• 제목/요약/키워드: resonance pattern

검색결과 381건 처리시간 0.034초

마이크로스피커 진동판의 등가탄성과 공명진동수의 연관성 (Relationship Between Geometrical Stiffness of Diaphragm and Resonance Frequency for Micro-speaker)

  • 오세진
    • 한국재료학회지
    • /
    • 제20권12호
    • /
    • pp.640-644
    • /
    • 2010
  • Information technology devices, such as cellular phones, MP3s and so on, due to restrictions of space, require thin and small micro-speakers to generate sound. The reduction of the size of micro-speakers has resulted in the decrease of sound quality, due to such factors as frequency range and sound pressure level. In this study, the acoustical properties of oval microspeakers has been studied as a function of pattern shape on the diaphragm. The other conditions of micro-speakers, except for the pattern, was not changed. When the pattern is present on the diaphragm and the shape of pattern was a whirlwind, the resonance frequency was reduced due to the decrease of tensile strength of diaphragm. The patterns presented in the semi-minor axis of diaphragm did not effect a change of resonance frequency. However, increasing the number of patterns in the semimajor axis of diaphragm became a reason for the decrease of resonance frequency on edge side. When the depth of pattern on edge side was increased, the resonance frequency was decreased due to reduction of geometrical stiffness. If the height of edge and dome were increased, the resonance frequency and geometrical stiffness rapidly increased. After reaching the maximum values, they began to decrease with the continuous increase of height.

A Unit-Cell Varying Pattern Reconfigurable Zeroth-order Resonance Antenna

  • Hyeon-Cheol Ki
    • International journal of advanced smart convergence
    • /
    • 제13권2호
    • /
    • pp.1-6
    • /
    • 2024
  • Reconfiguration and miniaturization of antennas have become key attributes in modern wireless communication systems. Reconfiguration of radiation pattern can alleviate the problems encountered in modern wireless communication systems such as multi-path problems. Physical limitation of miniaturization also can be overcome by using a zeroth-order resonance (ZOR) antenna based on metamaterial. In order to achieve reconfiguration and miniaturization of antennas at the same time, we propose a new pattern reconfigurable zeroth-order resonance (ZOR) antenna that reconfigures the radiation patterns by varying the position and the number of unit cells comprising the antenna. The antenna is fabricated in an equilateral triangular shaped symmetrical structure to increase pattern variety. This structure can easily provide eight different radiation patterns (two omnidirectional and six monopole like patterns).

Resonance Phenomenon and Its Effects of Laser Texture Disk

  • Choa, Sung-Hoon;Wang, Geng
    • Journal of Mechanical Science and Technology
    • /
    • 제14권7호
    • /
    • pp.744-751
    • /
    • 2000
  • To achieve lower flying height for high areal recording density, the laser zone texturing of the disk needs to be designed to reduce glide height. One problem of the laser bump design is that the regular laser bump pattern often produces glide resonance phenomenon, which leads to failure of the glide height test. However, it was found in this study that glide resonance is an intrinsic problem of the glide head used and resonance phenomenon depends on the type of the head slider, that is, the natural frequency of the slider body. Therefore, higher glide height or glide failure caused by glide resonance does not lead to head/media interface problem in the real drive operating conditions in which the data head is used. Pseudo-random bump pattern greatly reduces the glide resonance. Smaller bump pitch will also help to reduce the glide resonance. However, as bump spacing becomes smaller, glide height will be increased due to increased air pressure developed around the bumps. Lowering bump height is the most effect way to reduce glide avalanche.

