• Title/Summary/Keyword: resonance capture

Search Result 43, Processing Time 0.027 seconds

Detection of Avian Influenza-DNA Hybridization Using Wavelength-scanning Surface Plasmon Resonance Biosensor

  • Kim, Shin-Ae;Kim, Sung-June;Lee, Sang-Hun;Park, Tai-Hyun;Byun, Kyung-Min;Kim, Sung-Guk;Shuler, Michael L.
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.392-397
    • /
    • 2009
  • We designed a wavelength interrogation-based surface plasmon resonance (SPR) biosensor to detect avian influenza DNA (AI-DNA). Hybridization reactions between target AI-DNA probes and capture probes immobilized on a gold surface were monitored quantitatively by measuring the resonance wavelength in the visible waveband. The experimental results were consistent with numerical calculations. Although the SPR detection technique does not require the DNA to be labeled, we also evaluated fluorescently-labeled targets to verify the hybridization behavior of the AI-DNA. Changes in resonance were found to be linearly proportional to the amount of bound analyte. A wavelength interrogation-type SPR biosensor can be used for rapid measurement and high-throughput detection of highly pathogenic AI viruses.

Investigation of Dose Distribution in Mixed Neutron-Gamma Field of Boron Neutron Capture Therapy using N-Isopropylacrylamide Gel

  • Bavarnegin, Elham;Khalafi, Hossein;Sadremomtaz, Alireza;Kasesaz, Yaser;Khajeali, Azim
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.189-195
    • /
    • 2017
  • Gel dosimeters have unique advantages in comparison with other dosimeters. Until now, these gels have been used in different radiotherapy techniques as a reliable dosimetric tool. Because dose distribution measurement is an important factor for appropriate treatment planning in different radiotherapy techniques, in this study, we evaluated the ability of the N-isopropylacrylamide (NIPAM) polymer gel to record the dose distribution resulting from the mixed neutron-gamma field of boron neutron capture therapy (BNCT). In this regard, a head phantom containing NIPAM gel was irradiated using the Tehran Research Reactor BNCT beam line, and then by a magnetic resonance scanner. Eventually, the $R_2$ maps were obtained in different slices of the phantom by analyzing T2-weighted images. The results show that NIPAM gel has a suitable potential for recording three-dimensional dose distribution in mixed neutron-gamma field dosimetry.

Evaluation of Two Types of Biosensors for Immunoassay of Botulinum Toxin

  • Choi, Ki-Bong;Seo, Won-Jun;Cha, Seung-Hee;Choi, Jung-Do
    • BMB Reports
    • /
    • v.31 no.1
    • /
    • pp.101-105
    • /
    • 1998
  • Immunoassay of botulinum toxin (BTX) B type was investigated using two typed of biosensors: light addressable potentiometric sensor (LAPS) and surface plasmon resonance (SPR) sensor. Urease-tagged and immuno-filtration capture method have been used for LAPS. Tag-free and direct binding real-time detection method have been used for SPR sensor. The detection limit of sandwich assay format with LAPS was 10 ng/ml, which was the lowest among methods tested. SPR has the advantage of being more convenient because tag-free direct binding assay can be used and reaction time was reduced, regardless of low sensitivity. This result shows that sandwich assay format with LAPS can be used as an alternative method of BTX mouse bioassay which is known as the most sensitive method for the detection of BTX.

  • PDF

Wave power extraction by multiple wave energy converters arrayed in a water channel resonator

  • Kim, Jeongrok;Cho, Il-Hyoung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.178-186
    • /
    • 2021
  • The wave power extraction by multiple Wave Energy Converters (WECs) deployed in a Y-shaped Water Channel Resonator (WCR) has been investigated. A WCR consists of a long water channel, and a V-shaped wave guider installed at the entrance of a water channel. If the period of the incident waves coincides with the natural periods of the fluid in a WCR, resonance occurs, as a result, the internal fluid in a WCR is greatly amplified. To estimate the wave power by multiple WECs placed at the antinodal points in a WCR, the heave motion response, time-averaged power, and capture width ratio were calculated for several design parameters. Also, the systematic model tests were conducted in a 2D wave tank. The numerical results are in good agreement with the experimental data. It was verified that a WCR helps the WECs to produce electricity more effectively by amplifying the wave energy in a WCR.

Successful treatment of gastrocnemius muscle rupture in a long-tailed goral rescued from a live trap: a case report

  • Ahn, Sangjin;Choi, Sooyoung;Kim, Jong-Taek
    • Journal of Veterinary Science
    • /
    • v.23 no.3
    • /
    • pp.45.1-45.5
    • /
    • 2022
  • We describe a case of gastrocnemius muscle rupture in a goral that got caught in a live trap set up to capture wild boars. We established a diagnostic method based on clinical signs and imaging examination findings, including magnetic resonance imaging for gastrocnemius muscle rupture with symptoms such as hindlimb lameness and plantigrade posture of unknown cause in wild animals. Although this condition is rare, this report will help veterinarians diagnose several diseases of the musculoskeletal and nervous systems in wild animals. This is the first report of successful diagnosis and treatment of gastrocnemius muscle rupture in gorals in Korea.

