• Title/Summary/Keyword: reverberation

Search Result 489, Processing Time 0.034 seconds

The effect of a slat ceiling on the acoustics of a small performance space (슬랫천장이 소규모실의 음향에 미치는 영향)

  • Oh, Yedam;Lee, Hyojin;Jeong, Daeup
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.363-368
    • /
    • 2018
  • Recently a slat type ceiling is widely used in various spaces, such as music performance spaces and concourse of airport and a general reception area of a building. However, it is hard to find a proper design guideline or material useful in designing such spaces, due to the lack of relevant researches on the effect of a slat ceiling on room acoustics. The present work investigated the effect of a slat type ceiling using a physical scale model method. A 1/20 scale model of a small shoe-box type music performance hall was built and a slat ceiling with different configurations was installed. 6 cases of different ceiling configurations were considered with the combination of 2 slat ceiling height cases and 3 distance cases between slats. The effect of a slat ceiling on the acoustics of a room was evaluated by measuring reverberance($T_{30}$), intelligibility and clarity($D_{50}$ and $C_{80}$), and loudness(G and $G_{80}$).

Acoustic Properties of Three-room Coupled System by Connected Two Apertures (개구부로 연결된 3중 커플룸의 음향특성)

  • Na, Hae Joong;Lim, Byoung-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.340-349
    • /
    • 2016
  • A coupled room system consists of adjacent rooms and apertures where the sound energy is exchanged between the two rooms. Acoustically, a coupled room system shows a non-exponential decay profile. Most of the related researches have been to analyze the acoustic properties of two-room coupled system so far whereas three-room coupled system were seldom studied. In this regard, this paper aims to analyse the distribution of sound pressure level, sound decay curve of three-room coupled system and sound energy flow between them by using the acoustic diffusion model and to further verify them through experiments. Firstly, the sound pressure level distribution and mean sound pressure level in the steady-state condition are analyzed at various frequencies and source locations. Good agreements are observed in both experiments and analysis results. Secondly, two double slope effect quantifiers of sound attenuation, LDT/EDT and LDT/T10 are compared at various frequencies and for different source locations. The result indicates that LDT/T10, less affected by the early reflection patterns than LDT/EDT, is more suitable to the analysis and experiments of a multi-slope sound decay curve. Lastly, the sound energy flow in each room is analyzed based on the acoustic diffusion model. After the early decay stage, the sound energy is observed to flow from the room with a long reverberation time to the room with a short one.

Feasibility Study on Surface Microcrack Detection of the Steel Wire Rods Using Electromagnetic Acoustic Resonance (전자기 음향 공진을 이용한 강선의 표면 미세 결함 탐상 타당성 연구)

  • Heo, Taehoon;Cho, Seung Hyun;Ahn, Bongyoung;Lim, Zhong Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • The surface microcrack over a few tens of micrometers is one of severe problems of a steel wire rod to lead to the failure of the final products, so the method to evaluate crack depth has been required to develop. This work investigates the feasibility of electromagnetic acoustic resonance (EMAR) for this problem. EMAR is the method for measurement of resonant features using electromagnetic acoustic transducer (EMAT). Generally, EMAR is sensitive to small variation of the structures and easy to apply it to the industrial field because of the feature of noncontact measurement. Through several EMAR experiments, the change of the resonant frequencies and attenuation in reverberation has been observed. The results confirms that the surface cracks of around 100 micrometer depth can be detected successfully with the present method.

Measurement and Evaluation of the Acoustic Performance in the Royal Palace Buildings of Joseon Dynasty - Focused on Pyeonjeon and Chimjeon - (조선 궁궐 건축물의 음향성능 측정 및 평가 - 편전 및 침전을 중심으로 -)

