• 제목/요약/키워드: rheological parameter

검색결과 74건 처리시간 0.022초

MR유체 엔진마운트의 성능해석 (Performance Analysis of a Magneto-Rheological Fluid Engine Mount)

  • 안영공;김원철;양보석
    • 소음진동
    • /
    • 제8권3호
    • /
    • pp.457-466
    • /
    • 1998
  • This paper evaluates the performance of a Magneto-Rheological (MR) fluid mount. The mount incorporates MR fluid in a conventional fluid mount to open and closed the inertia track between the fluid chambers of the mount. It is shown that such switching of the inertia track improves the mount's isolation effect, by eliminating the large transmissibility peak that commonly exists at frequencies higher than the notch frequency for conventional fluid mounts. The switching frequencies of the MR mount is evaluated, based on the parameters of the mount. A simple control scheme for switching the mount between the open and closed states is proposed, and the performance of the controlled mount is compared with conventional mounts. A sensitivity analysis is conducted to evaluate the effect of parameter errors in estimating the switching frequencies and mount performance. The results show that the switching frequencies can be accurately determined from mount parameters that are easily measured or estimated.

  • PDF

Pseudomonas elodea에 의해서 생산된 Gellan gum과 Agar의 rheology 특성 비교연구 (Study on rheological characterization of Gellan gum Produced by Pseudomonas elodea -Comparative Studies on Rheological Characterization of Gellan gum and Agar-)

  • 권혜숙;구성자
    • 한국식품조리과학회지
    • /
    • 제4권1호
    • /
    • pp.17-26
    • /
    • 1988
  • The polysaccharide produced by pseudomonas elodea, Gellan gum, was rheologically characterized, compared with agar. Rheological properties were determined from the change in the value of intrinsic viscosity with the pH and salt concentration. At the range of pH 2∼ll and salt 0∼0.16M KC1, the intrinsic viscosity of Gellan gum ranged from 8.8 to 21.2dl/g and agar ranged from 1.97 to 11.46d1/g. In the absence of salt, the intrinsic viscosity of Gellan gum increased as the pH of solution increased up to neutral pH then decreased slightly at alkaline pH, whearas the intrinsic viscosity of agar increased as the pH of solution increased up to pH 9 then decreased slightly. Intrinsic viscosity of Gellan gum and agar decreased with an increase in salt concentration. The chain stiffness parameter for the Gellan gum was 0.033. The overlap parameter of Gellan gum and agar were 0.047g/dl and 0.087g/dl, respectively. Gellan gum and agar were shear rate dependent or pseudoplastic. The yield stress and proportionality constant of Gellan gum increased slightly as the concentration increase, on the other hand, the shear index of Gellan gum showed a maximum at 0.75g/dl and gradually decreased as the concentration increase. The apparent viscosity of Gellan gum and agar decreased as the temperature increase. A lower concentration of the divalent cations calcium and magnesium is required to obtain maximum gel strength than for the monovalent cations sodium and potassium.

  • PDF

유색 대두수집종의 특성연구 제III보 유색 대두수집종의 화학적 조성과 특성 변이 (Basic Studies on the Native Colored-Soybean Cultivars III. Variations and Preformances in Chemical Composition and Textural Property in Seeds of Collected Colored-Soybean Cultivars)

  • 구자옥;이종욱;이영만
    • 한국작물학회지
    • /
    • 제28권3호
    • /
    • pp.345-350
    • /
    • 1983
  • 일정한 재배조건에서 생산된 38종의 유색 대두종실을 공시하여 종실의 화학적 조성과 Texturometer를 이용한 취반에 따른 물리적 변이를 분석 조사한 결과 다음의 경향을 알 수 있었다. 1. 대부분의 유색 대두는 황태에 대한 기존의 재래종 대두 분석결과보다 단백질과 지방의 함량이 낮고 상대적으로 탄수화물 함량이 높은 경향이었으나 종실중의 차이에 따른 종실성분의 변이는 일정하지 않았다. 2. 100립중이 25-30g인 대립군의 유색 대두종은 단백질, 지방 및 탄수화물의 함량에서 상대적으로 높은 변이계수를 나타내었다. 3. 유색 대두의 Texturometer curve에서는 Hardnes, Cohesiveness, Elasticity만 반응을 보였고, Hardness는 종실중에 의하여, 기타의 Parameter들은 종실중 자체에 의하여 달라서 동일한 특성이나 종실중 내에서도 품종에 따라 유의적 차이를 보였다. 4. Hardeness와 Elasticity는 낮은 C. V치를, Cohesiveness와 Gumminess 및 Chewiness는 40% 이상의 높은 C.V.치를 나타내었다. 5. Hardness, Elasticity, Chewiness는 상호간에 정상관을 보이는 반면 이들과 Cohesiveness, Gumminess간에는 부의 상관을 보였다. 6. Hardness와 Elasticity는 탄수화물 함량과 정상관을 단백질 함량과는 역상관을 보였으며 Cohesiveness는 이들과 정반대의 경향을 나타내었다.

