• Title/Summary/Keyword: retentive force

Search Result 48, Processing Time 0.02 seconds

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

  • Lee, Eunjee;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.14-21
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS. The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in overdenture sample and the abutment keeper in a mandibular model. Dislodging forces were applied to the overdenture samples (50.0 mm/min) in 3 directions. The loading was repeated 10 times in each direction. The values of dislodging force were analyzed statistically using SPSS at 95% level of confidence. RESULTS. The retentive force of group 2 was greater than that of group 1 in both types of attachment in every direction (P < .05). Oblique retentive force of flat type magnetic attachment was higher than that of cushion type attachment in both groups (P < .05). In group 1, oblique retentive force showed the highest and anterior-posterior retentive force showed the lowest value in both attachment types (P < .05). In group 2, both types of attachment showed the lowest retentive force with anterior-posterior direction of dislodging force (P <.05). CONCLUSION. Proper retentive properties for implant overdenture were obtained, regardless of the number and type of magnetic attachment. In both types of magnetic attachment, the greater retentive force was attained with more implants. Oblique retentive force of flat type magnetic attachment was greater than that of cushion type. Among all subgroups, anterior-posterior retentive force was the lowest among three different directions of dislodging force.

THE COMPARISON OF INITIAL RETENTIVE FORCE IN DIFFERENT DOUBLE CROWN SYSTEMS

  • Kwon, Ho-Beom;Roh, Yoon-Ho;Lee, Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.677-682
    • /
    • 2006
  • Statement of problem. Various double crown systems have been used with removable partial dentures in the clinical field. Although retentive force between inner and outer crown are affected by several factors, differences between the retentive forces of different double crown system types are expected. Purpose. The purpose of this study was to evaluate the initial retentive force of outer crowns fabricated by the conventional casting technique in conus and hybrid double crowns. Material and methods. Ten double crowns were fabricated. The groups were as follows. Group 1, double crowns of hybrid inner and outer crowns using the conventional casting method; Group 2, double crowns of conus inner and outer crowns using the conventional casting method. Tensile strengths of double crowns when the inner and outer crowns were separated on a universal testing machine were measured. These values of retentive force were then statistically analyzed using the Kruskal-Wallis test. Results. Retentive force in group 2 was significantly higher than that in group 1(p<.05). Conclusion. The initial retentive forces of double crowns were affected by the types of the double crown system.

A STUDY ON THE RETENTIVE FORCE OF CIRCUMFERENTIAL CLASP (환상형 클래스프의 유지력에 관한 연구)

  • Lee, Jae-Sun;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.669-682
    • /
    • 1998
  • The purpose of this study was to compare the retentive force of cast half round circumferential clasps, cast round circumferential clasps and wrought wire clasps on three different depths of undercut(10G,20G.30G), and to determine the proper amount of undercut for cast round circumferential clasp. Three different lower second premolar crowns were cast and each of clasp was made. Each of clasp affixed to the different types of clasp. Their retentive forces were measured with universal testing machine. The results were as follows : 1. When the depth of undercut was same, the greatest retentive force was exerted by cast half round circumferential clasp, followed by cast round - 33 - circumferential clasp and wrought wire clasp. 2. The degree of variation amount of retentive force according to depth of undercut was greatest for cast round circumferential clasp. 3. Not only elastic deformation but also permanent deformation of the retentive arm was observed after insertion and removal of the clasp. The results of this study show that the retentive force of cast round circumferential clasp falls between those of cast half round circumferential clasp and wrought wire clasp, and suggest that a 20G undercut is suitable for ensuring an appropriate degree of the retentive force.

  • PDF

The effect of resin cements and primer on retentive force of zirconia copings bonded to zirconia abutments with insufficient retention

