• 제목/요약/키워드: resolution correction

검색결과 455건 처리시간 0.03초

Implementation of Adaptive Shading Correction System Supporting Multi-Resolution for Camera

  • Ha, Joo-Young;Song, Jin-Geun;Im, Jeong-Uk;Min, Kyoung-Joong;Kang, Bong-Soon
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 한국신호처리시스템학회 2006년도 하계 학술대회 논문집
    • /
    • pp.25-28
    • /
    • 2006
  • In this paper, we say the shading correction system supporting multi-resolution for camera. The shading effect is caused by non-uniform illumination, non-uniform camera sensitivity, or even dirt and dust on glass (lens) surfaces. In general this shading effect is undesirable [1]. Eliminating it is frequently necessary for subsequent processing and especially when quantitative microscopy is the fine goal. The proposed system is available on thirty nine kinds of image resolutions scanned by interlaced and progressive type. Moreover, the system is using various continuous quadratic equations instead of using the piece-wise linear curve which is composed of multiple line segments. Finally, the system could correct the correct effect without discontinuity in any image resolution. The proposed system is also experimentally demonstrated with Xilinx Virtex FPGA XCV2000E- 6BG5560 and the TV set.

  • PDF

Resolution Limit Analysis of Isolated Patterns Using Optical Proximity Correction Method with Attenuated Phase Shift Mask (Attenuated Phase Shift Mask에 광 근접 효과 보정을 적용한 고립 패턴의 해상 한계 분석)

  • 김종선;오용호;임성우;고춘수;이재철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제13권11호
    • /
    • pp.901-907
    • /
    • 2000
  • As the minimum feature size for making ULSI approaches the wavelength of light source in optical lithography, the aerial image is so hardly distorted because of the optical proximity effect that the accurate mask image reconstruction on wafer surface is almost impossible. We applied the Optical Proximity Correction(OPC) on isolated patterns assuming Attenuated Phase Shift Mask(APSM) as well as binary mask, to correct the widening of isolated patterns. In this study, we found that applying OPC to APSM shows much better improvement not only in enhancing the resolution and fidelity of t도 images but also in enhancing the process margin than applying OPC to the binary mask. Also, we propose the OPC method of APSM for isolated patterns, the size of which is less than the wavelength of the ArF excimer laser. Finally, we predicted the resolution limit of optical lithography through the aerial image simulation.

  • PDF

Bias-correction of Dual Polarization Radar rainfall using Convolutional Autoencoder

  • Jung, Sungho;Le, Xuan Hien;Oh, Sungryul;Kim, Jeongyup;Lee, GiHa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.166-166
    • /
    • 2020
  • Recently, As the frequency of localized heavy rains increases, the use of high-resolution radar data is increasing. The produced radar rainfall has still gaps of spatial and temporal compared to gauge observation rainfall, and in many studies, various statistical techniques are performed for correct rainfall. In this study, the precipitation correction of the S-band Dual Polarization radar in use in the flood forecast was performed using the ConvAE algorithm, one of the Convolutional Neural Network. The ConvAE model was trained based on radar data sets having a 10-min temporal resolution: radar rainfall data, gauge rainfall data for 790minutes(July 2017 in Cheongju flood event). As a result of the validation of corrected radar rainfall were reduced gaps compared to gauge rainfall and the spatial correction was also performed. Therefore, it is judged that the corrected radar rainfall using ConvAE will increase the reliability of the gridded rainfall data used in various physically-based distributed hydrodynamic models.

  • PDF

The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT (심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교)

