• Title/Summary/Keyword: result failure

Search Result 3,277, Processing Time 0.038 seconds

An Empirical Study on the Influencing Factors for Big Data Intented Adoption: Focusing on the Strategic Value Recognition and TOE Framework (빅데이터 도입의도에 미치는 영향요인에 관한 연구: 전략적 가치인식과 TOE(Technology Organizational Environment) Framework을 중심으로)

  • Ka, Hoi-Kwang;Kim, Jin-soo
    • Asia pacific journal of information systems
    • /
    • v.24 no.4
    • /
    • pp.443-472
    • /
    • 2014
  • To survive in the global competitive environment, enterprise should be able to solve various problems and find the optimal solution effectively. The big-data is being perceived as a tool for solving enterprise problems effectively and improve competitiveness with its' various problem solving and advanced predictive capabilities. Due to its remarkable performance, the implementation of big data systems has been increased through many enterprises around the world. Currently the big-data is called the 'crude oil' of the 21st century and is expected to provide competitive superiority. The reason why the big data is in the limelight is because while the conventional IT technology has been falling behind much in its possibility level, the big data has gone beyond the technological possibility and has the advantage of being utilized to create new values such as business optimization and new business creation through analysis of big data. Since the big data has been introduced too hastily without considering the strategic value deduction and achievement obtained through the big data, however, there are difficulties in the strategic value deduction and data utilization that can be gained through big data. According to the survey result of 1,800 IT professionals from 18 countries world wide, the percentage of the corporation where the big data is being utilized well was only 28%, and many of them responded that they are having difficulties in strategic value deduction and operation through big data. The strategic value should be deducted and environment phases like corporate internal and external related regulations and systems should be considered in order to introduce big data, but these factors were not well being reflected. The cause of the failure turned out to be that the big data was introduced by way of the IT trend and surrounding environment, but it was introduced hastily in the situation where the introduction condition was not well arranged. The strategic value which can be obtained through big data should be clearly comprehended and systematic environment analysis is very important about applicability in order to introduce successful big data, but since the corporations are considering only partial achievements and technological phases that can be obtained through big data, the successful introduction is not being made. Previous study shows that most of big data researches are focused on big data concept, cases, and practical suggestions without empirical study. The purpose of this study is provide the theoretically and practically useful implementation framework and strategies of big data systems with conducting comprehensive literature review, finding influencing factors for successful big data systems implementation, and analysing empirical models. To do this, the elements which can affect the introduction intention of big data were deducted by reviewing the information system's successful factors, strategic value perception factors, considering factors for the information system introduction environment and big data related literature in order to comprehend the effect factors when the corporations introduce big data and structured questionnaire was developed. After that, the questionnaire and the statistical analysis were performed with the people in charge of the big data inside the corporations as objects. According to the statistical analysis, it was shown that the strategic value perception factor and the inside-industry environmental factors affected positively the introduction intention of big data. The theoretical, practical and political implications deducted from the study result is as follows. The frist theoretical implication is that this study has proposed theoretically effect factors which affect the introduction intention of big data by reviewing the strategic value perception and environmental factors and big data related precedent studies and proposed the variables and measurement items which were analyzed empirically and verified. This study has meaning in that it has measured the influence of each variable on the introduction intention by verifying the relationship between the independent variables and the dependent variables through structural equation model. Second, this study has defined the independent variable(strategic value perception, environment), dependent variable(introduction intention) and regulatory variable(type of business and corporate size) about big data introduction intention and has arranged theoretical base in studying big data related field empirically afterwards by developing measurement items which has obtained credibility and validity. Third, by verifying the strategic value perception factors and the significance about environmental factors proposed in the conventional precedent studies, this study will be able to give aid to the afterwards empirical study about effect factors on big data introduction. The operational implications are as follows. First, this study has arranged the empirical study base about big data field by investigating the cause and effect relationship about the influence of the strategic value perception factor and environmental factor on the introduction intention and proposing the measurement items which has obtained the justice, credibility and validity etc. Second, this study has proposed the study result that the strategic value perception factor affects positively the big data introduction intention and it has meaning in that the importance of the strategic value perception has been presented. Third, the study has proposed that the corporation which introduces big data should consider the big data introduction through precise analysis about industry's internal environment. Fourth, this study has proposed the point that the size and type of business of the corresponding corporation should be considered in introducing the big data by presenting the difference of the effect factors of big data introduction depending on the size and type of business of the corporation. The political implications are as follows. First, variety of utilization of big data is needed. The strategic value that big data has can be accessed in various ways in the product, service field, productivity field, decision making field etc and can be utilized in all the business fields based on that, but the parts that main domestic corporations are considering are limited to some parts of the products and service fields. Accordingly, in introducing big data, reviewing the phase about utilization in detail and design the big data system in a form which can maximize the utilization rate will be necessary. Second, the study is proposing the burden of the cost of the system introduction, difficulty in utilization in the system and lack of credibility in the supply corporations etc in the big data introduction phase by corporations. Since the world IT corporations are predominating the big data market, the big data introduction of domestic corporations can not but to be dependent on the foreign corporations. When considering that fact, that our country does not have global IT corporations even though it is world powerful IT country, the big data can be thought to be the chance to rear world level corporations. Accordingly, the government shall need to rear star corporations through active political support. Third, the corporations' internal and external professional manpower for the big data introduction and operation lacks. Big data is a system where how valuable data can be deducted utilizing data is more important than the system construction itself. For this, talent who are equipped with academic knowledge and experience in various fields like IT, statistics, strategy and management etc and manpower training should be implemented through systematic education for these talents. This study has arranged theoretical base for empirical studies about big data related fields by comprehending the main variables which affect the big data introduction intention and verifying them and is expected to be able to propose useful guidelines for the corporations and policy developers who are considering big data implementationby analyzing empirically that theoretical base.