  • PDF

전기 유동유체를 함유하는 지능외팔보의 진동특성 및 제어 실험적 고찰 (Vibration Characteristics and Control of Smart Cantilever Beams Containing an Electro-Rheological Fluid An Experimental Investigation)

  • 최승복;박용군;서문석
    • 대한기계학회논문집
    • /
    • 제17권7호
    • /
    • pp.1649-1657
    • /
    • 1993
  • This paper reports on a proof-of-concept experimental investigation focused on evaluating the vibration characteristics and control of smart hollow cantilever beams filled with an electro-rheological(ER) fluid. The beams are considered to be of uniform viscoelastic materials and modelled as a viscously-damped harmonic oscillator. Electric field-dependent natural frequencies, loss factors and complex moduli are evaluated and compared among three different beams : two types of different volume fraction of ER fluid and one type of different particle concentration of ER fluid by weight. Modal characteristics of the beams are observed in both the absence and the presence of electric potentials. It is also shown that by constructing active control algorithm the removal of structural resonances and the suppression of tip deflection are obtained. This result provides the feasiblility of ER fluids as an active vibration control element.

"Cohesiveness of Hyaluronic Acid Fillers": Evaluation Using Multiple Cohesion Tests

  • Kyun Tae Kim;Won Lee;Eun-Jung Yang
    • Archives of Plastic Surgery
    • /
    • 제51권1호
    • /
    • pp.14-19
    • /
    • 2024
  • Background Hyaluronic acid fillers can be manufactured using various processes. They have multiple properties, including their concentration, degree of modification, and rheological data. Cohesion is one such property to evaluate gel integrity; however, there is no standardized method for calculating this parameter. This study aimed to evaluate different tests for calculating hyaluronic acid cohesion and discuss the importance of hyaluronic acid cohesion as a consideration when selecting fillers. Methods The cohesion levels of five different hyaluronic acid fillers with different rheological properties were evaluated and compared using the drop weight, compression, tack, and dispersion time tests. Results The cohesion tests yielded different results in the samples. Samples 2 and 4 showed approximately two times the number of droplets when compared with Sample 5 in drop weight test. Samples 1, 2, 3, and 4 were superior to Sample 5 in tack test. Samples 1, 2, and 3 showed cohesive appearances at 95 seconds in most cases in dispersion test. Rheological test results did not reflect the measures of cohesion. Conclusion Although there are no definite standardized tests to evaluate the cohesion of hyaluronic acid fillers, our proposed tests showed similar results for different hyaluronic acid filler products. Further studies are needed to evaluate the cohesion of hyaluronic acid fillers and determine the clinical use of this distinguishing characteristic for clinicians selecting the product of choice. Level of evidence statement: These data are Level IV evidence.

Numerical simulation of dynamic segregation of self-consolidating concrete (SCC) in T-box set-up

  • Hosseinpoor, Masoud;Khayat, Kamal H.;Yahia, Ammar
    • Computers and Concrete
    • /
    • 제20권3호
    • /
    • pp.297-310
    • /
    • 2017
  • A CFD software was used to simulate free surface flow of SCC in the T-Box test. In total, seven simulations were developed to study the effect of rheological parameters on the non-restricted flow performance of SCC in both horizontal and vertical directions. Different suspending fluids having five plastic viscosity values between 10 and 50 Pa.s, three yield stress values between 14 and 75 Pa, one density of $2500kg/m^3$, and one shear elasticity modulus of 100 Pa were considered for suspension of 178 spherical particles of 20-mm diameter and $2500kg/m^3$ density. The results of the simulations are found to correlate well to changes in rheological parameters of the suspending fluid. Plastic viscosity was shown to be the most dominant parameter affecting flowability and dynamic stability compared to the yield stress. A new approach was proposed to evaluate performability of SCC based on a trade-off between flowability and dynamic stability.

