• Title/Summary/Keyword: resistance monitoring

Search Result 558, Processing Time 0.026 seconds

Numerical and laboratory investigations of electrical resistance tomography for environmental monitoring

  • Heinson Tania Dhu Graham
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.33-40
    • /
    • 2004
  • Numerical and laboratory studies have been conducted to test the ability of Electrical Resistance Tomography-a technique used to map the electrical resistivity of the subsurface-to delineate contaminant plumes. Two-dimensional numerical models were created to investigate survey design and resolution. Optimal survey design consisted of both downhole and surface electrode sites. Resolution models revealed that while the bulk fluid flow could be outlined, small-scale fingering effects could not be delineated. Laboratory experiments were conducted in a narrow glass tank to validate theoretical models. A visual comparison of fluid flow with ERT images also showed that, while the bulk fluid flow could be seen in most instances, fine-scale effects were indeterminate.

Corrosion Monitoring for Protected Systems using Thin-Film Electrical Resistance (TFER) Sensor

  • Lee, Seong-Min;Li, SeonYeob;Jung, Sung-Won;Kim, YoungGeun;Song, HongSeok;Won, Deok-Soo
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.112-116
    • /
    • 2006
  • This study has been conducted to monitor the corrosion rate of cathodically protected structure and corrosion inhibited system using multi-line thin-film electrical resistance (TFER) sensor in various environments. The field test data of TFER sensor for the corrosion monitoring of cathodically protected underground pipeline in soil environments and of corrosion inhibited gas heaters were also presented. The sensor was found to be a powerful method to commit the sensitive pick-up of small corrosion rate which can be observed in the cathodically protected and corrosion inhibited systems.

Characterization of Primary Dynamic Resistance in Resistance Spot Welding (저항 점 용접의 1차 동저항 특성에 관한 연구)

  • 조용준;이세헌;신현일;배경민
    • Journal of Welding and Joining
    • /
    • v.17 no.2
    • /
    • pp.97-103
    • /
    • 1999
  • The dynamic resistance monitoring in primary circuit is one of the important issues. Because in-process and real time quality assurance of resistance spot weld is needed to increase the product reliability. In this study, new dynamic resistance detecting method is proposed as a practical manner of weld quality assurance using instantaneous current and voltage measured at the primary circuit. and also, various patterns of primary dynamic resistance curve are characterized with the macro photograph and the weldability lobe curve. It is found that the primary dynamic resistance patterns are basically similar to those of the secondary, but there is evident advantage such as no extra devices are needed to obtain the quality information and eventually real time feedback control will be possible.

  • PDF

A monitoring survey on antimicrobial resistance of bacterial isolates from companion dogs in Incheon (인천지역 반려견 유래 세균의 항생제 내성 모니터링 조사)

  • Kim, Kyung-Mi;Cho, Min-Haneng;Lee, Seung-Hwan;Kim, Kyung-Ho;Lee, Jung-Gu;Lee, Sung-Mo
    • Korean Journal of Veterinary Service
    • /
    • v.42 no.2
    • /
    • pp.53-60
    • /
    • 2019
  • This study was performed to investigate antimicrobial resistance in bacterial isolates obtained from companion dogs in veterinary hospitals and an animal shelter in Incheon. Drug resistance was examined respectively with the isolates of Escherichia coli, Enterococcus faecalis, and Staphylococcus pseudintermedius. The prevalence of drug resistance was calculated for each bacterial species towards 163 E. coli isolates, 156 E. faecalis isolates, and 86 S. pseudintermedius isolates by using selected antimicrobials. E. coli isolates were highly resistant to ampicillin, ciprofloxacin and tetracycline (47.9%, 28.2% and 28.2%, respectively). E. faecalis isolates were highly resistant to quinupristin-dalfopristin, tetracycline, kanamycin, rifampicin (69.8%, 66.0%, 53.8% and 51.9%, respectively). Higher levels of resistance were detected for ampicillin, penicillin, tetracycline, erythromycin, trimethoprim/sulfamethoxazole, telithromycin in S. pseudintermedius isolates (83.7%~52.6%, respectively). Occurrence of methicillin-resistant S. pseudintermedius (MRSP) was confirmed by oxacillin disc diffusion method, resulted in 23.3% occurrence among the S. pseudintermedius isolates (20/86 strains). The occurrence ratio of multidrug-resistance in the isolates of E. coli, E. faecalis, and S. pseudintermedius was 34.5%, 56.9%, and 67.9%, respectively. In this study, higher levels of antimicrobial drug resistance were observed in bacterial isolates obtained from dogs in Incheon. A regular monitoring and surveillance program should be implemented to prevent the emergence and spread of the drug-resistant bacteria carried in companion dogs.

Electrode Force Characteristics of Micro Servogun (마이크로 서보건의 가압 특성)

  • 임창식;박승규;장희석
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.159-161
    • /
    • 2003
  • Electrode movement signal has been widely used in resistance spot welding system This study is to compare accelerometer signal with gap sensor signal in servo gun system. This study propose that accelerometer output signal is a useful technique of quality monitoring in resistance welding processes.

