• Title/Summary/Keyword: resonance component

Search Result 276, Processing Time 0.037 seconds

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

Metabolic profiling study of ketoprofen-induced toxicity using 1H NMR spectroscopy coupled with multivariate analysis

  • Jung, Jee-Youn;Hwang, Geum-Sook
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.15 no.1
    • /
    • pp.54-68
    • /
    • 2011
  • $^1H$ nuclear magnetic resonance (NMR) spectroscopy of biological samples has been proven to be an effective and nondestructive approach to probe drug toxicity within an organism. In this study, ketoprofen toxicity was investigated using $^1H$-NMR spectroscopy coupled with multivariate statistical analysis. Histopathologic test of ketoprofen-induced acute gastrointestinal damage in rats demonstrated a significant dose-dependent effect. Furthermore, principal component analysis (PCA) derived from $^1H$-NMR spectra of urinary samples showed clear separation between the vehicle-treated control and ketoprofen-treated groups. Moreover, PCA derived from endogenous metabolite concentrations through targeted profiling revealed a dose-dependent metabolic shift between the vehicle-treated control, low-dose ketoprofen-treated (10 mg/kg body weight), and high-dose ketoprofen-treated (50 mg/kg) groups coinciding with their gastric damage scores after ketoprofen administration. The resultant metabolic profiles demonstrated that the ketoprofen-induced gastric damage exhibited energy metabolism perturbations that increased urinary levels of citrate, cis-aconitate, succinate, and phosphocreatine. In addition, ketoprofen administration induced an enhancement of xenobiotic activity in fatty oxidation, which caused increase levels of N-isovalerylglycine, adipate, phenylacetylglycine, dimethylamine, betaine, hippurate, 3-indoxylsulfate, N,N-dimethylglycine, trimethyl-N-oxide, and glycine. These findings demonstrate that $^1H$-NMR-based urinary metabolic profiling can be used for noninvasive and rapid way to diagnose adverse drug effects and is suitable for explaining the possible biological pathways perturbed by nonsteroidal anti-inflammatory drug toxicity.

New Perspectives in Pediatric Nonalcoholic Fatty Liver Disease: Epidemiology, Genetics, Diagnosis, and Natural History

  • Ko, Jae Sung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.6
    • /
    • pp.501-510
    • /
    • 2019
  • Nonalcoholic fatty liver disease (NAFLD) is the most common cause of chronic liver disease in children. The global prevalence of pediatric NAFLD from general populations is 7.6%. In obese children, the prevalence is higher in Asia. NAFLD has a strong heritable component based on ethnic difference in the prevalence and clustering within families. Genetic polymorphisms of patatin-like phospholipase domain-containing protein 3 (PNPLA3), transmembrane 6 superfamily member 2, and glucokinase regulatory protein (GCKR) are associated with the risk of NAFLD in children. Variants of PNPLA3 and GCKR are more common in Asians. Alterations of the gut microbiome might contribute to the pathogenesis of NAFLD. High fructose intake increases the risk of NAFLD. Liver fibrosis is a poor prognostic factor for disease progression to cirrhosis. Magnetic resonance spectroscopy and magnetic resonance proton density fat fraction are more accurate for steatosis quantification than ultrasound. Noninvasive imaging methods to assess liver fibrosis, such as transient elastography, shear-wave elastography, and magnetic resonance elastography are useful in predicting advanced fibrosis, but they need further validation. Longitudinal follow-up studies into adulthood are needed to better understand the natural history of pediatric NAFLD.

A Study on the Redundant Vibration Analysis for the Development of Scratch Processing Technology (스크래치 가공기술 개발에 따른 잉여 진동 성분 분석에 관한 연구)

  • Jeon C.D.;Cha J.H.;Yun Sh.I.;Han S.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1660-1663
    • /
    • 2005
  • Unwanted vibrations are inevitably induced in other directions when pure unidirectional vibration motion is desired for the vertical scratching mechanism. Pure vertical vibration motion of the scratching machine can be obtained by driving identical two motors with symmetrically positioned eccentric unbalance masses. The desired optimal condition for driving pure vertical vibration for the scratching machine is assumed to be the resonance condition in that direction. Imposing the flexibility of the scratching machine in the horizontal direction, we can find out the amount of horizontal vibration component while maintaining the resonance in vertical direction. The desired stiffness in horizontal direction which produces the minimum vibration in horizontal direction are defined which can be used as a guide line to design the supporting structure of the scratching machine.

