• Title/Summary/Keyword: response in steady state

Search Result 600, Processing Time 0.03 seconds

Effects of Residual Hearing on the Auditory Steady State Response for Cochlear Implantation in Children

  • Kim, Young Seok;Han, Sun A;Woo, Hyunjun;Suh, Myung-Whan;Lee, Jun Ho;Oh, Seung Ha;Park, Moo Kyun
    • Korean Journal of Audiology
    • /
    • v.23 no.3
    • /
    • pp.153-159
    • /
    • 2019
  • Background and Objectives: We aim to explore the effects of residual auditory steady state response (ASSR) on cochlear implantation (CI) outcomes in children lacking auditory brainstem responses (ABRs). Subjects and Methods: We retrospectively reviewed the data of child CI recipients lacking ABRs. All ears were divided into two groups: with residual ASSR and without ASSR. For each frequency, the T- and C-levels and the electrical dynamic ranges of postoperative 3-month and 1-year mappings were compared between the groups. To evaluate speech perception, patients who received simultaneous bilateral CIs were divided into two groups: group 1 exhibited responses at all frequencies in both ears; in group 2, at least one ear evidenced no response. The Categories of Auditory Perception (CAP) and Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) scores were compared between the groups. Results: We enrolled 16 patients. At 2 kHz, the postoperative 3-month and 1-year T-levels of patients with residual hearing were lower than those of hearing loss group (p=0.001, p=0.035). In residual hearing group, the ASSR threshold correlated positively with the postoperative 1-year T-level (p=0.012, R2=0.276) and C-level (p=0.002, R2=0.374). Of 10 simultaneous bilateral CI recipients, 5 exhibited ASSRs at all frequencies and the other 5 showed no response at ≥1 frequency. The latter had higher CAP scores at the postoperative 1-year (p=0.018). Conclusions: In children exhibiting hearing loss in ABR testing, residual hearing at 2 kHz ASSR correlated positively with the post-CI T-level. Those with ASSRs at all frequencies had significantly lower CAP scores at the postoperative 1year. CI should not be delayed when marginal residual hearing is evident in ASSR.

Development of an Electric Circuit Transient Analogy Model in a Vertical Closed Loop Ground Heat Exchanger (수직밀폐형 지중열교환기의 회로 과도해석 상사모델 개발)

  • Kim, Won-Uk;Park, Hong-Hee;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.306-314
    • /
    • 2012
  • Several numerical or analytical models have been proposed to analyze the thermal response of vertical ground heat exchangers (GHEX). However, most models are valid only after several hours of operation since they neglect the heat capacity of the borehole. Recently, the short time response of the GHEX became important in system simulation to improve efficiency. In this paper, a simple new method to evaluate the short time response of the GHEX by using an analogy model of electric circuit transient analysis was presented. The new transient heat exchanger model adopting the concept of thermal capacitance of the borehole as well as the steady-state thermal resistance showed the transient thermal resistance of the borehole. The model was validated by in-situ thermal response test and then compared with the DST model of the TRNSYS program.

Optimal Control Design-based Gain Selection of an LCL-filtered Grid-connected Inverter in State-Space under Distorted Grid Environment

  • Tran, Vi-Thuy;Yoon, Seung-Jin;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.344-345
    • /
    • 2018
  • In order to alleviate the negative impacts of harmonically distorted grid condition on grid-connect inverters, an optimal control design-based gain selection scheme of an LCL-filtered grid-connected inverter and its ability to compensate selective harmonics are presented in this paper. By incorporating resonant terms into the control structure in the state-space to provide infinity gain at selected frequencies, the proposed control offers an excellent steady-state response even under distorted grid voltage. The proposed control scheme is achieved by using a state feedback controller for stabilization purpose and by augmenting the resonant terms as well as intergral term into a control structure for reference tracking and harmonic compensation. Furthermore, the optimal linear quadratic control approach is adopted for choosing an optimal feedback gain to ensure an asymptotic stability of the whole system. A discrete-time full state observer is also introduced into the proposed control scheme for the purpose of reducing a total number of sensors used in the inverter system. The simulation results are given to prove the effectiveness and validity of the proposed control scheme.

  • PDF

EFFECT OF TIME DELAY IN AN AUTOTROPH-HERBIVORE SYSTEM WITH NUTRIENT CYCLING

  • Das, Kalyan;Sarkar, A.K.
    • Journal of applied mathematics & informatics
    • /
    • v.5 no.3
    • /
    • pp.597-606
    • /
    • 1998
  • In the present study we consider a mathematical model of a non-interactive type autotroph-herbivore system in which the amount of autotroph biomass consumed by the herbivore is assumed to follow a Holling type II functional response. We have also incorpo-rated discrete time delays in the numerical response term to represent a delay due to gestation and in the recycling term which represent a delay due to gestation and in the recycling term which represents the time required for bacterial decomposition. We have derived con-dition for global asymptotic stability of the model in the absence of delays. Conditions for delay-induced asymptotic stability of the steady state are also derived. The length of the delay preserving stability has been estimated and interpreted ecologically.

UPFC Performance Control in Distribution Networks for DG Sources in the Islanding

  • Fandawi, Ahmed;Nazarpour, Daryoosh
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.303-309
    • /
    • 2017
  • The flexible AC transmission system (FACTS) provides a new advanced technology solution to improve the flexibility, controllability, and stability of a power system. The unified power flow controller (UPFC) is outstanding for regulating power flow in the FACTS; it can control the real power, reactive power, and node voltage of distribution networks. This paper investigates the performance of the UPFC for power flow control with a series of step changes in rapid succession in a power system steady state and the response of the UPFC to distribution network faults and islanding mode. Simulation was carried out using the MATLAB's simulink sim power systems toolbox. The results, which were carried out on a 5-bus test system and a 4-bus multi-machine electric power system, show clearly the effectiveness and viability of UPFC in rapid response and independent control of the real and reactive power flows and oscillation damping [6].