  • PDF

생체 기에 대한 피동공명적인 연구 (Study on the wave resonance-stimultion and receptionfor the BIO-KI)

  • 류경호;김경철;이용태
    • 동의생리병리학회지
    • /
    • 제17권2호
    • /
    • pp.263-274
    • /
    • 2003
  • The present condition of study on the wave-resonance for the bio-KI is observed. And the probroms of reception attendent on the stimulation of wave is observed centering around the sensory organ. The results is as follows: In the wave-resonant stand point, the tendency of studying on KI is showed in the several field all over the world. Because it is originated radionics, the wave-resonant tools of MRA insistenting minute-magnetism-resonance-apparatus need the more severe data in the side of electric circuit. The wave resonance apparatus according to the frequency occurance transmits low-frequency's vibration ratio to the electric stimulating aspect. The wave-water is considered on the application of wave-resonance transcription on the water, and needs the comprehension of torsion-field level. The wave-stimulation of the bio-KI and the reception of the sensory-organ is observed the connection of the sensory-organ and it's corresponding wave. The informations recorded in the wave are distinguished patternly. And the several shaping waves transmit the informations each other through the resonnance. The wave theory is explained the LEE(理) as the wave-pattern and the KI(氣) as the revelation of the patterned-wave in the LEE-KI theory(理氣論), moreover the SHIN(神) as the information of the wave-pattern and the KI as the energy of the wave and the JEUNG(精) as the material of the wave in the JEUNG-KI-SHIN theory(精氣神論). In this point, the study on the wave-resonance of bio-KI is thought that it is significantly in the study method for oriental medicine. The sum of the wave makes the moving body and forms the universe. It means that the several wave patterns gather and form new field. The pattern is a kind of the information and the information is not materially. The information of wave-pattern is the arrangement and the combination of the material source.

Time Average ESPI와 Euler-Bernoulli 방정식에 의한 탄성계수 측정 (Determination of Elastic Modulus by Time Average ESPI and Euler-Bernoulli Equation)

  • 김경석;이항서;강영준;강기수
    • 한국정밀공학회지
    • /
    • 제24권7호
    • /
    • pp.69-74
    • /
    • 2007
  • The paper proposes a new sonic resonance test for a elastic modulus measurement which is based on time-average electronic speckle pattern interferometry(TA-ESPI) and Euler-Bernoulli equation. Previous measurement technique of elastic constant has the limitation of application for thin film or polymer material because contact to specimen affects the result. TA-ESPI has been developed as a non-contact optical measurement technique which can visualize resonance vibration mode shapes with whole-field. The maximum vibration amplitude at each vibration mode shape is a clue to find the resonance frequencies. The dynamic elastic constant of test material can be easily estimated from Euler-Bernoulli equation using the measured resonance frequencies. The proposed technique is able to give high accurate elastic modulus of materials through a simple experiment set up and analysis.

우주발사체용 UHF-대역 안테나의 표면결빙에 의한 영향분석 (Effect Analysis of Surface-Icing on the UHF-band Antenna for Space Launch Vehicle)

  • 황수설;오창열;마근수
    • 한국위성정보통신학회논문지
    • /
    • 제9권3호
    • /
    • pp.104-108
    • /
    • 2014
  • 한국형발사체의 표면에 장착되는 UHF-대역 안테나의 표면에 발생하는 결빙을 모델링하고, 이러한 결빙이 안테나의 공진주파수, 반사손실 및 방사패턴 등의 주요 특성에 미치는 영향을 분석하였다. 안테나 표면결빙을 모델링하기 위해 $-180^{\circ}C$의 얼음층에 대한 비유전율을 추출하였고 추출된 비유전율을 이용하여 안테나 표면결빙 모델을 제안하였다. 중심주파수가 UHF-대역인 안테나 표면에 1mm의 결빙이 되었을 경우의 표면결빙 모델을 적용하여 시뮬레이션 한 결과, 표면결빙에 의해 안테나의 공진주파수가 21MHz 하향 되었고, 방사패턴도 전 방향에 대해 전체적으로 10dB 이상의 성능저하가 발생되었다. 따라서 실제 안테나 표면에 결빙이 발생할 경우 안테나 성능에 심각한 영향을 미칠 것으로 판단된다.

