• 제목/요약/키워드: robotic surgery

검색결과 146건 처리시간 0.026초

MRI 영상 유도 수술 로봇을 위한 개선된 군집 분석 방법을 이용한 뇌종양 영역 검출 개발 (Development of Brain Tumor Detection using Improved Clustering Method on MRI-compatible Robotic Assisted Surgery)

  • 김대관;차경래;승성민;정세미;최종균;노지형;박충환;송태하
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권3호
    • /
    • pp.105-115
    • /
    • 2019
  • Brain tumor surgery may be difficult, but it is also incredibly important. The technological improvements for traditional brain tumor surgeries have always been a focus to improve the precision of surgery and release the potential of the technology in this important area of the body. The need for precision during brain tumor surgery has led to an increase in Robotic-assisted surgeries (RAS). One of the challenges to the widespread acceptance of RAS in the neurosurgery is to recognize invisible tumor accurately. Therefore, it is important to detect brain tumor size and location because surgeon tries to remove as much tumor as possible. In this paper, we proposed brain tumor detection procedures for MRI (Magnetic Resonance Imaging) system. A method of automatic brain tumor detection is needed to accurately target the location of the lesion during brain tumor surgery and to report the location and size of the lesion. In the qualitative assessment, the proposed method showed better results than those obtained with other brain tumor detection methods. Comparisons among all assessment criteria indicated that the proposed method was significantly superior to the threshold method with respect to all assessment criteria. The proposed method was effective for detecting brain tumor.

Recent advances in minimally invasive surgery for gynecologic indications

  • Koo, Yu-Jin
    • Journal of Yeungnam Medical Science
    • /
    • 제35권2호
    • /
    • pp.150-155
    • /
    • 2018
  • Recently, an increasing interest in less invasive surgery has led to the advent of laparoendoscopic single-site surgery (LESS) and natural orifice transluminal endoscopic surgery (NOTES). LESS and NOTES could be technically challenging, but available literature has demonstrated the feasibility and safety of LESS for benign gynecologic diseases. However, the evidence is not strong enough to recommend the use of LESS over that of conventional multiport laparoscopic surgery (MLS). As per the results of the most recently published meta-analysis, the majority of surgical outcomes are equivalent between LESS and MLS, except for the longer operative time in LESS for both adnexal surgery and hysterectomy. Although an increasing number of studies have reported on robotic LESS, NOTES, and LESS for gynecologic malignancy, definite conclusions have not been drawn owing to the lack of sufficient information.

An Image-Guided Robotic Surgery System for Spinal Fusion

  • Chung Goo Bong;Kim Sungmin;Lee Soo Gang;Yi Byung-Ju;Kim Wheekuk;Oh Se Min;Kim Young Soo;So Byung Rok;Park Jong Il;Oh Seong Hoon
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권1호
    • /
    • pp.30-41
    • /
    • 2006
  • The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods for spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Some experiments employing the developed robotic surgery system are conducted. The experimental results confirm that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to respiration.

영상 지원 척추 융합 수술 로봇 시스템의 개발 (Development of An Image-Guided Robotic Surgery System for Spinal Fusion)

  • 정구봉;이수강;김성민;오세민;이병주;김영수;박종일;오성훈;김희국
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.144-148
    • /
    • 2005
  • The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods fer spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images and intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Several experiments employing the developed robotic surgery system are conducted. The experimental results confirmed that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to his/her respiration.

  • PDF

Minimally Invasive Trans-Mitral Septal Myectomy to Treat Hypertrophic Obstructive Cardiomyopathy

  • Kim, Hong Rae;Yoo, Jae Suk;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • 제48권6호
    • /
    • pp.419-421
    • /
    • 2015
  • A 43-year-old man with symptomatic hypertrophic obstructive cardiomyopathy (HOCM) was admitted to our hospital with aggravated exertional dyspnea and successfully treated with robotic transmitral septal myectomy. Minimally invasive transmitral septal myectomy may be a feasible surgical option for the treatment of HOCM in selected cases as an alternative to transaortic myectomy.

A Single-Center Experience of Robotic-Assisted Spine Surgery in Korea : Analysis of Screw Accuracy, Potential Risk Factor of Screw Malposition and Learning Curve

  • Bu Kwang Oh;Dong Wuk Son;Jun Seok Lee;Su Hun Lee;Young Ha Kim;Soon Ki Sung;Sang Weon Lee;Geun Sung Song;Seong Yi
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권1호
    • /
    • pp.60-72
    • /
    • 2024
  • Objective : Recently, robotic-assisted spine surgery (RASS) has been considered a minimally invasive and relatively accurate method. In total, 495 robotic-assisted pedicle screw fixation (RAPSF) procedures were attempted on 100 patients during a 14-month period. The current study aimed to analyze the accuracy, potential risk factors, and learning curve of RAPSF. Methods : This retrospective study evaluated the position of RAPSF using the Gertzbein and Robbins scale (GRS). The accuracy was analyzed using the ratio of the clinically acceptable group (GRS grades A and B), the dissatisfying group (GRS grades C, D, and E), and the Surgical Evaluation Assistant program. The RAPSF was divided into the no-breached group (GRS grade A) and breached group (GRS grades B, C, D, and E), and the potential risk factors of RAPSF were evaluated. The learning curve was analyzed by changes in robot-used time per screw and the occurrence tendency of breached and failed screws according to case accumulation. Results : The clinically acceptable group in RAPSF was 98.12%. In the analysis using the Surgical Evaluation Assistant program, the tip offset was 2.37±1.89 mm, the tail offset was 3.09±1.90 mm, and the angular offset was 3.72°±2.72°. In the analysis of potential risk factors, the difference in screw fixation level (p=0.009) and segmental distance between the tracker and the instrumented level (p=0.001) between the no-breached and breached group were statistically significant, but not for the other factors. The mean difference between the no-breach and breach groups was statistically significant in terms of pedicle width (p<0.001) and tail offset (p=0.042). In the learning curve analysis, the occurrence of breached and failed screws and the robot-used time per screw screws showed a significant decreasing trend. Conclusion : In the current study, RAPSF was highly accurate and the specific potential risk factors were not identified. However, pedicle width was presumed to be related to breached screw. Meanwhile, the robot-used time per screw and the incidence of breached and failed screws decreased with the learning curve.

