A study Grinding Characteristic of CBN Wheel (CBN 휠의 연삭특성에 관한 비교연구)

  • 안병민;원종호;김건희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.315-320
    • /
    • 2001
  • Ultra-abrasives such as diamond and CBN have used to maintain accuracy and form deviation for superalloy etc. This study contains the dry cylindrical grinding of metals with Vitrified-bond CBN wheel and Resinoid-bond CBN wheel. For various condition of grinding speed, workpiece speed, grinding depth and feed speed of table, the grinding resistance, the surface roughness, and material removal are measured and discussed.

  • PDF

Physical Properties and Sulfidation Kinetics of Mn-Based Sorbent for Hydrogen Sulfide Removal (황화수소 제거를 위한 망간계 탈황제의 물리적 특성과 황화반응 속도)

  • Oh, Kwang-Joong;Shon, Byung-Hyun;Choi, Eun-Hwa;Yi, Gang Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2067-2076
    • /
    • 2000
  • The experiments have been made to develop manganese-based sorbent(MT, MFT) for the removal of hydrogen sulfide from simulated hot coal gases. Manganese-based sorbents were tested in an ambient-pressure fixed-bed reactor to calculate H2S removal efficiency. and a three hole jet attrition tester to characterize the sorbent physical properties. According to the experimental results of attrition test. the attrition resistance of 5% bentonite containing sorbent was higher than that of 2% bentonite. The attrition resistances of both sorbents increased with induration temperature. Effects of sulfidation temperature. space velocity. and $H_2S$ concentrations on the $H_2S$ removal efficiency were investigated. Experimental results showed that $H_2S$ could be removed from 5,100ppmv to 20ppmv at $450^{\circ}C$, and to 30~65ppmv at $550{\sim}650^{\circ}C$ for both MT/MFT sorbents. As for the change of space velocity, the breakthrough time was decreased with space velocity.

  • PDF

Effects of Surface Water Chemistry and Physicochemical Characteristics of Humic Acid on Fouling of Membrane (원수의 수질화학과 HA의 물리화학적 특성이 막 오염에 미치는 영향)

  • Bae, Jin-Youl;Han, Ihnsup;Park, Sung-Ho;Shin, Jee-Won
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.242-247
    • /
    • 2005
  • In this study, we investigated the removal efficiencies of pollutants and permeate fluxes depending on chemistry of feed water, various molecular weight cut-offs (MWCOs) and materials of membrane, operating pressure. We used seven MWCO membranes of YC0.5, YM1, YM3, YM10, YM30, YM100 and PM30, humic acid solution and surface water as feed water, and examined variation in permeate flux. Results of TOC removal experiment demonstrate that MWCO lower 1,000daltons could remove humic acid effectively. As increasing solution pH and decreasing divalent cations ($Ca^{2+}$) concentration, TOC removal increased. But $UV_{254}$ removal efficiency increased with higher divalent cation concentration and solution pH. Membrane fouling increased with increasing electrolyte (NaCl), divalent cation concentration and decreasing solution pH. In spite of initial permeate flux of the hydrophobic membrane (PM30) was higher than that of the hydrophilic membrane (YM30), flux decline of PM30 was significant during operation. At higher operating pressure, compactness of the cake layer on the membrane surface increased, resulting in gradual increase in hydraulic resistance.

A COMPARATIVE STUDY OF THE RESISTANCE TO DISLODGEMENT OF FIXED PROSTHESES USING $BIO-PIN^{(R)}$ ($Bio-pin^{(R)}$을 이용한 고정성 보철물의 탈락저항강도의 비교연구)