Parameters identification of fractional models of viscoelastic dampers and fluids

  • Lewandowski, Roman;Slowik, Mieczyslaw;Przychodzki, Maciej
    • Structural Engineering and Mechanics
    • /
    • 제63권2호
    • /
    • pp.181-193
    • /
    • 2017
  • An identification method for determination of the parameters of the rheological models of dampers made of viscoelastic material is presented. The models have two, three or four parameters and the model equations of motion contain derivatives of the fractional order. The results of dynamical experiments are approximated using the trigonometric function in the first part of the procedure while the model parameters are determined as the solution to an appropriately defined optimization problem. The particle swarm optimization method is used to solve the optimization problem. The validity and effectiveness of the suggested identification method have been tested using artificial data and a set of real experimental data describing the dynamic behavior of damper and a fluid frequently used in dampers. The influence of a range of excitation frequencies used in experiments on results of identification is also discussed.

항공기 엔진용 유체 마운트의 성능해석

  • 안영공
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 강연회 및 연구개발 발표회 논문집
    • /
    • pp.220-227
    • /
    • 1998
  • This paper evaluate the performance of a Magneto-Rheological (MR) fluid mount. The mount incorporates MR fluid in a conventional fluid mount to open and closed the inertia track between the fluid chambers of the mount. It is shown that such switching of the inertia track improves the mount's isolation effect, by eliminating the large transmissibility peak that commonly exists at frequencies higher than the notch frequency for conventional fluid mounts. The switching frequencies of the MR mount is evaluated, based on the parameters of the mount. A simple control scheme for switching the mount between the open and closed states is proposed, and the performance of the controlled mount is compared with conventional mounts. A sensitivity analysis is conducted to evaluate the effect of parameter errors in estimating the switching frequencies and mount performance. The results show that the switching frequencies can be accurately determined from mount parameters that are easily measured or estimated.

  • PDF

승용차용 연속가변 ER댐퍼의 성능연구 (Performance Investigation of a Continuously Variable ER Damper for Passenger Vehicles)

  • 김기선;장유진;최승복;정재천;서문석;여문수
    • 한국자동차공학회논문집
    • /
    • 제3권6호
    • /
    • pp.69-77
    • /
    • 1995
  • This paper presents performance investigation of a continuously variable ER(Electro-Rheological) damper for passenger vehicles. A dynamic model of the damper is formulated by incorporating electric field-dependent Bingham properties of the ER fluid. The Bingham properties are experimentally obtained through Couette type electroviscous measurement with respect to two different particle concentrations. The governing equation of the hydraulic model treating three components of fluid resistances;electrode duct flow, check valve flow and piston gap flow, is achieved via the bond graph method. A prototype ER damper is then designed and manufactured on the basis of parameter analysis. The damping forces of the system are experimentally evaluated by changing the intensity of the electric field, the particle concentration and the electrode gap.

  • PDF

ER유체를 이용한 스마트 평판의 진동모드 제어 (Vibration mode control of a smart plate containing electro-rheological fluid)

  • 정상봉;박용균;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.451-455
    • /
    • 1997
  • This paper presents vibration mode control of a smart plate containing electro-rheological (ER) fluid between elastic face layers. Following the composition of a silicone oil-based ER fluid, the ER fluid-embedded plate partitioned into four sections is constructed. Then, an extensive modal test is experimentally carried out to identify field-dependent modal parameters such as mode shapes and natural frequencies of the structure with respect to different are subjected to electric fields. The distilled results from the experiment exhibit that the ER fluid can be effectively employed in a continuous fashion to tune modal behaviors of the distributed parameter systems,

  • PDF