• Title/Summary/Keyword: resonance characteristic

Search Result 551, Processing Time 0.025 seconds

A Study on Vibration Characteristic of Stiffened Plates with Fluid Coupling Effect inside a Tank (탱크 내부 유체 연성 효과에 의한 보강판의 진동 특성 연구)

  • Jeong, Woo-In;Kwon, Jong-Hyun;Kim, Mun-Su
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2015.09a
    • /
    • pp.56-62
    • /
    • 2015
  • In ship structure, many parts are in contact with inner or outer fluid as stern, ballast and oil tanks. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance with exciting force of engine and propeller. Vibration characteristics of these tanks in contact with fluid are significantly affected by fluid coupling effect. Therefore it is important to exactly predict vibration characteristics of tank structure. In order to estimate the vibration characteristics, the fluid-structure interaction(FSI) problem should be solved precisely. But it is difficult to estimate exactly the magnitude of the fluid coupling effect because it has some problems such as a fluid-structure interaction, influence by the free surface, vibration modes of structural panels and depth of water. In this paper, with fluid coupling effect, the effect of structural constraint between panels on the vibration characteristics are investigated numerically and discussed.

  • PDF

Nelumbo nucifera extracts mediated synthesis of silver nanoparticles for the potential applications in medicine and environmental remediation

  • Supraja, N.;Avinash, B.;Prasad, T.N.V.K.V.
    • Advances in nano research
    • /
    • v.5 no.4
    • /
    • pp.373-392
    • /
    • 2017
  • Silver nanoparticles (AgNPs) were successfully synthesized through a simple green route using the Nelumbo nucifera leaf, stem and flower extracts. These nanoparticles showed characteristic UV-Vis absorption peaks between 410-450 nm which arises due to the plasmon resonance of silver nanoparticles. The Fourier transform infrared spectroscopy (FT-IR) confirmed the presence of amides and which acted as the stabilizing agent. X-ray diffraction spectrum of the nanoparticles confirmed the Face centered cubic (FCC) structure of the formed AgNPs. Dynamic light scattering technique was used to measure hydrodynamic diameter (68.6 nm to 88.1 nm) and zeta potential (-55.4 mV, -57.9 mV and 98.9 mV) of prepared AgNPs. The scanning electron micrographs of dislodged nanoparticles in aqueous solution showed the production of reasonably monodispersed silver nanoparticles (1-100 nm). The antimicrobial activity of prepared AgNPs was evaluated against fungi, Gram-positive and Gram-negative bacteria using disc diffusion method. Anti-corrosion studies were carried out using coupon method (mild steel and iron) and dye degradation studies were carried out by assessing photo-catalytic activity of Nelumbo nucifera extracts mediated AgNPs.

Characteristic Analysis of Induction Phenomena in the Nearby Mesh Structure Conductive Part of Large Capacity Wireless Power Transmission System (대용량 무선전력전송 환경 인근 메쉬구조 도전부 유도현상 특성 분석)

  • Chae, Dong-Ju;Yi, Geon-Ho;Lim, Hyun-Sung;Cho, Sung-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.207-214
    • /
    • 2019
  • A large-capacity wireless power system is a technology that transmits electric power of kW or more in a noncontact type. Electric cars, electric buses, and electric railways. In order to increase the power transmission efficiency, a resonance method using a frequency of kHz is applied and the efficiency is 80 ~ 90%. In this case, the loss is 10 ~ 20% other than efficiency, and corresponds to several hundreds of W to several kW in kW class wireless power transmission. 35 kW wireless feed system environment, and induced current in the nearby conductive part was measured. As a result of analysis, it was confirmed that induction phenomenon is higher as the loop configuration of the conductive part per area is dense. The increase of the induced current in the mesh loop is characterized by the density of the nearby conductive part having a permeability per unit area. The concentration of the magnetic field by the permeability is increased and the induction phenomenon causing the induction current is increased. It was confirmed that induction phenomenon increases by about 2.7 times when 9 times dense structure is formed.

