• Title/Summary/Keyword: river bank filtration

Search Result 25, Processing Time 0.024 seconds

Variation of Filamentous Periphyton Chlorophyll-a in accordance with Water Velocity and Specific Surface Area of Media in Small Urban Stream (도시 소하천에서 유속, 비표면적에 따른 사상형 부착조류의 Chlorophyll-a 변화)

  • Ahn, Chang Hyuk;Joo, Jin Chul;Lee, Saeromi;Oh, Ju Hyun;Ahn, Hosang;Song, Ho Myeon
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.551-558
    • /
    • 2013
  • The feasibility of water supply as in-stream flow for Mangwall stream was analyzed in terms of water quality and cultivation periphyton using two different types of water resources (e.g., surface water and bank filtration from Han River basin) and three different types of media (e.g., tile, concrete and pebble). The concentrations of organic and inorganic contaminants from the bank filtration were lower than those from surface water by 17.5 - 55.0%. Using water samples collected from Mangwall stream, surface water, and bank filtration, chlorophyll-a, phaeopigment, and growth rate of periphyton were investigated. During 30 day incubation for each water sample, it was observed that filamentous cyanobacteria, Oscillatoriaceae, accounted for 98%, and water velocity of 5 cm/s was optimum for the in situ filamentous cyanobacteria growth. Also, it was deducted for water velocity and chl-a to have an inverse correlation. Meanwhile, the greater the specific surface area of media, the higher the concentration of chl-a. From these results, both water velocity and specific surface area of media should be considered as an combined parameter to deter the growth of filamentous cyanobacteria.

창원시 대산면 강변여과수의 수질과 낙동강 수질의 관련성 연구

  • 장성;함세영;김형수;차용훈;정재열
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.451-454
    • /
    • 2004
  • The study aims to assess the quality of bank filtrate in relation to streamflow and physico-chemical properties of the stream. Turbidity, pH, temperature and dissolved oxygen (DO) of Nakdong River and riverbank filtrate were statistically analyzed. The physico-chemical properties of riverbank filtrate were measured from irregularly different seven pumping wells every day. Autocorrelation analyses were conducted to the qualities of stream water and bank filtrated water. Temperature, pH and DO of streamflow shows strong linearity and long memory effect, indicating the effect of seasonal air temperature and rainy season. Temperature of riverbank filtrate shows weak linearity and weak memory, indicating differently from the trend of stream temperature. Turbidity of steramflow shows strong linearity and long memory effect, while turbidity of riverbank filtrate indicates weak linearity and weak memory. Cross-correlation analysis shows low relation between turbidity, pH, temperature and DO of riverbank filtrate and those of streamflow. Turbidity of streamflow was largely affected by the streamflow rate, showing a similar trend with autocorrelation function of streamflow rate. The turbidity of riverbank filtrate has a lag time of 25 hours. This indicates that turbidity of streamflow in a dry season has very low effect on the turbidity of riverbank filtrate, and a high turbidity of the stream in a rainy season has a fairly low effect on the turbidity of riverbank filtrate.

  • PDF

Geochemical Characteristics of Groundwater during the Constant and Step-drawdown Pumping Tests at the River Bank Filtration Site (장기 및 단계 양수시험 시 강변여과 지하수의 수질변화 특성)

  • Kim, Gyoobum;Shin, Seonho;Kim, Byungwoo;Park, Joonhyung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.8
    • /
    • pp.11-21
    • /
    • 2013
  • In-situ test to find the change of $Fe^{2+}$ and $Mn^{2+}$ concentrations and ion contents in groundwater was conducted during two pumping tests at the riverbank filtration site, where is the riverine area of the Nakdong River in Changnyeong-Gun. Groundwater was sampled at one pumping well and 10 monitoring wells during a 5 steps drawdown pumping test with the rates from $500m^3/day$ to $900m^3/day$ and a constant pumping test with $800m^3/day$. The change in ion concentration of groundwater was more remarkable during a step drawdown pumping test than a constant pumping test. Especially, the decrease in $Fe^{2+}$ and $Mn^{2+}$ concentrations was distinct in a step drawdown pumping test and it happens predominantly along the direction that the radius of pumping influence was small due to a good aquifer connectivity to a pumping position. The precipitation and the oxidation of iron and manganese were caused by an air inflow and a disturbance in groundwater flow due to an abrupt change in pumping rate. The pumping rate and spatial distribution of an aquifer around a pumping well need to be considered as an important factor for the development of in-situ iron and manganese treatment technology.

