• Title/Summary/Keyword: rigid fixation

Search Result 161, Processing Time 0.026 seconds

Free Hand Insertion Technique of S2 Sacral Alar-Iliac Screws for Spino-Pelvic Fixation : Technical Note, Acadaveric Study

  • Park, Jong-Hwa;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.578-581
    • /
    • 2015
  • A rigid spino-pelvic fixation to anchor long constructs is crucial to maintain the stability of long fusion in spinal deformity surgery. Besides obtaining immediate stability and proper biomechanical strength of constructs, the S2 alar-iliac (S2AI) screws have some more advantages. Four Korean fresh-frozen human cadavers were procured. Free hand S2AI screw placement is performed using anatomic landmarks. The starting point of the S2AI screw is located at the midpoint between the S1 and S2 foramen and 2 mm medial to the lateral sacral crest. Gearshift was advanced from the desired starting point toward the sacro-iliac joint directing approximately $20^{\circ}$ angulation caudally in sagittal plane and $30^{\circ}$ angulation horizontally in the coronal plane connecting the posterior superior iliac spine (PSIS). We made a S2AI screw trajectory through the cancellous channel using the gearshift. We measured caudal angle in the sagittal plane and horizontal angle in the coronal plane. A total of eight S2AI screws were inserted in four cadavers. All screws inserted into the iliac crest were evaluated by C-arm and naked eye examination by two spine surgeons. Among 8 S2AI screws, all screws were accurately placed (100%). The average caudal angle in the sagittal plane was $17.3{\pm}5.4^{\circ}$. The average horizontal angle in the coronal plane connecting the PSIS was $32.0{\pm}1.8^{\circ}$. The placement of S2AI screws using the free hand technique without any radiographic guidance appears to an acceptable method of insertion without more radiation or time consuming.

The usefulness of intermolar traction wiring for restoration of maxillary & mandibular dental arch in facial bone fracture (안면골 골절에서 상하악 치열궁 복원을 위한 양측 대구치간 철사견인술의 유용성)

  • Jeong, Jae Ho;Shin, Seung Kyu;Lee, Jun Ho;Kim, Yong Ha
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.56-60
    • /
    • 2009
  • Purpose: Palatal fracture and mandible fracture result in instability of dental arch. Because they divide the maxillary and mandibular alveolus sagittally and / or transversely and comminute the dentition, they permit rotation of dental alveolar segments and significantly increase the potential for fracture malalignment, complicating fracture treatment. Previous treatment of palatal fracture consisted of palatal splint application and rigid palatal vault stabilization. This procedure result in patient's oral discomfort and removal of palate and screw. Mandible fracture often results in malocclusion due to widening of posterior aspect of dental arch. So we introduce more simple method using intermolar traction wiring, which can protect the widening of dental arch and rotation of dental alveolar segment. Methods: Arch bar and intermolar traction wiring with wire 1 - 0, or 2 - 0 was applied. After exposure of fracture line, neutrooclusion was maintained with intermaxillary fixation. And then open reduction & internal fixation on maxillary fracture line, commonly maxillary buttress, alveolar ridge, pyriform aperture except palatal vault or mandibular fracture line. After 1 week, intermolar traction wiring was removed. We checked occlusion and postoperative radiologic finding. Results: From June of 2007 to October of 2007, 10 patient, who have maxillary fracture with palatal fracture and mandible fracture, underwent open reduction & internal fixation with intermolar traction wiring. All have satisfactory occlusion and there were no complication, like gingiva disease, mouth opening impairment and nonunion. Conclusion: The intermolar traction wiring accompany open reduction and internal fixation can be alternative method for restoration of dental arch in facial bone fracture.

CLINICAL EVALUATION OF TREATMENT OUTCOME OF PLATING TECHNIQUE OF FIXATION FOR MANDIBULAR CONDYLAR FRACTURE (하악 과두 골절의 관혈적 정복시 고정 방법에 따른 임상적 평가)

  • Son, Jung-Hee;Park, Ji-Hwa;Kim, Chin-Soo;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.164-170
    • /
    • 2005
  • The purpose of this study was to compare a sample of patients who had condylar fractures treated with open reduction using different plating techniques, to evaluate which plating technique is useful for stable fixation for fractures of the mandibular condyle and to evaluate effectiveness of resorbable miniplate. There were 60 patients (41 males, 19 females) whose condylar fractures were treated with open reduction. Rigid fixation was performed with a single miniplate, double miniplate ot one miniplate & one microplate and single resorbable plate. All patients remained intermaxillary fixation for 1 week postoperatively. Active physiotherapy was started after 2 weeks postoperatively. Radiographic evaluation (plate fracture, plate bending, screw loosening, displacement of condyle etc.) was performed at pre-operative, immediate, 2 weeks, 1 month, 3 months, 6 months after surgery. Clinical evaluation included degree of mouth opening, occlusion, mandibular lateral excursion, infection and facial nerve paralysis. In radiographic evaluation, displacement of fractured condylar segment associated with plate bending or screw loosening were showed 6 cases and 3 cases for single miniplate system and resorbable miniplate system. There was no patients who have this problem on double miniplate system. The results revealed that the application of two miniplates were more recommendable than single miniplates. When we select resorbable miniplate system, we should consider the type of fractures, post-operative treatment protocol and surgical technique.

