• Title/Summary/Keyword: retention time

Search Result 1,731, Processing Time 0.029 seconds

Nutrient Removal Using Fermented Organic Acids Derived from the Primary Sludge in the Intermittent Aeration Activated Sludge Process

  • Weon, Seung-Yeon;Lee, Sang-Il;Lee, Chan-Won
    • Environmental Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.213-218
    • /
    • 2011
  • The two-stage intermittent aeration activated sludge process (IAP) and dynamic-flow intermittent aeration activated sludge process (DFP) were investigated for the nutrient removal of domestic wastewater. Three sets of IAP and one set of DFP were operated. The fermented settled sludge taken from the primary settling tank was added to two IAP and one DFP as an external electron donor, with one IAP, in which an external carbon source was not added, as a control. All the systems were operated at a sludge retention time of 20 days and a hydraulic retention time of 12 hr. A Higher denitrification rate was observed with the fermented settled sludge for the denitrification compared to the process without the addition of the organic source. The result indicates that the fermented acid from the primary domestic sludge has been proved to be an excellent electron donor for denitrification and biological phosphorus removal with IAP and DFP in treating relatively low C/N ratio(Carbon / Nitrogen ratio) wastewater. Phosphate accumulating organisms have a capability of competing with denitrifiers in the presence of volatile organic acids under anoxic conditions.

Development of Submerged Membrane Bioreactor for Biological Nutrient Removal on Municipal Wastewater and Analyzing the Effect of Chemical Cleaning on Microbial Activity (도시 하수에서의 생물학적 고도처리를 위한 MBR공정 개발 및 화학세정에 의한 미생물 활성도 영향 분석)

  • Park, Jong-Bu;Park, Seung-Kook;Hur, Hyung-Woo;Kang, Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.120-124
    • /
    • 2009
  • This study was performed to investigate the application of submerged membrane bioreactor (MBR) system for biological nutrient removal of municipal wastewater. MBR bioreactor consists of four reactors such as anaerobic, stabilization, anoxic and submerged membrane aerobic reactors with two internal recycles. The hydraulic retention time (HRT), sludge retention time (SRT) and flux were 6.2 hr, 34.1 days and $19.6L/m^2/hr$ (LMH), respectively. As a result of operation, the removal efficiency of $COD_{Cr}$, SS, TN and TP were 94.3%, 99.9%, 69.4%, and 74.6%, respectively. There was no significant effect of microbial activity after the maintenance cleaning using 200 mg/L of NaOCl. Membrane filtration for the treatment of municipal wastewater was performed for longer than 9 months without chemical recovery cleaning.

Improvement of Drainage at Wet Pulp Mold Process (습식 펄프몰드 생산공정의 탈수성 향상을 위한 연구)

  • Sung Yong Joo;Ryu Jeong-Yong;Kim Hyung Jin;Kim Tae Keun;Song Bong-Keun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.3
    • /
    • pp.52-59
    • /
    • 2004
  • The greater Increase of the demand for environmental friendly materials especially for packaging industry leads to the larger interest in the reusable and recycable materials such as pulp mold. Although the pulp mold has great characteristics for packaging, some deficiency compared with other packaging material like EPS(Expandable Polystyrene) need to be overcome, for example, the relative higher cost. In this report, since the water drainage rate at the forming zone of a wet pulp mold process could have a great influence on the economical efficiency not only by increasing machine speed but also reducing the drying energy, the optimum ways for increasing drainage were investigated The mechanism of vacuum drainage In pulp mold forming was successfully evaluated by using RDA(Retention and Darinage Analyzer). Since the conditions of stock were greatly affected by the pulping time of low consistency pulper, the optimum pupling time was investigated with considerations of all stock preparation processes. The change of stock temperature and the addition of polyelectrolyte could improve the vacuum drainage rate. It was founded that the wire mesh types of mold former had a little influence on the retention because of the relatively mild vacuum drainage. However, the bigger size of dewatering hole showed better drainage rate and could reduce the plugging and con lamination of mold.

