• 제목/요약/키워드: resolved resonance

검색결과 128건 처리시간 0.031초

CONTRAST-ENHANCED MR ANGIOGRAPHY : PRINCIPLES, IMPLEMENTATION, AND APPLICATIONS

  • Riederer, Stephen J.
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.117-122
    • /
    • 2002
  • Contrast-enhanced MR angiography has become a widely used method useful for clinical diagnosis. Early studies identified a number of technical issues, and many of these have been addressed with various MRI physics innovations over the last several years. The quality of the results is high enough that CE MRA is replacing conventional x-ray angiography methods at many institutions. Ongoing research is expected to provide further improvements in performance, most notably in additional reductions in examination time, in time-resolved 3D imaging, and in improved imaging of the peripheral vasculature with extended fields of view.

  • PDF

고속 PIV계측에 의한 실린더 근접후류 공진 유동 가시화 (Visualization of Vortex Lock-on to Oscillatory Incident Flow in the Cylinder Wake Using Time-Resolved PIV)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1353-1361
    • /
    • 2001
  • Vortex lock-on or resonance behind a circular cylinder is visualized using a time-resolved PW when a single frequency oscillation is superimposed on the mean incident velocity. For vector processing, a cross-correlation algorithm in conjunction with a recursive correlation and interrogation window shifting techniques is used. Measurements are made of the Karmas and streamwise vertices in the wake-transition regime at Reynolds lumber 360. When lock-on occurs, the vortex shedding frequency is found to be half the oscillation frequency as expected from previous experiments. At the lock-on state, the Karman vortices are observed to be more disordered by the increased strength and spanwise wavelength of the streamwiee vortices, which lead? to a strong three-dimensional motion.

  • PDF

폐암의 생체 수소자기공명분광법의 실행가능성 (Feasibility of $In$ $vivo$ Proton Magnetic Resonance Spectroscopy for Lung Cancer)

  • 윤순호;박창민;이창현;송인찬;이현주;구진모
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.40-46
    • /
    • 2012
  • 목적: 폐암의 생체 수소자기공명분광법의 실행가능성을 탐색하고자 하였다. 대상과 방법: 이 전향적 연구는 해당병원의 임상시험심사위원회로 승인을 받았고 모든 환자로부터 사전동의를 받았다. 병리적으로 폐암으로 확인된 (평균 직경, 56.8 mm; 범위, 44-77 mm) 10명의 환자들에서 (남자 7명, 여자 3명; 평균나이, 64.4세) 단일 복셀 수소자기공명분광기법으로 호흡 유발 PRESS (point-resolved spectroscopic sequence)를 사용하여 1.5 T 수소자기공명 분광법을 시행하였다. 스펙트럼 습득의 기술적 성공률을 평가하고 실패한 증례들의 이유를 고찰하였다. 결과: 10개의 폐암 중 8개 폐암에서 분석 가능한 수소자기공명 분광 스펙트럼을 획득했다 (기술적 성공률, 80%). 두 개의 수소자기공명 분광 데이터는 심각한 기준치 왜곡으로 분석할 수 없었다. 대표적인 대사물질로 choline과 lipid들이 관찰되었다. 결론: 비록 제한적 수의 환자에서의 결과이지만 폐암에서 얻어진 생체 수소 자기공명 분광 스펙트럼이 분석가능하고 높은 성공률로 획득하였기 때문에 폐암 환자에서 호흡 유발 PRESS 방법을 사용한 생체 수소자기공명분광법이 실행가능하다고 판단된다.

Product-Resolved Photodissociations of Iodotoluene Radical Cations

  • Shin, Seung-Koo;Kim, Byung-Joo;Jarek, Russell L.;Han, Seung-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권2호
    • /
    • pp.267-270
    • /
    • 2002
  • Photodissociations of o-, m-, and p-iodotoluene radical cations were investigated by using Fourier-transform ion cyclotron resonance (FT-ICR) spectrometry. Iodotoluene radical cations were prepared in an ICR cell by a photoionization charge-transfer method. The time-resolved one-photon dissociation spectra were obtained at 532 nm and the identities of $C_7H_7^+$ products were determined by examining their bimolecular reactivities toward toluene-$d_8$. The two-photon dissociation spectra were also recorded in the wavelength range 615-670 nm. The laser power dependence, the temporal variation, and the identities of $C_7H_7^+$ were examined at 640 nm. The mechanism of unimolecular dissociation of iodotoluene radical cations is elucidated: the lowest barrier rearrangement channel leads exclusively to the formation of the benzyl cation, whereas the direct C-I cleavage channel yields the tolyl cations that rearrange to both benzyl and tropylium cations with dissimilar branching ratios among o-, m-, and p-isomers. With a two-photon energy of 3.87 eV at 640 nm, the direct C-I cleavage channel results in the product branching ratio, [tropylium cation]/[benzyl cation], in descending order, 0.16 for meta >0.09 for ortho >0.05 for para.

