• Title/Summary/Keyword: risk assessment system

Search Result 1,376, Processing Time 0.031 seconds

Establishment and Standardization of Evaluation Procedure for Urban Flooding Analysis Model Using Available Inundation Data (가용 침수 자료를 활용한 도심지 침수 해석 모형의 평가 절차 수립 및 표준화)

  • Shin, Eun Taek;Jang, Dong Min;Park, Sung Won;Eum, Tae Soo;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.100-110
    • /
    • 2020
  • Recently, the frequency of typhoon and torrential rain due to climate change is increasing. In addition, the upsurge in the complexity of urban sewer network and impervious surfaces area aggravates the inland flooding damage. In response to these worsening situations, the central and local governments are conducting R&D tasks related to predict and mitigate the flood risk. Researches on the analysis of inundation in urban areas have been implemented through various ways, and the common features were to evaluate the accuracy and justification of the model by comparing the model results with the actual inundation data. However, the evaluation procesure using available urban flooding data are not consistent, and if there are no quantitative urban inundation data, verification has to be performed by using press releases, public complaints, or photos of inundation occurring through 'CCTV'. Because theses materials are not quantitative, there is a problem of low reliability. Therefore, this study intends to develop a comparative analysis procedure on the quantitative degree and applicability of the verifiable inundation data, and a systematic framework for the performance assessment of urban flood analysis model was proposed. This would contribute to the standardization of the evaluation and verification procedure for urban flooding modelling.

Effects of Insamsansa-eum (Renshenshanzha-yin) on Hypercholesterolemia and Analysis of Its Effects according to the Pattern Identification

  • Park Seong-Uk;Jung Woo-Sang;Moon Sang-Kwan;Cho Ki-Ho;Kim Young-Suk;Bae Hyung-Sup;Ko Chang-Nam
    • The Journal of Korean Medicine
    • /
    • v.27 no.2 s.66
    • /
    • pp.253-261
    • /
    • 2006
  • Backgrounds : Hyperlipidemia is a major cause of cardiovascular disease (CVD). Lowering serum cholesterol levels could reduce the risk of CVD. Insamsansa-eum (Renshenshanzha-yin, ISE), composed of Ginseng Radix and Crataegii Fructus, is a new medicine developed to treat hyperlipidemia and CVD. Objectives : In this study, we intended to explore the clinical effects of ISE on patients with hypercholesterolemia, and moreover we also compared its effects according to the pattern identification. Methods : Subjects were administered ISE with the dose of 600 mg three times a day for 4 weeks. Patterns of subjects were identified with diagnostic scoring system for Yin-Yang and the condition of Excess-Deficiency before treatment. Serum lipids were measured at baseline and after 4 weeks of medication. Results : ISE lowered total cholesterol(TC), triglyceride(TG), total lipid(TL), phospholipid(PL) and low density lipoprotein cholesterol(LDL) significantly. Compared with the data of our previous study, it was less effective than Atorvastatin but showed equal lipids-lowering effect to Chunghyul-dan (Qingxue-dan, CHD). In Yang pattern group, ISE was less effective in lowering TG and LDL than it was in not-Yang-not-Yinpattern group. On safety assessment, there was no adverse effect, hepatic or renal toxicity. Conclusions : We suggest that ISE is a safe and useful herbal medicine for hypercholesterolemia, and moreover it could be more useful when it is used for patients with not Yang pattern.

