• 제목/요약/키워드: resistance removal

검색결과 387건 처리시간 0.026초

Experimental and numerical study on progressive collapse of composite steel-concrete frames

  • Jing-Xuan Wang;Ya-Jun Shen;Kan Zhou;Yong Yang
    • Steel and Composite Structures
    • /
    • 제50권5호
    • /
    • pp.531-548
    • /
    • 2024
  • This paper presents an experimental investigation into the progressive collapse behavior of composite steel-concrete frames under various column removal scenarios. This study involves testing two two-bay, two-story composite frames featuring CFST columns and profiled steel decking composite slabs. Two removal scenarios, involving the corner column and middle column, are examined. The paper reports on the overall and local failure modes, vertical force-deformation responses, and strain development observed during testing. Findings indicate that structural failure initiates due to fracture and local buckling of the steel beam. Moreover, the collapse resistance and ductility of the middle column removal scenario surpass those of the corner column removal scenario. Subsequent numerical analysis reveals the significant contribution of the composite slab to collapse resistance and capacity. Additionally, it is found that horizontal boundary conditions notably influence the collapse resistance in the middle column removal scenario only. Finally, the paper proposes a simplified calculation method for collapse resistance, which yields satisfactory predictions.

우리나라 면체 여과식마스크 성능에 관한 연구 (A Experimental Study on the Performance of Filter-integrated Half-masks)

  • 변임근;이영섭
    • 한국안전학회지
    • /
    • 제5권3호
    • /
    • pp.3-7
    • /
    • 1990
  • This study is conducted to experiment on the performance test for 20 types of Filter-integrated Half-masks which could not only protect workers exposed to dusty environment, but also improve workability. Results and conclusions are as follows : 1) Respirators that removal efficiency of aerosols is 95 percent or more are 11 kinds(55%), and those who are 99.9 percent or more are 4 kinds(20%). Respirators that inhalation resistance is 4 mm in water or less are 13 kinds(65%), and those who are 6 mm in water or less are 17 kinds(85%). Respirators that efficiency of cumulative inhalation resistance is 100 percent or less are 11 kinds(55%) . 2) Respirators that resistance of moisture inhalation is 6 mm in water or less are 11 kinds(55%). and those who are 10 mm in water or less are 13 kinds(65cio), Respira'tors that ratio of removal efficiency for aerosols between dry and wet conditions is 95 percent or more are 9 kinds(45%). 3) Respirators which are not only 95 percent or more for removal efficiency of aersosls and 6 mm in water or less for inhalation resistance, but also 200 percent or less for efficiency of cumulative inhalation resistance, are 8 kinds(40%). Respirators which are not only 99.9 percent or more for removal efficiency and 6 mm in water or less for inhalation resistance, but also 100 percent or less for efficiency of cumulative inhalation resistance, are 3 kinds(15%). Respirators which are not only 95 percent or more for removal efficiency of aerosols and 6 mm in water or less for inhalation resistance, but also 200 percent or less for efficiency of cumulative inhalation resistance and 10 mm in water or less for resistance of moisture inhalation, are 6 kinds(30%) . 4) As standard rrlodel of artificial human head which would be perhaps different from the true one Is used to experiment fitness test, leakage rate is shown to be more or less high. However, artificial human head shall be accurately examined and follow-up studt. would be conducted in the future.

  • PDF

막표면의 케이크층 세정 방법에 따른 여과 저항값 비교 (Comparison of Filtration Resistances according to Membrane Cleaning Methods)

  • 한송희;장인성
    • 한국환경과학회지
    • /
    • 제25권6호
    • /
    • pp.817-827
    • /
    • 2016
  • The resistance in series model has been frequently used for determination of various filtration resistance to correctly understand the membrane fouling behaviour in MBR (membrane bio-reactor) for wastewater treatment. The cake layer resistance ($R_c$) which is commonly determined by calculation of flux dataset that are obtained empirically before and after removing the cake layer on membrane surface. However, the calculated Rc values are very dependent on the cleaning methods adapted for removal of cake layer. This study investigated how the various cleaning options affect $R_c$. Seven different cleaning methods were employed: i) ultrasonication (100 W, 10 min), ii) ultrasonication (200 W, 60 min), iii) ultrasonication (400 W, 120 min), iv) water rinsing in a shaker (100 rpm, 10 min), v) water rinsing in a shaker (300 rpm, 60 min), vi) water rinsing, vii) sponge scrubbing. For the hydrophilic PES membrane, the cake layer removal efficiencies ranged from 64% to 10%, indicating that the removal of cake layer was highly dependent on the cleaning options. For the hydrophobic PVDF membrane, the cake layer removal efficiencies ranged from 79% to 97%. Consequently, a standardized method for cake layer removal to determine cake resistance ($R_c$) is needed for correct interpretation of the fouling phenomena.

