• 제목/요약/키워드: reverse total shoulder arthroplasty

검색결과 47건 처리시간 0.024초

Pathogenesis, evaluation, and management of osteolysis after total shoulder arthroplasty

  • Kunze, Kyle N.;Krivicich, Laura M.;Brusalis, Christopher;Taylor, Samuel A.;Gulotta, Lawrence V.;Dines, Joshua S.;Fu, Michael C.
    • Clinics in Shoulder and Elbow
    • /
    • 제25권3호
    • /
    • pp.244-254
    • /
    • 2022
  • Radiographic osteolysis after total shoulder arthroplasty (TSA) remains a challenging clinical entity, as it may not initially manifest clinically apparent symptoms but can lead to clinically important complications, such as aseptic loosening. A thorough consideration of medical history and physical examination is essential to rule out other causes of symptomatic TSA-namely, periprosthetic joint infection-as symptoms often progress to vague pain or discomfort due to subtle component loosening. Once confirmed, nonoperative treatment of osteolysis should first be pursued given the potential to avoid surgery-associated risks. If needed, the current surgical options include glenoid polyethylene revision and conversion to reverse shoulder arthroplasty. The current article provides a comprehensive review of the evaluation and management of osteolysis after TSA through an evidence-based discussion of current concepts.

The impact of modern airport security protocols on patients with total shoulder replacements

  • Michael D. Scheidt;Neal Sethi;Matthew Ballard;Michael Wesolowski;Dane Salazar;Nickolas Garbis
    • Clinics in Shoulder and Elbow
    • /
    • 제26권4호
    • /
    • pp.416-422
    • /
    • 2023
  • Background: Advancements in airport screening measures in response to 9/11 have resulted in increased false alarm rates for patients with orthopedic and metal implants. With the implementation of millimeter-wave scanning technology, it is important to assess the changes in airport screening experiences of patients who underwent total shoulder arthroplasty (TSA). Methods: Here, 197 patients with prior anatomic and reverse TSA completed between 2013 and 2020 responded to a questionnaire regarding their experiences with airport travel screening after their operation. Of these patients, 86 (44%) stated that they had traveled by plane, while 111 (56%) had not. The questionnaire addressed several measures including the number of domestic and international flights following the operation, number of false alarm screenings by the millimeter-wave scanner, patient body habitus, and presence of additional metal implants. Results: A total of 53 patients (62%) responded "yes" to false screening alarms due to shoulder arthroplasty. The odds of a false screening alarm for patients with other metal implants was 5.87 times that of a false screening alarm for patients with no other metal implants (P<0.1). Of a reported 662 flights, 303 (45.8%) resulted in false screening alarms. Greater body mass index was not significantly lower in patients who experienced false screening alarms (P=0.30). Conclusions: Patients with anatomic and reverse TSA trigger false alarms with millimeter-wave scanners during airport screening at rates consistent with prior reports following 9/11. Patient education on the possibility of false alarms during airport screening is important until improvements in implant identification are made. Level of evidence: IV.

Rapidly Progressive Osteonecrosis of the Humeral Head after Arthroscopic Bankart and Rotator Cuff Repair in a 66-Year Old Woman: A Case Report

  • Cho, Hyun IK;Cho, Hyung Lae;Hwang, Tae Hyok;Wang, Tae Hyun;Cho, Hong
    • Clinics in Shoulder and Elbow
    • /
    • 제18권3호
    • /
    • pp.167-171
    • /
    • 2015
  • Humeral head chondrolysis has been widely reported as a devastating complication after arthroscopic shoulder surgery; however little is known about post-arthroscopic humeral head osteonecrosis. We experienced a 66-year-old female patient with rapidly progressive osteonecrosis of the humeral head only seven months after arthroscopic Bankart and rotator cuff repair. The patient had no systemic risk factors for osteonecrosis. A satisfactory result was achieved with reverse total shoulder arthroplasty for severe humeral head destruction and an irreparable massive rotator cuff tear. Shoulder surgeons should be aware of such severe complication, perform routine radiographs, and pay close attention to the presence of constant pain or loss of motion after arthroscopic shoulder surgery.

Implant selection for successful reverse total shoulder arthroplasty

  • Joo Han Oh;Hyeon Jang Jeong;Yoo-Sun Won
    • Clinics in Shoulder and Elbow
    • /
    • 제26권1호
    • /
    • pp.93-106
    • /
    • 2023
  • Reverse total shoulder arthroplasty (RTSA) emerged as a new concept of arthroplasty that does not restore normal anatomy but does restore function. It enables the function of the torn rotator cuff to be performed by the deltoid and shows encouraging clinical outcomes. Since its introduction, various modifications have been designed to improve the outcome of the RTSA. From the original cemented baseplate with peg or keel, a cementless baseplate was designed that could be fixed with central and peripheral screws. In addition, a modular-type glenoid component enabled easier revision options. For the humeral component, the initial design was an inlay type of long stem with cemented fixation. However, loss of bone stock from the cemented stem hindered revision surgery. Therefore, a cementless design was introduced with a firm metaphyseal fixation. Furthermore, to prevent complications such as scapular notching, the concept of lateralization emerged. Lateralization helped to maintain normal shoulder contour and better rotator cuff function for improved external/internal rotation power, but excessive lateralization yielded problems such as subacromial notching. Therefore, for patients with pseudoparalysis or with risk of subacromial notching, a medial eccentric tray option can be used for distalization and reduced lateralization of the center of rotation. In summary, it is important that surgeons understand the characteristics of each implant in the various options for RTSA. Furthermore, through preoperative evaluation of patients, surgeons can choose the implant option that will lead to the best outcomes after RTSA.

