• Title/Summary/Keyword: resonant sensor

Search Result 215, Processing Time 0.552 seconds

Sensitivity Characteristics of Acoustic Emission(AE) Sensor using the Lead-free (Na1,K)NbO3 Ceramics (무연 (Na1,K)NbO3 계 세라믹스를 이용한 AE센서의 감도특성)

  • Yoo, Ju-Hyun;Lee, Gab-Soo;Hong, Jae-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.3
    • /
    • pp.218-222
    • /
    • 2007
  • In this study, Acoustic emission(AE) sensors were fabricated using lead-free piezoelectric ceramics for prohibiting environmental pollution. Structure of AE sensors were designed as Langvin type air backing form. Here, the piezoelectic element was used as PZT(EC-65)(AE1) and NKN(AE2), respectively. The measured resonant frequency, the maximum sensitivity frequency and sensitivity of AE sensors were as follows ; 143 kHz, 29.4 kHz and 69.3 dB in AE1 and 179 kHz, 29.4 kHz and 66.3dB in AE2, respectively.

Measurement of plastic anisotropy of cold rolled steel sheets using electromagnetic acoustic transducer (EMAT를 이용한 냉연강판의 소성이방성 측정)

  • 황의찬;장경영;안봉영;이승석;김수광;김상영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.383-388
    • /
    • 1994
  • Ultrasonic sensor for evaluating plastic anisotropy was developed. Magnetostrictive type EMAT is sensor to transmit and receive the Lamb wave using magnetostriction. It is suitable for on line processing because of transmitting and receiving ultrasonic without contact ODCs(orientation distribution coefficients), W $_{400}$. W $_{420}$. W $_{440}$. were respectively calculated using zeroth order Lamb wave velocities, the calculated ODCs was used for evaluating plastic anisotropy, the results was compared for mean values of destructive tests. Besides, the Lorentz EMAT for generating longitudinal wave and two shear waves simultaneously and the Lorentz type EMAT for measuring SH wave velocities were made. ODCs were calculated using the measured resonant modes and velocities. the results of two methods show possibility of an line processing measurement.

  • PDF

Sensitivity Analysis for Specifications of Silicon-on-Insulator (SOI) Slot Optical Waveguide-based Single and Add-drop Channel Ring-resonant Biochemical Integrated Optical Sensors (SOI 슬롯 광 도파로 기반 단일 및 삽입-분기 채널 링-공진형 바이오·케미컬 집적광학 센서의 제원에 대한 감도 해석)

  • Jang, Jaesik;Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.107-114
    • /
    • 2022
  • The effects of ring radius and coupling spacing on the free spectral range (FSR), full width at half maximum (FWHM), quality factor, and sensitivity of single-channel and add-drop channel slot ring resonators were systematically investigated using FIMMPROP and PICWAVE numerical software. The single-channel ring resonator exhibited better characteristics, namely, a wider FSR and narrower FWHM compared with the add-drop structure; thus, it was evaluated to be more suitable for biochemical sensors. The FSR, FWHM, quality factor, and sensitivity for a single channel ring resonator with a radius of 59.4 ㎛ and coupling gap of 0.5 ㎛ were 2.4 nm, 0.087 nm, 17677, and 550 [nm/RIU], respectively.

Design of the Rain Sensor using a Coaxial Cavity Resonator (동축 공동 공진기를 이용한 물방울 감지 센서 설계에 관한 연구)

  • Lee, Yun-Min;Kim, Jin-Kook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.5
    • /
    • pp.223-228
    • /
    • 2018
  • In this paper the water sensor using a coaxial cavity resonator is designed and manufactured. The water sensor which can sense water drop linearly has been constructed with voltage controlled oscillator(VCO), coaxial cavity resonator, RF switch, RF detector, A/D converter, DAC and micro controller. The operating frequency range of the designed water sensor is from 2.5GHz to 3.2GHz and the input voltage and current source are 24[V/DC] and 1[A]. The designed sensor circuit includes VCO, RF switch, RF detector which varies the frequency characteristics of the devices in the high frequency of 3GHz. And so we should correct the error of the frequency characteristics of those devices in the sensor circuit. To do this, we make the reference path which switches the signals to the RF detector directly without sending it to the resonator. According to the result of simulation and measurement, we can see that there is 0-50MHz difference between simulated resonator frequency and manufactured resonator frequency.