Treatment of Metacarpal Bone Fracture Using Biodegradable Plates and Screws (흡수성 고정판과 나사를 이용한 중수골 골절의 치료)

  • Cho, Jeong-Mok;Eun, Seok-Chan;Baek, Rong-Min
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.458-464
    • /
    • 2011
  • Purpose: Metacarpal fractures are common hand injury that may require operative intervention to ensure adequate reduction and stabilization. Traditionally, titanium miniplate was used for rigid fixation of bone fractures. However, the use of permanent plate lends itself to multiple complications such as infection, exposure of the hardware, tendon adhesions, tendon rupture, prolonged pain, bony atrophy and osteoporosis (stress shielding), metal sensitization, and palpation under the skin. This study evaluated the usefulness and stability of biodegradable plates and screws for treatment of metacarpal bone fractures. Methods: There was 17 patients who had surgery for metacarpal bone fracture from April 2007 to June 2010. All patients had open reduction and internal fixation. We used absorbable plates and screws (Inion CPS$^{(R)}$) for internal fixation. Postoperative results were assessed with x-ray. Stability of plates and screws, healing process and its complications were observed by clinical and radiographic assessment. Results: All patients were successfully reduced of bone fracture, and fixations with absorbable plates and screws were stable. The mean follow up period was 7.1 months. 2 patients complained postoperative pain, but they were relieved with analgesics. All patients experienced transient stiffness, but they were relieved with active assistive range of motion after removal of splint. No patients suffered complications which could be occurred by using metallic plate. Conclusion: There was no critical complications such as re-fracture or nonunion among patients. No patients suffered side effects related with metallic implants. Biodegradable implants can offer clinically stable and attractive alternative to metallic implants to stabilize metacarpal bone fractures in the hand.

SURGICAL CORRECTION OF SEVERE MANDIBULAR PROGNATHISM BY OBWEGESER II AND RIGID INTERNAL FLXATION (심한 하악골 전돌증 환자의 외과적 치험례)

  • Lee, Geon-Ho;Kwon, Dae-Geon;Jang, Do-Geon;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.1
    • /
    • pp.33-42
    • /
    • 1994
  • Obwegeser II method and Rigid fixation conserving the condylar position has been performed on 5 patients with severe mandibular prognathism, and we obtained the result after the follow up study follows. 1. Obwegeser II method is considered to move the distal segment passively when surgical correction of severe open bite correction and large amount of set back above 15mm is needed. 2. In one case that has more change of condylar position after operation, documented immediate post-operative relapse have been occurred 3. In the others that have adequate control of condylar position, passive set back and firm skeletal fixation, more functional and esthetic improvement and more post-operative stability has been achieved

  • PDF

POSTOPERATIVE POSITIONAL CHANGE OF CONDYLE AFTER BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY ASSOCIATED WITH MANDIBULAR ASYMMETRY (하악골 비대칭 환자의 양측성 하악골 시상분할 골절단술 후 하악과두의 위치 변화)

  • Lee, Sung-Keun;Kim, Kyung-Wook;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.5
    • /
    • pp.359-367
    • /
    • 2004
  • Purpose: After the surgical correction with sagittal split ramus osteotomy, the position of the mandibular condyle in the glenoid fossa and the proximal segment of the mandible change because of bony gap between proximal and distal segment, especially in case of mandibular setback asymmetrically. In this study, positional changes in the condyle and proximal segment after BSSRO were estimated in the mandibular asymmetry patient by analyzing the in submentovertex view and P-A cephalogram for identification of ideal condylar position during surgery. Patients and Methods: The 20 patients were selected randomly who visit Dankook Dental Hospital for mandibular asymmetry. Bilateral sagittal split ramus osteotomy with rigid fixation was performed and P-A cephalogram and submentovertex view was taken at the time of preoperative, immediate postoperative, 3 month postoperative period. Results: Intercondylar length and transverse condylar angle was increased due to inward rotation of proximal segment and anteromedial rotation of lateral pole of condyle head. The condylar position had a tendency to return to the preoperative state and after 3 months return up to about half of the immediate post-operative changes, and all the results showed more changes in asymmetry patient and deviated part of the mandible. Conclusion: Based on all these results above, surgeon should make efforts to have a precise preoperative analysis and to have a ideal condylar position during rigid fixation after BSSRO.