The Role of Tumor Necrosis Factor-$\alpha$ and Interleukin-$1{\beta}$ as Predictable Markers for Development of Adult Respiratory Distress Syndrome in Septic Syndrome (패혈증 증후군환자에서 성인성 호흡곤란 증후군 발생의 예측 지표서의 혈중 Tumor Necrosis Factor-$\alpha$와 Interleukin-$1{\beta}$에 관한 연구)

  • Koh, Youn-Suck;Jang, Yun-Hae;Kim, Woo-Sung;Lee, Jae-Dam;Oh, Soon-Hwan;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.452-461
    • /
    • 1994
  • Background: Tumor necrosis factor(TNF)-$\alpha$ and Interleukin(lL)-$1{\beta}$ are thought to play a major role in the pathogenesis of the septic syndrome, which is frequently associated with adult respiratory distress syndrome(ARDS). In spite of many reports for the role of TNF-$\alpha$ in the pathogenesis of ARDS, including human studies, it has been reported that TNF-$\alpha$ is not sensitive and specific marker for impending ARDS. But there is a possibility that the results were affected by the diversity of pathogenetic mechanisms leading to the ARDS because of various underlying disorders of the study group in the previous reports. The purpose of the present study was to evaluate the roles of TNF-$\alpha$ and IL-$1{\beta}$ as a predictable marker for development of ARDS in the patients with septic syndrome, in which the pathogenesis is believed to be mainly cytokine-mediated. Methods: Thirty-six patients of the septic syndrome hospitalized in the intensive care units of the Asan Medical Center were studied. Sixteens suffered from ARDS, whereas the remaining 20 were at the risk of developing ARDS(acute hypoxemic respiratory failure, AHRF). In all patients venous blood samples were collected in heparin-coated tubes at the time of enrollment, at 24 and 72 h thereafter. TNF-$\alpha$ and IL-$1{\beta}$ was measured by an enzyme-linked immunosorbent assay (ELISA). All data are expressed as median with interquartile range. Results: 1) Plama TNF-$\alpha$ levels: Plasma TNF-$\beta$ levels were less than 10pg/mL, which is lowest detection value of the kit used in this study within the range of the $mean{\pm}2SD$, in all of the normal controls, 8 of 16 subjects of ARDS and in 8 in 20 subjects of AHRF. Plasma TNF-$\alpha$ levels from patients with ARDS were 10.26pg/mL(median; <10-16.99pg/mL, interquartile range) and not different from those of patients at AHRF(10.82, <10-20.38pg/mL). There was also no significant difference between pre-ARDS(<10, <10-15.32pg/mL) and ARDS(<10, <10-10.22pg/mL). TNF-$\alpha$ levels were significantly greater in the patients with shock than the patients without shock(12.53pg/mL vs. <10pg/mL) (p<0.01). There was no statistical significance between survivors(<10, <10-12.92pg/mL) and nonsurvivors(11.80, <10-20.8pg/mL) (P=0.28) in the plasma TNF-$\alpha$ levels. 2) Plasma IL-$1{\beta}$ levels: Plasma IL-$1{\beta}$ levels were less than 0.3ng/mL, which is the lowest detection value of the kit used in this study, in one of each patients group. There was no significant difference in IL-$1{\beta}$ levels of the ARDS(2.22, 1.37-8.01ng/mL) and of the AHRF(2.13, 0.83-5.29ng/mL). There was also no significant difference between pre-ARDS(2.53, <0.3-8.34ngfmL) and ARDS(5.35, 0.66-11.51ng/mL), and between patients with septic shock and patients without shock (2.51, 1.28-8.34 vs 1.46, 0.15-2.13ng/mL). Plasma IL-$1{\beta}$ levels were significantly different between survivors(1.37, 0.4-2.36ng/mL) and nonsurvivors(2.84, 1.46-8.34ng/mL). Conclusion: Plasma TNF-$\alpha$ and IL-$1{\beta}$ level are not a predictable marker for development of ARDS. But TNF-$\alpha$ is a marker for shock in septic syndrome. These result could not exclude a possibility of pathophysiologic roles of TNF-$\alpha$ and IL-$1{\beta}$ in acute lung injury because these cytokine could be locally produced and exert its effects within the lungs.

