-40
    • /
    • 1991
  • The Sunghak Campus, Dong-A University, which located at the excavated area of mountain, has been constructed year by year for about 10 years since 1978. The buildings, steep slopes, road and so on in the Campus area were damaged by heavy rainfall more than 200mm 1 day on August, 1989. The methods used for the investigation and repair methods of the damage are the preliminary investigation, the present condition survey, 50 by 50m grid survey, compasstraverse for locating outcrops, geopysical exploration, geologic survey, boring and laboratory soil testing. Based on the results of investigations, the causes of the failures have been evaluated, and the repair methods have been set up as horizontal drains, removal of the dangerous rock, retaining wall with subsurface drains, the elimination of colluvium and slope stabilization by use of precast concrete grids and so on.

  • PDF

A Case Study on Occurrence of Landslide by Heavy Rainfall in Hongcheon Area in 2006 (2006년 집중호우에 의한 홍천지역의 산사태 발생 사례 연구)

  • Kim,, Ho-Jin;Im, Oh-Bin;Yoo, Nam-Jae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.877-882
    • /
    • 2010
  • This paper is a result of investigating causes and main characteristics of landslides, occurred at Hongcheon area in Gangwondo during July in 2006, by collecting relevant data and visiting site. The main cause of landslides in this area has been found to be saturation of the ground wetted by a series of precipitations during 10~13 July and the heavy rainfall during 15 July. The pattern of the landslides could be classified as translational failure, occurred at the boundary between the relatively thin weathered residual soil and the mother rock. By analyzing a number of failed slopes based on site visit and reviewing collected data, typical widths of failed slopes are in the range of 10~20m (minimum: 5m, maximum: 70m). Lengths of landslide area are in the wide range of 10~450m. Most of area are less than 20m in width and 100m in length so that their shapes are long and narrow, frequently observed in Korea, and their areas are relatively small size of around $1000m^2$. The inclinations of the failed slopes are in the range of $10{\sim}60^{\circ}$ while the most probable slope angle is about $20{\sim}25^{\circ}$.

  • PDF

Absorption Characteristics of Perforated Environment Friendly Sound Absorbing Board using Hwangto (황토를 이용한 친환경 유공 흡음보드의 흡음특성)

  • Kim, Sun-Woo;Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.3-8
    • /
    • 2011
  • Sound absorbing materials used for lightweight panels and interior material are mainly made of fibroid material such as glass wool or rock wool. However these fiber type sound absorbing materials have some problems such that sound absorption could be decreased as time goes by because of durability. In addition, dust scattering from fiber type material can cause another problem in health. In this point of view, this study aims to develop environment friendly sound absorbing material using Hwangto(so called loess or yellow soil), a traditional housing material. Hwangto is natural housing material in Korea and generally known for improving indoor air quality. Hwangto panel is made to construct on the floor, wall and ceiling, and expected that there is not enough absorption. Present study tried to develop environment friendly sound absorbing material that has high sound absorption performance with good environment performance in terms of air quality. Pore rate was designed to maximize the absorption in the specific frequency bands, and two kinds of backing space were applied in order to see the effect of backing space. As a result peak frequency that has maximum absorption is going high as the pore rate is increased. The backing space provides more absorption and makes the peak frequency down to low.

접합요소를 이용한 복합기초지반의 변형해석

  • Park, Byeong-Gi;Jeong, Jin-Seop;Lee, Mun-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1987.06a
    • /
    • pp.51-80
    • /
    • 1987
  • In this studys a numerical analysis on the defomation of foundation layer was carried out by indroducing joint element. The method using the joust element between adj assent different materials has been originally developed for rock behavior(Goodman, et al. 1968) . The application of this method to the interface between the footing and soil layer proved satisfactory(Ghaboussi p et at. 1973). Authors tried to obtain the deformation of rrcompound foundation layerg", which vertically or horizontally or both consists of the natural(or intact) soft clay layer and the layer improved artificially in order to get high stiff-fness with replacement or chemical treatment to reduce the excessively detrimental settlemellt or lateral displacement in case of banking or building the civil structure on the soft layer. The joint conditions were classified into three categories : contacts sliding and separation. By coupling "JOINT" as a subroutine into multi-purpose code for the finite element method of the foundatlion daveloped by authors on the assumption that shearing and normal displacement can not be coupledl which terms pinon-dilatant" and by selecting modified Cam-clay modeIP the deformation analysis was performmed. The results using joint element were compared with those secured without introduction of joint element Nain results analized are as follows : 1. For the prediction of settlement and lateral desplacement, the result due to joint element was evaluated larger, which was regarded safe. 2. For the determination of ultimate bearing capacetyi the value using joint element appeared smaller by 20%, which was also safe.