자기공명분석기를 이용한 통증관리 (Clinical Study of Acute and Chronic Pain by the Application of Magnetic Resonance Analyser $I_{TM}$)

  • 박욱;진희철;조명현;윤석준;이진승;이정석;최석환;김성열
    • The Korean Journal of Pain
    • /
    • 제6권2호
    • /
    • pp.192-198
    • /
    • 1993
  • In 1984, a magnetic resonance spectrometer(magnetic resonance analyser, MRA $I_{TM}$) was developed by Sigrid Lipsett and Ronald J. Weinstock in the USA, Biomedical applications of the spectrometer have been examined by Dr. Hoang Van Duc(pathologist, USC), and Nakamura, et al(Japan). From their theoretical views, the biophysical functions of this machine are to analyse and synthesize a healthy tissue and organ resonance pattern, and to detect and correct an abnormal tissue and organ resonance pattern. All of the above functions are based on Quantum physics. The healthy tissue and organ resonance patterns are predetermined as standard magnetic resonance patterns by digitizing values based on peak resonance emissions(response levels or high pitched echo-sounds amplified via human body). In clinical practice, a counter or neutralizing resonance pattern calculated by the spectrometer can correct a phase-shifted resonance pattern(response levels or low pitched echo-sounds) of a diseased tissue and organ. By administering the counter resonance pattern into the site of pain and trigger point, it is possible to readjust the phase-shifted resonance pattern and then to alleviate pain through regulation of the neurotransmitter function of the nervous system. For assessing clinical effectiveness of pain relief with MRA $I_{TM}$ this study was designed to estimate pain intensity by the patient's subjective verbal rating scale(VRS such as graded to no pain, mild, moderate and severe) before application of it, to evaluate an amount of pain relief as applied the spectrometer by the patients subjective pain relief scale(visual analogue scale, VAS, 0~100%), and then to observe a continuation of pain relief following its application for managing acute and chronic pain in the 102 patients during an 8 months period beginning March, 1993. An application time of the spectrometer ranged from 15 to 30 minutes daily in each patient at or near the site of pain and trigger point when the patient wanted to be treated. The subjects consisted of 54 males and 48 females, with the age distribution between 23~40 years in 29 cases, 41~60 years in 48 cases and 61~76 years in 25 cases respectively(Table 1). The kinds of diagnosis and the main site of pain, the duration of pain before the application, and the frequency of it's application were recorded on the Table 2, 3 and 4. A distinction between acute and chronic pain was defined according to both of the pain intervals lasting within and over 3 months. The results of application of the spectrometer were noted as follows; In 51 cases of acute pain before the application, the pain intensities were rated mild in 10 cases, moderate in 15 cases and severe in 26 cases. The amounts of pain relief were noted as between 30~50% in 9 cases, 51~70% in 13 cases and 71~95% in 29 cases. The continuation of pain relief appeared between 6~24 hours in two cases, 2~5 days in 10 cases, 6~14 days in 4 cases, 15 days in one case, and completely relived of pain in 34 cases(Table 5~7). In 51 cases of chronic pain before the application, the pain intensities were rated mild in 12 cases, moderate in l8 cases and severe in 21 cases. The amounts of pain relief were noted as between 0~50% in 10 cases, 51~70% in 27 cases and 71~90% in 14 cases. The continuation of pain relief appeared to have no effect in two cases. The level of effective duration was between 6~12 hours in two cases, 2~5 days in 11 cases, 6~14 days in 14 cases, 15~60 days in 9 cases and in 13 cases the patient was completely relieved of pain(Table 5~7). There were no complications in the patients except a mild reddening and tingling sensation of skin while applying the spectrometer. Total amounts of pain relief in all of the subjects were accounted as poor and fair in 19(18.6%) cases, good in 40(39.2%) cases and excellent in 43(42.2%) cases. The clinical effectiveness of MRA $I_{TM}$ showed variable distributions from no improvements to complete relief of pain by the patient's assessment. In conclusion, we suggest that MRA $I_{TM}$ may be successful in immediate and continued pain relief but still requires several treatments for continued relief and may be gradually effective in pain relief while being applied repeatedly.