  • PDF

A Study on the Stress Distribution of Tooth/Implant Connected with Konus Telescope Denture Using 3-Dimensional Finite Element Method (이중관으로 연결된 자연치와 임플랜트의 악골 내응력분포에 관한 3차원 유한요소분석)

  • Lee, Su-Ok;Choi, Dae-Gyun;Kwon, Kung-Rock;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.381-395
    • /
    • 2008
  • Purpoose: For decades dental implants have been used widely in the field of prosthetic dentistry. However there is confusion when establishing treatment plans in cases where some teeth are remained but an insufficient number of implants can be used due to limited anatomical status and ecomomical problems. Many clinicians have tried to connect natural teeth and implants, and it still has controversy. But, there have been few studies on mechanical analysis of connecting natural teeth and implants with konus telescopic removable partial dentures. The purpose of this study was to analyze the stress distribution of prosthesis, abutment and alveolar bone when teeth and implants were connected with the konus telescopic denture, by means of 3-dimensional finite element analysis. Material and methods: The assumption of this study was that there were 2 mandibular canine (11 mm in length, 4 mm in diameter) and 2 implants(10 mm in length, 4 mm in diameter) which are located in the second premolar region. The mandible, teeth, implants, abutments, and connectors are modeled, and analyzed with the commercial software, ANSYS Version 8.1(Swanson, Inc., USA). The control group used implants instead of natural teeth. 21038 elements, 23544 nodes were used in experimental group and 107595 elements, 21963 nodes were used in control group, Stress distribution was evaluated under 150 N vertical load on 3 experimental conditions - between teeth and implants (Load case 1), posterior to implants (Load case 2), between natural teeth (Load case 3). Results: 1. In all load cases, higher von mises stress value was observed in the experimental group. 2. Maximum von miss stress observed in all load cases and all locations were as follows ; a. 929.44 Mpa in the experimental group, 640.044 Mpa in the control group in outer crown and connector - The experimental group showed 1.45 times high value compared with the control group. b. 145,051 Mpa in the experimental group, 142.338 Mpa in the control group in abutment - The experimental group showed 1.02times high value compared with the control group. c. 32.489 Mpa in the experimental group, 25.765 Mpa in the control group in alveolar bone - The experimental group showed 1.26times higher value compared with the control group. 3. All maximum von mises stress was observed in load case 2, and maxim von mises stress in alveolar bone was 32.489 Mpa at which implant failure cannot occur. 4. If maximum von mises stress is compared between two groups, the value of the experimental group is 1.02 times higher than the control group in abutment, 1.26 times higher than the control group in alveolar bone. Conclusion: If natural teeth and implants are connected with the konus telescopic denture, maximum stress will be similar in abutment, 1.26 times higher in alveolar bone than the control group. With this result, there may be possible to make to avoid konus telescopic dentures where natural teeth and implants exist together.

