• 제목/요약/키워드: rise height

검색결과 506건 처리시간 0.024초

Numerical study on Floor Response Spectrum of a Novel High-rise Timber-concrete Structure

  • Xiong, Haibei;Zheng, Yingda;Chen, Jiawei
    • 국제초고층학회논문집
    • /
    • 제9권3호
    • /
    • pp.273-282
    • /
    • 2020
  • An innovative high-rise timber-concrete hybrid structure was proposed in previous research, which is composed of the concrete frame-tube structure and the prefabricated timber modules as main structure and substructures, respectively. Considering that the timber substructures are built on the concrete floors at a different height, the floor response spectrum is more effective in estimating the seismic response of substructures. In this paper, the floor response spectra of the hybrid structure with different structural parameters were calculated using dynamic time-history analysis. Firstly, one simplified model that can well predict the seismic response of the hybrid structure was proposed and validated. Then the construction site, the mass ratio and the frequency ratio of the main-sub structure, and the damping ratio of the substructures were discussed. The results demonstrate that the peaks of the floor response spectra usually occur near the vibration periods of the whole structure, among which the first two peaks stand out; In most cases, the acceleration amplification effect on substructures tends to be more evident when the construction site is farther from the fault rupture; On the other hand, the acceleration response of substructures can be effectively reduced with an appropriate increase in the mass ratio of the main-sub structure and the damping ratio of the substructures; However, the frequency ratio of the main-sub structure has no discernible effect on the floor response spectra. This study investigates the characteristics of the floor response spectrum of the novel timber-concrete structure, which supports the future applications of such hybrid structure in high-rise buildings.

Ductility demands and reduction factors for 3D steel structures with pinned and semi-rigid connections

  • Llanes-Tizoc, Mario D.;Reyes-Salazar, Alfredo;Ruiz, Sonia E.;Bojorquez, Eden;Bojorquez, Juan;Leal Graciano, Jesus M.
    • Earthquakes and Structures
    • /
    • 제16권4호
    • /
    • pp.469-485
    • /
    • 2019
  • A numerical investigation regarding local (${\mu}_L$) and story (${\mu}_S$) ductility demand evaluation of steel buildings with perimeter moment resisting frames (PMRF) and interior gravity frames (IGF), is conducted in this study. The interior connections are modeled, firstly as perfectly pinned (PP), and then as semi-rigid (SR). Three models used in the SAC steel project, representing steel buildings of low-, mid-, and high-rise, are considered. The story ductility reduction factor ($R_{{\mu}S}$) as well as the ratio ($Q_{GL}$) of $R_{{\mu}S}$ to ${\mu}_L$ are calculated. ${\mu}_L$ and ${\mu}_S$, and consequently structural damage, at the PMRF are significant reduced when the usually neglected effect of SR connections is considered; average reductions larger than 40% are observed implying that the behavior of the models with SR connections is superior and that the ductility detailing of the PMRF doesn't need to be so stringent when SR connections are considered. $R_{{\mu}S}$ is approximately constant through height for low-rise buildings, but for the others it tends to increase with the story number contradicting the same proportion reduction assumed in the Equivalent Static Lateral Method (ESLM). It is implicitly assumed in IBC Code that the overall ductility reduction factor for ductile moment resisting frames is about 4; the results of this study show that this value is non-conservative for low-rise buildings but conservative for mid- and high-rise buildings implying that the ESLM fails evaluating the inelastic interstory demands. If local ductility capacity is stated as the basis for design, a value of 0.4 for $Q_{GL}$ seems to be reasonable for low- and medium-rise buildings.

Mitigation of seismic pounding between RC twin high-rise buildings with piled raft foundation considering SSI

