• 제목/요약/키워드: restorative material

검색결과 406건 처리시간 0.018초

수종 치근단 역충전재가 치근단 조직 함유에 미치는 영향 (EFFECTS OF SOME ROOT END FILLING MATERIALS ON THE REPAIR OF PERIRADICULAR TISSUE)

  • 조용범;홍찬의;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.17-32
    • /
    • 1995
  • The purpose of this study was to examine the response of periradicular tissues to amalgam, IRM, Ketac-silver and MTA(Mineral trioxide aggregate) used as a root end fillings. The lower third and fourth premolars of 5 mongrel dogs were used. Each root was resected, followed by root end fillings with experimental materials. The animals were sacrificed after 16 weeks and radiographic and histologic results were evaluated. The results were as follows : 1. Severe inflammation around apex and disruption of cortical were noted in relation to the amalgam. 2. With IRM, there was severe infiltration of inflammatory cells around filling material, but healing of cortical bone was noted. 3. With Ketac-silver, mild inflammation and thick band of fibrous connetive tissue around filling material were seen, with a cortical bone healing. 4. In case of MTA, complete regeneration of cortical bone was seen, and free MTA was surrounded with newly formed bone tissue.

  • PDF

Evaluation of the rat tissue reaction to experimental new resin cement and mineral trioxide aggregate cement

  • Yang, Won-Kyung;Ko, Hyun-Jung;Kim, Mi-Ri
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.194-200
    • /
    • 2012
  • Objectives: New resin cement (NRC) has been developed as a root repairing material and the material is composed of organic resin matrix and inorganic powders. The aim of this study was to compare the rat subcutaneous tissue response to NRC and mineral trioxide aggregate (MTA) cement and to investigate the tissue toxicity of both materials. Materials and Methods: Sixty rats received two polyethylene tube-implants in dorsal subcutaneous regions, MTA and NRC specimens. Twenty rats were sacrificed respectively at 1, 4 and 8 wk after implantation and sectioned to 5 ${\mu}m$ thickness and stained with Hematoxylin-Eosin (H-E) or von-Kossa staining. The condition of tissue adjacent to the implanted materials and the extent of inflammation to each implant were evaluated by two examiners who were unaware of the type of implanted materials in the tissues. Data were statistically analyzed with paired t-test (p < 0.05). Results: In specimens implanted with both NRC and MTA, severe inflammatory reactions were present at one wk, which decreased with time. At eighth wk, MTA implanted tissue showed mild inflammatory reaction, while there were moderate inflammatory reactions in NRC implanted tissue, respectively. In NRC group, von-Kossa staining showed more calcification materials than MTA group at eighth wk. Conclusions: It was concluded that the calcium reservoir capability of NRC may contribute to mineralization of the tissues.

광중합기의 광도와 시간에 따른 글래스 아이오노머의 치수내 온도변화 (INTRAPULPAL TEMPERATURE CHANGE OF GLASS IONOMER ACCORDING TO LIGHT CURING INTENSITY AND CURING TIME)

  • 김희량;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.387-392
    • /
    • 2001
  • When cavity floor is near the pulp, polymerization of light-activated restorations results in temperature increase. This temperature increase cause by both the exothermic reaction process and the energy absorbed during irradiation. Therefore instating base is required. Most frequently used insulating base is glass ionmer. The purpose of this study was to evaluate intrapulpal temperature changes of glass ionomer according to various curing intensity and curing time. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn for evaluating of temperature changes. glass ionomer material was placed in 2mm. total curing time was 40s: continuous 40s, intermittent 20s, intermittent 10s. Glass ionomer material was cured with 300mW/$\textrm{cm}^2$, 550mW/$\textrm{cm}^2$ light curing unit. The results were as follows : 1. Temperature in pulp increased as curing unit power is increased. 2. Temperature in pulp more increased continuous emission than intermittent emission.

  • PDF

가시광선(可視光線)이 복합(複合)레진의 경화(硬化)에 미치는 효과(效果)에 관(關)한 연구(硏究) (A STUDY ON THE DEPTH OF POLYMERIZATION OF VISIBLE LIGHT ACTIVATED COMPOSITE RESINS)

  • 정세준;이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.145-152
    • /
    • 1984
  • The purpose of this study was to compare combinations of the four visible light irradiating appliances (Translux, Heliomat, Pluraflex HL 150, Omega) and the four visible light activated composite resins (Durafil, Heliosit, Plurafil-super, Silux) to determine the depth of polymerization of each combination. Twenty samples were made with Durafil. Five samples were polymerized for 20 seconds using Translux, five with Heliomat, five with Pluraflex HL 150, five with Omega. Twenty samples were made with Heliosit, twenty with Plurafil-super, and twenty samples with Silux. A 20-second polymerization time was applied with each of 4 visible light irradiating appliances to 5 samples of each material. Eighty samples were treated in a like manner, but polymerization was extended to 40 seconds. Depth of polymerization were measured with caliper. The results were as follows. 1) Of the two time exposures, 40-second exposure provided a significantly greater depth of polymerization than 20-second for each light with each material. 2) Durafill-Translux system showed minimum depth of polymerization, and Plurafil-Pluraflex system showed maximum depth of polymerization. 3) Visible light irradiating appliances were able to harden the resins cured by tire visible lights of other makers' apparatuses. 4) In all circumstances, depth of polymerization was between 3.0-3.8mm.

