• Title/Summary/Keyword: resistant capacity

Search Result 303, Processing Time 0.027 seconds

Evaluation of physicochemical and biological properties of python fat (Python bivittatus)

  • Pham Thi Quyen;Le Pham Tan Quoc
    • Food Science and Preservation
    • /
    • v.30 no.5
    • /
    • pp.758-769
    • /
    • 2023
  • The main aim of this study was to determine python fat's several physicochemical properties, including dimensions, color, structure, acid value (AV), saponification value (SV), density, and recovery efficiency. The optimum yield obtained was approximately 80.40% at 180℃ for 60 min with an AV of 0.3366 and SV of 179.56 mg KOH/g. Fatty acids, comprising oleic acid (72.462%), palmitic acid (26.243%), linolenic acid (0.835%), and myristic acid (0.459%), were identified using gas chromatography-mass spectrometry (GC-MS). The python fat had a very weak antioxidant capacity and almost no antibacterial ability with gram-positive (Staphylococcus aureus - ATCC 25923 and Bacillus cereus - ATCC 10876) and gram-negative (Escherichia coli - ATCC 25922 and Salmonella enterica - ATCC 35664) bacteria (used the paper disc diffusion method for antibiotic susceptibility testing). Moreover, python fat is considered to be very resistant to high temperatures.

A simple approach for quality evaluation of non-slender, cast-in-place piles

  • Zhang, Ray Ruichong
    • Smart Structures and Systems
    • /
    • v.4 no.1
    • /
    • pp.1-17
    • /
    • 2008
  • This study proposes a conceptual framework of in-situ vibration tests and analyses for quality appraisal of non-slender, cast-in-place piles with irregular cross-section configuration. It evaluates a frequency index from vibration recordings to a series of impulse loadings that is related to total soil-resistance forces around a pile, so as to assess if the pile achieves the design requirement in terms of bearing capacity. In particular, in-situ pile-vibration tests in sequential are carried out, in which dropping a weight from different heights generates series impulse loadings with low-to-high amplitudes. The high-amplitude impulse is designed in way that the load will generate equivalent static load that is equal to or larger than the designed bearing capacity of the pile. This study then uses empirical mode decomposition and Hilbert spectral analysis for processing the nonstationary, short-period recordings, so as to single out with accuracy the frequency index. Comparison of the frequency indices identified from the recordings to the series loadings with the design-based one would tell if the total soil resistance force remains linear or nonlinear and subsequently for the quality appraisal of the pile. As an example, this study investigates six data sets collected from the in-situ tests of two piles in Taipu water pump project, Jiangshu Province of China. It concludes that the two piles have the actual axial load capacity higher than the designed bearing capacity. The true bearing capacity of the piles under investigation can be estimated with accuracy if the amplitude of impact loadings is further increased and the analyses are calibrated with the static testing results.

Experimental research on seismic behavior of novel composite RCS joints

  • Men, Jinjie;Guo, Zhifeng;Shi, Qingxuan
    • Steel and Composite Structures
    • /
    • v.19 no.1
    • /
    • pp.209-221
    • /
    • 2015
  • Results from an experimental study on the seismic response of six composite reinforced concrete column-to-steel beam interior joints are presented. The primary variable investigated is the details in the joint. For the basic specimen, the main subassemblies of the beam and column are both continuous, and the steel beam flanges extended to the joint are partly cut off. Transverse beam, steel band plates, cove plates, X shape reinforcement bars and end plates are used in the other five specimens, respectively. After the joint steel panel yielded, two failure modes were observed during the test: local failure in Specimens 1, 2 and 4, shear failure in Specimens 3, 5 and 6. Specimens 6, 3, 5 and 4 have a better strength and deformation capacity than the other two specimens for the effectiveness of their subassemblies. For Specimens 2 and 4, though the performance of strength degradation and stiffness degradation are not as good as the other four specimens, they all have excellent energy dissipation capacity comparing to the RC joint, or the Steel Reinforced Concrete (SRC) joint. Based on the test result, some suggestions are presented for the design of composite RCS joint.