  • PDF

Fatigue performance monitoring of full-scale PPC beams by using the FBG sensors

  • Wang, Licheng;Han, Jigang;Song, Yupu
    • Smart Structures and Systems
    • /
    • v.13 no.6
    • /
    • pp.943-957
    • /
    • 2014
  • When subjected to fatigue loading, the main failure mode of partially prestressed concrete (PPC) structure is the fatigue fracture of tensile reinforcement. Therefore, monitoring and evaluation of the steel stresses/strains in the structure are essential issues for structural design and healthy assessment. The current study experimentally investigates the possibility of using fiber Bragg grating (FBG) sensors to measure the steel strains in PPC beams in the process of fatigue loading. Six full-scale post-tensioned PPC beams were exposed to fatigue loading. Within the beams, the FBG and resistance strain gauge (RSG) sensors were independently bonded onto the surface of tensile reinforcements. A good agreement was found between the recorded results from the two different sensors. Moreover, FBG sensors show relatively good resistance to fatigue loading compared with RSG sensors, indicating that FBG sensors possess the capability for long-term health monitoring of the tensile reinforcement in PPC structures. Apart from the above findings, it can also be found that during the fatigue loading, there is stress redistribution between prestressed and non-prestressed reinforcements, and the residual strain emerges in the non-prestressed reinforcement. This phenomenon can bring about an increase of the steel stress in the non-prestressed reinforcement.

Health monitoring of carbon fiber-reinforced polymer composites in γ-radiation environment using embedded fiber Bragg grating sensors

  • Jing Zhong;Feida Chen;Yuehao Rui;Yong Li;Xiaobin Tang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.3039-3045
    • /
    • 2023
  • Fiber-reinforced polymer (FRP) composites are considered suitable candidates for structural materials of spacecrafts due to their excellent properties of high strength, light weight, and corrosion resistance. An online health monitoring method for FRP composites must be applied to space structures. However, the application of existing health monitoring methods to space structures is limited due to the harsh space environment. Here, carbon fiber-reinforced polymer (CFRP) composites embedded with fiber Bragg grating (FBG) sensors were prepared to explore the feasibility of strain monitoring using embedded FBG sensors in γ-radiation environment. The analysis of the influence of radiation on the strain monitoring demonstrated that the embedded FBG can be successfully applied to the health monitoring of FRP composites in radiation environment.

A Study on the Resistance Spot Welding of Aluminum Alloy (I) (알루미늄 합금의 저항점 용접에 관한 연구 ( I ))

  • 김상필;홍태민;장희석
    • Journal of Welding and Joining
    • /
    • v.12 no.4
    • /
    • pp.127-140
    • /
    • 1994
  • Resistance spot welding has been widely used in the sheet metal joining processes because of its high productivity and convenience. In the resistance spot welding processes the size of molten nugget is a criterion to assess weld quality. Many research have founded on measuring weld nugget size at the same time monitoring welding process parameters such as dynamic resistance and electrode movement. With increasing demand of energy saving, many efforts were made to employ aluminum alloys that are lighter than steel and have relatively equivalent strength to steel in the automobile industry. In this paper, spot weldability of aluminum alloys for various welding conditions were examined by series of experiments. One of the 6000 series (Mg-Si) aluminum alloy, 6383-T4 was chosen, which is currently considered as a substitute for the galvanized steel. Dynamic resistance, electrode movement and corresponding nugget size were observed and compared to the case of steel. Finally, resistance spot welding of dissimilar material (galvanized steel-aluminum alloy) was attempted.

  • PDF

Presticide Resistance Menagement of Pest and Beneficial Arthropods and More Biologically-Based IPM on Apple

  • Croft, B.A.
    • Korean journal of applied entomology
    • /
    • v.32 no.4
    • /
    • pp.373-381
    • /
    • 1993
  • Resistance evolution to organophosphate-based pesticides in apple and pear inhabiting arthropods of western North America extends to many classes of pest and some beneficial species. Resistance management programs to minimize resistance in pests while exploiting it in natural enemies have met with mixed success. Among beneficials, resistances have been exploited mostly among predators of pest mites. Evolution of resistant mites, leafminers, leafhopper, aphids, leafrollers and some internal fruit feeders have led to development of new monitoring methods and means to delay or avoid resistance. But it is resistance to azinphosmethyl in codling moth (Cydia pomonella) that is changing the pest control system and moving it from chemical to biologically-based means. Newly merging IPM system will depend more on use of biological, cultural, behavior and genetic controls. But more selective pesticides also will be needed to augment pheromones, resistant host plants and genetically altered organisms. These more biologically-based tactics will be prone to resistance evolution in pests as well, if used too unilaterally and/or too extensively.

  • PDF

Primary Resistance Compensation of Linear Induction Motor Using Thermocouple (Thermocouple을 이용한 선형 유도전동기의 1차측 저항 보상)

  • Kim, Kyung-Min;Park, Seung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.742-747
    • /
    • 2006
  • This paper describes online stator-resistance estimation of a linear induction motor(LIM) with cage-type secondary using direct thrust control(DTC), where the resistance value is derived from stator-winding temperature estimation using thermocouple. In this paper, corrected stator resistance has an error in actuality measurement resistance. So compensation coefficient $\kappa$ which is decided through comparison and verifying several times relation of calculated resistance and measured motor line-line resistance. The stator-winding temperature information can also be used for monitoring, protection, and fault-tolerant control of the machine. Also, this paper reports the LIM's responses of the flux measured by the proposed stator resistance compensation algorithm.

  • PDF