• Title/Summary/Keyword: retention level

Search Result 645, Processing Time 0.021 seconds

A Study on Location Selection for Rainwater Circulation System Elements at a City Level - Focusing on the Application of the Environmental and Ecological Plan of a Development - (도시차원의 빗물순환체계 요소별 입지선정에 관한 연구 - 개발예정지역의 환경생태계획 적용방안을 중심으로 -)

  • Kim, Hyo-Min;Kim, Kwi-Gon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.3
    • /
    • pp.1-11
    • /
    • 2012
  • This study focused on establishing a natural rainwater circulation system using rainwater meant for relatively large urban development projects such as a new town development. In particular, when the location selection techniques for individual elements of a natural rainwater circulation system are developed for the integrated rainwater management, changes in hydrological environment will be minimized and the natural water circulation would be restored to realize the low impact development (LID). In that case, not only the excess will be reduced but water space and green areas in a city would also increase to improve the urban sustainability. First of all, there were five elements selected for the location selection of a rainwater circulation system intended for the integrated rainwater management: rainwater collection, infiltration, filtration, retention and movement spaces. After generating these items, the location selection items and criteria were defined for each of the five elements. For a technique to apply the generated evaluation items and criteria, a grid cell analysis was conducted based m the suitability index theory, and thematic maps were overlapped through suitability assessment of each element and graded based on the suitability index. The priority areas were identified for each element. The developed technique was applied to a site where Gim-cheon Innovation City development is planned to review its feasibility and limitations. The combined score of the overlapped map for each element was separated into five levels: very low, low, moderate, high and very high. Finally, it was concluded that creating a rainwater circulation system conceptual map m the current land use plan based on the outcome of the application would be useful in building a water circulation system at the de1ailed space planning stage after environmental and ecological planning. Furthermore, we use the results of this study as a means for environment-friendly urban planning for sustainable urban development.

Effect of Types of Egg Shell Calcium Salts and Egg Shell Membrane on Calcium Metabolism in Rats (난각 칼슘염의 종류와 난막의 존재유무가 흰쥐의 칼슘대사에 미치는 영향)

  • Noh, Kyung-Hee;Lee, Sang-Hyun;Ma, Jie;Zhou, Yusi;Kim, Jae-Cherl;Kim, Myo-Jeong;Song, Young-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.7
    • /
    • pp.853-859
    • /
    • 2006
  • This study was carried out to investigate the effect of egg shell calcium salt types and egg shell membrane on calcium metabolism in rats. Sprague-Dawley male rats, 4 weeks of age, were fed on free-calcium diets for 2 weeks after adjustment period. Rats weighing approximately $247{\pm}2.3g$ were divided into 6 groups and were fed on the experimental diets containing 0.2% calcium for 4 weeks. Experimental groups were as follows; {ES(M+)} (egg shell powder diet with egg shell membrane), {ES(M-)} (egg shell powder diet without egg shell membrane), {AC(M+)} (egg shell calcium acetate diet with egg shell membrance), {AC(M-)} (egg shell calcium acetate diet without eg shell membrane), {GC(M+)} (egg shell calcium glucuronate diet with egg shell membrane) and {GC(M-)} (egg shell calcium glucuronate diet without egg shell membrane). Bone length of femur was significantly different by the types (p<0.05) of egg shell calcium salts. Bone mineral density of femur showed the highest level in AC(M-) group. Calcium content of femur and calcium absorption rate were higher in egg shell calcium salt groups than in eg shell powder groups. Calcium absorption rate and retention were significantly different (p<0.05) among the types of eg shell calcium salts and were higher in the AC(M-) group than in the other groups. Alkaline phosphatase activity, parathyroid hormone and osteocalcin levels of serum showed no significant difference among the experimental groups. From the above results, it is concluded that bioavailability of calcium is higher in groups of egg shell calcium salts compared to those in egg shell powder, even though egg shell membrane has no effect on calcium metabolism. Thus, these findings suggest the possibility of using egg shell calcium salts as a functional food material related to calcium metabolism.

A Composition and Role of Urban Water System in Connection with Historic City Structure - Focusing on Gyeongju, Gaegyeong, Hanyang, and Suwon Hwaseong - (역사도시구조와 연계한 도시수체계의 구성형태와 역할에 관한 연구 - 경주, 개경, 한양, 수원화성을 중심으로 -)

  • Kang, In-Ae;Lee, Kyung-Chan
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.39 no.4
    • /
    • pp.99-110
    • /
    • 2021
  • This study intends to examine the characteristics of the construction method of the urban water system in the historical cities of Korea, focusing on Gyeongju, Gyeongju, Goryeo, Hanyang, and Suwon Hwaseong, which were created as new towns in the late Joseon Dynasty. It examines the meaning of waterways in connection with the urban skeletal structure, focusing on the location of cities, roads, and arrangement of urban facilities, and analyzes the compositional form of the water system. We tried to derive the relationship with the structure. In particular, it can be seen that water and natural water systems act as key factors in determining the location of a city, and have a close relationship with the urban structure, urban development process, and urban structure. In addition to the symbolic meaning of water in harmony with the geographical concept, realistic demands in terms of water level and water retention are an important background. In order to respond to various demands related to water space, various planning and technical elements for managing water space were introduced in the process of city formation and development. The planning elements of the urban water system in the process of urban formation and development are summarized as follows through the analysis of the research site. First, in the process of building the urban water system in Gyeongju, Goryeo, Goryeo, Hanyang, and Hwaseong, Suwon, which were selected as the research destinations, the water system in consideration of drainage and disaster is common, but the water system construction method and usability are common. shows the difference. Second, water and natural water systems act as symbolic elements to secure the legitimacy of the city location, and as a key factor in determining the location of the city in harmony with the geographical concept and determining the left direction of the city. Third, the natural water system prior to the formation of a city works as a basis for determining the compositional form of the urban water system constructed in the process of urban formation and development in harmony with the topographical conditions. Fourth, the urban water system built on the basis of natural water systems is constructed by linking natural waterways and planned artificial waterways. Fifth, the urban water system is being built in a planned manner in consideration of the utility in connection with the urban structure, such as securing of urban land, arrangement of urban facilities and areas, composition of functional areas, and land division, in addition to the perspective of drainage system and flood control in consideration of disasters.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.