  • Song, Jae hyuk;Kim, Kyeong Sik;Lee, Dong Hoon;Kim, Sung Hwan;Park, Jang Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제19권2호
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose When the patients takes myocardial perfusion SPECT using $^{201}Tl$, the operator gives the patients an injection of $^{201}Tl$. But the uniformity correction map in SPECT uses $^{99m}Tc$ uniformity correction map. Thus, we want to compare the image quality when it uses $^{99m}Tc$ uniformity correction map and when it uses $^{201}Tl$ uniformity correction map. Materials and Methods Phantom study is performed. We take the data by Asan medical center daily QC condition with flood phantom including $^{201}Tl$ 21.3 kBq/mL. After postprocessing with this data, we analyze CFOV integral uniformity(I.U) and differential uniformity(D.U). And we take the data with Jaszczak ECT Phantom by American college of radiology accreditation program instruction including $^{201}Tl$ 33.4 kBq/mL. After post processing with this data, we analyze spatial Resolution, Integral Uniformity(I.U), coefficient of variation(C.V) and Contrast with Interactive data language program. Results In the flood phantom test, when it uses $^{99m}Tc$ uniformity correction map, Flood I.U is 3.6% and D.U is 3.0%. When it uses $^{201}Tl$ uniformity correction map, Flood I.U is 3.8% and D.U is 2.1%. The flood I.U is worsen about 5%, but the D.U is improved about 30% inversely. In the Jaszczak ECT phantom test, when it uses $^{99m}Tc$ uniformity correction map, SPECT I.U, C.V and contrast is 13.99%, 4.89% and 0.69. When it uses $^{201}Tl$ uniformity correction map, SPECT I.U, C.V and contrast is 11.37%, 4.79% and 0.78. All of data are improved about 18%, 2%, 13% The spatial resolution was no significant changes. Conclusion In the flood phantom test, Flood I.U is worsen but Flood D.U is improved. Therefore, it's uncertain that an image quality is improved with flood phantom test. On the other hand, SPECT I.U, C.V, Contrast are improved about 18%, 2%, 13% in the Jaszczak ECT phantom test. This study has limitations that we can't take all variables into account and study with two phantoms. We need think about things that it has a good effect when doctors decipher the nuclear medicine image and it's possible to improve the image quality using the uniformity correction map of other radionuclides other than $^{99m}Tc$, $^{201}Tl$ when we make other nuclear medicine examinations.

  • PDF

QuickBird - Geometric Correction, Data Fusion, and Automatic DEM Extraction

  • Cheng, Philip;Toutin, Thierry;Zhang, Yun
    • Proceedings of the KSRS Conference
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.216-218
    • /
    • 2003
  • QuickBird satellite is quickly becoming the best choice for high-resolution mapping using satellite images. In this paper, we will describe the followings: (1) how to correct QuickBird data using different geometric correction methods, (2) data fusion using QuickBird panchromatic and multispectral data, and (3) automatic DEM extraction using QuickBird stereo data.

  • PDF

ATMOSPHERIC AEROSOL DETECTION AND ITS REMOVEAL FOR SATELLITE DATA

  • Lee, Dong-Ha;Lee, Kwon-Ho;Kim, Young-Joon
    • Proceedings of the KSRS Conference
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.598-601
    • /
    • 2006
  • Satellite imagery may contain large regions covered with atmospheric aerosol. A high-resolution satellite imagery affected by non-homogenous aerosol cover should be processed for land cover study and perform the radiometric calibration that will allow its future application for Korea Multi-Purpose Satellite (KOMPSAT) data. In this study, aerosol signal was separated from high resolution satellite data based on the reflectance separation method. Since aerosol removal has a good sensitivity over bright surface such as man-made targets, aerosol optical thickness (AOT) retrieval algorithm could be used. AOT retrieval using Look-up table (LUT) approach for utilizing the transformed image to radiometrically compensate visible band imagery is processed and tested in the correction of satellite scenery. Moderate Resolution Imaging Spectroradiometer (MODIS), EO-1/HYPERION data have been used for aerosol correction and AOT retrieval with different spatial resolution. Results show that an application of the aerosol detection for HYPERION data yields successive aerosol separation from imagery and AOT maps are consistent with MODIS AOT map.

  • PDF

VLSI Implementation of Adaptive Shading Correction System Supporting Multi-Resolution for Mobile Camera

  • Ha, Joo-Young;Lee, Sung-Mok;Jang, Won-Woo;Yang, Hoon-Gee;Kang, Bong-Soon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제31권12C호
    • /
    • pp.1201-1207
    • /
    • 2006
  • In this paper, we say the adaptive shading correction system supporting multi-resolution for mobile camera. The shading effect is caused by non-uniform illumination, non-uniform camera sensitivity, or even dirt and dust on glass (lens) surfaces. In general this shading effect is undesirable [1-3]. Eliminating it is frequently necessary for subsequent processing and especially when quantitative microscopy is the fine goal. The proposed system is available on thirty nine kinds of image resolutions scanned by interlaced and progressive type. Moreover, the system is using forty kinds of continuous quadratic equations instead of using the piece-wise linear curve which is composed of multiple line segments. Finally, the system could correct the shading effect without discontinuity in any image resolution. The proposed system is implemented in VLSI with cell library based on Hynix $0.25{\mu}m$ CMOS technology.