Regulation of Intestinal Immune System by Dendritic Cells

  • Ko, Hyun-Jeong;Chang, Sun-Young
    • IMMUNE NETWORK
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Innate immune cells survey antigenic materials beneath our body surfaces and provide a front-line response to internal and external danger signals. Dendritic cells (DCs), a subset of innate immune cells, are critical sentinels that perform multiple roles in immune responses, from acting as principal modulators to priming an adaptive immune response through antigen-specific signaling. In the gut, DCs meet exogenous, non-harmful food antigens as well as vast commensal microbes under steady-state conditions. In other instances, they must combat pathogenic microbes to prevent infections. In this review, we focus on the function of intestinal DCs in maintaining intestinal immune homeostasis. Specifically, we describe how intestinal DCs affect IgA production from B cells and influence the generation of unique subsets of T cell.

Deadbeat Control with a Repetitive Predictor for Three-Level Active Power Filters

  • He, Yingjie;Liu, Jinjun;Tang, Jian;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.583-590
    • /
    • 2011
  • Three-level NPC inverters have been put into practical use for years especially in high voltage high power grids. This paper researches three-level active power filters (APFs). In this paper a mathematical model in the d-q coordinates is presented for 3-phase 3-wire NPC APFs. The deadbeat control scheme is obtained by using state equations. Canceling the delay of one sampling period and providing the predictive value of the harmonic current is a key problem of the deadbeat control. Based on this deadbeat control, the predictive output current value is obtained by the state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by the repetitive predictor synchronously. The repetitive predictor can achieve a better prediction of the harmonic current with the same sampling frequency, thus improving the overall performance of the system. The experiment results indicate that the steady-state accuracy and the dynamic response are both satisfying when the proposed control scheme is implemented.

Groundwater Flow Model of Igsan Area (익산 지역의 지하수 유동 모델)

  • Hamm, Se Yeong;Kim, Youn Ki
    • Economic and Environmental Geology
    • /
    • v.22 no.4
    • /
    • pp.381-393
    • /
    • 1989
  • Hydrogeological modelling was performed to evaluate groundwater flow system in Igsan Area. The study area extends over $790km^2$. The geology consists of Jurassic Daebo granite and gneissose granite and Precambrian metamorphic rocks. The capability of pumping yield is the highest in gneissose granite region among them due to comparatively thick weathered zone with thickness ranging from 10m to 25m. The Colorado State University Finite Difference Model was used for the model simulation. The model was divided into 28 rows and 31 columns with variable grid spacing. The model was calibrated under steady-state and unsteady-state conditions. In the steady-state simulation, the model results were compared with measured water table contours in September 1985 with determining hydraulic conductivities and net recharge rates during rainy season. Unsteady state simulation was done to know the aquifer response due to groundwater abstraction. The non- steady state calibration was conducted to determine the distribution and magnitudes of specific yields and discharge/recharge rates during dry season as matching water level altitudes in May 1986. The calibrated model was used to simulate water level vaiation caused by groundwater withdrawal and natural recharge from 1 October, 1985 until 30 September, 1995. The calibrated model can be used to groundwater development schemes on regional groundwater levels, but it cannot be used to simulate local groundwater level change at a specific site.

  • PDF

The Design of MRAC with Fuzzy Adaptation Law (퍼지 적응 법칙을 갖는 기준모델 적응제어기 설계)

  • Cho, Jong-Hoon;Kwon, Hyuk-Jin;Seo, Seung-Hyun;Moon, Dong-Uk;Nam, Moon-Hyon
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.685-688
    • /
    • 1995
  • In this paper we proposed new scheme replacing adaptive mechanism part in MRAC by fuzzy logic in order to improve transient response in adaptive control system. Conventional adaptive control system has good performance in steady state but it has large error or problem with rise time in transient state. We need to increase adaptation gain of control variable but it causes robustness problem that makes ststem unstable for set-point, load-variation, and dynamic change. To demonstrate presented FTAC(fuzzy tunning adaptive control)'s superiority, presented method is introduced for a class of SISO systems and compare with MRAC. By analyzing simulation result, we can see transient response is improved and the system is not affected by disturbance in proposed method in comparison to MRAC.

  • PDF

A study on charging and electrical stability characteristics with no-insulation and metal insulation in form of racetrack type coils

  • Quach, Huu Luong;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.3
    • /
    • pp.13-19
    • /
    • 2020
  • This study presents the experiment and simulation results on the magnetic field response and electrical stability behaviors of no-insulation (NI) and metal insulation with stainless steel tape (MI-SS) which wound in form of racetrack type coils. First of all, the structural design of the racetrack type bobbin was shown along with its parameters. Then, the current-voltage tests were carried out to measure the critical current of both test coils. Also, the sudden discharging and charging tests were performed in the steady state to estimate the decay field time and magnetic field response, respectively. Finally, the overcurrent tests were conducted in the transient state to investigate the electrical stability of these test coils. Based on the experimental results, the contact surface resistances were calculated and applied to the field coils (FCs) of 10-MW-class second generation high temperature superconducting generator (2G HTSG) used in wind offshore environment. The charging delay time and electrical stability for NI and MI-SS HTS FCs of 10-MW-class 2G HTSG are analyzed by the equivalent circuit model and the key parameters which were obtained from the electromagnetic finite element analysis results.