Multi-analysis of the Organochlorine Pesticides in Ginseng at Gyeongbuk, Korea (경북지역 인삼 중 유기염소계 농약의 다성분 분석)

  • Park Moon-Ki;Kim Jung-Ho
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.193-199
    • /
    • 2005
  • To obtain the residual organochlorine pesticides in the ginseng, the methods of multi-analysis for BHC's isomer, DDT's isomer and other organochlorine pesticides by GC-ECD are surveyed. The relative retention time for $\alpha-BHC,\;\beta-BHC,\;\delta-BHC\;and\;\gamma-BHC$ is 1.000, 1.025, 1.034 and 1.056, respectively. The relative retention time for o,p-DDE, p,p-DDE, o,o-DDD, o,p-DDT, o,p-DDD, and p,p-DDT is 1.199, 1.230, 1.242, 1.286, 1.329 and 1.333, respectively. The BHC isomers, DDT's isomer and other organochlorine pesticides are separated with multianalysis condition. The qualified defection concentration for $\alpha-BHC$, Quintozene, Aldrin, Captan, $\alpha-Endosulfan$, and Dieldrin is 0.95ng/g, 0.27ng/g, 1.04ng/g, 0.63ng/g, 0.55ng/g and 0.62ng/g, respectively. The qualified defection concentration for Fenhexamid, Endrin, $\beta-Endosulfan$, o,p-DDT, Endosulfan-sulfate is 5.71ng/g, 0.61ng/g, 0.48ng/g, 0.44ng/g and 0.51ng/g, respectively. BHC, Aldrin, Dieldrin, Endrin and DDT, which were Korea Food & Drug Administration advisory pesticides, are not detected in soil environment. Also it's residual organochlorine pesticides are not polluted in the ginseng on Sangju Korea.

Bacterial Die-Off in Continuous River Water Flow System

  • Kong, Surk-Key;Toshiuki Nakajima
    • Journal of Environmental Science International
    • /
    • v.12 no.8
    • /
    • pp.847-852
    • /
    • 2003
  • It was examined carefully that the bacterial die-off between Chlorella vulgaris and E. coli. W3110 was tested through adding TOC (total organic carbon) with the lab-scaled continuous river water flow system (CRWFS). Artificial synthetic wastewater was applied at two levels of organic carbon concentration; 1,335 mg/l in treatment type 1 and 267 mg/l in type 2. In both types, the population densities of Chlorella vulgaris were similar in a maximum 8.25 ${\times}$ 10$\^$6/ cells/ml (type 1) and 6.925 ${\times}$ 10$\^$6/ cells/ml (type 2). The maximum densities of E. coli. W3110 were 2.0 ${\times}$ 10$\^$8/ colony forming unit (CFU)/ml in type 1 and 3.9 ${\times}$ 10$\^$8/ CFU/ml in type 2. The densities increased for 11 days in type 1 and 4 days in type 2, then decreased rapidly till the 35th day, then slightly increased again. This trend was prominent in type 2. It implied that a wider range of nutrients was required in the growth of heterotrophic bacteria in type 2 than in type 1. We could not expect successful bacterial die-off if the wastewater retention time was not furnished sufficiently.

A study on the Remote Control System for Measuring Gradient of temporary earth retaining structure (흙막이 가시설 구조물의 무선원격계측관리시스템에 관한 연구)

  • Woo, Jong-Yeol;Hong, Seong-Wook;Kim, Sang-Won;Seo, Yong-Chil;Shin, Chan-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.49-52
    • /
    • 2011
  • This study concerned with the retention structures or inverted temporary building for displacement measurement in the underground soil after drilling a vertical tilt sensor attached to the vertical distance required to maintain a real-time measurement and management in order to install the wireless measuring devices installed in the field through remote control and management program for the safety of retaining structures temporary building be found on the internet in real time temporary building the retention is to develop a safety management system. And based on this technology to monitor the future status of the various structures possible to add a variety of sensors and Life Cycle Prediction of the structure and needs to evolve into intelligent systems and wireless networks using wireless communications infrastructure systems based on expanding domestic market penetration by developing instrumentation pioneer in overseas markets as well as the activation can also be judged.

  • PDF

A Study on the Water Quality Purification Effect of Aquatic Plants in field work (현장실험을 통한 수생식물의 수질정화 효과에 관한 연구)

  • Lee Jong-Sung;Kim Ki-Nam
    • Journal of Environmental Science International
    • /
    • v.14 no.10
    • /
    • pp.937-944
    • /
    • 2005
  • Presently, aquatic plants are used for the water purification in inland water. This study was carried out to investigate the water purification effect of aquatic plants, Oenanthe javanica and Typha angustata, The experiment was conducted in outdoor flowing water was conducted for ten days, Water quality was measured in terms of water temperature, COD(chemical oxygen demand), SS(suspended solids), Total N, Total P. The results of field experimentation showed that hydraulic retention time was the earliest in July and August 2003, and there were not any particular changes of monthly water temperature in inflow water and outflow water. As we look at the changes taken place in inflow water and outflow water throughout the whole experiment period, the change of water quality in summer was salient, especially SS removal ratio showed distinguished change as $25\%$, when the pebble filter and aquatic were attached to it. The removal rate of COD, total N total P were $14,7\%,\;8\%\;and\;9\%$, respectively. In relating the length of water extension to the change in water quality, the water quality tended to get lower generally in proportion to hydraulic retention time.