  • PDF

Seismic vulnerability of old confined masonry buildings in Osijek, Croatia

  • Hadzima-Nyarko, Marijana;Pavica, Gordana;Lesic, Marija
    • Earthquakes and Structures
    • /
    • v.11 no.4
    • /
    • pp.629-648
    • /
    • 2016
  • This paper deals with 111 buildings built between 1962 and 1987, from various parts of the city of Osijek, for which, through the collection of documentation, a database is created. The aim of this paper is to provide the first steps in assessing seismic risk in Osijek applying method based on vulnerability index. This index uses collected information of parameters of the building: the structural system, the construction year, plan, the height, i.e., the number of stories, the type of foundation, the structural and non-structural elements, the type and the quality of main construction material, the position in the block and built-up area. According to this method defining five damage states, the action is expressed in terms of the macroseismic intensity and the seismic quality of the buildings by means of a vulnerability index. The value of the vulnerability index can be changed depending on the structural systems, quality of construction, etc., by introducing behavior and regional modifiers based on expert judgments. Since there is no available data of damaged buildings under earthquake loading in our country, we will propose behavior modifiers based on values suggested by earlier works and on judgment based on available project documentation of the considered buildings. Depending on the proposed modifiers, the seismic vulnerability of existing buildings in the city of Osijek will be assessed. The resulting vulnerability of the considered residential buildings provides necessary insight for emergency planning and for identification of critical objects vulnerable to seismic loading.

Paddy Rice Culture Experiment Using Treated Sewage Effluent From Constructed Wetland (인공습지 오수처리수를 이용한 벼재배 실험)

  • 윤춘경;함종화;우선호;김민희
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.2
    • /
    • pp.94-104
    • /
    • 2001
  • A pilot study was performed at the experimental field of Konkuk University in Seoul, to examine the feasibility of the constructed wetland system for sewage and the effect of treated sewage irrigation on the paddy rice culture and its soil characteristics. The constructed wetland performed well, in that effluent concentrations of pollutants were significantly lower than concentrations of the influent. Median removal efficiencies of BOD$_{5}$ was about 78% and slightly lower during winter. Removal efficiencies form TN and TP were approximately 48 and 21%, respectively, and relatively less effective than that of BOD$_{5}$. Irrigation of treated sewage to paddy rice culture did not affect adversely in both growth and yield of rice. Instead, plots of treated sewage irrigation showed up to 50% more yield in average than the control plot. It implies that treated sewage irrigation might be beneficial to rice culture rather than detrimental as long as it is treated adequately and used properly. Soil was sampled and analyzed before transplanting and after harvesting. pH was slightly increased due to irrigation water, but it may not be concerned as long as the treated sewage is within the normal range. EC was increased in first year but decreased in second year, therefore salts accumulation in the soil could be less concerned. OM and CES was slightly increased, which might be beneficial on growing plants. TN did not show apparent pattern. Available phosphorus was decreased after rice culture, but the quantity of phosphorus(TP-available phosphorus) was rather increased which implies that excessive phosphorus supply may result in phosphorus accumulation in the soil. Overall, the constructed wetland was thought to be an effective sewage treatment alternative, and treated sewage could be reused as a supplemental source of irrigation water for paddy rice culture without causing adverse effect as long as it is treated adequately and used properly. For full-scale application, further investigation should be followed on environmental risk assessment, tolerable water quality, and fraction of supplemental irrigation.ion.

  • PDF

Social Distancing and Public Health Guidelines at Workplaces in Korea: Responses to Coronavirus Disease-19

  • Kim, Eun-A
    • Safety and Health at Work
    • /
    • v.11 no.3
    • /
    • pp.275-283
    • /
    • 2020
  • Background: In the absence of a vaccine or treatment, the most pragmatic strategies against an infectious disease pandemic are extensive early detection testing and social distancing. This study aimed to summarize public and workplace responses to Coronavirus Disease-19 (COVID-19) and show how the Korean system has operated during the COVID-19 pandemic. Method: Daily briefings from the Korean Center for Disease Control and the Central Disaster Management Headquarters were assembled from January 20 to May 15, 2020. Results: By May 15, 2020, 11,018 COVID-19 cases were identified, of which 15.7% occurred in workplaces such as health-care facilities, call centers, sports clubs, coin karaoke, and nightlife destinations. When the first confirmed case was diagnosed, the Korean Center for Disease Control and Central Disaster Management Headquarters responded quickly, emphasizing early detection with numerous tests and a social distancing policy. This slowed the spread of infection without intensive containment, shut down, or mitigation interventions. After entering the public health blue alert level, a business continuity plan was distributed. After entering the orange level, the Ministry of Employment and Labor developed workplace guidelines for COVID-19 consisting of social distancing, flexible working schedules, early identification of workers with suspected infections, and disinfection of workplaces. Owing to the intensive workplace social distancing policy, workplaces remained safe with only small sporadic group infections. Conclusion: The workplace social distancing policy with timely implementation of specific guidelines was a key to preventing a large outbreak of COVID-19 in Korean workplaces. However, sporadic incidents of COVID-19 are still ongoing, and risk assessment in vulnerable workplaces should be continued.