Clinical and Radiological Results of Reverse Total Shoulder Arthroplasty Using a 25-mm Glenoid Baseplate

  • Lee, Ji Min;Kim, In Bo;Jung, Dong Wook
    • Clinics in Shoulder and Elbow
    • /
    • 제18권4호
    • /
    • pp.242-247
    • /
    • 2015
  • Background: The size of the baseplate used in reverse total shoulder arthroplasty (RTSA) tends to be larger than the average size of the glenoid in the Korean population. The mismatch between the sizes of the baseplate and the patient's glenoid may result in improper fixation of the glenoid baseplate. This in turn may lead to the premature loosening of the glenoid component. Thus, we evaluated the short-term results of using a 25-mm baseplate in RTSA. Methods: Seventeen patients with cuff tear arthropathy underwent RTSA with a 25-mm baseplate. The mean age of the patients was 70.1 years, and the mean follow-up period was 14.0 months. We evaluated clinical outcomes preoperatively and postoperatively: the range of shoulder motion, the American Shoulder and Elbow Surgeons (ASES) score, and the Korean Shoulder Society (KSS) score. Results: We found that the mean ASES score and KSS improved from 35.0 to 74.4 (p<0.001) and from 46.9 to 71.8 (p<0.001) with RTSA. The mean forward elevation and abduction, external rotation also improved from $78.6^{\circ}$ to $134.3^{\circ}$ (p<0.05) and from $66.6^{\circ}$ to $125.0^{\circ}$ (p<0.05), from $20.2^{\circ}$ to $28.4^{\circ}$ (p=0.43). Postoperative complications were seen in 12% of patients, but neither the loosening of the glenoid baseplate nor inferior scapular notching were observed. Conclusions: In sum, the results of using a 25-mm baseplate in RTSA were similar to those of previous reports. Even though the outcomes are those of a short-term follow-up, neither the loosening of the glenoid baseplate nor the scapular notching were observed.

Mid-term outcomes of bony increased offset-reverse total shoulder arthroplasty in the Asian population

  • Tankshali, Kirtan;Suh, Dong-Whan;Ji, Jong-Hun;Kim, Chang-Yeon
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.125-134
    • /
    • 2021
  • Background: To evaluate clinical and radiological outcomes of bony increased offset-reverse total shoulder arthroplasty (BIO-RSA) in the Asian population at mid-term follow-up. Methods: From June 2012 to August 2017 at a single center, 43 patients underwent BIO-RSA, and 38 patients with minimum 2 years follow-up were enrolled. We evaluated the clinical and radiological outcomes, and complications at the last follow-up. In addition, we divided these patients into notching and no-notching groups and compared the demographics, preoperative, and postoperative characteristics of patients. Results: Visual analogue scale, American Shoulder and Elbow Surgeons, University of California-Los Angeles Shoulder Scale, and Simple Shoulder Test scores improved significantly from preoperative (5.00, 3.93, 1.72, 3.94) to postoperative (1.72, 78.91, 28.34, 7.66) (p<0.05) outcomes. All range of motion except internal rotation improved significantly at the final follow-up (p<0.05), and the bone graft was well-incorporated with the native glenoid in all patients (100%). However, scapular notching was observed in 20 of 38 patients (53%). In the comparison between notching and no-notching groups (18 vs. 20 patients), there were no significant differences in demographics, radiological parameters, and clinical outcomes except acromion-greater tuberosity (AT) distance (p=0.003). Intraoperative complications included three metaphyseal fractures and one inferior screw malposition. Postoperative complications included ectopic ossification, scapular neck stress fracture, humeral stem relaxation, and late infection in one case each. Conclusions: BIO-RSA showed improved clinical outcomes at mid-term follow-up in Asian population. However, we observed higher scapular notching compared to the previous studies. In addition, adequate glenoid lateralization with appropriate humeral lengthening (AT distance) might reduce scapular notching.

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.

'MEMIARTHROPLASTY VS. TOTAL SMOULDER ARTHROPLASTY'

  • Bigliani Louis U.
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2002년도 아시아견관절학술대회
    • /
    • pp.7-7
    • /
    • 2002
  • Historically, the decision to perform a hemiarthroplasty (HHR) versus a total shoulder arthroplasty (TSA) is based on the status of the glenoid and the status of the soft tissues (rotator cuff). In disease processes where the glenoid articular cartilage is relatively well preserved such as avascular necrosis and complex proximal humerus fractures, most orthopaedists recommend performing a HHR while preserving the native glenoid articular surface. At the other end of the spectrum, if the glenoid has excessive bone loss or is unreconstructible, a HHR is the preferred procedure. In patients who have deficient so(t-tissues (rotator cuff) such as rotator cuff tear arthropathy and, occasionally, rheumatoid arthritis, a HHR is the procedure of choice. The indications for HHR in osteoarthritis remain somewhat controversial. There is mounting evidence that performing a HHR for osteoarthritis is inferior to TSA. Recent developments, or 'third generation techniques and materials', in shoulder arthroplasty are expected to improve the longevity of TSA, particularly the glenoid component. In addition, newer designs of reverse-ball prostheses are entering the market with promising early results in patients with deficient rotator cuff mechanisms.

  • PDF