Treatability Study on the SepticTAnk Sludges

  • Byung Soo Yang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 1981
  • The characteristics of septic tank sludges were investigated and the kinetic coefficients in the aerobic biodegradation were evaluated from bach treatability tests. Using an unbiased statistical method, the estimated values, k (substrate removal rate coefficient) =0. 0175hr-1 at 17\ulcornerC, K. (Michaelis Menten constant) = 248mg/ e, a (cell yield coefficient)=0.625, and Kd (cell decay coefficient:' =0. 00192hr-1 were obtained based on biodegradable COD(mg/ \ulcorner) and volatile suspended solids(mg/\ulcorner). The relationship between COD and BOD, COD (mg/\ulcorner) =2. 1 BOD(mg/\ulcorner) +250, also was established for the septic tank sludges. Dilution was inevitable for the grit removal because of the high viscosity of the sludges. An aerobic activated sludge process rather than anaerobic processes was recommended for the removal of soluble organics after the removal of grit and suspended solids. A multi-stage activated sludge process was adapted for this highly concentrated and not easily-degradable waste. It was estimated that a four-stage activated sludge process would require 40 hours retention time compared to 92 hours for a single-stage process, 52 hours for a double-stage process, and 46 hours for a three stage process in order to achieve an effluent quality of 84mg/ e COD( 40mg/ e BOD) with about 4, OOOmg/ \ulcorner MLSS from an influent quality of I, 500mg/ t COD(714mg/.e BOD), while multi-stages beyond four stage would not save the required retention time significantly.

  • PDF

Performance evaluation of membrane bioreactor (MBR) coupled with activated carbon on tannery wastewater treatment

  • Alighardashi, Abolghasem;Pakan, Mahyar;Jamshidi, Shervin;Shariati, Farshid Pajoum
    • Membrane and Water Treatment
    • /
    • v.8 no.6
    • /
    • pp.517-528
    • /
    • 2017
  • This study evaluates the performance of membrane bioreactor (MBR) coupled with a modified walnut shell granular activated carbon (WSGAC) for tannery wastewater treatment. For this purpose, a pilot with overall volume of 80L and 12 hours hydraulic retention time (HRT) is operated in three scenarios. Here, the chemical oxidation demand (COD) of wastewater is reduced more than 98% in both C:N ratios of 13 (S1) and 6.5 (S2). This performance also remains intact when alkalinity depletes and pH reduces below 6 (S3). The ammonium removal ranges between 99% (S2) and 70% (S3). The reliability of system in different operating conditions is due to high solids retention time and larger flocs formation in MBR. The average breakthrough periods of WSGAC are determined between 15 minutes (S2) and 25 minutes (S1). In this period, the overall nitrate removal of MBR-WSGAC exceeds 95%. It is also realized that adding no chemicals for alkalinity stabilization and consequently pH reduction of MBR effluent (S3) can slightly lengthen the breakthrough from 15 to 20 minutes. Consequently, MBR can successfully remove the organic content of tannery wastewater even in adverse operational conditions and provide proper influent for WSGAC.

Optimum Conditions for Denitrification and Fish Growth in a Seawater Recirculating System (해수 탈질시스템에서 적정 탈질조건과 어류의 사육효과)

  • SON Maeng Hyun;JEON Im Gi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.458-462
    • /
    • 2003
  • This study was to survey proper condition of nitrate removal by hydraulic retention time (HRT) and measured growth of black rockfish (Sebastes schlegeli) and giant croaker (Nibea japonica) in the seawater recirculating culture system designed for nitrate removal. Nitrate conversion to nitrogen at 8 hr-HRT was higher than 16 hr-HRT, amounting to $32.2\;g/m^3/day$ in the seawater recirculating culture system. The removal efficiency of nitrate improved when dissolved oxygen was situated less than 0.5 mg/L. Daily growth rate (DGR) and feed efficiency (FE) of S. schlegeli with mean body weight of 108 g in 8 hr-HRT were significantly higher values than those in 4 hr-HRT (P<0.05). The DGR and FE of N. japonica with mean body weight of 12 g in added carbon system showed not differing in the values from N. japonica in control system (P>0.05).