  • Farghaly, Ahmed Abdelraheem;Kontoni, Denise-Penelope N.
    • Earthquakes and Structures
    • /
    • 제22권6호
    • /
    • pp.625-635
    • /
    • 2022
  • High-rise buildings (HRBs) are considered one of the most common structures nowadays due to the population growth, especially in crowded towns. The lack of land in crowded cities has led to the convergence of the HRBs and the absence of any gaps between them, especially in lands with weak soil (e.g., liquefaction-prone soil), but then during earthquakes, these structures may be exposed to the risk of collision between them due to the large increase in the horizontal displacements, which may be destructive in some cases to the one or both of these adjacent buildings. To evaluate methods of reducing the risk of collision between adjacent twin HRBs, this research investigates three vibration control methods to reduce the risk of collision due to five different earthquakes for the case of two adjacent reinforced concrete (RC) twin high-rise buildings of 15 floors height without gap distance between them, founded on raft foundation supported on piles inside a liquefaction-prone soil. Contact pounding elements between the two buildings (distributed at all floor levels and at the raft foundation level) are used to make the impact strength between the two buildings realistic. The mitigation methods investigated are the base isolation, the tuned mass damper (TMD) method (using traditional TMDs), and the pounding tuned mass damper (PTMD) method (using PTMDs connected between the two buildings). The results show that the PTMD method between the two adjacent RC twin high-rise buildings is more efficient than the other two methods in mitigating the earthquake-induced pounding risk.

Non-Gaussian feature of fluctuating wind pressures on rectangular high-rise buildings with different side ratios

  • Jia-hui Yuan;Shui-fu Chen;Yi Liu
    • Wind and Structures
    • /
    • 제37권3호
    • /
    • pp.211-227
    • /
    • 2023
  • To investigate the non-Gaussian feature of fluctuating wind pressures on rectangular high-rise buildings, wind tunnel tests were conducted on scale models with side ratios ranging from 1/9~9 in an open exposure for various wind directions. The high-order statistical moments, time histories, probability density distributions, and peak factors of pressure fluctuations are analyzed. The mixed normal-Weibull distribution, Gumbel-Weibull distribution, and lognormal-Weibull distribution are adopted to fit the probability density distribution of different non-Gaussian wind pressures. Zones of Gaussian and non-Gaussian are classified for rectangular buildings with various side ratios. The results indicate that on the side wall, the non-Gaussian wind pressures are related to the distance from the leading edge. Apart from the non-Gaussianity in the separated flow regions noted by some literature, wind pressures behind the area where reattachment happens present non-Gaussian nature as well. There is a new probability density distribution type of non-Gaussian wind pressure which has both long positive and negative tail found behind the reattachment regions. The correlation coefficient of wind pressures is proved to reflect the non-Gaussianity and a new method to estimate the mean reattachment length of rectangular high-rise building side wall is proposed by evaluating the correlation coefficient. For rectangular high-rise buildings, the mean reattachment length calculated by the correlation coefficient method along the height changes in a parabolic shape. Distributions of Gaussian and non-Gaussian wind pressures vary with side ratios. It is inappropriate to estimate the extreme loads of wind pressures using a fixed peak factor. The trend of the peak factor with side ratios on different walls is given.

Multi-Beams modelling for high-rise buildings subjected to static horizontal loads

  • Sgambi, Luca
    • Structural Engineering and Mechanics
    • /
    • 제75권3호
    • /
    • pp.283-294
    • /
    • 2020
  • In general, the study of a high-rise building's behaviour when subjected to a horizontal load (wind or earthquake) is carried out through numerical modelling with finite elements method. This paper proposes a new, original approach based on the use of a multi-beams model. By redistributing bending and axial stiffness of horizontal elements (beams and slabs) along vertical elements, it becomes possible to produce a system of differential equations able to represent the structural behaviour of the whole building. In this paper this approach is applied to the study of bending behaviour in a 37-storey building (Torre Pontina, Latina, Italy) with a regular reinforced concrete structure. The load considered is the wind, estimated in accordance with Italian national technical rules and regulations. To simplify the explanation of the approach, the wind load was considered uniform on the height of building with a value equal to the average value of the wind load distribution. The system of differential equations' is assessed numerically, using Matlab, and compared with the obtainable solution from a finite elements model along with the obtainable solutions via classical Euler-Bernoulli beam theory. The comparison carried out demonstrates, in the case study examined, an excellent approximation of structural behaviour.

원형 밀폐 및 개방형 돔 지붕의 풍압 스펙트럼 (Wind Pressure Spectra for Circular Closed and Open Dome Roofs)

  • 천동진;김용철;이종호;윤성원
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.69-76
    • /
    • 2020
  • Wind tunnel tests were conducted to analyze the wind fluctuating pressures on a circular closed and open dome roof with a low span rise. Two dome models with various geometric parameters (height/span ratios and open ratios) were used for fixed span rise ratio dome and wind pressure spectrum were analyzed. The applicability was examined in comparison with the spectral model proposed in the previous studies. The analysis results show that the wind pressure spectrum of open dome roof tends to increase power in the high frequency range and the second peak is found in the area different from the closed dome roof. In addition, according to the comparison analysis with the previous proposed spectral model, it was found that it is not applicable to the closed and open dome roofs with low rise ratio due to the different peak frequencies.