Determining Optimum Pumping Rates of Groundwater in Ttansum Island Related to Riverbank Filtration

  • Lee, Chung-Mo;Hamm, Se-Yeong;Choo, Yeon-Woo;Kim, Hyoung-Soo;Cheong, Jae-Yeol
    • Journal of Environmental Science International
    • /
    • v.27 no.10
    • /
    • pp.831-844
    • /
    • 2018
  • Riverbank Filtration (RBF) is a kind of indirect artificial recharge method and is useful in obtaining higher-quality source water than surface water when procuring municipal water. This study evaluated optimal riverbank filtered water and the productivity of the radial collector wells on Ttansum Island in the area downstream of the Nakdong River, where Gimhae City is constructing a municipal water plant for the purpose of acquiring high-quality water. The RBF wells are planned to provide water to the citizens of Gimhae City through municipal water works. Groundwater flow modeling was performed with the following four scenarios: (a) 9 radial collector wells, (b) 10 radial collector wells, (c) 10 radial collector wells and two additional vertical wells, and (d) 12 radial collector wells. This study can be useful in determineing the optimum production rate of bank filtrated water not only in this study area but also in other places in Korea.

Field Measurement of Surface Hydraulic Conductivity Distribution Using Guelph Permeameter : A Case Study in the Riverbank Filtration Site of Kimhae (Ddanseom) (Guelph 투수계를 이용한 김해시 딴섬 강변여과수 지역의 지표 수리전도도 분포 조사)

  • Jeong, Jae-Hoon;Kim, Hyoung-Soo
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.2
    • /
    • pp.36-43
    • /
    • 2008
  • A method estimating unsaturated hydraulic conductivity using Guelph permeameter was developed and applied to the Ddanseom area of Kimhae in Nakdong River basin where the facilities producing bank-filtrated groundwaters are currently under construction. It is believed that the hydraulic conductivity values obtained from this study are useful in determination of recharges through unsaturated zone or from the river. The distribution of the surface hydraulic conductivity shows that sediments are finer downstream, implying the downstream part of Ddanseom has the higher potential of groundwater production.

Characterization of Groundwater Flow to Horizontal or Slanted Well Using Numerical Modeling (수치 모사를 활용한 수평 혹은 경사형 특수 정호 지하수 흐름 특성 평가)

  • Kim, Hyoung-Soo
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.2
    • /
    • pp.54-61
    • /
    • 2008
  • The drawdown distribution due to pumping by horizontal or slanted wells is analyzed by numerical modelling. In the numerical modelling uses 1-D discrete element feature included in commercial groundwater modeling program FEFLOW (version 5.1) and the results are compared with the semi analytic solution which uses superposition of successive point sources proposed by Zhan and Zlotnik (2002). Results of the numerical modeling agree well with the semi analytic solution except for very near field region of sink sources. The drawdown distribution due to pumping in riverbank filtration(RBF) plan site can be evaluated quantitatively by the numerical modeling in this study.

Effect of Experimental Factors on Manganese Removal in Manganese Sand Filtration (망간모래여과공정에서 망간제거에 미치는 영향인자)

  • Kim, Berm-Soo;Yoon, Jaekyung;Ann, Hyo-Won;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.86-93
    • /
    • 2006
  • In the drinking water treatment, the aesthetic and color problem are caused by the manganese which is occurring and present in the surface, lake and ground water. The most common treatment processes for removing manganese are known for oxidation followed by filtration. In this study, the manganese sand process was used for removing manganese with river bank filtrate as a source. In the manganese sand process, the residual chlorine and pH are important factors on the continuous manganese oxidation. In addition, space velocity (SV) and alum dosage are play a role of manganese removal. Even though manganese removal increased with increasing chlorine concentration, the control of residual chlorine is actually difficult in this process As the results of tests, the residual chlorine concentration as well as manganese removal were effectively achieved at pH 7.5. The optimum attached manganese concentration on manganese sand was confirmed to 0.3mg/L by the experimental result of a typical sand converting to manganese sand.