Initial Experience of the Emergency Bypass System ($EBS^{(R)}$) for the Patients with Cardiogenic Shock due to an Acute Myocardial Infarction (급성 심근경색으로 인한 심인성 쇼크 환자에 대한 경피적 순환 보조장치($EBS^{(R)}$) 적용의 초기경험)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Ryu, Jae-Wook;Kim, Seok-Kon;Kim, Young-Hwa;Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.329-334
    • /
    • 2008
  • Background: Percutaneous cardiopulmonary support. (PCPS) has the potential to rescue patients in cardiogenic shock who might otherwise die. PCPS has been a therapeutic option in a variety of the clinical settings such as for patients with myocardial Infarction, high-risk coronary intervention and postcardiotomy cardiogenic shock, and the PCPS device is easy to install. We report our early experience with PCPS as a life saving procedure in cardiogenic shock patients due to acute myocardial infarction. Material and Method: From January 2005 to December 2006, eight patients in cardiogenic shock with acute myocardial infarction underwent PCPS using the CAPIOX emergency bypass system($EBS^{(R)}$, Terumo, Tokyo, Japan). Uptake cannulae were inserted deep into the femoral vein up to the right atrium and return cannulae were inserted into the femoral artery with Seldinger techniques using 20 and 16-French cannulae, respectively. Simultaneously, autopriming was performed at the $EBS^{(R)}$ circuit. The $EBS^{(R)}$ flow rate was maintained between $2.5{\sim}3.0L/min/m^2$ and anticoagulation was performed using intravenous heparin with an ACT level above 200 seconds. Result: The mean age of patients was $61.1{\pm}14.2$ years (range, 39 to 77 years). Three patients were under control of the $EBS^{(R)}$ before percutaneous coronary intervention (PCI), three patients were under control of the $EBS^{(R)}$ during PCI, one patient was under control of the $EBS^{(R)}$ after PCI, and one patient was under control of the $EBS^{(R)}$ after coronary bypass surgery. The mean support time was $47.5{\pm}27.9$ hours (range, 8 to 76 hours). Five patients (62.5%) could be weaned from the $EBS^{(R)}$ after $53.6{\pm}27.2$ hours. (range, 12 to 68 hours) of support. All of the patients who could successfully be weaned from support were discharged from the hospital. There were three complications: one case of gastrointestinal bleeding and two cases of acute renal failure. Two of the three mortality cases were under cardiac arrest before $EBS^{(R)}$ support, and one patient had an intractable ventricular arrhythmia during the support. All of the discharged patients are still surviving at $16.8{\pm}3.1$ months (range, 12 to 20 months) of follow-up. Conclusion: The use of $EBS^{(R)}$ for cardiogenic shock caused by an acute myocardial infarction could rescue patients who might otherwise have died. Successfully recovered patients after $EBS^{(R)}$ treatment have survived without severe complications. More experience and additional clinical investigations are necessary to elucidate the proper installation timing and management protocol of the $EBS^{(R)}$ in the future.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.

Tetralogy of Fallot Associated with Pulmonary Atresia and Major Aortopulmonary Collateral Arteries -Comparison between the different surgical approaches- (폐동맥폐쇄와 주대동맥폐동맥혈관부행지를 동반한 활로씨사징증 -다양한 외과적 치료접근의 비교-)

  • 이정렬;양지혁;김용진;노준량
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.471-479
    • /
    • 1999
  • Background: Patients with tetralogy of Fallot(TOF), pulmonary atresia(PA) and major aortopulmonary collateral arteries(MAPCAs) have been managed by heterogenous surgical strategies. We have taken 5 different surgical approaches to this lesion. In this study, relative advantages and disadvantages of each strategy were discussed by analyzing our surgical results. Material and Method: Between January 1986 and June 1998, 50 patients aged 1 to 177(39${\pm}$31) months at a various morphologic spectrum of this lesion were treated at our institution. The groups, which were classified according to the initial approaches, consisted of one-stage unifocalization(A-1, n=9), staged unifocalization(A-2, n=11), right ventricle to pulmonary artery connection(RV-PA)(B-1, n=11), one-stage RV-PA plus unifocalization (B-2, n=11), and one-stage definitive repair(C, n=8). Morphologic charateristics, operative mortalities, and probabilities of definitive repair were compared between the groups and the causes of death, complications and the follow-up results were described. Result: Mean ages at the first operation were 57${\pm}$18(A-1), 42${\pm}$48(A-2), 18${\pm}$14(B-1), 52${\pm}$55(B-2), and 32${\pm}$34(C) months (p<0.05). Mean numbers of MAPCAs were least in group C (A-1=4.3${\pm}$1.0, A-2=4.5${\pm}$1.3, B-1=4.1${\pm}$1.9, B-2=4.1${\pm}$1.6, C=3.4${\pm}$1.8 : p<0.05). The ratios of the direct and the indirect MAPCAs in each group were not different between the grousps (A-1=91%/9%, A-2=78%/22%, B-1=80%/20%, B-2=80%/20%, C=81%/19% : p>0.05). Nineteen patients had more than 1 dependent MAPCAs. True pulmonary arteries were not present 13 patients and they were confluent in 29. A total of 101 operations were performed. Operative mortalities of initial procedures were 33%(3/9, A-1), 18%(2/11, A-2), 0%(0/11, B-1), 36%(5/11, B-2) and 13%(1/8, C) (p<0.05). Percentages of the definitive repair among the patients of each group were 22%(2/9, A-1), 18%(2/11, A-2). 45%(5/11, B-1), 27%(4/11, B-2), and 100%(8/8, C)(p<0.05). Hypoxic respiratory and cardiac failure(6), hypoxic encephalopathy(2) and sepsis(4) were the major causes of death. Phrenic nerve palsy occured in 5 patients. Thirty-one patients among the survivals have been followed up for a mean duration of 74${\pm}$42(3-145) months. One and five year actuarial survival rates were 73% and 73 %. Conclusion: In conclusion, Right ventricle to pulmonary artery connection used in patients with TOF/PA/MAPCA as an inital procedure appeared to be highly successful in enhancing the chance of satisfactory definitive repair without the significant surgical risks. One-stage total repair at an ealier age group could be performed safely with the resonable outcomes. Unifocalization approach, whether it was performed in a single stage or in the multiple stages, resulted in the high operative mortality and the lowest chance of definitive repair, however more tailored selection of the patients and the long follow-up is mandatory to prove the usefulness of this approach.