생물환원전극 미생물연료전지에서 외부저항 및 유입부하에 따른 유기물 및 질소 제거와 전기생산에 미치는 영향 (Effect of the Organic and Nitrogen Removal and Electricity Production on Changing the External Resistor and the Inflow Loading in the Biocathode Microbial Fuel Cell)

  • 김지연;김병군;김홍석;윤주환
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.556-562
    • /
    • 2015
  • In order to remove the organic substances and the nitrate-nitrogen contained in wastewater, some researchers have studied the simultaneous removal of organics and nitrogen by using different biocathode microbial fuel cells (MFCs). The operating conditions for removing the contaminants in the MFCs are the external resistances, HRTs, the concentration of the influent wastewater, and other factors. This study aimed to determine the effect of the external resistors and organic loading rates, from the changing HRT, on the removal of the organics and nitrogen and on the production of electric power using the Denitrification Biocathode - Microbial Fuel Cell (DNB-MFC). As regards the results of the study, the removal efficiencies of $SCOD_{Cr}$ did not show any difference, but the nitrate-nitrogen removal efficiencies were increased by decreasing the external resistance. The maximum denitrification rate achieved was $129.2{\pm}13.54g\;NO_3{^-}-N/m^3/d$ in the external resistance $1{\Omega}$, and the maximum power density was $3,279mW/m^3$ in $10{\Omega}$. When the DNB-MFC was operated with increasing influent organic and nitrate loading by reducing the HRTs, the $NO_3{^-}-N$ removal efficiencies were increased linearly, and the maximum nitrate removal rate was $1,586g\;NO^3{^-}-N/m^3/d$ at HRT 0.6 h.

바이오가스 마이크로 터빈 발전용 전처리시스템 전산유동해석 (Computational Fluid Dynamics Analysis of the Pretreatment System for Livestock BIO-GAS MGT Power Generation)

  • 허광범;박정극;임상규;김재훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.260-263
    • /
    • 2008
  • KEPCO(Korea Electric Power Corporation) is performing the nation's first biogas-MGT project as an effort to encourage the utilization of wasted biogas which contains useful CH4. The goals of this project are to develop the Pretreatment system of Livestock bio-gas and set up the biogas-MGT co-generation system. The project will not only utilze flared biogas as precious energy but also improve the economics of the plant a lot. The pretreatment system mainly consists of sulfur removal tower, biogas compressor and many filtering systems. A computational fluid dynamics study in the bio gas sulfur removal tower and sulfur absorption filter was carried out. Understanding of the flow in the sulfur removal tower and sulfur adsorption filter obtained by this study can be used to identify the problems in the sulfur removal tower and to improve the sulfur removal efficiency of the sulfur removal tower. Resistance material modeling is used to simulate the sulfur adsorption filter, and the resistance coefficient was adjusted to reflect the experimental pressure loss value. And the pressure loss change with the flowrate is predicted

  • PDF

횡구속 방법에 따른 고성능 RC 기둥 콘크리트의 내화특성 (Properties of Fire Endurance of High Performance RC Column with Laterral Confinement Method)

  • 황인성;김기훈;배연기;이보형;이재삼;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.553-556
    • /
    • 2004
  • This paper is to investigate the spalling and fire endurance of high performance RC column member with PP fiber and lateral confinement of metal lath and non fire resistance removal type form. According to test results, combination of PP fiber and metal lath as well as use fire resistance non removal type form had favorable fire resistance by discharging internal vapour pressure and lateral confining. After fire endurance test, compressive strength decreased markedly caused by internal expansion pressure and crack. Residual strength of plain concrete was decreased to $22\%$. The use of PP fiber and lateral confinement of metal lath and non removal type form enhanced the residual strength above $40\%$. Especially, the combination of $0.1\%$ of PP fiber and lateral confinement with the level of 2.3T exhibited more than $51\%$ of residual strength. Therefore, to improve fire endurance and spalling resistance, the combination of $0.1\%$ of PP fiber and metal lath with 2.3T can be the proper measure.