강우특성을 고려한 불포화토 사면의 안정성 해석 (Stability Analysis of Slope in Unsaturated Soil Based on the Characteristics of Rainfall)

  • 이관영;이강일;김찬기;장용채
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.663-668
    • /
    • 2005
  • The present study proposed to examine the appropriateness of the ground water level condition that had a significant effect on the stability of the slopes and, for this purpose, analyzed the rise of ground water level during the rainy season by applying the average daily rainfall of Seoul for the last 30 years. The result showed that the rise of ground water level was 6.0$\sim$41.0% of the slope height, which suggests that the currently applied condition of ground water level is somewhat overestimated. In addition, the result of interpreting the stability of slopes during the rainy season, slopes were unstable in all conditions when the ground water level was at the ground surface and base failure occurred. This suggests the importance of ground water level condition in stability analysis.

  • PDF

Serviceability evaluation methods for high-rise structures considering wind direction

  • Ryu, Hye-Jin;Shin, Dong-Hyeon;Ha, Young-Cheol
    • Wind and Structures
    • /
    • 제30권3호
    • /
    • pp.275-288
    • /
    • 2020
  • High-rise buildings are very slender and flexible. Their low stiffness values make them vulnerable to horizontal loads, such as those associated with wind or earthquakes. For high-rise buildings, the threat to serviceability caused by wind-induced vibration is an important problem. To estimate the serviceability under wind action, the response acceleration of a building at the roof height is used. The response acceleration is estimated by the same wind speed at all wind directions. In general, the effect of wind direction is not considered. Therefore, the response accelerations obtained are conservative. If buildings have typical plans and strong winds blow from relatively constant wind directions, it is necessary to account for the wind direction to estimate the response accelerations. This paper presents three methods of evaluating the response accelerations while considering the effects of wind direction. These three serviceability evaluation methods were estimated by combining the wind directional frequency data obtained from a weather station with the results of a response analysis using wind tunnel tests. Finally, the decrease in the efficiencies of the response acceleration for each serviceability evaluation method was investigated by comparing the response acceleration for the three methods accounting for wind direction with the response acceleration in which wind direction was not considered.

초고층 건축물의 용도별 피난안전구역 성능확보 방안에 관한 연구 (A Study on the Improvement of the Refuge safety area in High-rise Buildings Type)

  • 이병현;이경희
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.288-292
    • /
    • 2016
  • The purpose of this study was to improve the refuge safety area in the high-rise building type. Each simulation was conducted to evaluate the performance of three types in improving the refuge safety area. Targeting the first 63 floors (no refuge safety area), secondly, to target up to the $30^{th}$ floor (refuge safety area on the $30^{th}$ floor, $47^{th}$ floor) specified in domestic laws, and finally, the $20^{th}$ floor (evacuation safety area on the $20^{th}$ floor, $42^{th}$ floor) were considered as targets. Through this analysis, the following results were obtained : The floor for the refuge safety area through simulations showed that the evacuation time is low. It is necessary to improve the floor for the refuge safety area by using the characteristics of the domestic fire fighting vehicle. The first floor for the refuge safety area from the ground floor differs according to the distance and height of the building floor. However, in the case of a business facility it is 15F, and in the case of apartment housing, it is 20F.

A study on accumulated damage of steel wedges with dead-rise 10° due to slamming loads

  • Seo, Byoungcheon;Truong, Dac Dung;Cho, Sangrai;Kim, Dongju;Park, Sookeun;Shin, Hyunkyoung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권4호
    • /
    • pp.520-528
    • /
    • 2018
  • This paper presents the results of experimental investigation on the elastic-plastic response of steel unstiffened wedges with dead-rise $10^{\circ}$ subjected to repeated impulsive pressure loadings. Repeated drop tests were performed with both wedge thickness and drop height varied. The pressure and histories were recorded during the tests and the permanent deflections were measured after every drop. Using the recorded test result, the effects of flexibility of wedges and repetition have been investigated. From the pressure history obtained from the tests the characteristics of the impulses were identified. Numerical simulations of the tests were made using the measured pressure history and the permanent deflection predictions were compared with those of the experiments.