Diurnal changes of Tissue Water Relations in Two Allopatric Tree Species (이소적 두 수종의 수분관계 일변화)

  • Park, Yong-Mok
    • The Korean Journal of Ecology
    • /
    • v.19 no.5
    • /
    • pp.453-463
    • /
    • 1996
  • Diurnal changes of microclimatic conditions and tissue water relations were measured at two sites where Carpinus laxiflora and C. cordata were allopatrically distributed. The microclimatic conditions at a site where C. laxiflora was distributed produced severe water stress condition during summer months. Daily maximum temperature reached $30.4^\circC$ and the highest vapor pressure deficit was 1.31 KPa when 13 rainless days were continued. During this period soil water content decreased to below the field capacity even at a depth of 20 cm and xylem pressure potential also decreased to ­2.04 MPa. However, turgor potential was maintained more than 0.4 MPa. Patterns of stomatal conductance were changed with evaporative demand and soil water availability. On the other hand, microclimatic conditions at a site where C. cordata was distributed were moderate water strees condition compared with those at a site C. laxiflora was distributed. Though soil water content was maintained above field capacity C. cordata showed a remarkable decrease in turgor potential and stomatal conductance throughout the experiment. These results indicate that there is a difference in habitat characteristics between the two species and C. laxiflora is more resistant than C. cordata to water stress.

  • PDF

Estimation of the Optimal Dredge Amount to Maintain the Water Supply Capacity on Asan-Lake (아산호 용수공급용량 유지를 위한 적정 준설량 산정)

  • Jang Tae-Il;Kim Sang-Min;Kang Moon-Seong;Park Seung-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.2
    • /
    • pp.45-55
    • /
    • 2006
  • This study analyze the hydrologic conditions and the effects of selected runoff characteristics as an attempt to estimate the optimal dredge amount for Asan Lake in Korea. The runoff feature was calculated by utilizing the water balance simulation from DIROM (Daily Irrigation Reservoir Operation Model), which allowed changes in landuse to be quantified using remote sensing for 14 years. The distribution of prospective sediment deposits was been tallied based on the changes in landuse, and quantity of incoming sediment estimated. From these findings, we were then able to simulate the fluctuation of water level, gauging the pumping days not already in use, to determine the frequency of the distribution for around the. requirement annual water storage and the changing water level. The optimal dredge amount was calculated on the basis of the distribution of frequency, taking into account the design criteria for agricultural water with the 10-year frequency of resistant capacity.

Heavy Metal Uptake by Native Plants in Mine Hazard Area (광해지역 토착 자생식물에 의한 중금속 흡수)

  • Choi, Hyung-Wook;Choi, Sang-Il;Yang, Jae-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.3
    • /
    • pp.27-33
    • /
    • 2010
  • The purpose of this study was in search of native plant species showing metal-resistant property and excessively accumulating heavy metals in metal-contaminated soil or abandoned mines as well as in evaluation of applicability of phytoremediation. In the study area, species showing excessively accumulating heavy metals were a shepherd´s purse, pampas grass, a Korean lettuce, a Hwansam vine, the Korean persicary, a foxtail, a goosefoot, and a water pepper. The first screened plant species in Sambo mine were as shepherd's purse, Korean lettuce and pampas grass Among them the shepherd´s purse can be excluded because it is a seasonal plant and has lower removal capacity for heavy metals. The Korean lettuce was also excluded because of having lower removal capacity for heavy metals. Pampas grass is a highly bionic plant species constantly growing from spring. However it has weak points such as little accumulation capacity for zinc as well as small values of an accumulation factor and a translocation factor. Another problem is regarded as removal of roots after the clean up if pampas grass is applied to a farmland. In Sanyang mine, wormwood and Sorijaengi were considered as adaptable species.