  • PDF

항생제 내성균 및 유전자제거를 위한 염소 CT 값 비교 (The CT values Comparisons for Antibiotic Resistant Bacteria and Resistant Genes by Chlorination)

  • 오준식;김성표
    • 한국습지학회지
    • /
    • 제16권2호
    • /
    • pp.269-274
    • /
    • 2014
  • 본 연구의 목적은 항생제 내성 균과 유전자 및, 항생제 내성 전달을 제어하는데 필요한 살균능 (CT, 농도 * 접촉 시간)을 서로 비교하는데 있다. 이를 위하여, 이를 위해 각기 다른 염소 주입농도(C)와 접촉시간(T)에 따라 각각의 항생제 내성 제거를 산정하였다. 그 결과 항생제 내성균 90%(1 log)이상 제어를 위해서는 CT 값(176~353 mg min/L)이 필요하였으며, 항생제 내성 유전자의 제거를 위한 CT 값은 195~372 mg min/L 이었다. 또한 항생제 내성 유전자의 전이 90% 이상 제거를 위한 CT 값은 187~489 mg min/L이었다. 따라서, 본 연구조건에서는 항생제 내성 유전자 및 유전자의 전이에 대한 제어를 위해서는 항생제 내성균 제어보다 더 높은 소독능이 필요함을 알 수 있었다.

Collapse resistance of steel frames in two-side-column-removal scenario: Analytical method and design approach

  • Zhang, JingZhou;Yam, Michael C.H.;Soltanieh, Ghazaleh;Feng, Ran
    • Structural Engineering and Mechanics
    • /
    • 제78권4호
    • /
    • pp.485-496
    • /
    • 2021
  • So far analytical methods on collapse assessment of three-dimensional (3-D) steel frames have mainly focused on a single-column-removal scenario. However, the collapse of the Federal Building in the US due to car bomb explosion indicated that the loss of multiple columns may occur in the real structures, wherein the structures are more vulnerable to collapse. Meanwhile, the General Services Administration (GSA) in the US suggested that the removal of side columns of the structure has a great possibility to cause collapse. Therefore, this paper analytically deals with the robustness of 3-D steel frames in a two-side-column-removal (TSCR) scenario. Analytical method is first proposed to determine the collapse resistance of the frame during this column-removal procedure. The reliability of the analytical method is verified by the finite element results. Moreover, a design-based methodology is proposed to quickly assess the robustness of the frame due to a TSCR scenario. It is found the analytical method can reasonably predict the resistance-displacement relationship of the frame in the TSCR scenario, with an error generally less than 10%. The parametric numerical analyses suggest that the slab thickness mainly affects the plastic bearing capacity of the frame. The rebar diameter mainly affects the capacity of the frame at large displacement. However, the steel beam section height affects both the plastic and ultimate bearing capacity of the frame. A case study on a six-storey steel frame shows that the design-based methodology provides a conservative prediction on the robustness of the frame.

보건용 마스크 초미세먼지 제거 성능 평가 및 재사용 연구 (Performance and reusability of certified and uncertified face masks)

  • 이해범;김서정;주흥수;조희주;박기홍
    • 한국입자에어로졸학회지
    • /
    • 제15권4호
    • /
    • pp.191-202
    • /
    • 2019
  • In this study, performance (particle removal efficiency and breathing resistance) of several commercially available face masks (electrostatic filter masks (KF80 certified), a nanofiber filter mask (KF80 certified), and an uncertified mask) with their filter structure and composition were evaluated. Also, effects of relative humidity (RH) of incoming air, water and alcohol exposure, and reusability on performance of face masks were examined. Monodisperse and polydisperse sodium chloride particles were used as test aerosols. Except the uncertified mask filter, PM2.5 removal efficiency was found to be higher than 90%, and the nanofiber filter mask had the highest quality factor due to the low pressure drop and high removal efficiency (nanofibers were arranged in a densely packed pore structure and contained a significant amount of fluorine in addition to carbon and oxygen). In the case of the KF80 certified mask, the removal efficiency was little affected when the RH of incoming air increased. When the mask filters were soaked in water, the removal efficiency of mask filters was degraded. In particular, the uncertified mask filter showed the highest removal efficiency degradation (26%). When the mask was soaked in alcohol, the removal efficiency also decreased with the greater degree than the water soaking case. The nanofiber mask filter showed the strongest resistance to alcohol exposure among tested mask filters. During evaluation of reusability of masks in real life, the removal efficiency of certified mask filter was less than 4% for 5 consecutive days (2 hours per day), while the removal efficiency of uncertified mask filter significantly decreased by 30% after 5 days.

Post-Cu CMP cleaning에서 연마입자 제거에 buffing 공정이 미치는 영향 (The effect of buffing on particle removal in Post-Cu CMP cleaning)

  • 김영민;조한철;정해도
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.537-537
    • /
    • 2008
  • Copper (Cu) has been widely used for interconnection structure in intergrated circuits because of its properties such as a low resistance and high resistance to electromigration compared with aluminuim. Damascene processing for the interconnection structure utilizes 2-steps chemical mechanical polishing(CMP). After polishing, the removal of abrasive particles on the surfaces becomes as important as the polishing process. In the paper, buffing process for the removal of colloidal silica from polished Cu wafer was proposed and demonstrated.

  • PDF