  • PDF

인산(隣酸) 에스텔계 접착성(接着性) 레진의 치수반응(齒髓反應)에 관(關)한 병리조직학적(病理組織學的) 연구(硏究) (A HISTOPATHOLOGICAL STUDY ON THE PULP REACTION OF ADHESIVE RESINS AS PHOSPHORIC ESTER SYSTEM)

  • 김철호
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.7-16
    • /
    • 1984
  • The purpose of this study was to investigate the pulpal responses to adhesive resins as phosphoric ester system: "Clearfil F II" (Composite filling material), "Panavia EX" (Composite cementing Material) and "Silar" (Microfilled Compsoite resin) comparing with Zinc-Oxide-Eugenol cement. Total 70 cavities of the permanent healthy teeth from 5 dogs were prepared and placed with experimental resins and Zinc-Oxide-Eugenol cement as control. The dogs were sarificed at 5 intervals of 3 days, one, two, four, six weeks. The specimens were routinely prepared and stained by Hematoxylin-Eosin. Followings were the results obtained through microscopic examination. 1. In cases of Clearfil F II and Panavia EX without etching and lining, pulp response in the early stage showed more severe vascular congestion and hemorrhage than that of Zinc-Oxide-Engenol cement. 2. The pulp response of totally etched cases was similar to that of unetched cases in the groups of Clearfil F II and Panavia EX. 3. The cases of Clearfil F II and Panavia EX with enamel etching showed no significant histologic change compared to that of total cavity etching. 4. The Silar case with total etching showed retarded tendency of histologic recovery compared to Clearfil F II and Panavia EX group. 5. Generally, pulp responses of experimental groups were not severe and the six week case showed the evidence of a histologic recovery.

  • PDF

구치부 수복용 복합레진의 파괴특성에 관한 Acoustic Emission 연구 (ACOUSTIC EMISSION ANALYSIS FOR FRACTURE CHARACTERISTICS OF DENTAL POSTERIOR COMPOSITES)

  • 박진훈;김교한
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.153-165
    • /
    • 1992
  • Dental composite resin is a kind of the particle - reinforced composite material, and is widely used in recent dental restoration of anterior and posterior tooth region. The purpose of this study was to investigate the fracture behaviour according to volume fractions and external findings of the filler particles for better interpretation of the fracture characteristics of posterior dental composite resins by analytic method of fracture mechanics. The plane strain fracture toughness($K_{IC}$) and Acoustic Emission were determined with three - point bending test using the single edge notch specimen according to the ASTM - E399, and its analyzed data was compared with filler volume fractions derived from the standard ashing test and scanning electron fractographs of each specimen including the unfilled experimental resin as a control. The results were that the value of fracture toughness of the composite resin material was in the range from 0.85 MPa$\sqrt{m}$ to 1.60 MPa$\sqrt{m}$ and was higher than the value of the unfilled experimental resin, and the fracture behaviours dervied from Acoustic Emission analysis show prominent differences according to the volume fraction and the size of filler particles used in each composite resin. The degree of resistance against crack propagation seems to be increase and the fractographs demonstrate the high degree of surface roughness and irregularity according with the increase of fracture toughness value.

  • PDF

Effect of calcium hydroxide on inflammatory root resorption and ankylosis in replanted teeth compared with other intracanal materials: a review

  • Jahromi, Maryam Zare;Kalantar Motamedi, Mahmood Reza
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.32.1-32.13
    • /
    • 2019
  • Calcium hydroxide (CH) is the gold-standard intracanal dressing for teeth subjected to traumatic avulsion. A common complication after the replantation of avulsed teeth is root resorption (RR). The current review was conducted to compare the effect of CH with that of other intracanal medications and filling materials on inflammatory RR and replacement RR (ankylosis) in replanted teeth. The PubMed and Scopus databases were searched through June 2018 using specific keywords related to the title of the present article. The materials that were compared to CH were in 2 categories: 1) mineral trioxide aggregate (MTA) and endodontic sealers as permanent filling materials for single-visit treatment, and 2) Ledermix, bisphosphonates, acetazolamide, indomethacin, gallium nitrate, and enamel matrix-derived protein (Emdogain) as intracanal medicaments for multiple-visit management of avulsed teeth prior to the final obturation. MTA can be used as a single-visit root filling material; however, there are limited data on its efficacy due to a lack of clinical trials. Ledermix and acetazolamide were comparable to CH in reducing RR. Emdogain seems to be an interesting material, but the data supporting its use as an intracanal medication remain very limited. The conclusions drawn in this study were limited by the insufficiency of clinical trials.