  • Kim, Nam-Wook;Kim, Myung-Jun;Han, Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1269-1280
    • /
    • 2009
  • This study was performed to construct sound performance DB of royal palace buildings and to examine the special quality more scientifically. Research target of royal palace were Changdeokgung and Gyeongbokgung. Sound insulation performance between the adjacent room and facade, room acoustics of Pyeonjeon and Chimjeon which is representative building in royal palace were examined through field measurement. Measured values of RT($T_{mf}$) at Pyeonjeon were 0.78 sec. and 1.03 sec. in Seonjeongjoen and Sajeongjoen, respectively. The RTs of both Pyeonjeon buildings were estimated suitable for speech and lecture considering their volume. The RT($T_{mf}$)s at Chimjeon were measured in range of 0.29~0.55 sec. This meant that the acoustic energy in rooms was decreased by sound transmission through mulberry paper(Hanji) of traditional windows and doors. As a sound insulation performance, the single-number quantities($D_{ls,2m,nT,w}$) of the building facades in Pyeonjeon and Chimjeon were measured 4~20 dB. Also the single-number quantities($D_{p,w}$) between the adjacent rooms in Chimjeon were measured 3~18 dB. Sound insulation performance of traditional building elements such as window and door depended strongly on their layers and area.

Optimum Welding Position between Shell and Cylinder based on SEA (SEA 를 이용한 쉘과 실린더의 최적 용접 조건)

  • Ahn, Byoung-Ha;Lee, Jang-Woo;Jeon, Simon;Yang, Bo-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.258-264
    • /
    • 2012
  • The overall aim of this paper is to determine coupling loss factor of welding point between shell and cylinder using loss factor and structural loss factor. For this purpose, two kinds of loss factor were adopted. One is loss factor of each sub structure, another is structural loss factor based on the complex welded or assembled structure. Using these two parameters, it is possible to derive the coupling loss factor which represents characteristic condition of SEA theory. Coupling loss factor of conjunction in complex structure was expressed as power balance equation. The derived equation for a coupling loss factor has been simplified on the assumption of one way (uni-directional) power flow between multi-sub structures. Using these conditions, it is possible to find the equation of coupling loss factor expressed as above two loss factors. To check the effectiveness of above equation, this paper used two-stage application. The first approach was application between simple cylinder and shell. The next was adopted rotary compressor. Rotary compressor has three main conjunctions between shell and internal vibration part. This equation was applied to find out the optimum welding point with respect to reduce the noise propagation. It shows the effective tool to evaluate the coupling loss factor in complex structure.

  • PDF

A Correlation Analysis between the Airtightness and Sound Insulation Performance on the Opening Spaces of Han-style Windows (한식 창호의 개구 면적에 따른 기밀 및 차음 성능간 상관성 연구)

  • Lee, Ju-Yeob;Jang, Hyeon-Chung;Lee, Tai-Gang;Song, Min-Jeong;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.87-95
    • /
    • 2014
  • The purpose of this study is to evaluate the correlation coefficients between the airtightness and sound insulation performance of Han-style windows in New Han-ok. To achieve these goals, field measurements were accomplished in 18 bedrooms of 16 Han-oks in which actual residents were living, and then lab measurements were proceeded in the reverberation lab for evaluating the sound insulation performance. Followings are results. The results of the correlation analysis between the airtightness(Air change per hour at 50 Pa, ACH50) and sound insulation performance(Sound reduction index, Rw) in bedrooms of actual Han-oks, it was found that there were no significant correlation between two evaluating values. On the other hand, it was analyzed that the correlation coefficients of total 24 structures(double casement windows, single casement window, casement and sliding windows, single sliding window, 6 types per each structure) were located on 0.6757 exponentially and 0.4154 lineary in the lab evaluating conditions. But, The results of evaluating 4 structure classificatorily, it was found that there were high correlation coefficients(0.8665~0.9273 at ACH50, 0.8414~0.9346 at Rw). These results were signified that the correlation coefficients were changed according to the each structure and case by case analysis were necessary at the same time.