Transoral Robotic Surgery for Tonsillar Cancer

  • Park, Young-Min;Lee, Won-Sang;Kim, Won-Shik;Chung, Sa-Myung;Kim, Se-Heon
    • 대한두경부종양학회:학술대회논문집
    • /
    • 대한두경부종양학회 2009년도 춘계학술대회 논문집
    • /
    • pp.75-75
    • /
    • 2009
  • PDF

경구강 레이저 및 로봇 수술 (Transoral Laser and Robotic Surgery)

  • 노종렬;유창환
    • 대한기관식도과학회지
    • /
    • 제17권1호
    • /
    • pp.29-34
    • /
    • 2011
  • Traditionally, the main strategy of treatment of the head and neck cancer was en bloc resection including adjacent normal tissues through wide incision. However, the procedures may leave severe functional deficit such as swallowing difficulty, aspiration, and wide neck scar. Therefore, many attempts have been made up to minimize these morbidities. Of them, the minimal invasive approach such as transoral laser microsurgery (TLM) and transoral robot surgery (TORS) have been spolighted as a sensible strategy for organ preservation of the head and neck cancer patients. Results of TLM are equivalent to those obtained by conventional surgery, with considerably less morbidity, less hospital time and better postoperative function. Oncologic results of TLM are equivalent to conventional surgery. TORS are safe, feasible, and promising but oncologic safety is not yet verified. This article covers to current application of TLM and TORS, their advantages and limitations, and future direction.

  • PDF

A case of laparoscopic excision of choledochal cyst, hepaticojejunostomy, and Roux-en-Y anastomosis using Artisential®

  • Younghoon Shim;Chang Moo Kang
    • 한국간담췌외과학회지
    • /
    • 제28권2호
    • /
    • pp.266-269
    • /
    • 2024
  • Choledochal cyst is a condition involving an abnormal dilation of the bile ducts, which can lead to various symptoms and comorbidities, including cancer. The treatment of choice for choledochal cyst is surgical correction including choledochal cyst excision and Roux-en-y hepaticoenterostomy. Minimal invasive methods like laparoscopic methods or robotic methods are used for surgical correction of choledochal cysts; however, it is still controversial which method is superior. A Korean company, LIVESMED, developed Artisential®, a laparoscopic surgical instrument that can overcome the drawbacks of laparoscopic methods. This article presents a case of the first Artisential®-performed surgical excision of a choledochal cyst and hepaticojejunostomy.

Intraoperative Nerve Monitoring during Minimally Invasive Esophagectomy and 3-Field Lymphadenectomy: Safety, Efficacy, and Feasibility

  • Srinivas Kodaganur Gopinath;Sabita Jiwnani;Parthiban Valiyuthan;Swapnil Parab;Devayani Niyogi;Virendrakumar Tiwari;C. S. Pramesh
    • Journal of Chest Surgery
    • /
    • 제56권5호
    • /
    • pp.336-345
    • /
    • 2023
  • Background: The objective of this study was to demonstrate the safety, efficacy, and feasibility of intraoperative monitoring of the recurrent laryngeal nerves during thoracoscopic and robotic 3-field esophagectomy. Methods: This retrospective analysis details our initial experience using intraoperative nerve monitoring (IONM) during minimally invasive 3-field esophagectomy. Data were obtained from a prospectively maintained database and electronic medical records. The study included all patients who underwent minimally invasive (video-assisted thoracic surgery/robotic) transthoracic esophagectomy with neck anastomosis. The patients were divided into those who underwent IONM during the study period and a historical cohort who underwent 3-field esophagectomy without IONM at the same institution. Appropriate statistical tests were used to compare the 2 groups. Results: Twenty-four patients underwent nerve monitoring during minimally invasive 3-field esophagectomy. Of these, 15 patients underwent thoraco-laparoscopic operation, while 9 received a robot-assisted procedure. In the immediate postoperative period, 8 of 24 patients (33.3%) experienced vocal cord paralysis. Relative to a historical cohort from the same institution, who were treated with surgery without nerve monitoring in the preceding 5 years, a 26% reduction was observed in the nerve paralysis rate (p=0.08). On follow-up, 6 of the 8 patients with vocal cord paralysis reported a return to normal vocal function. Additionally, patients who underwent IONM exhibited a higher nodal yield and a decreased frequency of tracheostomy and bronchoscopy. Conclusion: The use of IONM during minimally invasive 3-field esophagectomy is safe and feasible. This technique has the potential to decrease the incidence of recurrent nerve palsy and increase nodal yield.