Surface changes of metal alloys and high-strength ceramics after ultrasonic scaling and intraoral polishing

  • Yoon, Hyung-In;Noh, Hyo-Mi;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.188-194
    • /
    • 2017
  • PURPOSE. This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. MATERIALS AND METHODS. A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. RESULTS. Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were $3.02{\pm}0.34{\mu}m$, $2.44{\pm}0.72{\mu}m$, and $3.49{\pm}0.72{\mu}m$, respectively. Surface roughness of lithium disilicate increased from $2.35{\pm}1.05{\mu}m$ (pristine) to $28.54{\pm}9.64{\mu}m$ (scaling), and further increased after polishing ($56.66{\pm}9.12{\mu}m$, P<.05). The zirconia showed the most increase in roughness after scaling (from $1.65{\pm}0.42{\mu}m$ to $101.37{\pm}18.75{\mu}m$), while its surface roughness decreased after polishing ($29.57{\pm}18.86{\mu}m$, P<.05). CONCLUSION. Ultrasonic scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate.

Evaluation of the repair capacities and color stabilities of a resin nanoceramic and hybrid CAD/CAM blocks

  • Bahadir, Hasibe Sevilay;Bayraktar, Yusuf
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.140-149
    • /
    • 2020
  • PURPOSE. This study evaluated the color stabilities of two computer-aided design and computer-aided manufacturing (CAD/CAM) blocks and a nanofill composite resin and the microtensile bond strength (µTBS) between the materials. MATERIALS AND METHODS. Twelve specimens of 4 mm height were prepared for both Lava Ultimate (L) and Vita Enamic (E) CAD/CAM blocks. Half of the specimens were thermocycled (10,000 cycle, 5° to 55℃) for each material. Both thermocycled and non-thermocycled specimens were surface treated with one of the three different methods (Er,Cr:YSGG laser, bur, or control). For each surface treatment group, one of the thermocycled and one of non-thermocycled specimens were restored using silane (Ceramic Primer II), universal adhesive (Single Bond Universal), and nanofill composite resin of 4-mm height (Filtek Ultimate). The other specimens were restored with the same procedure without using silane. For each group, 1 × 1 × 8 mm bar specimens were prepared using a microcutting device. Bar specimens were thermocycled (10,000 cycle, 5° to 55℃) and microtensile tests were performed. Staining of the materials in coffee solution was also compared using a spectrophotometer. Data were analyzed using one-way ANOVA, t-test and post-hoc Scheffe tests. RESULTS. µTBS were found similar between the thermocycled and non-thermocycled groups (P>.05). The highest µTBS (20.818 MPa) was found in the non-thermocycled, bur-ground, silane-applied E group. Silane increased µTBS at some E groups (P<.05). Composite resin specimens showed more staining than CAD/CAM blocks (P<.05). CONCLUSION. CAD/CAM blocks can be repaired with composite resins after proper surface treatments. Using silane is recommended in repair process. Color differences may be shown between CAD/CAM blocks and the nanofill composite after a certain time period.

Surface deterioration of monolithic CAD/CAM restorative materials after artificial abrasive toothbrushing

  • Sen, Nazmiye;Tuncelli, Betul;Guller, Gultekin
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.271-278
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the effect of abrasive toothbrushing on the surface properties of monolithic computer-assisted design and computer-assisted manufacturing (CAD/CAM) materials stored in food-simulating liquids (FSLs). MATERIALS AND METHODS. Fourty-eight disk-shaped test specimens of each material (Paradigm MZ100/PMZ, Lava Ultimate/LU, Vita Enamic/VE, and Vita Mark II/VMII) with a diameter of 10.0 mm and a thickness of $3.0{\pm}0.05mm$ were prepared. Specimens were divided into 4 subgroups (n=12) and stored in air, distilled water, 0.02 M citric acid, or 75% ethanol/water solution for 7 days at $36.5^{\circ}C$. Then, the specimens were brushed in a multi-station brushing machine under a vertical load of 2.0 N for 3 hours. Surface gloss (GU), roughness (Ra), and hardness (Vickers [VHN]) were measured after storage and brushing simulation. The data sets were statistically analyzed with 2 and 3-way ANOVAs followed by the Tukey's post-hoc comparisons (${\alpha}=.05$). RESULTS. Statistically significant difference was found among the materials concerning the results of surface properties. VMII showed the highest VHN, while PMZ produced the lowest. Storage in FSLs significantly affected the VHN of PMZ and LU. VMII showed the lowest Ra and highest GU irrespective of FSLs and of abrasive toothbrushing. VE, LU, and PMZ produced significant decrease in GU and increase in Ra after toothbrushing. CONCLUSION. Surface properties of monolithic CAD/CAM restorative materials were differently affected by the storage media and abrasive toothbrushing.