  • PDF

Prognosis Factors of Tricuspid Regurgitation after the Operation for Left-sided Valvular Heart Disease (좌심실 판막질환 수술 후 동반된 삼첨판패쇄부전증의 경과에 영향을 미치는 요인)

  • Jin, Ung;Kim, Hwan-Wook;Lee, Jong-Ho;Kweon, Jong-Bum;Jo, Min-Seop;Yoon, Jeong-Seob;Moon, Seok-Whan;Sim, Sung-Bo;Park, Kuhn;Kim, Chi-Kyung;Cho, Keon-Hyun;Wang, Young-Pil;Lee, Sun-He;Kwack, Moon-Sub
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.150-156
    • /
    • 2003
  • Tricuspid regurgitation has been considered as a secondary lesion when it is combined with left valvular heart diseases. However, there have been some reports which show that tricuspid regurgitation keeps going and results in congestive heart failure even after a successful operation for left valvular heart disease. So far, there are no definite operation indications and predictive factors for the tricuspid re-gurgitation which is resulted from the left sided valvular heart disease. We designed this study to evaluate the effects of pulmonary artery pressure and left ventricular ejection fraction on the prognosis of tricuspid regurgitation, and to make an operation indication for the patients with secondary tricuspid regurgitation. Material and Method: We reviewed the medical records of patients who underwent surgery for the left sided valvular heart disease with tricuspid regurgitation and were followed for more than 1 year with echocardiograms. There was a total of 114 cases. We compared the grades of tricuspid regurgitations and pulmonary artery pressures and left ventricular ejection fractions on the basis of echocardiograms which were checked preoperatively and on the last follow up. Result: There were 43 cases of tricuspid an-nuloplasty. In these patients, the grades of tricuspid regurgitations were improved in 42 cases (97.7%). But in 71 cases without annuloplasty, 29 cases (41%) were improved, 32 cases (45%) had no change, and 29 cases (14%) were aggravated. This finding shows significant differences in the prognoses of tricuspid regur-gitations between the two groups (p<0.05). There was no difference in pulmonary artery pressures and ejection fractions between the patients who showed progression of tricuspid regurgitations and those who didn't (p > 0.05). The improvements of tricuspid regurgitations are not statistically related to the changes of pulmonary artery pressures or left ventricular ejection fractions. Conclusion: This study shows that it is impossible to predict the prognoses of tricuspid regurgitations with preoperative pulmonary artery pressures or left ventricular ejection fractions. Also, the excellent results of tricuspid annuloplasty is proven in controlling the secondary tricuspid regurgitations. Therefore, when tricuspid regurgitation is detected preoperatively, the procedures to correct the tricuspid regurgitation at the time of the operation for the left-sided valvular heart disease must be considered positively, regardless of the grades of tricuspid regurgitations, to prevent sig-nificant tricuspid regurgitation that may develop later.