Design of Microstrip Defected Ground Structure-based Sensor with Enhanced-Sensitivity for Permittivity Measurement (유전율 측정을 위한 고감도 마이크로스트립 결함 접지 구조 기반 센서 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.1
    • /
    • pp.69-76
    • /
    • 2019
  • In this paper, a design method for an enhanced-sensitivity microwave sensor based on microstrip defected ground structure was studied for the permittivity measurement of planar dielectric substrates. The proposed sensor was designed by modifying the ridge structure of an H-shaped aperture into the shape of a capacitor symbol. The sensitivity of the proposed sensor was compared with that of a conventional sensor based on a double-ring complementary split ring resonator(DR-CSRR). Two sensors were designed and fabricated on a 0.76-mm-thick RF-35 substrate so that the transmission coefficient would resonate at 1.5 GHz in the absence of the substrate under test. Five types of taconic substrates with a relative permittivity ranging from 2.17 to 10.2 were selected asthe substrate under test. Experiment results show that the sensitivity of the proposed sensor, which is measured by the shift in the resonant frequency of the transmission coefficient, is 1.31 to 1.62 times higher than that of the conventional DR-CSRR-based sensor.

Piezoelectric immunosensor for the detection of Edwardsiellosis

  • Hong, Sung-Rok;Choi, Suk-Jung;Jeong, Hyun-Do;Hong, Su-Hee
    • Journal of fish pathology
    • /
    • v.20 no.3
    • /
    • pp.307-313
    • /
    • 2007
  • In this study, a QCM biosensor was made to detect Edwardsiella tarda (E. tarda) using a specific antibody. A 9 MHz AT-cut piezoelectric wafer layered with two gold electrodes of 5mm diameter had a reproducibility of 0.1 Hz in frequency response and was used as the transducer of the QCM biosensor. Self assembled layer (SAM) was conformed on a quartz crystal by treating with 3-mer-captopropionic acid (MPA) and activated with N-ethyl-N'-(3-dimethyl-aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The resulting NHS group was further converted to hydrazide by the reaction with hydrazine. Aldehyde group was introduced into the carbohydrate moiety of anti-E. tarda antibody by the reaction with periodic acid and was used to immobilise the antibody through the reaction with hydrazide group on the electrode surface. A baseline was established in the presence of phosphate-buffered saline (PBS) and a resonant frequency (F1) was measured. Sample was added to the sensor surface and second resonant frequency (F2) was measured after unbound substances were washed out with PBS several times. Finally, the frequency shift (ΔF) representing the mass change was calculated by subtracting F2 from F1. After adding the oxidized anti-E. tarda antibody to the electrode surface containing hydrazide group, frequency shift of 288.811.4 Hz (mean S.E) was observed, thus proving that considerable amount of antibody was immobilized. In the immunoassay test, the frequency shift of 1877.75 Hz, 580.67 Hz, 221.39 Hz, 7.671.83 Hz (mean S.E) were observed at doses of 1000, 500, 100, 50 g of bacterial cells, respectively. It was also demonstrated that the prepared sensor chip was stable enough to withstand repeated surface regeneration with 0.2 M Tris-glycine and 1 % DMSO, pH 2.3 more than ten times.