Application of Quantum-dot Nanocrystals for Cyanobacterial Toxin-Microcystin Detection (나노크리스탈 Quantum-dot을 적용한 남조류 독소 Microcystin 탐지 연구)

  • Lee, Jinwook;Yu, Hye-Weon;Kim, In S.
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.705-711
    • /
    • 2007
  • Green quantum-dot nanocrystal (QD525) with anti-microcystin monoclonal antibody was applied for detection of microcystin, a monocyclic peptide hepatotoxin, extracted from the culture of Microcystis aeruginosa. The presence of microcystin in the cell lysate was verified by HPLC analysis with UV absorbance at 238 nm. Microcystis cell extract exhibited fluorescence emission spectra, which peak was around 460 nm because of their complex organic substances. When a spherical QD525 antibody conjugates (10~20 nm in diameter) were bound to the microcystins in the Microcystis cell lysate, the fluorescence intensity of the primary peak at 525 nm diminished while the secondary emission peak at 460 nm slightly increased intensities. It is due to energy transfer from the primary (major) to the secondary (minor) peak, resulting from physical deformation of QD525 and different environmental factors. On the other hand, other cell extracts did not show any fluorescence emission change. This study is very available for detecting and monitoring the microcystin because it is one step assay without washing step and portable spectrophotometer makes on-site measurement possible. For health risk assessment of the microcystin, the reliable and rapid system to detect and quantify microcystin is seriously required.

Evaluating Appropriateness of Medication Use in the Operating Rooms of a Tertiary Hospital: Based on Survey (일개 병원의 수술실 약제관련 업무 적정화 방안연구: 설문조사를 중심으로)

  • Lee, Ye Ji;Jeong, Kyeong Hye;Kim, Young Nam;Kim, Eun Young
    • Korean Journal of Clinical Pharmacy
    • /
    • v.26 no.3
    • /
    • pp.230-237
    • /
    • 2016
  • Background: Since the use of opioid analgesics is frequent in operation rooms (OR), the risk of medication error is high; however the use of medication in the OR has been operating independently with the hospital pharmacy. Therefore, the assessment on management of medication use in operation and the pharmacist's role is needed. Methods: We conducted the literature review and survey from anesthesiologists, operating nurses at Chung-Ang Hospital on management of medication for operation use, awareness on need for medication management efficiency, need for satellite pharmacy in the operating room and its effect. Results: 56% of medical staffs responded that management of medication in the operating room is efficient; however, 82.6% responded that they felt the inconvenience in medication delivery to the OR when additional prescription was ordered. 51.5% also responded that extra time was required for management of narcotics and inventory/record keeping. 80% agreed that there could be lost costs due to prescription missed. Medical staffs responded improving the drug management system could increase the OR efficiency (87%), and eventually bring the increase in hospital revenue (80.4%). Those who responded that implementation of OR satellite pharmacy was needed include physicians (84.6%), nurses (63.6%), and also responded that it'd bring more profit to the hospital by increasing the efficiency in OR (60.9%). Conclusion: For efficient management of medications, implementation of OR satellite pharmacy would lead to improved drug management and increased efficiency in OR and reduced cost and improved patient care.