  • Yi Jong-Won;Cho In-Ho;Lee Jong-Hyuk;Kim Seung-Ki
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.176-190
    • /
    • 2005
  • Statement of problem. The current trend in prosthodontics is the adoption of a conservative approach to preparing dental prostheses by minimizing the amount of sound tooth structure removal during preparation. Purpose. The major disadvantage of the adhesion bridge is the inherently poor resistance to dislodgement that its use in areas subjected to high occlusal load is limited. The purpose of this study was to compare the dislodgement resistance of $Bio-pin^{(R)}$, conventional 3-unit and adhesion bridges. Material and methods. The experimental groups were classified as follows : Group I : 3-unit bridge cemented using $Super-Bond^{(R)}$ C&B Group II : Adhesion bridge cemented using $Super-Bond^{(R)}$ C&B Group III : $Bio-pin^{(R)}$ design adhesion bridge without incorporation of $Bio-pin^{(R)}$ (cemented using $Super-Bond^{(R)}$ C&B) Group IV-1 : $Bio-pin^{(R)}$ retained adhesion bridge incorporating a single $Bio-pin^{(R)}$ (cemented using $Super-Bond^{(R)}$ C&B) Group IV-2 : $Bio-pin^{(R)}$ retained adhesion bridge incorporating a single $Bio-pin^{(R)}$ (cemented using $Panavia^{(R)}$ F) Group V : $Bio-pin^{(R)}$ retained adhesion bridge incorporating two $Bio-pins^{(R)}$ (cemented using $Super-Bond^{(R)}$ C&B) Results. The results of this study were as follows : 1. Significant differences in dislodgement resistance of the restorations were found between Group I, Group II and Group III (p<0.05). No significant differences in dislodgement resistance of the restorations were observed between Group I Group IV-1 and Group V. However, there were significant differences in dislodgement resistance between Group II and the other groups (p<0.05). 2. No significant differences in dislodgement resistance of the restorations were observed between GroupIV-1 and GroupIV-2, both of which utilized a single $Bio-pin^{(R)}$. However, significant differences were observed when Group III was compared to either GroupIV-1 or Group V (p<0.05). 3. No significant differences in dislodgement resistance relative to the type of dental cements used were found. Conclusion. From the above results, it is concluded that the dislodgement resistance of $Bio-pin^{(R)}$ bridge restorations utilizing a single $Bio-pin^{(R)}$ is similar to that of a conventional 3-unit bridge. The results also suggest that $Bio-pin^{(R)}$ bridge restorations using a single $Bio-pin^{(R)}$ are a viable alternative to the conventional 3-unit bridge when minimal removal of sound tooth structure and fulfillment of both function and esthetic aspects are considered.

Design of air-cooled waste heat removal system with string type direct contact heat exchanger and investigation of oil film instability

  • Moon, Jangsik;Jeong, Yong Hoon;Addad, Yacine
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.734-741
    • /
    • 2020
  • A new air-cooled waste heat removal system with a direct contact heat exchanger was designed for SMRs requiring 200 MW of waste heat removal. Conventional air-cooled systems use fin structure causing high thermal resistance; therefore, a large cooling tower is required. The new design replaces the fin structure with a vertical string type direct contact heat exchanger which has the most effective performance among tested heat exchangers in a previous study. The design results showed that the new system requires a cooling tower 50% smaller than that of the conventional system. However, droplet formation on a falling film along a string caused by Rayleigh-Plateau instability decreases heat removal performance of the new system. Analysis of Rayleigh-Plateau instability considering drag force on the falling film surface was developed. The analysis results showed that the instability can be prevented by providing thick string. The instability is prevented when the string radius exceeds the capillary length of liquid by a factor of 0.257 under stagnant air and 0.260 under 5 m/s air velocity.

Operating Characteristics of Two Stage Membrane Bioreactor (2단형 막분리 활성슬러지법(Two Stage MBR)의 운전 특성에 관한 고찰)

  • Park, Jae-Roh;Lim, Hyun-man;Kim, Eoung Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.141-150
    • /
    • 2002
  • Two-stage membrane bioreactor using submerged hollow fiber membrane was applied in laboratory scale to treat nitrogen and phosphorus of domestic wastewater. Alum as the flocculant and adsorbent was added into the anaerobic basin of two-stage membrane bioreactor and mixed liquid of aerabic basin was recycled to the anaerobic basin for the purpose of nitrogen removal. Experiment was carried out to find removal efficient of phosphorous and nitrogen components in the mixed liquid, and the stability of the permeate flux and pressure of two-stage membrane bioreactor. In case of alum was added as the flocculant and adsorbent into the anaerobic basin, soluble phosphorus removal efficient was relatively higher and total permeate resistance(Rtot) was more increased out nitrogen removal efficient was lower as the result of lack of alkalinity and insufficient nitrification process than the case of alum was not added.

Fabrication and Electrical Properties of Highly Organized Single-Walled Carbon Nanotube Networks for Electronic Device Applications

  • Kim, Young Lae
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.1
    • /
    • pp.66-69
    • /
    • 2017
  • In this study, the fabrication and electrical properties of aligned single-walled carbon nanotube (SWCNT) networks using a template-based fluidic assembly process are presented. This complementary metal-oxide-semiconductor (CMOS)-friendly process allows the formation of highly aligned lateral nanotube networks on $SiO_2/Si$ substrates, which can be easily integrated onto existing Si-based structures. To measure outstanding electrical properties of organized SWCNT devices, interfacial contact resistance between organized SWCNT devices and Ti/Au electrodes needs to be improved since conventional lithographic cleaning procedures are insufficient for the complete removal of lithographic residues in SWCNT network devices. Using optimized purification steps and controlled developing time, the interfacial contact resistance between SWCNTs and contact electrodes of Ti/Au is reached below 2% of the overall resistance in two-probe SWCNT platform. This structure can withstand current densities ${\sim}10^7A{\cdot}cm^{-2}$, equivalent to copper at similar dimensions. Also failure current density improves with decreasing network width.

