• Title/Summary/Keyword: reverse current

Search Result 697, Processing Time 0.027 seconds

Feasibility of a two step microfiltration and reverse osmosis membrane system for reuse of tunnel wastewater (터널폐수 재이용을 위한 통합형 멤브레인 시스템의 적용)

  • Lee, Jae-Hyun;Jeong, Se-Uk;Kim, Young Mo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.779-785
    • /
    • 2013
  • This study investigated the applicability of a two step microfiltration(MF) and reverse osmosis(RO) membrane system for reuse of tunnel wastewater. In this two step process, the MF system first treated only micropollutants in tunnel wastewater such as suspended solids(SS) and heavy metals, achieving less than 0.2 NTU turbidity, less than 1.1 mg/L chemical oxygen demand($COD_{Mn}$) and less than 0.8 mg/L total manganese(Mn). The RO system then removed over 95 % of the remaining pollutnats and particles, resulting in less than 0.02 NTU turbidity, less than 0.5 mg/L chemical oxygen demand($COD_{Mn}$), less than 0.04 mg/L total nitrogen(T-N) and less than 0.01 mg/L total phosphorus(T-P). In particular, addition of an RO system could lead to markedly reduced high salt concentrations in tunnel wastewater, approaching almost zero. Thus, reclaimed water using the combined membrane system could satisfy current South Korean regulations concerning wastewater reuse(turbidity ${\leq}2.0$ NTU; T-N ${\leq}10mg/L$; T-P ${\leq}0.5mg/L$; Salinity ${\leq}250mg{\cdot}Cl/L$).

Research Trends and Prospects of Reverse Electrodialysis Membranes (역전기투석용 이온교환막의 연구동향 및 전망)

  • Hwang, Jin Pyo;Lee, Chang Hyun;Jeong, Yeon Tae
    • Membrane Journal
    • /
    • v.27 no.2
    • /
    • pp.109-120
    • /
    • 2017
  • The reverse electrodialysis (RED) is an energy generation system to convert chemical potential of saline water directly into electric energy via the combination of current derived from a redox couple electrolyte and ionic potential obtained when cation ($Na^+$) and anion ($Cl^-$) pass through cation exchange membrane (CEM) and anion exchange membrane (AEM) into fresh water, respectively. Ion exchange membrane, a key element of RED system, should satisfy requirements such as 1) low swelling behavior, 2) a certain level of ion exchange capacity, 3) high ion conductivity, and 4) high perm-selectivity to achieve high power density. In this paper, research trends and prospects of ionomer materials and ion exchange membranes are dealt with.

[ $Ca^{2+}$ ]-dependent Long-term Inactivation of Cardiac $Na^+/Ca^{2+}$ Exchanger

  • Lee, Jee-Eun;Kang, Tong-Mook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.11 no.5
    • /
    • pp.183-188
    • /
    • 2007
  • Using BHK cells with stable expression of cardiac $Na^+/Ca^{2+}$ exchanger(BHK-NCX1), reverse mode(i.e. $Ca^{2+}$ influx mode) of NCX1 current was recorded by whole-cell patch clamp. Repeated stimulation of reverse NCX1 produced a cytosolic $Ca^{2+}$-dependent long-term inactivation of the exchanger activity. The degrees of inactivation correlated with NCX1 densities of the cells and were attenuated by reduced $Ca^{2+}$ influx via the reverse exchanger. The inactivation of NCX1 was attenuated by(i) inhibition of $Ca^{2+}$ influx with reduced extracellular $Ca^{2+}$, (ii) treatment with NCX1 blocker($Na^{2+}$), and (iii) increase of cytoplasmic $Ca^{2+}$ buffer(EGTA). In BHK-NCX1 cells transiently expressing TRPV1 channels, $Ca^{2+}$ influx elicited by capsaicin produced a marked inactivation of NCX1. We suggest that cytoplasmic $Ca^{2+}$ has a dual effect on NCX1 activities, and that allosteric $Ca^{2+}$ activation of NCX1 can be opposed by the $Ca^{2+}$-dependent long-term inactivation in intact cells.