Experimental study of the behavior of composite timber columns confined with hollow rectangular steel sections under compression

  • Razavian, Leila;Naghipour, Morteza;Shariati, Mahdi;Safa, Maryam
    • Structural Engineering and Mechanics
    • /
    • v.74 no.1
    • /
    • pp.145-156
    • /
    • 2020
  • There are separate merits and demerits to wood and steel. The combination of wood and steel as a compound section is able to improve the properties of both and ultimately increase their final bearing capacity. The composite cross-section made of steel and wood has higher hardness while showing more ductility and the local buckling of steel is delayed or completely prevented. The purpose of this study is to investigate the behavior of composite columns enclosed in wooden logs and the hollow sections of steel that will be examined in a laboratory environment under the axial load to determine the final bearing capacity and sample deformation. In terms of methodology, steel sheet and carbon fiber reinforced polymer sheet (FRP) are tested to construct hollow rectangular sections and reinforce timber. Besides, the method of connecting hollow sections and timber including glue and screw has been also investigated. As a result, timber lumber enclosed with carbon fiber-reinforced polymer sheets in which fibers are horizontally located at 90° are more resistant with better ductility.

A Experimental Study on the Construction Material Using the Circulation Resources (폐콘크리트 순환자원을 이용한 건설재료의 특성연구)

  • Hong, Se-Hwa;Son, Ki-Sang;Choi, Jea-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.41-46
    • /
    • 2010
  • This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. This result has same decreasing proportion to tensile strength of the material. Resistant capacity change of beam varying with recycled powder mixture has been decreased down to 60% of normal concrete bean capacity, while there are 80% decrease of material strength. But strength and capacity change has same consistent decrease ratio. It is found that recycled powder with approximately 15% unit concrete volume can be replaced with cement in reasonable admixture mixing condition.

Improvement and Evaluation of Seismic Resistant Performance of Reinforced Concrete Infilled Masonry Frame (철근콘크리트 프레임면내 조적벽체의 내진성능 평가 및 개선기술)

  • Shin, Jong-Hack;Ha, Gee-Joo;Jun, Ha-Suk;Lee, Jong-Chan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.147-155
    • /
    • 2000
  • Five reinforced concrete rigid frame and masonry infilled wall and cut off type masonry infilled wall were tesed during vertical and cyclic loads simultaneously. Experimental programs were accomplished to improve and evaluate the structural performance of test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Test variables are hoop reinforcement ratio, with or without masonry infilled wall, and masonry method. All the specimens were constructed in one-third scale size. Based on the test results, the following conclusions can be made. For masonry infilled wall(IFB-1), maximum horizontal capacity was increased by 1.45 time in comparision with that of rigid frame(FB-0). For cut off masonry infilled wall (IFBC-1~3), maximum horizontal capacity was increased by 1.73~1.98 time in comparision with that of rigid frame(FB-0). For cut off masonry infilled wall(IFBG-1~3), ductility was increased by 1.48~2.08 time in comparision with that of masonry infilled wall (IFB-1).

  • PDF

Seismic failure analysis and safety assessment of an extremely long-span transmission tower-line system

  • Tian, Li;Pan, Haiyang;Ma, Ruisheng;Dong, Xu
    • Structural Engineering and Mechanics
    • /
    • v.71 no.3
    • /
    • pp.305-315
    • /
    • 2019
  • Extremely long-span transmission tower-line system is an indispensable portion of an electricity transmission system, and its failures or collapse can impact on the entire electricity grid, affect the modern life, and cause great economic losses. It is therefore imperative to investigate the failure and safety of the transmission tower subjected to ground motions. In the present study, a detailed finite element (FE) model of a representative extremely long-span transmission tower-line system is established. A segmental damage indicator (SDI) is proposed to quantitatively assess the damage level of each segment of the transmission tower under earthquakes. Additionally, parametric studies are conducted to investigate the influence of different ground motions and incident angles on the ultimate capacity and weakest segment of the transmission tower. Finally, the collapse fragility curve in terms of the maximum SDI value and PGA is plotted for the exampled transmission tower. The results show that the proposed SDI can quantitatively assess the damage level of the segments, and thus determine the ultimate capacity and weakest segment of the transmission tower. Moreover, the different ground motions and incident angles have a significant influence on the SDI values of the transmission tower, and the collapse fragility curve is utilized to evaluate the collapse resistant capacity of the transmission tower subjected to ground motions.