  • Kim, Seung-Mi;Yoon, Ji-Young;Lee, Myung-Hyun;Oh, Nam-Sik
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.198-203
    • /
    • 2013
  • PURPOSE. The purpose of this study was to investigate the effect of resin cements and primer on the retentive force of zirconia copings bonded to zirconia abutments with insufficient retention. MATERIALS AND METHODS. Zirconia blocks (Lava, 3M ESPE, St. Paul, MN, USA) were obtained and forty sets of zirconia abutments and copings were fabricated using CAD/CAM technology. They were grouped into 4 categories as follows, depending on the types of resin cements used, and whether the primer is applied or not:Panavia F2.0 (P), Panavia F2.0 using Primer (PRIME Plus, Bisco Inc, Schaumburg, IL, USA) (PZ), Superbond C&B (S), and Superbond C&B using Primer (SZ). For each of the groups, the cementation was conducted. The specimens were kept in sterilized water ($37^{\circ}C$) for 24 hours. Retentive forces were tested and measured, and a statistical analysis was carried out. The nature of failure was recorded. RESULTS. The means and standard deviations of retentive force in Newton for each group were $265.15{\pm}35.04$ N (P), $318.21{\pm}22.24$ N (PZ), $445.13{\pm}78.54$ N (S) and $508.21{\pm}79.48$ N (SZ). Superbond C&B groups (S & SZ) showed significantly higher retentive force than Panavia F2.0 groups (P & PZ). In Panavia F2.0 groups, the use of primer was found to contribute to the increase of retentive force. On the other hand, in Superbond C&B groups, the use of primer did not influence the retention forces. Adhesive failure was observed in all groups. CONCLUSION. This study suggests that cementation of the zirconia abutments and zirconia copings with Superbond C&B have a higher retentive force than Panavia F2.0. When using Panavia F2.0, the use of primer increases the retentive force.

A COMPARATIVE OF RETENTIVE FORCE OF VARIOUS OVERDENTURES USING SEVERAL MAGNETS (수종의 Magnet를 이용한 Overdenture의 유지력에 관한 비교연구)

  • Hur, Kyoung-Sook;Hur, Song-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.49-57
    • /
    • 1991
  • The magnets were widely used to increase the retention of overdentures. The purpose of this study was to compare the break load between overdentures and edentulous models. For this study, Model former(U-402) was used for model fabrication and four different magnets were used for evaluation of break load. The artificial saliva was used between overdenture and model. Breakaway loads were tested with an Instron 1122 at a speed of 2mm/min. The results were as follows. 1. The retentivee forces complete dentures with artificial saliva were than the retentive forces of complete detures without artificial saliva. 2. Magnetic overdenture with artificial saliva showed best retentive force, magnetic overdenture without artificial saliva showed the next retentive force, and the complete denture without artificial saliva showed the worst retention. 3. As the magnetic sizes increased, the retentive forces of magnetics were increased. 4. The retentive force of nipple shape magnet is greater than the retentive force of flate shape magnet in the same size.

  • PDF

INFLUENCE OF THE CLASP ARM LENGTH ON THE CHANGE OF RETENTIVE FORCE WITH REPEATED PLACEMENT AND REMOVAL (반복 장착 철거시 CLASP ARM의 길이가 유지력의 변화에 미치는 영향)

  • Ahn, Kwang-Ho;Dong, Jin-Keun;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.281-287
    • /
    • 1991
  • This study was designed to investigate the influence of the clasp arm length on the change of retentive force with repeated placement or removal. The author measured the retentive force of Akers clasp and I-bar clasp in the depth of undercut 0.5mm, 0.25mm, respectively, varying the length of clasp arm, that is, 10mm, 14mm, 17mm in Akers clasp and 16mm, 18mm, 20mm in I-bar clasp. The retentive force was measured just before the placement of removal, after 100 times repeated placement or removal, after 300 times repeated placement or removal. The obtained results were as follows : 1. The shorter the clasp arm, the greater retention in Akers clasp and I-bar clasp(p<0.05). 2. There was decreased retentive force of Akers clasp and I-bar clasp after 300 times repeated placement or removal(p.<0.005). 3. The decreasing rate of retentive force in Akers clasp with 10mm was higher than that with 17mm, after 300 times repeated placement or removal, but there was no statistica difference(p>0.05).

  • PDF

RETENTIVE FORCES OF CLASPS OF REMOVABLE ORTHODONTIC APPLIANCES FOR CHILDREN (어린이에게 사용되는 가철식 교정장치용 clasp의 유지력비교)

  • Han, Jeong-Jae;Lee, Kwang-Hee;Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.207-217
    • /
    • 1999
  • The purpose of this study was to compare the retentive forces of various types of clasps for removable orthodontic appliances for primary and mixed dentition. Seven metal models of a single tooth and two teeth were made, including maxillary left primary canine, first primary molar, second primary molar and first molar. Retentive forces of Adams clasp, circumferential clasp(C clasp), Jackson clasp, Duyzing clasp, arrowhead clasp, ball clasp, eyelet clasp, and triangular clasp were measured by Universal Testing Machine(Zwick Z020, Germany). The obtained results were as follows. 1. Jackson clasp and Adams clasp showed the highest retentive force among single tooth clasps. 2. C clasp showed the lowest retentive force, and there was no statistically significant difference in retentive force between mesial end C clasp and distal end C clasp. 3. Eyelet clasp showed the highest, and ball clasp showed the lowest retentive farce among clasps for interdental undercut. 4. Triangular clasp showed higher retentive force than ball clasp.