Analysis and Design of a Wave Energy Conversion Buoy

  • Oh, Jin-Seok;Bae, Soo-Young;Jung, Sung-Young
    • Journal of Navigation and Port Research
    • /
    • v.32 no.9
    • /
    • pp.705-709
    • /
    • 2008
  • In the sea various methods have been conducted to capture wave energy which include the use of pendulums, pneumatic devices, etc. Floating devices, such as a cavity resonance device take advantages of both the water motion and the wave induced motions of the floating body itself. The wave energy converter is known commercially as the WAGB(Wave Activated Generator Buoy) and is used in some commercially available buoys to power navigation aids such as lights and horns. This wave energy converter consists of a circular flotation body which contains a vertical water column that has free communication with the sea. A theoretical analysis of this power generated by a pneumatic type wave energy converter is performed and the results obtained from the analysis are used for a real wave energy converter buoy. This paper is shown to have an optimum value for which maximum power is obtained at a given resonant wave period Also, the length of the internal water column corresponds to that of the water mass in the water column. If designed properly, wave energy converter can take advantage not only of the cavity resonance, but also qf the heaving motion of the buoy. Finally, simulation is performed with a LabVIEW program and the simulation results are applied to a wave energy simulator for modifying design data for a wave energy converter.

Development of the Real-time Concentration Measurement Method for Evaporating Binary Mixture Droplet using Surface Plasmon Resonance Imaging (표면플라즈몬공명 가시화 장치를 이용한 증발하는 이종혼합물 액적의 실시간 농도 가시화 기법 개발)

  • Jeong, Chan Ho;Lee, Hyung Ju;Choi, Chang Kyoung;Lee, Hyoungsoon;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.26 no.4
    • /
    • pp.212-218
    • /
    • 2021
  • The present study aims to develop the Surface Plasmon Resonance (SPR) imaging system facilitating the real-time measurement of the concentration of evaporating binary mixture droplet (BMD). We introduce the theoretical background of the SPR imaging technique and its methodology for concentration measurement. The SPR imaging system established in the present study consists of a LED light source, a polarizer, a lens, and a band pass filter for the collimated light of a 589 nm wavelength, and a CCD camera. Based on the Fresnel multiple-layer reflection theory, SPR imaging can capture the change of refractive index of evaporating BMD. For example, the present study exhibits the visualization process of ethylene glycol (EG)-water (W) BMD and measures real-time concentration change. Since the water component is more volatile than the ethylene glycol component, the refractive index of EG-W BMD varies with its mixture composition during BMD evaporation. We successfully measured the ethylene glycol concentration within the evaporating BMD by using SPR imaging.

Social Media Performance: From the Perspective of Social Media Apathetic Behavior

  • Inwon Kang;Sungjoon Yoo
    • Journal of Korea Trade
    • /
    • v.26 no.3
    • /
    • pp.1-22
    • /
    • 2022
  • Purpose - Social media platforms have presented individuals with an opportunity to create and maintain their social relationship through the use of social media services. However, such social relationship has a negative influence on users' interest in social media. Design/methodology - Using structural equation modeling, this study seeks to examines the effects of different social media conflicts (individual and social conflicts) on users' psychological internal state, especially user apathetic behavior Findings - The findings confirm that, among social media conflicts, social-related conflict, especially social interaction overload has a negative effect on cognitive resonance, while individual conflict has the highest effect on cognitive dissonance. Also, cognitive dissonance has a much greater effect than cognitive resonance on user resistance, this means that users' negative perception of social media has a greater influence on their resistance. Lastly, user's resistance was found to have a positive influence on user's apathetic behavior. Originality/value - In other to capture social media Apathetic behavior, this study focus on social media conflict perspective, which includes social-related conflict and individual conflict, which are found to influence users' internal states towards social media and further induce social media behavior. This study is unique because it is among the first to explore social media apathetic behavior by focusing on the influence of both external social media conflict and internal state. Also, this study proposed that social related conflict has a higher negative influence on WeChat user than individual related conflict.

Shape Oscillation and Mode Characteristic of Droplet on Vibrating Flat Surface (진동 평판 위 액적의 형상 진동 변화 및 모드 특성)

  • Shin, Young-Sub;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.489-494
    • /
    • 2013
  • This study aims to understand the mode characteristics of a droplet under a periodic forced vibration. To predict the resonance frequency of a droplet, theoretical and experimental approaches were employed. A high-speed camera was used to capture the various deformation characteristics of a droplet-mode shape, detachment, separated secondary droplet, and skewed deformation. The comparison between the theoretical and the experimental approaches shows a ~10% discrepancy in the prediction of the resonance frequency, which appears to be caused by the effect of contact line friction, nonlinear wall adhesion, and experimental uncertainty. Owing to contact-line pinning and smaller amplitude, the droplet shape becomes symmetric and the size of each lobe at the resonance frequency exceeds that at the neighbor, which is out of resonance.

An Analysis of U-233 Resonance Absorption

  • Yoo, Kun-Joong;Mann Cho;Kim, Chang H.;Chi, Chang-Yul
    • Nuclear Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.267-275
    • /
    • 1975
  • The low-lying resolved resonance structure of U-233 is investigated in terms of the Adler-Adler multilevel formalism. The resonance capture and fission cross sections of U-233 below 60 eV are calculated using Adlers' effective resonance parameters. The infinite dilution resonance integrals of U-233 are computed with the use of the Alders' parameters adjusted to fit the cross section data. It is found that the agreement of calculations with experiments is generally good over most of the energy region covered. A transformation of the Adlers' multilevel parameters into an equivalent set of the single level pseudoparameters is made for the use of the existing computer codes which are useful in the reactor calculations but do not have capability to use the multilevel parameters. The results of this transformation are presented in the form of a table.

  • PDF