Room Acoustic Design in International Convention Center Jeju (제주국제컨벤션센터 컨퍼런스홀의 건축음향 설계)

  • 주현경;오양기;두세진;김하근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.802-807
    • /
    • 2003
  • International Convention Center Jeju(ICCJ) was planed and built for accommodating a variety of conventional and exhibitional activities. For a better flexibility of operation, almost all rooms in ICCJ are designed to be subdivided Into a couple of small rooms with installation of movable partition walls. Architectural and acoustical design should be deliberatively and cooperatively undertaken to cope with such a complex condition. Conference hall, the largest room in ICCJ, has a capacity of 5000 seats who:1 used as a whole. It could be divided into 3 halls, one with 2000 pre-installed seats on slanted floor, up/down removable stage and its settings above, and the other 2 flat rooms with no seats installed. A devided hall with pre-installed seats and stage is designed for a multi-use auditorium. Almost all surfaces except ceilings adjacent to the stage are sound absorptively treated, in regard to extensive use of sound reinforcement systems. Its reverberation time 1.65 sec without audience, which is roughly correspond to 1.50 sec with fully occupied audience. When there is a need for a larger room, all the partition wail Is removed and the hall could be used as a whole. Exhibition hall is located in the first floor of ICCJ. Absorption and softness are needed for the hat 1 because exhibition behavior has something noisy features. Perforated MDF panels with porous materials and air space in the back groundare adopted for the walls. There are one large, two medium, and several small convention rooms in ICJJ. The room are also acoustically designed for maximum flexibility with no defects soundwisely.

  • PDF

REVERBERATION MAPPING OF PG 0934+013 WITH THE SOUTH AFRICAN LARGE TELESCOPE

  • Park, Songyoun;Woo, Jong-Hak;Jeon, Yiseul;Park, Dawoo;Romero-Colmenero, Encarni;Crawford, Steven M.;Barth, Aaron;Pei, Luiyi;Choi, Changsu;Hickox, Ryan;Sung, Hyun-Il;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.68.2-68.2
    • /
    • 2016
  • We present the variability and time lag measurements of PG 0934+013 based on the photometric and spectroscopic monitoring campaign over two years. We obtained 46 epochs of data from the spectroscopic campaign, which was carried out using the South African Large Telescope with 1 week cadence over two sets of 4 month-long observing period, while we obtained 80 epochs of B band data from the campaign. Due to the six month gap between two campaigns, we separately measured the time lag of the $H{\beta}$ emission line by comparing the emission line light curve with the B band continuum light curve using the cross-correlation function techniques. We determined the time lags and black hole mass.

  • PDF

A Study for economic improvement of sound image localization and dead zone using computer simulations (컴퓨터 시뮬레이션을 이용한 음의 사각지역 및 음상의 경제적 개선방안 연구)

  • Ko, Eun-Ji;Lee, Hyun-Soo;Lee, Kyung-Ryang;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.703-708
    • /
    • 2011
  • In this paper, most of the church except for a large church has accommodated many audience to install a balcony floor in a small space. therefore, dead zone and dislocated sound image localization is made due to this under-balcony seats. This paper propose that the problems of dead zone and dislocated sound image localization could be solved using computer simulation in the view of practical side. The economical computer simulation tool, Mapp online that can be found easily was used to the specified church. Installation a sub speaker for dead zone and -10 dB power control of the sub speaker to main speaker power for dislocated sound image localization was proposed. Computer simulation result shows that the value of definition for area was improved from "Normal" to "Very Good" which means about 52% improvement.

A Study on The Modulation Method for Low Power Communication in Underwater Sensor Network (수중 센서 네트워크에서 저전력 통신을 위한 변조기법의 적용성 연구)

  • Jang, Chul-Hee;Han, Jeong-Woo;Kim, Ki-Man;Lee, Seong-Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6B
    • /
    • pp.689-696
    • /
    • 2011
  • In this paper, we propose the result of PSSK(Phase Silence Shift Keying) modulation scheme that is mixed PSK(Phase Shift Keying) modulation and PPM(Pulse Position Modulation) method. The performance of underwater communication systems are influenced underwater channel characteristics. In particular, delay spread can make ISI(Inter Symbol Interference) because of reverberation and multi path. It degrade the performance of the communication system. Also underwater sensor networks consider about power efficient due to the particularities of their operating environment. PSSK modulation method transmit two orthogonal symbol and using silence period in a period so it can reduce the power. Increasing the distance of between modulation symbols, to enhance the performance of BER(Bit Error Rate) as well as to improve power efficient. The result of sea trial, QPSK modulation BER is $3.19{\times}10^{-1}$ and PSSK modulation BER is $2.89{\times}10^{-1}$.