Analysis of Childhood Rapidly Progressive Glomerulonephritis (소아 급속 진행성 사구체신염의 임상적 고찰)

  • Uhm Ji Hyun;Kim Mi Jin;Lee Young-Mock;Kim Ji Hong;Lee Jae Seung;Kim Pyung-Kil;Hong Soon Won;Jeung Hyeun Joo
    • Childhood Kidney Diseases
    • /
    • v.5 no.2
    • /
    • pp.78-86
    • /
    • 2001
  • Purpose: Rapidly progressive glomerulonephritis (RPGN) is characterized by the rapid increase in serum creatitnin and crescents formation involving more than $50\%$ of glomeruli. 10 patients who had been treated for RPGN were studied retrospectively for thier underlying diseases and clinical features Method: Cilinical review was performed on 10 children who were diagnosed with RPGN by clinical features and renal biopsy and followed up at department of pediatrics during tile last 10 years, from May 1990 to May 2000. Result: There were 6 males and 4 females between the ages of 2.1 and 14.3 years (mean $10.9{\pm}3.8$). 3 had Henoch-$Sch{\ddot{o}}nlein$ purpura nephritis; 2, idiopathic rapidly progressive glomerulonephritis; 2, lupus nephritis; 1, hemolytic uremic syndrome; 1, membranous glomerulonephritis and 1, microscopic polyangiitis. The most common chief complaints were gross hematuria and oliguria. Initial clinical features included proteinuria, edema, hypertension, nausea and arthralgia. Mean serum BUN was $74.2{\pm}39.1\;mg/dL$ mean serum creatinin, $3.2{\pm}1.8\;mg/dL$ and mean creatinin clearance, $26.5{\pm}13.2\;mL/min/1.73m^2$. Antineutrophil cytoplasmic antibody was positive only in microscopic polyangiitis. ANA and Anti-DNA antibody were positive in two lupus nephritis patients. Serum complements were decreased in 4 patients. All patients except Hemolytic uremic syndrome received steroid pulse therapy and immunosupressive agents. 3 patients were performed acute peritoneal dialysis and 2 patients were given plasmapheresis. At the last follow up, 1 patient was dead, 4 patients had elevated serum creatinin, 2 of these 4 patients were on chronic ambulatory peritoneal dialysis and 6 patients had normal renal function. Conclusion: Rapidly progressive glomerulonephritis is a medical emergency that requires very rapid diagnosis, classification, and therapy. Appropriate therapy selected on the basis of underlying disease mechanism can substantially improve renal survival. (J. Korean Soc Pediatr Nephrol 2001 ; 5 : 78-86)

  • PDF

Off Pump Total Arterial Myocardial Revascularization (동맥 도관만을 이용하여 체외심폐순환 없이 시행한 관상동맥우회술)

  • Youn Young Nam;Lee Kyo Joon;Lee Gy Jong;Joo Hyun Chul;Lim Sang Hyun;Kim Seung Ho;Kwak Young Lan;Yoo Kyung Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.349-356
    • /
    • 2005
  • Background: Arterial conduits using in coronary artery bypass grafting (CABG) have been known a great long term patency rates, and improved short and long term clinical outcomes. It has been reported that Off pump CABG has better clinical results than CABG using cardiopulmonary bypass. To evaluate the advantage of arterial conduits over venous conduits and to avoid the adverse effects of cardiopulmonary bypass, we performed total arterial Off pump CABG. Material and Method: From January 2001 to October 2004, Off pump CABG using only arterial conduits was performed on 325 patients with a mean age of $59.3\pm11.9$ years ($36\~83$). Mean ejection fraction was $55.4\pm14.0\%\;(15\~86).$ Angiography showed left main disease or triple-vessel disease in $81.9\%$ of the patients. Indications of using arterial conduits was stenosis $\ge50\%$ of left anterior descending artery, stenosis $\ge80\%$ of branches of left circumflex artery, and stenosis $\ge90\%$ of right coronary artery and its branches. Multi-slice computed tomography was performed on 194 patients to evaluate the short term patency rates. Result: A total of 928 distal anastomoses were performed and the average anastomoses per a patient were $2.86\pm0.78$. There was 1 operative mortality. Postoperative complications were mediastinitis in 6 patients ($1.8\%$), renal failure in 4 patients ($1.2\%$), perioperative myocardial infarction in 3 patients ($0.9\%$), reoperation for bleeding in 3 patients ($0.9\%$). There was no postoperative stroke. Patency rate of arterial conduits was $99.3\%$ (581/585). There were 4 stenoses or competitive flows in 2 radial arteries and 2 right internal mammary arteries. Conclusion: Total arterial Off pump CABG appears to be safe, showing a low surgical mortality and morbidity and excellent short term patency rates of arterial conduits.