A CEPHALOMETRIC AND PANORAMIC ANALYSIS OF THE CHANGES OF THE CONDYLAR POSITION AFTER ORTHOGNATHIC SURGERY (하악전돌증 환자의 악교정 수술후 하악과두의 위치변화에 대한 연구)

  • Kang, Young-Ki;Kim, Jong-Ryoul;Yang, Dong-Kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.4
    • /
    • pp.411-419
    • /
    • 2000
  • Purpose: This study was aimed at analysis of the changes in the condyle position in subjects with mandibular setback osteotomies Method: Twenty patients were evaluated retrospectively for their changes in the condyle position who underwent surgical mandibular setback using bilateral sagittal split osteotomies with a manual condyle repositioning technique and rigid fixation. The cephalometric and panoramic analysis was performed preoperatively, 1 week, 6 months, and 1 year postoperatively. And postoperative noise, temporomandibular joint pain, and mouth opening were clinically examined 2 months, 4 months, 6 months, 8 months, 10 months, and 12 months postoperatively. Result: The condyles rotated posteriorly and laterally immediately after surgery, and they returned to the preoperative position during follow-up period but it is not significant. The statistical analysis (Paired t-test) showed no significant effects in postsurgical stability. The changes in the condyle position didn't have a significant harmful influence on temporomandibular joint disorder. Conclusion: A careful surgical mandibular setback using manual condyle repositioning and fixation technique will move condyle minimally and that will decrease the relapse and temporomandibular joint disorder.

  • PDF

DISTRACTION OSTEOGENESIS OF THE MIDFACE WITH A RIGID EXTERNAL DISTRACTOR (RED) (강성 외장형 신장기(Rigid External Distractor)를 이용한 중안면부의 골신장술)

  • Oh , Jung-Hwan;Alexander, Kuebler.;Zoeller, Joachim E.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.2
    • /
    • pp.161-164
    • /
    • 2002
  • In recent, distraction osteogenesis has been used to correct skeletal malformations and discrepancies in the craniofacial area. It also seems to be considered as an alternative in the treatment of severe midfacial hypoplasia. There are some types of distractors for midfacial distraction such as subcutaneous distractors and rigid external distractors. We used a rigid external distractor for correction (RED) of craniofacial hypoplasia. Seven patients underwent a midfacial distraction osteogenesis with a rigid external distractor between April 2000 and July 2001. Three patients suffered from Apert's syndrome, three patients from Crouzon's syndrome, and one patient suffered from midfacial hypoplasia due to midfacial radiotheraphy during childhood. On average, the mean distance of distraction was 19.8mm ($10{\sim}25mm$) and the distraction lasted for 24 days. The patients showed no severe complications like infections, optic disturbance, or wrong distraction vectors. One patient complained pain on the site of the occipital fixation of the distractor. In one patient who underwent subtotal craniectomy 3 months before Le Fort III distraction, the distractor was dislocated as the cranial bone was too weak to support the distractor. This report reveals that the application of rigid external distractor and transfacial pull results in an exact control of the distraction vectors and an excellent correction of midfacial hypoplasia without any severe complications.

CLINICAL STUDY ON SURGICAL MANAGEMENT OF MANDIBULAR CONDYLAR FRACTURES (하악 과두 골절의 외과적 처치에 관한 임상적 연구)

  • Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.2
    • /
    • pp.167-180
    • /
    • 1997
  • 79 surgically managed mandibular condylar fracture patients included the 25 patients treated with Dr, Nam's method were analysed the postoperative resluts in Oral and Maxillofcial Surgery, School of Dentistry, Wonkwang University since 1993 to 1995. Mean patient's age is 32.5 years (range, 8 to 65 years), and follow-up periods were a minimum of 3 months to 28 months. 19% condylar fractures were associated with mostly symphysis portion. According to the patient's age, severity of condylar fractures, clinical signs and symptoms, radiographic findings, treatmenet plans had been performed. Rigid fixation have performed greatly, and then fragment removal of fractured mesial pole of proximal segment of the condylar and little cases of reshaping and eminoplasty and lag screw have been applied. Two cases of the both condylar resorption and deviated condyle posteriorly in Dr. Nam's method. None of infection or necrosis signs of treated condyle surgically. In my opinion, whenever possible, displaced condylar fracture can be managed surgically with rigid fixation, but not Dr. Nam's method. Usually if perform the surgical management of condylar fractures you should maintain maxillomandibular fixation for 2 weeks, or more and has to follow-up functional mandibular exercise should be kept continuously.

  • PDF

A Study On Shape Design of Implant Systems For Bone Fracture Operations By Using Finite Element Method (유한요소법을 이용한 골절치료용 임플란트 시스템 형상설계에 관한 연구)

  • Cho, Ji-Hyun;Seo, Keum-Hee;Seo, Tae-il
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.425-432
    • /
    • 2012
  • This paper investigates shape design processes of two implant systems for bone fracture treatment ; Bone plate and Interlocking nail system. These systems can directly fix fractured human bones by surgical operations. The bone plates consist of various shaped plates and implant screws for fixation of fractured human bones with various manual instruments allowing to handle them. The material corresponds to titanium alloy Ti6Al4V because it is harmless material for human body as well as significantly rigid. This system has to be suitably rigid as well as manually bended in orthopedic surgery operations. The Interlocking nail system is a kind of nail implanted inside fractured human bones. The shapes of these systems have to be suitably designed in order to endure various loads as well as avoid any damages. If various shaped prototypes would be fabricated and tested to design the optimal shapes, optimal shapes could be obtained but very long time and expensive costs must be required. In this paper finite element method was applied into these systems. Under various boundary conditions a series of structural analysis was conducted by using ANSYS. Finally important shape factors could be determined on the basis of the analysis results.