Cervical Radiculopathy Caused by Vertebral Artery Loop Formation : A Case Report and Review of the Literature

  • Kim, Hoon-Soo;Lee, June-Ho;Cheh, Gene;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권5호
    • /
    • pp.465-468
    • /
    • 2010
  • Vertebral artery loop formation causing encroachment on cervical neural foramen and canal is a rare cause of cervical radiculopathy. We report a case of 61-year-old woman with vertebral artery loop formation who presented with right shoulder pain radiating to her arm for 2 years. Plain radiograph and computed tomography scan revealed widening of the right intervertebral foramen at the C5-6 level. Magnetic resonance imaging and angiogram confirmed the vertebral artery loop formation compressing the right C6 nerve root. We had considered microdecompressive surgery, but the patient's symptoms resolved after conservative management. Clinician should keep in mind that vertebral artery loop formation is one of important causes of cervical radiculopathy. Vertebral artery should be visualized using magnetic resonance angiography in suspected case.

휠로더 엔진 밸브 커버 볼트의 파손 원인 규명 및 개선 (A study on the fatigue fracture of engine valve cover bolt for a wheel loader)

  • 이군희;주원호;김동해;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1218-1222
    • /
    • 2006
  • The bolts fixing the valve cover to the engine were often reported to be failed in a wheel loader model. Recently this failures were continually repeated in the specified equipment. In order to identify the fatigue fractures of the bolts, various vibration tests were carried out. From these tests, it was found out that the failure was due to the resonance between the excitation force of engine and the transverse mode of engine valve cover. So, the several modifications for the bolts were considered to avoid the resonance. Finally, the bolt failure problem was clearly resolved.

  • PDF

자기공명유속계를 이용한 난류 유동장 가시화 (Validation of Magnetic Resonance Velocimetry by Turbulent Pipe Flow)

  • 이지수;송시몬;조지현
    • 한국가시화정보학회지
    • /
    • 제12권1호
    • /
    • pp.35-42
    • /
    • 2014
  • Magnetic resonance velocimetry (MRV) is a versatile flow visualization technique using magnetic resonance imaging machine developed for the medical purpose. Recently, MRV is often utilized to analyze engineering flows due to its superior features of MRV such as capabilities of measuring flows with complicated, opaque flow geometry unlike optical techniques, 3-dimensional volumetric velocity vectors within a few hours, and etc. The purpose of this study was to validate the MRV data and evaluate the accuracy of the mean velocity profiles that we acquired for a turbulent flow in a circular pipe using a MR machine installed in Korea Basic Science Institute, Ochang, Korea. In addition, we briefly describe a procedure of parameter optimization for the operation of MRV. The results indicate that the MRV measurements provided well resolved mean velocity fields with a quite reasonable accuracy according to the inner and outer layer scaling laws of the turbulent pipe flows.

java Based Magnetic Resonance User Interface의 Advanced Method for Accurate, Robust, and Efficient Spectral Fitting 분석방법의 관찰자 변동 요소 (Observer Variation Factor on Advanced Method for Accurate, Robust, and Efficient Spectral Fitting of java Based Magnetic Resonance User Interface for MRS data analysis)

  • 이석준;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.143-148
    • /
    • 2016
  • 본 연구에서는 MRS 정량적 분석 중 jMRUI AMARES방법의 관찰자의 의존적 원인 요소를 숙련자와 비숙련자의 측정을 통하여 파악하고 하였다. 실험용 10주령 수컷 쥐의 간 부분을 3T MRI 장치를 활용하여 point resolved spectroscopy 펄스시퀀스를 이용하여 자기공명분광 데이터를 획득하였다. 획득된 데이터는 기준 값으로 사용하기 위해서 LCModel software 이용하여 1.3 ppm의 메틸렌 양성자와 4.7 ppm의 물 분자 양성자의 정량 비를 계산하였다. 7명의 비숙련 관찰자는 jMRUI AMARES 방법으로 총 지질을 1, 2주 간격으로 측정한 후 측정된 값을 SPSS를 이용하여 interclass correlation coefficient를 시행하였다. 관찰자 사이 간 측정치의 일관성의 신뢰도 분석을 표현한 크논바 알파 계수는 0.1 미만으로 나타났다. 1주차 데이터 값과 2주차 데이터 값의 평균값은 $0.096{\pm}0.038$로 LCModel의 분석 값보다 0.048로 50% 높게 관찰되었다. jMRUI AMARES분석 방법이 LCModel과 동일한 결과를 얻기 위해서는 정확한 대사물질의 개요를 숙지하고 획득된 그래프의 형태를 잘 파악하여 잔존 대사물질를 최소화 하여야 한다.