Developing Sequential Sampling Plans for Evaluating Maize Weevil and Indian Meal Moth Density in Rice Warehouse (쌀 저장창고에서 어리쌀바구미와 화랑곡나방 밀도 추정을 위한 축차추출 조사법 (Sequential sampling plans) 개발)

  • Nam, Young-Woo;Chun, Yong-Shik;Ryoo, Mun-Il
    • Korean journal of applied entomology
    • /
    • v.48 no.1
    • /
    • pp.45-51
    • /
    • 2009
  • This paper presents sequential sampling plans for evaluating the pest density based on complete counts from probe in a rice storage warehouse. Both maize weevil and Indian meal moth population showed negative binomial dispersion patterns in brown rice storage. For cost-effective monitoring and action decision making system, sequential sampling plans by using the sequential probability ratio test (SPRT) were developed for the maize weevil and Indian meal moth in warehouses with 0.8 M/T storage bags. The action threshold for the two insect pests was estimated to 5 insects per kg, which was projected by a matrix model. The results show that, using SPRT methods, managers can make decisions using only 20 probe with a minimum risk of incorrect assessment.

A Structured Methodology of Optimal Combination of Eco-Energy Development Technologies: Focusing on Wind Power Technology Combination (친환경 에너지 개발 기술 최적 조합 선정을 위한구조적 방법론: 풍력 발전 기술 조합 선정을 중심으로)

  • Kwon, Ohbyung;Cui, Nan
    • Journal of Environmental Policy
    • /
    • v.10 no.1
    • /
    • pp.93-127
    • /
    • 2011
  • Investment on technology to obtain green energy is prevailing all over the world. The technology development project is more likely to involve multiple sub-projects, each of which is related to develop elementary technology when the project is larger and nation-wide. However, the methodologies identifying optimal combination of elementary technologies among the candidates have been very few. Hence, the purpose of this paper is to propose a novel methodology which provides an optimal combination of green energy technologies. To do so, to-be developed technologies are clustered with multiple categories. Among the technologies, based on Delphi method, the experts select a representative technology, which is indispensible to the green energy system and has the highest connectivity with other elementary technologies. Then the methodology selects an elementary technology from each technology category based on two metrics: Relatedness with representative technology and project risk. To show the feasibility of the proposed methodology, we applied the methodology to an actual windmill development project.

  • PDF

Seismic Risk Assessment of Existing Low-rise Reinforced Concrete Buildings in Korea

  • LEE, Kang Seok;Jung, Ju-Seong;Choi, Yun-Chul
    • Architectural research
    • /
    • v.20 no.1
    • /
    • pp.17-25
    • /
    • 2018
  • Countermeasures against earthquake disasters such as the seismic capacity evaluation and/or retrofit schemes of buildings, especially existing low-rise reinforced concrete buildings, have not been fully performed since Korea had not experienced many destructive earthquakes in the past. However, due to more than 1200 earthquakes with low or moderate intensity in the off-coastal and inland of Korea during the past 20 years, and due to the recent moderate earthquakes in Korea, such as the 2016 Gyeongju Earthquake with M=5.8 and the 2017 Pohang Earthquake with M=5.4, the importance of the future earthquake preparedness measures is highly recognized in Korea. The main objective of this study is to provide the basic information regarding seismic capacities of existing low-rise reinforced concrete buildings in Korea. In this paper, seismic capacities of 14 existing low-rise reinforced concrete public buildings in Korea are evaluated based on the Japanese Standard for Evaluation of Seismic Capacity of Existing Reinforced Concrete Buildings. Seismic capacities between existing buildings in Korea and those in Japan is compared, and the relationship of seismic vulnerability of Korean buildings and Japanese buildings damaged due to severe earthquakes are also discussed. Results indicated that Korean existing low-rise reinforced concrete buildings have a narrow distribution of seismic capacities and they are relatively lower than Japanese buildings, and are also expected to have severe damage under the earthquake intensity level experienced in Japan. It should be noted from the research results that the high ductility in Korean existing low-rise buildings obtained from the Japanese Standard may be overestimated, because most buildings investigated herein have the hoop spacing wider than 30 cm. In the future, the modification of strength and ductility indices in the Japanese Standard to propose the seismic capacity evaluation method of Korean buildings is most needed.