Intramuscular hemangioma in the zygomaticus minor muscle: a case report and literature review

  • Wee, Sung Jae;Park, Myong Chul;Chung, Chan Min;Tak, Seung Wan
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.2
    • /
    • pp.115-118
    • /
    • 2021
  • Intramuscular hemangioma is a rare vascular benign proliferation that can occur within any muscle, particularly in the trunk and extremities. In the head and neck region, the masseter muscle is most commonly involved, followed by the periorbital and sternocleidomastoid muscles. Diagnosing intramuscular hemangioma is challenging because there are no characteristic symptoms; instead, magnetic resonance imaging is the best imaging modality to diagnose these lesions. Complete surgical resection is the treatment of choice, although the local recurrence rate is high. Herein, we report a rare case of intramuscular hemangioma located in the zygomaticus minor muscle, which is related to smiling and usually runs along the orbicularis oculi muscle. Distinguishing or separating these two muscles is challenging. However, based on the muscle vector of the midface and radiological findings, the two muscles were successfully separated. The zygomaticus minor was cut very slightly to approach to the lesion and the muscle fibers were split to excise it. A follow-up examination revealed no nerve damage or muscle dysfunction at 4 weeks postoperatively. This rare case may serve as a reference for managing intramuscular hemangioma in the head and neck region.

Effect of Traditional Korean Medicine Treatments on the Discoid Meniscus of Knee Joint: Two Clinical Cases

  • Yoon-Jae Won;Sun-Woo Kang;Myeong-Yeol Yang;Jae-Joon Ha;Ji-Sun Kim;Hong-Wook Choi;Gyu-Bin Lee
    • Journal of Acupuncture Research
    • /
    • v.40 no.1
    • /
    • pp.90-96
    • /
    • 2023
  • The discoid meniscus is an innate modified form of the meniscus, characterized by middle hypertrophy and a larger than the regular diameter, leading to an absence of the characteristic "C" arrangement. Previously, no study has reported the traditional Korean medicine treatment of knee pain mainly due to discoid meniscus. Here, we report two cases of a discoid meniscus of the knee as the cause of knee pain. Patients were diagnosed with magnetic resonance imaging for discoid meniscus and received traditional Korean medicine treatments, including pharmacopuncture, acupuncture, herbal medicine, and chuna. The pain was alleviated when assessed by patient-reported pain scale scores, and the general knee condition was improved. Thus, traditional Korean medicine treatments could be effective for patients who had discoid meniscus of the knee joint in this case report.

Importance of 3-dimensional imaging in the early diagnosis of chondroblastic osteosarcoma

  • Laura Althea Cuschieri;Rebecca Schembri-Higgans;Nicholas Bezzina;Alexandra Betts;Arthur Rodriguez Gonzalez Cortes
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.247-256
    • /
    • 2023
  • The aim of this report is to present a case of chondroblastic osteosarcoma located in the right maxillary premolar region of a 17-year-old female patient. The initial clinical presentation and 2-dimensional (2D) radiographic methods proved inadequate for a definitive diagnosis. However, a cone-beam computed tomography scan revealed a hyperdense, heterogeneous lesion in the right maxillary premolar region, exhibiting a characteristic "sun-ray" appearance. To assess soft tissue involvement, a medical computed tomography scan was subsequently conducted. A positron emission tomography scan detected no metastasis or indications of secondary tumors. T1- and T2-weighted magnetic resonance imaging showed signal heterogeneity within the lesion, including areas of low signal intensity at the periphery. Histological examination conducted after an incisional biopsy confirmed the diagnosis of highgrade chondroblastic osteosarcoma. The patient was then referred to an oncology department for chemotherapy before surgery. In conclusion, these findings suggest that early diagnosis using 3-dimensional imaging can detect chondroblastic osteosarcoma in its early stages, such as before metastasis occurs, thereby improving the patient's prognosis.

Preparation of Ag, Pd, and Pt50-Ru50 colloids prepared by γ-irradiation and electron beam and electrochemical immobilization on gold surface

  • Kim, Kyung-Hee;Seo, Kang-Deuk;Oh, Seong-Dae;Choi, Seong-Ho;Oh, Sang-Hyub;Woo, Jin-Chun;Gopalan, A.;Lee, Kwang-Pill
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.333-341
    • /
    • 2006
  • PVP-protected Ag, Pd and $Pt_{50}-Ru_{50}$ colloids were prepared independently by using ${\gamma}$-irradiation and electron beam (EB) at ambient temperature. UV-visible spectra of these colloids show the characteristic bands of surface resonance and give evidence for the formation of nanoparticles. Transmission electron microscopy (TEM) experiments were used to know the morphology of nanoparticles prepared by ${\gamma}$-irradiation and EB. The size of Ag, Pd, and $Pt_{50}-Ru_{50}$ nanoparticles prepared by ${\gamma}$-irradiation was ca. 13, 2-3, 15 nm, respectively. While, the size of Ag, Pd, and $Pt_{50}-Ru_{50}$ nanoparticles prepared by EB was ca. 10, 6, and 1-3 nm, respectively. Cyclic voltamograms (CV) were recorded for the Au electrodes immobilized with these nanoparticles. CVs indicated the modifications in the surface as a result of immobilization.