Evaluation of Contaminant Retardation Capacities of Bank Aquifer Materials (강변 대수층 매질 시료의 오염물질 지연능 평가)

  • Kim, Jae Young;Oh, Dong Ik;Park, Dong Woon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.62-71
    • /
    • 1999
  • The containment retardation capacities of four different aquifers were evaluated in a preliminary study for development of bank filtration in the Young San river area. $NO_3-N$, $NO_2-N$, $NH_4^+-N$, Fe, Mn, phenol, and chloride were selected as the target contaminants and a nonreactive tracer, respectively. Batch isotherm tests were conducted to measure the partition coefficients of the target contaminants. The mass transport parameters of nonreactive tracer were estimated from column tests. From the results of bath isotherm tests, it was shown that lower stream aquifer materials have greater partition coefficients of $NO_3-N$, $NH_4^+-N$, Mn, and phenol than the upper stream aquifer materials; however, there was no significant position-dependent trend for Fe. All aquifer materials tested have the same range of partition coefficients for $NO_2-N$. Column tests showed that the molecular diffusion of Cl- was much less than the mechanical dispersion; and there was no significant difference between the estimated dispersivities of tested aquifer materials. Consequently, it seems that the difference in the containment retardation capacities between four aquifers tested in this study would primarily result not from hydrodynamic dispersion but from partitioning.

  • PDF

Calculation of the Yield of Bank Filtration by Using the Horizontal Collector Wells (방사형 집수정에 의한 강변여과수 산출량 산정에 관한 연구)

  • Chung Ji-hoon;Park Jae-hyeon;Park Chang-kun;Yang Jung-suk;Kim Dae-kun;Jeong Kyo-cheol;Choi Youg-sun;Bu Sung-an
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.417-427
    • /
    • 2004
  • The horizontal collector well is used to treat some weak points of the vertical well in the bank filtration site. In this study two empirical formulas(Milojevic and Petrovic) are selected to examine the applicability for calculating the yield of the horizontal collector. And they are compared with the compute simulation results for multiple wells. Milojevic empirical formula which considers the conditions such as aquifer, well location, the diameter of screen etc. is more applicable than Petrovic formula. Draw-down characteristics of horizontal collector was well simulated by using the computer simulation for multiple wells. The results are well agreement with Milojevic formula, and the draw-down and the retention time of the horizontal collector can be controlled by adjusting the angle of lateral screens.

Application of the Artificial Recharge to Reduce the Ground-water Drawdown of the River Bank Filtration (강변여과수 취수시 과도한 지하수 하강을 저감시키기 위한 인공함양의 활용 방안)

  • Lee, Dong Kee;Park, Jae Hyeoun;Park, Chang Kun;Kim, Sang Jun;Nam, DoHyeoun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.236-240
    • /
    • 2004
  • 강변여과수의 과도한 취수는 제내지 지하수위 하강을 발생하게 되며 이로 인해서 제내지 농경지의 토양 건조도가 증가되어 과도한 관계용수의 보충이 필요할 뿐말 아니라 지하수위 하강으로 인한 기존 관정사용이 어려워져 더 깊은 새로운 관정을 개발해야만 한다.. 이러한 기하수위 하강을 저감시키기 위한 방안으로 제내 지측에 인공함양우물을 설치하는 방법 있다. 창원시 강변여과 시설에 적용한 결과 인공함양우물의 최적 위치는 취수정으로부터 세내지 측으로 200m 지점에 위치하며, 함양량을 취수량의 $5\%$를 유지하는 것이 지하수위를 저감하기위한 효과적인 조건으로 판단되었다.

  • PDF