  • PDF

Spinal Subdural Hematoma Associated with Intracranial Subdural Hematoma

  • Kim, Myoung Soo;Sim, Sook Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.397-400
    • /
    • 2015
  • The simultaneous occurrence of an intracranial and a spinal subdural hematoma (SDH) is rare. We describe a case of cranial SDH with a simultaneous spinal SDH. An 82-year-old woman visited the emergency room because of drowsiness and not being able to walk 6 weeks after falling down. A neurological examination showed a drowsy mentality. Brain computed tomography showed bilateral chronic SDH with an acute component. The patient underwent an emergency burr-hole trephination and hematoma removal. She exhibited good recovery after the operation. On the fourth postoperative day, she complained of low-back pain radiating to both lower limbs, and subjective weakness of the lower limbs. Spine magnetic resonance imaging revealed a thoracolumbosacral SDH. A follow-up spinal magnetic resonance imaging study that was performed 16 days later showed a significant decrease in the size of the spinal SDH. We discuss the pathogenesis of this simultaneous occurrence of spinal and cranial SDH.

A Study on the Optimized Pump Selection of the Cooling System for the PEFP DTL Accelerator (PEFP DTL 냉각시스템의 펌프 선정 최적화에 관한 연구)

  • Park, Jun;Kim, Kyung-Ryul;Kim, Hyung-Gyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1277-1282
    • /
    • 2009
  • The main objective of this prototype is to control resonance frequency of DTL system through the temperature control of cooling water. It is to resonant frequency of the drift tube cavities to 350 MHz. This paper describes the design of a prototype cooling water skid required for the temperature control of the DTL cavities, focusing in the modeling and simulation of the cooling system, the sizing of water pumping skid component.

  • PDF

Design of the Shimming Coils for MRI Magnet (MRI 마그네트용 보정코일 설계)

  • Bae, Jun-Han;Go, Rak-Gil;Jin, Hong-Beom;Sim, Gi-Deok;Gwon, Yeong-Gil;Ryu, Gang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.587-591
    • /
    • 2001
  • This paper describes the general and efficient design method of an axial and a radial shim coils to correct field impurities of various harmonic orders in the imaging volume of Magnetic Resonance Imaging magnet. Shim coils are optimized by BCLSF subroutine of IMSL, which is the well-known commercial package for optimization, aiming at maximizing the magnitude of the desired field component as well as minimizing other field components. In order to evaluate their effect, the developed method was applied to the MRI magnet constructed in KERI.

  • PDF

APPLICATION OF ALANINE/ESR SPECTRUM SHAPE CHANGE IN GAMMA DOSIMETRY

  • Choi, Hoon;Kim, Jeong-In;Lee, Byung-Ill;Lim, Young-Ki
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.313-318
    • /
    • 2010
  • Alnine pellets were installed in a nuclear power plant for one or two operation cycles and measured by electron spin resonance (ESR) spectrometers for dosimetry. Dose and "x/y ratio", i.e., satellite peak over main center peak ratio, were measured for the returned alanine dosimeters from the nuclear power plant and compared to the values of reference alanine dosimeters exposed only to gamma rays. The variation of the x/y ratio change depended on the population of radicals from each radiation component with different LET. The gamma dose in a mixed radiation field was estimated by an additive gamma ray irradiation experiment and the measured dose rate at specified locations in the containment building.

MRI findings of a huge cystadenocarcinoma of the palate (구개에 발생한 거대 낭샘암종의 MRI 소견)

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.191-196
    • /
    • 2010
  • Cystadenocarcinoma of the salivary glands is a very rare, slow growing, and low-grade malignant neoplasm. It is characterized by predominantly cystic growth with or without the intraluminal papillary component. However, it lacks of any additional specific histopathologic features that characterize other types of salivary carcinomas showing cystic growth. Therefore, definite diagnosis of the cystadenocarcinoma is difficult and it is often misdiagnosed. It is conceptually the malignant counterpart of the benign cystadenoma. We present a cystadenocarcinoma on the palate of a 49-year-old man with special emphasis on magnetic resonance imaging.

High Frequency Inverter for Induction Heating with Multi-Resonant Zero Current Switching (다중공진 영전류 스위칭을 이용한 고주파 유도가열용 인버터)

  • Ra, B.H.;Suh, K.Y.;Lee, H.W.;Kim, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.38-40
    • /
    • 2002
  • In the case of conventional high frequency inverter, with damage of switch by surge voltage when switch gets into compulsion extinction by load accident and so on because reactor is connected by series to switch, or there was problem of conduction loss by reactor's resistivity component, Also, it has controversial point of that can not ignore conduction loss of switch in complete work kind action of soft switching. In this paper, as high frequency induction heating power supply, we propose half bridge type multi resonance soft switching high frequency inverter topology that can realize high amplitude operation of load current with controlling switch current by multiplex resonance, mitigating surge voltage when switch gets into compulsion extinction and to be complete operation of zero current switching by opposit parallel connected reactor to inverter switch. and do circuit analysis for choice of most suitable circuit parameter of circuit

  • PDF