  • PDF

Development and Installation of Large-scale Geotechnical Testing Facilities (대형 지반시험장비의 개발 및 구축)

  • Seo, Min-Woo;Ha, Ik-Soo;Kim, Yong-Seong;Park, Dong-Soon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1233-1240
    • /
    • 2005
  • As the geotechnical technologies have grown, the size of civil structures has become bigger than before, thereby requiring large-scale geotechnical testing equipments which can evaluate the mechanical behavior of large size testing materials such as gravel, crushed rock and so on. These kind of large testing equipments are usually used to evaluate the mechanical characteristics of large size material which are applied in the large infra structures like dam, seashore structure, coastal landfill, soil-structure interaction and seismic response of large-scale structure. In this research, state-of-the-art information in the field of geotechnical engineering was collected and summarized for such large-scale experimental equipments as large-scale geo-centrifuge, large-scale triaxial testing machine, large-scale direct shear testing apparatus and large-scale oedometer.

  • PDF

GIS-based Slope Damage Assessment of Highways During Heavy Rainfalls (집중호우시 GIS를 이용한 고속도로 사면붕괴 영향평가)

  • Jeon, Sang-Soo;Yun, Hong-Sik;Lee, Dong-Ha;Kim, Doo-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.191-198
    • /
    • 2005
  • Slope failures during heavy rainfall have resulted in death of life and economic loss. In recent years, the research on slope damage assessment using Geographical Information System(GIS) has been actively carried out by researchers of several goverment organizations and schools. The researchers in Highway and Transportation Technology Institute (HTTI) of Korea Highway Corporation has developed the GIS database(DB), including highway, rainfalls, soil or rock geometry, types of damage, etc. and have been working on the damage assessment of highway slopes. The DB has been established and summarized in two different ways, such as highway routes and administrative districts. Grid of rainfall intensity generated by maximum rainfalls of each administrative district has been devloped. It shows good correlation of slope damage with heavy rainfalls. Most of damaged slopes were found in the amount of 100 mm to 300 mm rainfalls.

  • PDF

A strategy to enhance the efficiency of land seismic reflection method via controlling seismic energy radiation pattern. (지면 탄성파 반사법의 효율성 향상을 위한 탄성파 발생원 에너지 방사형 변조기법)

  • Kim, Jung-Yul;Kim, Yoo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.807-814
    • /
    • 2004
  • Land seismic reflection survey has been increasingly demanded in various civil engineering works because of its own ability to delineate layers, water table, to detect cavities or fracture zones, to estimate seismic velocities of each layer. However, our shallow subsurface structures are very complex. The relatively thin layer(mostly soil) to the wavelength directly followed by a basic rock with high impedance used to generate complicated surface waves, kind of channel waves with high amplitude that is dominate in entire seismograms and hence the useful reflection events will be almost hopelessly immersed in the undesired surface waves. Thus, it would seem that the use of traditional seismic survey could not be likely to provide in itself a satisfactory information about our exploration targets. This paper hence introduces an efficient measuring strategy illustrating a properly controlled arrangement of the vertical single force sources commonly used, yielding a very sharply elongated form of P-energy with a minimum of S radiation energy, what we call, P-beam source. Abundant experiments of physical modeling showed that in that way the surface waves could be enormously reduced and the reflection events would be additive and thus reinforced. Examples of field data are also illustrated. The contribution of P-beam source will be great in civil engineering area as well as in general geological exploration area.

  • PDF