NUCLIDE SEPARATION MODELING THROUGH REVERSE OSMOSIS MEMBRANES IN RADIOACTIVE LIQUID WASTE

  • LEE, BYUNG-SIK
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.859-866
    • /
    • 2015
  • The aim of this work is to investigate the transport mechanism of radioactive nuclides through the reverse osmosis (RO) membrane and to estimate its effectiveness for nuclide separation from radioactive liquid waste. An analytical model is developed to simulate the RO separation, and a series of experiments are set up to confirm its estimated separation behavior. The model is based on the extended Nernst-Plank equation, which handles the convective flux, diffusive flux, and electromigration flux under electroneutrality and zero electric current conditions. The distribution coefficient which arises due to ion interactions with the membrane material and the electric potential jump at the membrane interface are included as boundary conditions in solving the equation. A high Peclet approximation is adopted to simplify the calculation, but the effect of concentration polarization is included for a more accurate prediction of separation. Cobalt and cesium are specifically selected for the experiments in order to check the separation mechanism from liquid waste composed of various radioactive nuclides and nonradioactive substances, and the results are compared with the estimated cobalt and cesium rejections of the RO membrane using the model. Experimental and calculated results are shown to be in excellent agreement. The proposed model will be very useful for the prediction of separation behavior of various radioactive nuclides by the RO membrane.

Rapid and Specific Detection of Apple stem grooving virus by Reverse Transcription-recombinase Polymerase Amplification

  • Kim, Nam-Yeon;Oh, Jonghee;Lee, Su-Heon;Kim, Hongsup;Moon, Jae Sun;Jeong, Rae-Dong
    • The Plant Pathology Journal
    • /
    • v.34 no.6
    • /
    • pp.575-579
    • /
    • 2018
  • Apple stem grooving virus (ASGV) is considered to cause the most economically important viral disease in pears in Korea. The current PCR-based methods used to diagnose ASGV are time-consuming in terms of target detection. In this study, a novel assay for specific ASGV detection that is based on reverse transcription-recombinase polymerase amplification is described. This assay has been shown to be reproducible and able to detect as little as $4.7ng/{\mu}l$ of purified RNA obtained from an ASGV-infected plant. The major advantage of this assay is that the reaction for the target virus is completed in 1 min, and amplification only requires an incubation temperature of $42^{\circ}C$. This assay is a promising alternative method for pear breeding programs or virus-free certification laboratories.

Cost Estimation and Validation based on Natural Language Requirement Specifications

  • So Young Moon;R. Young Chul Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.218-226
    • /
    • 2023
  • In Korea, we still use function point based cost estimations for software size and cost of a project. The current problem is that we make difficultly calculating function points with requirements and also have less accurate. That is, it is difficult for non-experts to analyze requirements and calculate function point values with them, and even experts often derive different function points. In addition, all stakeholders strongly make the validity and accuracy of the function point values of the project before /after the development is completed. There are methods for performing function point analysis using source code [1][2][3][4] and some researchers [5][6][7] attempt empirical verification of function points about the estimated cost. There is no research on automatic cost validation with source code after the final development is completed. In this paper, we propose automatically how to calculate Function Points based on natural language requirements before development and prove FP calculation based on the final source code after development. We expect validation by comparing the function scores calculated by forward engineering and reverse engineering methods.

Reuse of reverse osmosis membranes for wastewater treatment (Beni Saf Water Company)