Electrochemical Determination of Glucose in Sea Water (해수 중 글루코오스 농도의 전기화학적 측정)

  • 김영한
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.73.2-77
    • /
    • 2000
  • A possibility of the implementation of a quartz crystal sensor to the detennination of chemical oxygen demand is examined by checking the electrochemical behavior of the sensor in a glucose solution. Since the surface of a quartz crystal has to be oxidized, a relatively active metal is coated on the surface of a usual 9 MHz AT-cut crystal. The electrochemical behavior is investigated by measuring the changes of current, resonant frequency and resonant resistance while a constant potential is applied. The crystal is installed in a specially designed container, and a QUartz crystal analyzer is utilized to measure the frequency and resistance simultaneously. The variations of the measurements are examined at different concentrations of glucose solution and the effect of the concentration is analyzed to find a proper relation between the concentration and the measurements. It is fOlmd that a linear relation between the concentration of less than 900 Dpm and the peak current when a constant potential of -180 m V vs. Ag/ AgCI reference is applied.

  • PDF

Characteristics of Coaxial Typed Magnetic Sensor Using Amorphous Wire (자성와이어를 이용한 동축케이블형 자계센서의 특성)

  • Kim, Y.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.55-59
    • /
    • 2007
  • Co-based amorphous magnetic wire with a diameter of $125{\mu}m$ and a length of 40 mm was used as an inner conductor of a coaxial cable to construct a magnetic sensor. Sensor characteristics was measured up to 3 GHz with applied up to 60 Oe by using network analyzer. Frequency dependence of impedance for this sensor was very close to the impedance resonant pattern of transmission line and 250 MHz was obtained as a 1/4 wavelength without external magnetic field. Large impedance change was measured in the magnetic field range between 0 Oe and 1 Oe, which was influenced by permeability change of magnetic amorphous wire. Because ${\Delta}Z/{\Delta}H$ value of $300{\Omega}/Oe$ was obtained at 0.1 Oe, this coaxial cable with amorphous wire can be useful as a magnetic sensor.

Highly Sensitive Integrated Photonic Temperature Sensor Exploiting a Polymeric Microring Resonator (폴리머 마이크로링 공진기를 이용한 고감도 집적광학형 온도센서)

  • Lee, Hak-Soon;Kim, Gun-Duk;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.224-228
    • /
    • 2008
  • A highly sensitive integrated photonic temperature sensor was proposed and developed incorporating a polymeric microring resonator. The change in the ambient temperature was estimated by observing the shift in the resonant wavelength of the resonator induced via the thermooptic effect. For the purpose of enhancing its sensitivity, the sensor was built by implementing a polymeric resonator exhibiting a high thermooptic coefficient on a silicon substrate with a small coefficient of thermal expansion. For the range of from $20^{\circ}C$ to $30^{\circ}C$ near the room temperature, the fabricated sensor yielded a sensitivity of as high as 165 ${\pm}/^{\circ}C$ and a resolution of better than $0.1^{\circ}C$. And its performance was found to be hardly affected by the variation in the refractive index of the target analyte, which was applied to the surface of the sensor. It is hence expected that the sensor could be integrated with other refractormetric optical sensors, thereby compensating for the fatal error caused by the change in the ambient temperature.

Local/Global Structural Health Monitoring System Using Piezoelectric Sensors (압전센서를 이용한 구조물 국부/광역 손상 진단 시스템)

  • Kim, Byung-Soo;Kwon, Hyeok-Sang;Kim, Jin-Wook;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.308-317
    • /
    • 2009
  • In the present work, a sensor system composed of an oscillator sensor and a Lamb wave sensor is proposed for the purpose of structural health monitoring. The oscillator sensing system detecting the shift of a structural resonant frequency in proportion to the amount of defects in the structure is a pretty sensitive and simple device, but its detectable range is limited to its local zone. The Lamb wave sensor system, however, is applicable to global detection of the defects. This study is aimed at investigating the feasible combination of the two systems to exploits their merits simultaneously. The scheme to use PZT patches as the oscillator sensor as well as the Lamb wave sensor was proposed to identify the position, length and number of cracks by means of TOF and amplitude of signals, and its validity was confirmed through experiments.