Color Correction Using Polynomial Regression in Film Scanner (다항회귀를 이용한 필름 스캐너에서의 색보정)

  • 김태현;백중환
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제40권1호
    • /
    • pp.43-50
    • /
    • 2003
  • Today, the demand of image acquisition systems grows as the multimedia applications go on increasing greatly. Among the systems, film scanner is one of the systems, which can acquire high quality and high resolution images. However due to the nonlinear characteristic of the light source and sensor, colors of the original film image do not correspond to the colors of the scanned image. Therefore color correction mr the scanned digital image is essential in the film scanner. In this paper, polynomial regression method is applied for the color correction to CIE $L^{*}$ $a^{*}$ $b^{*}$ color model data converted from RGB color model data. A1so a film scanner hardware with 12 bit color resolution for each R, G, B and 2400 dpi was implemented by using TMS320C32 DSP chip and high resolution line sensor. An experimental result shows that the average color difference ($\Delta$ $E^{*}$$_{ab}$ ) is reduced from13.48 to 8.46.6.6.6.6.

The Analysis of Sea Surface Temperature Distribution Using Atmospheric Corrected Landsat Imagery (대기보정된 Landsat 위성영상을 이용한 해수온도 분석)

  • Kim, Gi-Hong;Hong, Sung-Chang;Youn, Jun-Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제26권3호
    • /
    • pp.219-225
    • /
    • 2008
  • There are many problems in monitering environmental change around of nuclear power station, because interesting area is coastal and relatively large. The ground resolution of Landsat ETM+ imagery is high (30 m), but this imagery does not have enough informations for conducting atmospheric correction in evaluating sea surface temperatures. On the other hand, while it is possible to conduct atmospheric correction using MODIS imagery with it's two infrared bands, it's resolution is relatively low (1 km). Therefore, atmospheric corrected high resolution temperature information can be obtained from these two satellite images. In this study, digital numbers of Landsat ETM+ data in interesting area are georeferenced, converted to effective temperatures based on radiance value, and then the atmospheric correction is conducted using MODIS data. As a result, about $3.5^{\circ}C$ temperature differences were detected in comparing sea surface temperature of the surrounding area of Uljin nuclear power station with it of the same area located 5km far east.

Research of Phase Correlation Method for Identifying Quantitative Similarity in Adjacent Real-time Streaming Frame

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-seung;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 한국농업기계학회 2017년도 춘계공동학술대회
    • /
    • pp.157-157
    • /
    • 2017
  • To minimize the damage by wild birds and acquire the benefits such as protection against weeds and maintenance of water content in soil, the mulching black color vinyl after seeding should be carried out. Non-contact and non-destructive methods that can continuously determine the locations are necessary. In this study, a crop position detection method was studied that uses infrared thermal image sensor to determine the cotyledon position under vinyl mulch. The moving system for acquiring image arrays has been developed for continuously detecting crop locations under plastic mulching on the field. A sliding mechanical device was developed to move the sensor, which were arranged in the form of a linear array, perpendicular to the array using a micro-controller integrated with a stepping motor. The experiments were conducted while moving 4.00 cm/s speed of the IR sensor by the rotational speed of the stepping motor based on a digital pulse width modulation signal from the micro-controller. The acquired images were calibrated with the spatial image correlation. The collected data were processed using moving averaging on interpolation to determine the frame where the variance was the smallest in resolution units of 1.02 cm. Non-linear integral interpolation was one of method for analyzing the frequency using the normalization image and then arbitrarily increasing the limited data value of $16{\times}4pixels$ in one frame. It was a method to relatively reduce the size of overlapping pixels by arbitrarily increasing the limited data value. The splitted frames into 0.1 units instead of 1 pixel can propose more than 10 times more accurate and original method than the existing correction method. The non-integral calibration method was conducted by applying the subdivision method to the pixels to find the optimal correction resolution based on the first reversed frequency. In order to find a correct resolution, the expected location of the first crop was indicated on near pixel 4 in the inversion frequency. For the most optimized resolution, the pixel was divided by 0.4 pixel instead of one pixel to find out where the lowest frequency exists.

  • PDF