  • PDF

전자펜 입력용 투명패턴 검사장치 개발 (Development of Inspection System for Transparent Pattern of the Electromagnetic Resonance Pen)

  • 유영기
    • 한국산학기술학회논문지
    • /
    • 제21권6호
    • /
    • pp.640-645
    • /
    • 2020
  • 전자기 유도 방식의 투명 전자 패턴을 이용한 입력장치의 안정적 생산을 위해서는 생산 공정에서 미리 패턴 검사가 필요한 실정이다. 손터치용 정전용량 패턴의 검사 방법은 다양하게 제시 되어왔으나, 투명 전자기 유도 방식의 패턴 검사방법은 관련 기술 자료를 찾기 힘든 실정이다. 본 연구에서는 메탈 메쉬형 패턴으로 제작된 융합형 전자기유도 센서의 검사방법을 개발하기 위하여, 측정 센서에서 노출된 FPCB 커넥터 부분만의 측정으로 센서 내부의 안테나 임피던스를 측정하기 위한 새로운 측정알고리즘과 측정 방법을 제안하였다. 제안된 검사방법은 자체 개발된 윈도우 운영프로그램으로 제어되는 컴퓨터의 명령에 따라 미리 설정된 특정 채널 간의 루프를 형성하는 마이크로프로세서로 구성된 제어 보드, 특정 채널 간의 임피던스를 고정밀도로 측정하는 LCR 메터 그리고 측정결과를 컴퓨터로 전송하는 통신 시스템으로 구성하였다. 제안된 시스템을 설계 제작하여 자동으로 설정된 채널 간의 측정을 수행하였으며, 9개의 시편에 대하여 임피던스를 실제 측정한 결과와 제안된 시스템으로 측정한 결과, 실제 제품에 사용되는 센서의 기능 불량을 검출할 수 있는 성능을 보임을 알 수 있었다.

ESPI와 음향공진법을 이용한 Foil 재료의 동적탄성계수 측정 (Measurement of Dynamic Elastic Modulus of Foil Material by ESPI and Sonic Resonance Testing)

  • 이항서;김경석;강기수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.914-917
    • /
    • 2005
  • The paper proposes a new sonic resonance test for a dynamic elastic constant measurement which is based on time-average electronic speckle pattern interferometry(TA-ESPI)and Euler-Bernoulli equation. Previous measurement technique of dynamic elastic constant has the limitation of application for thin film or polymer material because contact to specimen affects the result. TA-ESPI has been developed as a non-contact optical measurement technique which can visualize resonance vibration mode shapes with whole-field. The maximum vibration amplitude at each vibration mode shape is a clue to find the resonance frequencies. The dynamic elastic constant of test material can be easily estimated from Euler-Bernoulli equation using the measured resonance frequencies. The TA-ESPI dynamic elastic constant measurement technique is able to give high accurate elastic modulus of materials through a simple experiment and analysis.

  • PDF

A Novel Compact Tunable Bandpass Filter Loaded Varactor Diode on the DGS

  • Kim, Gi-Rae
    • Journal of information and communication convergence engineering
    • /
    • 제8권3호
    • /
    • pp.263-266
    • /
    • 2010
  • In this paper, a novel defected ground structure (DGS) pattern with enhanced effective capacitance (varactor diode) and a hole in PCB center is presented. The increase in effective capacitance enables the new DGS pattern to achieve a lower resonance than the DGS pattern for the same etched square dimension. The hole in the center also can make resonator frequency lower with better characteristic. According to the tunable characteristic of varactor diode, the resonant frequencies can be tunable. Simulation results show that a lower resonance is achieved with active device, compared to a common DGS pattern.