Comparative study of removal torque of 3 different hydroxyapatite coated implants in the femur of rabbits (가토의 대퇴골에 식립한 3종류의 수산화인회석 코팅 임플란트에 대한 제거회전력 비교 연구)

  • Kim, Sang-Soo;Lee, Ju-Hyung;Yu, Seok-Hyun;Lee, Hyung-Ju;Moon, Jee-Won;Park, In-Sook;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.49-53
    • /
    • 2011
  • Introduction: This study compared the strength of osseointegration as determined by the resistance to reverse torque rotation of three different hydroxyapatite coated implants in the rabbit femur model. Materials and Methods: Three hydroxyapatite coated implants (HAPTITE), Tapered Screw-Vent (TSV) and BioTite-H - were used. A total of 40 implants were placed in the femur of 20 adult male rabbits. The animals were divided into two groups. In group A (n=10); one HAPTITE was placed into each right femur and one TSV was placed into each left femur. In group B (n=10); one HAPTITE was placed into each right femur and one BioTite-H was placed into each left femur. Five rabbits of each group were sacrificed at 4 and 8 weeks. The implants were removed by reverse torque rotation using a digital torque-measuring device. A total of 40 implants in 20 rabbits were used for the removal torque measurements. Results: In the Group A, 4 weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $70.7{\pm}31.6$ N cm and $28.9{\pm}15.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $87.9{\pm}26.2$ N cm and $54.9{\pm}22.4$ N cm, respectively. In the Group B, 4 weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $58.0{\pm}29.6$ N cm and $37.7{\pm}14.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $91.4{\pm}47.1$ N cm and $30.8{\pm}9.8$ N cm. HAPTITE showed a higher removal torque than the other implants. Conclusion: These results suggest that HAPTITE increases the strength of osseointegration significantly as determined by the resistance to reverse torque rotation.

Effects of Leaf and Pod Removal on Photosynthesis and Assimilate Partition in Soybean (적엽ㆍ제협처리가 콩의 광합성과 동화물질 배분에 미치는 영향)

  • Woong Tae, Kim;Rak Chun, Seong;Harry C, Minor
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.2
    • /
    • pp.159-165
    • /
    • 1993
  • To clarify the effects of sink demand for assimilate on leaf photosynthetic rate, tissue composition, and leaf senescence of soybean [Glycine max (L.) Merr.] J plants, pod and leaf tissues were removed at growth stage $R^3$. Plant responses were measured every 10days from 2 through 42days following treatment. Leaves of depodded plants exhibited increased starch and chlorophyll contents and specific leaf weight. Stomatal resistance was also increased and leaf photosynthetic rate was reduced. Dry weight of vegetative tissues except leaves was increased by pod removal. Leaf removal resulted in a decreased starch content of leaves from 22 to 42days after treatment and that of roots at all sampling times. Specific leaf weight was decreased while leaf photosynthetic rate was increased. Stomatal resistance and chlorophyll content were little affected. Weight per seed was decreased 3.0% by leaf removal. Except for the seed, tissue protein contents were increased by pod removal but decreased by leaf removal, however, seed protein content was not affected by either. Apparent senescence was delayed by depodding. Both apparent and functional senescence were accelerated by leaf removal.

  • PDF

Removal Characteristics of Lead by Immobilizing Agents and Immobilized Seaweed (고정화제와 고정화된 해조류에 의한 납의 제거 특성)

  • 이학성;서정호;서근학
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.83-87
    • /
    • 2001
  • In this study, the characteristics of lead removal by PVA and alginate bead which used widely as immobilizing agents were investigated, and the difference of removal amounts between pure PVA/alginate bead and Sargassum thunbergii immobilized bead was studied. All PVA beads, pure and S. thunbergii immobilized, reached an equilibrium state in about 1 hour, and S. thunbergii immobilized bead adsorbed more lead than pure one. But in the case of alginate beads, they needed much time, about 5 hours, to reach an equilibrium state, and adsorbed lead four times higher than PVA beads. Therefore, it was considered that alginate beads had more mass transfer resistance and function groups which adsorb lead such as hydroxyl, carboxyl and etc. than PVA bead. To examine the continuous usage of alginate beads, the process of adsorption/desorption of lead was conducted repeatedly. As the process proceeded, the amounts of lead adsorption decrease, so it was indicated that the non-desorbed lead from alginate bead at first adsorption/desorption process remained constantly.

  • PDF