Discretized solenoid design of a 1.5 T and a 3.0 T REBCO whole-body MRI magnets with cost comparison according to magnetic flux

  • Wonju Jung;Geonyoung Kim;Kibum Choi;Hyunsoo Park;Seungyong Hahn
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.75-80
    • /
    • 2023
  • Rare earth barium copper oxide (REBCO) materials have shown the possibility of high-temperature superconductor (HTS) magnetic resonance imaging (MRI) magnets due to their elevated transition temperature. While numerous MRI magnet designs have emerged, there is a growing emphasis on estimating the cost before manufacturing. In this paper, we propose two designs of REBCO whole-body MRI magnets: (1) 1.5 T and (2) 3.0 T, the standard center field choices for hospital use, and compare their costs based on conductor usage. The basis topology of the design method is based on discretized solenoids to enhance field homogeneity. Magnetic stress calculation is done to further prove the mechanical feasibility of their construction. Multi-width winding technique and outer notch structure are used to improve critical current characteristic. We apply consistent constraints for current margins, sizes, and field homogeneities to ensure an equal cost comparison. A graph is plotted to show the cost increase with magnetic flux growth. Additionally, we compare our designs to two additional MRI magnet designs from other publications with respect to the cost and magnetic flux, and present the linear relationship between them.

Analysis of Vibration in Cello Bridge (첼로 브릿지의 진동 분석)

  • Choi Gi-Sang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.5
    • /
    • pp.197-206
    • /
    • 2006
  • Vibration of string is transmitted to the front plate through bridge to cause resonance of the instrument body in viol family string instruments. Therefore. the properties. geometrical shape. and positioning of the bridge are expected to have some effect on the sound color. In this study the strain and the stress in the bridge. and the force exerted on the top plate by the bridge as the string vibrates the bridge in cello are calculated through simulation based on the theory of elasticity. The modes of vibration and the characteristic frequencies are also found. Furthermore. the effect of geometric shape of bridge on sound color is studied in terms of frequency response. The results of this study show that the vibration characteristics of bridge is quite complex and the properties and the geometrical shape of bridge have significant effect on sound color, and therefore. the sound color of a cello can be controlled by changing the geometrical shape of bridge.

Langerhans Cell Histiocytosis in the Skull: Comparison of MR Image and Other Images (두개골의 랑게르한스 세포 조직구증: 자기공명영상과 다른 영상과의 비교)

  • Lim, Soo-Jin;Lim, Myung-Kwan;Park, Sun-Won;Kim, Jung-Eun;Kim, Ji-Hye;Kim, Deok-Hwan;Lee, Seok-Lyong;Suh, Chang-Hae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.74-80
    • /
    • 2009
  • Purpose : To evaluate the characteristic MR imaging findings of Langerhans cell histiocytosis (LCH) in the skull and to compare them with those of plain radiography and computed tomography. Materials and Methods : A total of 10 lesions in 9 patients (Age range; 5-42 years, Mean age; 18, all women) with Langerhans cell histiocytosis in the skull were included in our study. Nine lesions in nine patients were histologically confirmed by surgery or fine needle aspiration biopsy. All patients performed with MRI, and plain radiography and CT scan were done in 7 patients (8 lesions). Two experienced neuroradiologists reviewed the radiological examinations independently with attention to location, size, shape and nature of the lesions in the skull and compared the extent and extension of the lesions to adjacent structures. Results : The lesions were distributed in all of the skulls without predilection site. On MRI, the masses were shown as well-enhancing soft tissue masses (10/10) mainly in diploic spaces (8/10) with extension to scalp (9/10) and dura mater (7/10). Dural enhancement (7/10) and thickening (4/10) were seen. The largest diameter of the soft tissue masses ranged 1.1 cm to 6.8 cm, shaped as round (5/10) or oval (5/10). On CT scans, the lesions were presented as soft tissue masses involving diploic space (6/8) and scalp extension (7/8) were also well visualized. Although bony erosion or destruction was more clearly seen on CT rather than those of MRI, enhancement of soft tissue masses and dura were not well visualized on CT. In contrast, all of the lesions in LCH were seen as punched out (4/8), beveled-edge appearance (4/8) osteolytic masses in plain radiography, but scalp and dural extension could not be seen. Conclusion : Characteristic MR findings in patients with LCH are soft tissue mass in diploic space with extension to dura and scalp, and MRI would be better imaging modality than plain radiography or CT.

  • PDF