  • Khadidja Benyahia;Mouhssin Khiari;Mourad Berrabah
    • Membrane and Water Treatment
    • /
    • v.15 no.4
    • /
    • pp.153-162
    • /
    • 2024
  • The current research project focuses on the feasibility of recycling and reusing utilized osmosis membranes from the Beni Saf water seawater desalination station in the province of Ain Temouchent. The composite Reverse Osmosis (RO) membrane, which is referenced BW30-400-FR and manufactured by Dow Filmtec TM, is used for all the tests. Three solvents are tested: potassium permanganate (KMnO4), sodium hydroxide (NaOH), hydrogen peroxide (H2O2), and the mixture of NaOH with KMnO4 for the degradation of the active layer of the RO membrane. A frontal filtration of wastewater using these modified membranes was carried out. An analysis of the physicochemical properties of the filtrate was performed using a spectrophotometer. The results of the frontal filtration performed under perpendicular pressure using a filtration ramp show that the membranes immersed in the NaOH and KMnO4 mixture for 24 hours produced a higher hydraulic flux compared to those immersed in NaOH and H2O2. At the end of the proposed treatment, the samples are analyzed by scanning electron microscopy (SEM) in addition to analyzing the clogging powder by EDX. The obtained results show the effectiveness of the proposed treatment for the degradation of the active layer in order to transform it into microfiltration and/or ultrafiltration.

Zero-Current-Switching in Full-Bridge DC-DC Converters Based on Activity Auxiliary Circuit

  • Chu, Enhui;Lu, Ping;Xu, Chang;Bao, Jianqun
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.353-362
    • /
    • 2019
  • To address the problem of circulating current loss in the traditional zero-current switching (ZCS) full-bridge (FB) DC/DC converter, a ZCS FB DC/DC converter topology and modulation strategy is proposed in this paper. The strategy can achieve ZCS turn on and zero-voltage and zero-current switching (ZVZCS) turn off for the primary switches and realize ZVZCS turn on and zero-voltage switching (ZVS) turn off for the auxiliary switches. Moreover, its resonant circuit power is small. Compared with the traditional phase shift full-bridge converter, the new converter decreases circulating current loss and does not increase the current stress of the primary switches and the voltage stress of the rectifier diodes. The diodes turn off naturally when the current decreases to zero. Thus, neither reverse recovery current nor loss on diodes occurs. In this paper, we analyzed the operating principle, steady-state characteristics and soft-switching conditions and range of the converter in detail. A 740 V/1 kW, 100 kHz experimental prototype was established, verifying the effectiveness of the converter through experimental results.

Current Source Type Pulse Generator with Improved Output Voltage Waveform for High Voltage Capacitively Coupled Plasma System (고전압 용량성 결합 플라즈마 시스템의 개선된 전압 파형 출력을 위한 펄스 전류 발생장치 회로)

  • Chae, Beomseok;Min, Juhwa;Suh, Yongsug;Kim, Hyunbae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.153-160
    • /
    • 2019
  • This study proposes a current source-type pulse generator to improve output voltage and current waveforms under a capacitively coupled plasma (CCP) system. The proposed circuit comprises two parallel-connected current source-type converters. These converters can satisfy the required output waveforms of plasma processing. The parallel-connected converters operate without reverse current fault by applying a time-delay control technique. Conventional voltage source converters based on pulse power supply exhibit drawbacks in short-circuit current, and problems occur when they are applied to a CCP system. The proposed pulse power supply based on a current source converter fundamentally solves the short-circuit current problem. Therefore, this topology can improve the voltage and current accuracy of a CCP system.

A Study On the Retention Time Distribution with Plasma Damage Effect

  • Yi Jae Young;Szirmay Laszlo;Yi Cheon Hee
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.460-462
    • /
    • 2004
  • The control of the data retention time is a main issue for realizing future high density dynamic random access memory. There are several leakage current mechanisms in which the stored data disappears. The mechanisms of data disappear is as follow, 1 )Junction leakage current between the junction, 2) Junction leakage current from the capacitor node contact, 3)Sub-threshold leakage current if the transfer transistor is affected by gate etch damage etc. In this paper we showed the plasma edge damage effect to find out data retention time effectiveness. First we measured the transistor characteristics of forward and reverse bias. And junction leakage characteristics are measured with/without plasma damage by HP4145. Finally, we showed the comparison TRET with etch damage, damage_cure_RTP and hydrogen_treatment. As a result, hydrogen_treatment is superior than any other method in a curing plasma etch damage side.

  • PDF