  • PDF

THE EXPERIMENTAL STUDY ON THE EFFECT OF THE INSERTION-WITHDRAWAL COUNT TO THE RETENTIVE CAPACITIES OF SEVERAL Cr-Co ALLOY CLASPS (삽입철거 회수가 수종의 Cr-Co 합금 Clasp 유지력에 미치는 영향에 관한 실험적 연구)

  • Bae Jung-Soo;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.4
    • /
    • pp.498-507
    • /
    • 1992
  • This study was to investigate the retentive force changes according to repeated insertion and withdrawal of Cr-Co alloy clasps, commonly used in this country, and the differences in retentive capacities between Aker's clasp and I-bar clasp. The author selected 4 kinds of Cr-Co alloys and Type IV gold alloy, and measured the retentive force changes of each clasp type in undercut depth of 0.25mm and analyzed statistically. The following results were obtained. 1. In both Aker's and I-bar clasps, there were no statistically significant differencies in retentive forces among 4 Cr-Co alloys. 2. Cr-Co alloys exerted greater retentive forces than those of gold alloy, 2 times greater in Aker's clasps and 2.5 times in I-bar clasps. 3. In all test specimens, I-bar clasps exerted greater retentive forces than Aker's clasps. 4. In all test specimens, there were trends of second order relationships in retentive force changes.

  • PDF

Retentive Force of Dental Impression Tray According to Retention form (유지형태에 따른 치과 인상용 트레이의 유지력에 관한 연구)

  • Choi, Min-Ho;Shin, Dong-Kuk;Kim, Min-Jeong;Oh, Sang-Chun;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2004
  • This study was performed to measure the retentive force of dental impression tray according to retention form. The 9 resin beams($30{\times}60{\times}2.5mm$) were made of visible light-curing tray resin according to the surface texture, the size of hole and the number of rim. The resin block was fabricated in width 50mm, length 30mm, heght 40mm to maintain an even hydrocolloid impression material. The retentive force between the resin beam and hydrocolloid impression material was measured by Universal Testing Machine(Zwick Z020, Zwick Co., Germany). The results obtained in this study were as follows : 1. The retentive force of the resin beam with bilateral 4 rims, 2mm holes(9group) was highest(9.18kg), and the polishing resin beam(2group) was worst(4.85kg). 2. There was no significant difference between the polished the resin beam(2group) and the contrast resin beam(1group). 3. The retentive force of the rimmed resin beam was higher than the perforated resin beam. 4. The retentive force of the 2mm perforated resin beam(4group) was higher than the 3mm perforated resin beam(3group). 5. As increasing the number of rim increased the retentive force.

RETENTIVE FORCE OF ADJUSTABLE DENTAL IMPRESSION TRAYS WITH DIFFERENT RETENTION FORMS (유지형태에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구)

  • Song Kie-Bum;Kim Sung-Rok;Park Kwang-Soo;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.15-29
    • /
    • 2005
  • Statement of problem. The adjustable dental impression trays were made for being adjusted their width automatically along the width of dental arch. Purpose. The purpose of this study was to investigate the best retentive form of adjustable dental impression tray, and so to make it a more satisfactory product. Material and methods. The eight pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) with different distribution of holes and with or without the rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray, and the tray jig which was made for holding the tray on a lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum retentive force by use of a UTM at a constant strain rate of 100mm per minute. A 2-factor analysis of variance (p<.05) was used to determine whether differences existed among distribution of retentive holes and between rim existing and not. Results. 1 The retentive force of the upper and lower resin tray with 2mm holes on the tray border was highest(25.83/24.98kg). (p<.05) 2. As the tray had more retentive holes, it was less retentive. 3. There was no significant difference in the retentive force of the varied hole intervals in the case of distributing all the area. (p>.05) 4. The rimless trays were more retentive generally, than the rimmed trays except 2 case: upper tray group-all area / 2 mm, intervals and lower tray group-margin only / 2 mm, intervals.(p<.05) 5. Most of the adjustable trays were showed higher retentive force than perforated metal tray except the lower group that perforated on the all area at intervals of 2 mm.